Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a spec sheet · part 7 of 9

multibox, Industrial Connectivity Products, pages 61 to 70

Pages 61 to 70 of 86

The original document is the PDF (6.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Turck VBM8-AC/DC/AC-RSM 120-*M/S90

Page 61

TURCK Industrial Connectivity Products multibox ® picofast ® Junction Boxes, 10-port • 10 Inputs/Outputs

• For Use with 3-pin Snap Lock

• Quick Disconnect or Integral

Home Run Cable picofast Cordsets • Available with or without LEDs

10-port, J-box, Snap Lock, 48 VDC Application

10-port J-box Standard wiring Integral cable

Specifications 3 A/port, 3.0 A total Black PVC cable 12/24 AWG Foil shield and 26 AWG drain

Pinout Function +V -V Port 1 Port 2 Port 3 Port 4

Color BN BU RD BK VT OG

Function Port 5 Port 6 Port 7 Port 8 Port 9 Port 10

No LEDs Color Tn WH GN YE GY PK

PNP LED

VB 1003-*

VB 1003-PX10-*

10-port, J-box, Snap Lock, 48 VDC Application

Specifications

10-port J-box Standard wiring M16 connector

3 A/port, 3.0 A total 14 pin connector M16 threads Mates with BKM 14-755-* or BKWM 14-755-*

Pinout Function +V -V Port 1 Port 2 Port 3 Port 4

Pin/Color M/BN U/BU P/RD E/BK O/VT C/OG

Function Port 5 Port 6 Port 7 Port 8 Port 9 Port 10

No LEDs Pin/Color N/TN R/WH G/GN S/YE J/GY T/PK

PNP LED

VB 1003-BS14

VB 1003-PX10-BS14

* Length in meters

Pinouts Functional Wiring Diagrams No LED Version

M61

Female

Male

3-pin picofast

14-pin multifast

PNP LED Version

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 62

Industrial Automation Specifications Housing: Connectors: Contacts: LED Current: Temperature: Protection Class: Accessories: Cable Length:

Nylon. PUR. Gold plated brass. 10 mA maximum at 48 VDC supply voltage (per LED). -30°C to +80°C (-22°F to +176°F). IEC IP 67. Closure cap, PSG-CC (optional - 2 included). Standard length for junction boxes and M16 cordsets is nominal 5 meters. Other lengths available by request - Consult factory.

Dimensions

Multibox, picofast

10-Port with Integral Home Run Cable

10-Port with M16 Home Run Connector

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708 www.turck.com

M62

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 63

TURCK Industrial Connectivity Products multibox ® pentafast ® Junction Boxes, 4-port • Single Output per port

• Quick Disconnect or Integral Home run cable

• Threaded Connections • Available with LEDs

4-Port, 3-pin, Threaded, 10-30 VDC Application

Specifications

Pinout

PNP LED

4-Port j-box, 1 signal per port, threaded connectors, integral cable

1 A/port, 3 A total, Black PUR cable 2X24 AWG PWR Pair, 4X26 Signal

Function +V -V Port 1

Color BN BU WH

Function Port 2 Port 3 Port 4

Color GN YE GY

VBV 403M-PX5-*M/S90

4-Port j-box, 1 signal per port, threaded connectors, eurofast ® connector

1 A/port, 3 A total, 12-pin eurofast ® M12 connector, 12 conductors, Mates with RKC- 12T

Function +V -V Port 1/4

Pin 2 7 1

Function Port 2/4 Port 3/4 Port 4/4

Pin 3 4 5

VBV 403M-PX5-FS 12

M63

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 64

Industrial Automation Specifications Housing: Connectors: Contacts: Threaded Inserts: Cable: Temperature: Protection Class: Cable Length:

Nylon PUR (J1-J4), Nylon P1 Gold plated brass Nickel plated brass See table -30°C to +80°C (-22°F to 176°F) IP67 Standard length for junction boxes and multifast series quick disconnect cordsets in nominal 5 meters. Other lengths available by request - consult factory

Dimensions VBV 403M-PX5-*M/S90

Multibox, pentafast

VBV 403M-PX5-FS 12

Pinout Female

Male

3-pin pentafast

12-pin eurofast

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708 www.turck.com

M64

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 65

TURCK Industrial Connectivity Products multibox ® pentafast ® Junction Boxes, 8-port • Single Output per port

