The text of a manual · part 15 of 30
Total Access 850 System Manual: User Interface Guide, pages 135 to 144
Pages 135 to 144 of 292, from Total Access 850 System Manual
The original document is the PDF (3.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Adtran 1200375L1
Page 135
Total Access 850 System Manual
Section 4 User Interface Guide
CONNECTION (VOICE) > SETUP > CALL CONTROL
The Call Control setting is used to configure the correct Voice Gateway protocol for voice signaling control between the Total Access 850 and the configured Gateway. The CALL CONTROL setting must be configured correctly before the voice circuits will work correctly. The Total Access 850 supports Jetstream, Coppercom, Tollbridge, and LES-CAS. The default is LES-CAS. CONNECTION (VOICE) > SETUP > LES PROFILE
This options applies when CALL CONTROL is set to LES-CAS. The choices are ITU PROFILE 1, ATM FORUM PROFILE 9, and ATM FORUM PROFILE 10. The default is ATM FORUM PROFILE 10. ATM FORUM PROFILE 9 provides ability to support 64 kbps PCM calls. ATM FORUM PROFILE 10 enables support of 64 Kbps PCM calls as well as 32 kbps ADPCM calls. CONNECTION (VOICE) > SETUP > LES-CAS GW SIM
Configures the interface to simulate a LES-CAS gateway. Enable this parameter only when back-to-back IAD testing.
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > PVC CONFIG > QOS Use these menus to configure the Quality of Service parameters for the connection. This menu does not apply to logical connections involving a VOICE port. QOS > QUALITY OF SERVICE
Quality of Service for ATM Undefined Bit Rate (UBR) and non-real time Variable Bit Rate (VBR) for the data PVC DLCI. This setting depends on the type of network ATM service being provided. QOS > PEAK CELL RATE
Defines the peak cell rate for the data PVC. This setting is normally used for Undefined Bit Rate (UBR) connections and is calculated using the following equation: Peak Cell Rate = Bit Rate / 424 The total of all peak cell rates for the ATM network connection must not exceed the line rate. The range for this parameter is 0 to 3623.
L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS Displays all available ATM statistics (both overall and PVC-specific).
64203376L1-1B
© 2004 ADTRAN, Inc.
135
Page 136
Section 4 User Interface Guide
Total Access 850 System Manual
L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > ATM STATUS Displays overall ATM link performance statistics. The following statistics are available: AP: TX CELLS
Number of cells transmitted over the ATM link.
AP: RX CELLS
Number of cells received over the ATM link.
AP: RX OAM CELLS
Number of Operation, Administration, and Maintenance cells received on the ATM link. OAM cells provide network fault indications, performance information, and data and diagnostic functions.
AP: RECEIVE CELL DISCARDED
Number of cells received that are received and discarded. An incrementing count in this field could indicate a configuration problem with the ATM layer.
AP: RECEIVE CELL ERRORS
Number of cells received that contain a Header Error Control (HEC) error. The HEC is a CRC code located in the last byte of the ATM cell header that’s used for checking integrity.
AP: SYNC
Indicates cell delineation at the ATM layer.
AP: OUT OF CELL
Indicates loss of cell delineation at the ATM layer.
AAL5: TRANSMIT FRAMES
Number of ATM Adaptation Layer Type 5 frames transmitted on the ATM link.
AAL5: RECEIVE FRAMES
Number of ATM Adaptation Layer Type 5 frames received on the ATM link.
AAL5: TRANSMIT DISCARDED FRAMES
Number of ATM Adaptation Layer Type 5 transmitted frames that were discarded before transmission.
AAL5: RECEIVE ERRORS
Number of ATM Adaptation Layer Type 5 frames that were received and contained errors.
AAL5: RECEIVE DISCARDED FRAMES
Number of ATM Adaptation Layer Type 5 frames that were received but then discarded.
AAL5: NO ATM FRAMES
Internal ADTRAN use only.
AAL5: NO DATA PACKETS
Internal ADTRAN use only.