• Quick Disconnect or Integral Home run cable

• Threaded Connections • Available with LEDs

8-Port, 3-pin, Threaded, 10-30 VDC Application

Specifications

Pinout

PNP LED

8-Port j-box, 1 signal per port, threaded connectors, integral cable

1 A/port, 3 A total, Black PUR cable 2X24 AWG Pwr Pair, 8X26 Signal

Function +V -V Port 1 Port 2 Port 3

Color BN BU WH GN YE

Function Port 4 Port 5 Port 6 Port 7 Port 8

Color GY PK RD BK VT

VBV 803-PX9-*M/S90

8-Port j-box, 1 signal per port, threaded connectors, eurofast ® connector

3 A/port, 3 A total, 12-pin eurofast ® M12 connector, 12 conductors, Mates with RKC- 12T-*

Function +V -V Port 1 Port 2 Port 3

Pin 2 7 1 3 4

Function Port 4 Port 5 Port 6 Port 7 Port 8

Pin 5 6 8 11 12

VBV 803Z-PX9-FS 12

M65

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 66

Industrial Automation Specifications Housing: Connectors: Contacts: Threaded Inserts: Cable: Temperature: Protection Class: Cable Length:

Nylon/yellow Nylon/yellow Gold plated brass Nickel plated brass See table -30 C to +80 C (-22 F to 176 F) IP67 Standard length for junction boxes and multifast series quick disconnect cordsets in nominal 5 meters. Other lengths available by request - consult factory

Dimensions VBV 803-PX9-*M/S90

Multibox, pentafast

VBV 803Z-PX9-FS 12

Pinout Female

Male

3-pin pentafast

12-pin eurofast

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708 www.turck.com

M66

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 67

TURCK Industrial Connectivity Products multibox ® minifast ® Junction Boxes, 3-Pin • 4, 6 and 8 Ports

• Simplifies Wiring Installations

• Quick Disconnect or Integral

Home Run Cable

4-port, 250 VAC/300 VDC Application

Specifications

4-port J-box Standard wiring Integral cable

4 A/port, 9 A total PVC cable, black, 6/18 AWG, foil shield and 20 AWG drain CSA Certified

4-port J-box Standard wiring multifast connector

4 A/port, 7 A total 12-pin multifast connector, 6 conductors, mates with CKRM 12-6-* CSA Certified

4-port j-box Standard wiring minifast connector

4 A/port, 9 A total 6-pin minifast connector, 6 conductors, mates with RKM 61-*M CSA Certified

Pinout Function Common (L1) Ground J1 Load (L2)

Color WH GN RD

Function Common (L1) Ground J1 Load (L2)

Function Common (L1) Ground J1 Load (L2)

Function J2 Load (L2) J3 Load (L2) J4 Load (L2)

Part Number Color OG BK BU

4 RKF 30-*M

Pin / Color Function 5 / WH J2 Load (L2) 7 / GN J3 Load (L2) 6 / RD J4 Load (L2)

Pin / Color 1 / OG 4 / BK 2 / BU

4 RKF 30-CS12

Pin / Color Function 1 / WH J2 Load (L2) 3 / GN J3 Load (L2) 2 / RD J4 Load (L2)

Pin / Color 4 / OG 5 / BK 6 / BU

4 RKF 30-B1161

6-port, 250 VAC/300 VDC Application

Specifications

Pinout

Part Number

6-port J-box Standard wiring Integral cable

4 A/port, 9 A total PVC cable, black, 8/18 AWG, foil shield and 20 AWG drain CSA Certified

Function Color Common (L1)WH Ground GN J1 Load (L2) RD J2 Load (L2) OG

Function J3 Load (L2) J4 Load (L2) J5 Load (L2) J6 Load (L2)

Color BK BU YE BN

6 RKF 30-*M

6-port J-box Standard wiring multifast connector

4 A/port, 7 A total 12-pin multifast connector, 8 conductors, mates with CKRM 12-8-* CSA Certified

Function Pin / Color Common (L1)5 / WH Ground 7 / GN J1 Load (L2) 6 / RD J2 Load (L2) 1 / OG

Function J3 Load (L2) J4 Load (L2) J5 Load (L2) J6 Load (L2)