L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > ATM STATUS > CLEAR STATS Clears all ATM statistics contained in the ATM status field and returns all counters to 0.
L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > PVC STATUS View the ATM PVC statistics from this menu.
L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > PVC STATUS > NUM Displays the index number in the PVC Status menu.
136
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 137
Total Access 850 System Manual
Section 4 User Interface Guide
L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > PVC STATUS > SUB-INTERFACE The T1 SUB-INTERFACE is ATM[0.0], representing the T1 physical and logical ports, respectively. This is a read-only field.
L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > PVC STATUS > AAL STATS Shows the statistics of ATM Adaptation Layer frames. MAX PDU SIZE
Maximum Protocol Data Unit size for the ATM AAL5 frame. All data information larger than the PDU must be transmitted in multiple frames.
TX DATA BYTES
Number of AAL5 data bytes transmitted.
TX FRAMES
Number of AAL5 frames transmitted.
TX CELLS (ALL TYPES)
Total number of AAL5 cells transmitted (all types).
TX OAM CELLS
Number of AAL5 Operations, Administration, and Maintenance cells transmitted.
TX RM CELLS
Number of AAL5 Resource Management cells transmitted.
TX EFCI=1 CELLS
Number of AAL5 EFCI=1 cells transmitted.
TX CLPI=1 CELLS
Number of AAL5 CLPI=1 transmitted.
RX DATA BYTES
Number of AAL5 data bytes received.
RX FRAMES
Number of AAL5 frames received
RX USER CELLS
Number of AAL5 user cells received
RX OAM CELLS
Number of AAL5 OAM cells received
RX BAD OAM CELLS
Number of AAL5 Bad OAM cells received
RX RM CELLS
Number of AAL5 RM cells received
RX BAD RM CELLS
Number of AAL5 Bad RM cells received
RX EFCI=1 CELLS
Number of AAL5 EFCI=1 cells received.
RX CLPI=1 CELLS
Number of AAL5 CLPI=1 cells received.
DISCARD RX CELLS
Number of AAL5 RX cells which were discarded.
DISCARD RX FRAMES
Number of AAL5 RX frames which were discarded.
DISCARD TX FRAMES
Number of AAL5 TX frames which were discarded.
TX QUEUE OVERFLOW
Number of cells discarded due to queue overflow.
TX OUT OF CELLS
Number of AAL5 TX Out of Cells.
TX INACTIVE
Number of TX frames discarded while PVC is inactive.
RX INACTIVE
Number of RX frames discarded while PVC is inactive.
CRC ERRORS
Number of AAL5 CRC Errors.
REASSEMBLY TIMEOUTS Number of AAL5 Reassembly Timeouts. TOO LONG FRAMES
Number of AAL5 Too Long Frames.
CLEAR COUNTS
Clears all recorded statistics and returns all counters to 0.
64203376L1-1B
© 2004 ADTRAN, Inc.
137
Page 138
Section 4 User Interface Guide
Total Access 850 System Manual
L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > PVC STATUS > PROTOCOL STATUS Use these menus to view the AAL2 STATS, POTS STATS, and to CLEAR STATS for the PVC Protocol. AAL2 STATS
ATM Adaptation Layer 2 statistics is used to provide error information on voice traffic. This menu displays RX AAL2 HEC ERRORS, RX AAL2 SEQK ERRORS, RX VOICE SEQ ERRORS, RX VOICE BAD CID, RX VOICE BAD UUI, RX VOICE EOC CELLS, and PEAK CELL RATE.
RX AAL2 HEC ERRORS
A CRC code (used for data integrity checks) is contained in the last byte of an AAL2 header. A received HEC error could result in dropped packets and poor voice quality. RX AAL2 SEQK ERRORS
A single bit of the AAL2 header is used as a sequence bit and toggles from 1 to 0 with each successive transmitted cell. If two cells are received back to back with the same sequence bit, a sequence error is denoted. RX VOICE SEQ ERRORS
Indicates that the Total Access 850 received voice packets that were out of sequence according to the voice sequencing bits. The Total Access 850 does not drop these packets, but the error is logged because invalid sequence numbers were received. RX VOICE BAD CID
Indicates that the channel identifier (used for identifying voice calls in the ATM cell) was not valid. RX VOICE BAD UUI
The User Indication designates the signaling bit pattern for PCM/ADPCM and identifies the packet as Type 1 (voice) or Type 3 (signaling). This error indicates the Total Access 850 received an incorrectly formatted UUI. RX VOICE EOC CELLS
Indicates an EOC cell was received with a voice designation. PEAK CELL RATE
Indicates the number of times (since the last statistics reset) that the PVC has reached the peak cell rate.
138
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 139
Total Access 850 System Manual
Section 4 User Interface Guide
POTS STATS
Selecting this menu options will show real-time indication status of each voice port on the Total Access 850. On a per port basis, the user can determine which ports are active/inactive as well as view other statistics like TXQ, INSERTS and DROPS INDICATORS. The Echo Canceller module ADPCM functionality automatically shifts ON/OFF when fax or modem calls are placed. To find out the current status of the Echo Canceller functionality, check the current status of each FXS port. The path of the current status can be found at the following path: L2 PROTOCOL > STATUS > PVC STATUS > PROTOCOL STATUS > POTS STATS > CODING TYPE (this will display either PCM of ADPCM).
TXQ
Displays the numbers of cells waiting in the buffer to transmit out the POTS port. Buffering voice cells is used to minimize jitter. INSERTS
Displays the number of cells the Total Access 850 inserted on the analog interface to keep the current voice call connected when the network is idle. DROPS
Displays the number of voice cells the Total Access 850 dropped due to a full buffer. This indicates that the network is sending traffic faster than the Total Access 850 is anticipating receiving cells; thus overrunning the jitter buffer. Excess drops could result in a timing mismatch. CLEAR STATS
Clears all recorded statistics and returns all counters to 0.
L2 PROTOCOL (T1 ATM FIRMWARE) – T1 INTERFACE > CUMTN Configure the L2 PROTOCOL parameters and view the status of the T1 interface using Copper Mountain Frame Relay protocol from this menu.
64203376L1-1B
© 2004 ADTRAN, Inc.
139
Page 140
Section 4 User Interface Guide
Total Access 850 System Manual
L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG Configure the L2 PROTOCOL parameters for the T1 interface using Copper Mountain Frame Relay protocol. To insert a new profile, press the I key when over the NUM column. A new inserted profile will always be set up with the default parameters. To copy parameters from an old profile to this newly inserted profile, use the copy (C) and paste (P) keys. Entire configuration trees can be copied with this method.
To delete an unused profile, use the D key when the cursor is over the number in the NUM column. Once deleted, the profile is gone permanently.
L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG > NUM Displays the index number in the DLCI config table. The number range is 0-9.
L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG > ACTIVE When this parameter is set to YES (def), the mapping is used to determine the protocols used. If set to NO, the unit will ignore the virtual circuit with this DLCI.
L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG > INTERFACE Shows the user the physical and logical port associated with each DLCI. This is a read-only field.
L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG > DLCI The DLCI (Data Link Connection Identifier) number identifies the virtual circuit being configured. The DLCI range is 16-1023. The default is 16-25 corresponding to the index numbers 0-9 respectfully.
L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG > CONNECTION Select the physical and logical method of data transfer over the virtual path. There are two valid connection entries: ROUTER and VOICE. Select ROUTER to connect traffic from this PVC to the Total Access 850 integral IP router. Select VOICE to connect traffic from this PVC to a voice connection (normally an FXS interface).
L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG > SETUP This submenu only appears for VOICE connections. Configure the CALL CONTROL for voice gateway using this menu.