Pin / Color 4 / BK 2 / BU 3 / YE 8 / BN

6 RKF 30-CS12

8-port, 250 VAC/300 VDC Application

Specifications

Pinout

Part Number

8-port J-box Standard wiring Integral cable

4 A/port, 9 A total PVC cable, black, 10/18 AWG, foil shield and 20 AWG drain CSA Certified

Function Color Common (L1)WH Ground GN J1 Load (L2) RD J2 Load (L2) VT J3 Load (L2) BK

Function J4 Load (L2) J5 Load (L2) J6 Load (L2) J7 Load (L2) J8 Load (L2)

Color BU GY YE OG BN

8 RKF 30-*M

8-port J-box, Standard wiring multifast connector

4 A/port, 7 A total 12-pin multifast connector, 10 conductors, mates with CKRM 12-10-* CSA Certified

Function Pin / Color Common (L1)5 / WH Ground 7 / GN J1 Load (L2) 6 / RD J2 Load (L2) 1 / VT J3 Load (L2) 4 / BK

Function J4 Load (L2) J5 Load (L2) J6 Load (L2) J7 Load (L2) J8 Load (L2)

Pin / Color 2 / BU 3 / GY 8 / YE 9 / OG 10 / BN

8 RKF 30-CS12

* Length in meters

M67

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 68

Industrial Automation Specifications Housing: Connector: Contacts: Cable: Temperature: Protection: Cable Length:

Die cast aluminum alloy. Nickel plated brass, oil resistant PUR contact carrier. Gold plated brass. See table for specifications. -30°C to +80°C (-22°F to +176°F). NEMA 1, 3, 4, 6P and IEC IP 67. Standard cable length is 6 meters. Other lengths available by request - consult factory.

Dimensions 8-Port

6-Port

Multibox, minifast

4-Port

Wiring Diagram

Notes: Clearance holes for 1/4-20 screws (2 places). All housings are 34.0 mm in height.

Load (L2) is individual output. Common (L1) and Ground are wired parallel internally.

Pinout Female

Male

Male

3-pin minifast

6-pin minifast

12-pin multifast

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708 www.turck.com

M68

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 69

TURCK Industrial Connectivity Products multibox ® minifast ® Junction Boxes, 3-pin • 6 and 8 Ports

• Simplifies Wiring Installations

• Quick Disconnect minifast Connector

6-port, 250 VAC / 300 VDC Application

6-port J-box Standard wiring, minifast connector

Specifications 4 A/port 9 A total 8-pin minifast connector 8 conductors Mates with RKM 86-*M CSA Certified

Pinout Function Common (L1) Ground J1 Load (L2) J2 Load (L2)

Pin / Color Function 5 / WH J3 Load (L2) 7 / GN J4 Load (L2) 6 / RD J5 Load (L2) 1 / OG J6 Load (L2)

Part Number Pin / Color 4 / BK 2 / BU 3 / WH / BK 8 / RD / BK

6 RKF 30-RSF80

8-port, 250 VAC / 300 VDC Application

8-port J-box Standard wiring, minifast connector

Specifications 4 A/port 9 A total 10-pin minifast connector 10 conductors Mates with RKM 106-*M CSA NRTL© Certified

Pinout Function Common (L1) Ground J1 Load (L2) J2 Load (L2) J3 Load (L2)

Pin / Color Function 10 / Wt J4 Load (L2) 8 / GN J5 Load (L2) 7 / RD J6 Load (L2) 1 / OG J7 Load (L2) 9 / BK J8 Load (L2)

Part Number Pin / Color 2 / BU 3 / WH / BK 4 / RD / BK 5 / GN / BK 6 / OG / BK

8 RKF 30-RSF100

Functional Wiring Diagram

M69

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708 www.turck.com

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 70

Industrial Automation Specifications Housing: Connectors: Contacts: Temperature: Protection:

Die cast aluminum alloy. Nickel plated brass, oil resistant PUR contact carrier. Gold plated brass. -30°C to +80°C (-22°F to +176°F). NEMA 1, 3, 4, 6P and IEC IP 67.

Dimensions 8-Port

Multibox, minifast

6-Port

Notes: Clearance holes for 1/4-20 screws (2 places). All housings are 34.0 mm in height.

Pinout Female

Male

Male

3-pin minifast

8-pin minifast

10-pin minifast

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708 www.turck.com

M70

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com