L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG > SETUP > CALL CONTROL The CALL CONTROL setting is used to configure the correct Voice Gateway protocol for voice signaling control between the Total Access 850 and the configured Gateway. The Call Control setting must be configured correctly before the voice circuits will work correctly. The Total Access 850 supports JETSTREAM, COPPERCOM, TOLLBRIDGE and LES-CAS (def).
140
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 141
Total Access 850 System Manual
Section 4 User Interface Guide
L2 PROTOCOL (T1 ATM–T1–CUMTN) > STATUS View the status of the Copper Mountain DLCI connections.
L2 PROTOCOL (T1 ATM–T1–CUMTN) > STATUS > NUM Displays the index number for the Status menu entries.
L2 PROTOCOL (T1 ATM–T1–CUMTN) > STATUS > SUB-INTERFACE The T1 SUB-INTERFACE is CuMtn[0.0] when the L2 PROTOCOL is set for CUMTN FRE. The [0.0] represents the T1 physical and logical ports respectively. This is a read-only field.
L2 PROTOCOL (T1 ATM–T1–CUMTN) > STATUS> DLCI STATE This is a read-only field that displays the live DLCI state.
L2 PROTOCOL (T1 ATM–T1–CUMTN) > STATUS > PROTOCOL STATUS This is a read-only field that displays the live protocol status. Menu visible for physical and logical VOICE ports only.
L2 PROTOCOL (T1 ATM–T1–CUMTN) > STATUS > PROTOCOL STATUS > POTS STATS View the voice port activity and coding type.
L2 PROTOCOL (T1 ATM–T1–CUMTN) > STATUS > PROTOCOL STATUS > CLEAR STATS Clears all recorded statistics for the interface and returns all counters to 0.
L2 PROTOCOL (T1 ATM FIRMWARE) – V.35 INTERFACE Configure the L2 PROTOCOL parameters and view the status of the V.35 interface using items from this menu. The V.35 interface is only available when the configured T1 network protocol is ATM. Refer to L2 Protocol (T1 ATM Firmware) – T1 Interface > ATM on page 129.
L2 PROTOCOL (T1 ATM – V35) > PROTOCOL Configure the L2 PROTOCOL mode. Choices are FRF5 (def) and FRF8. Selecting FRF5 configures the interface for network interworking and should be used for Frame Relay over ATM applications. Selecting FRF8 configures the interface for service interworking allowing the Total Access 850 to make the translation between Frame Relay signaling on the V35 interface and ATM protocols on the network interface.
L2 PROTOCOL (T1 ATM – V35) > CONFIG Configures the L2 PROTOCOL parameters for either FRF5 or FRF8 signaling.
64203376L1-1B
© 2004 ADTRAN, Inc.
141
Page 142
Section 4 User Interface Guide
Total Access 850 System Manual
L2 PROTOCOL (T1 ATM – V35) > CONFIG > UNI MAINT PROTOCOL Specifies the maintenance protocol or signaling protocol between the local V.35 port and the attached DTE port. The choices are ANNEX D (def), ANNEX A, LMI, and STATIC.
L2 PROTOCOL (T1 ATM – V35) > CONFIG > UNI POLL TIMEOUT T392 (5-30) T392 for signaling protocol. This parameter has no meaning if the UNI MAINT PROTOCOL is set to STATIC (no signaling). The default setting is 10.
L2 PROTOCOL (T1 ATM – V35)> STATUS Displays the L2 statistics for FRF5 or FRF8 operation.
L2 PROTOCOL (T1 ATM – V35)> STATUS> PORT Displays statistics for all the PVCs configured on this port. The following statistics are available: PORT INDEX
Port number
SIGNAL STATE
Frame relay state
TX FRAMES
Number of frames transmitted
RX FRAMES
Number of frames received
TX BYTES
Number of bytes transmitted
RX BYTES
Number of bytes received
FULL STATUS TX FRAMES
Number of Frame Relay signaling packets transmitted out the port
FULL STATUS RX FRAMES
Number of Frame Relay signaling packets received by the port
LINK INTEGRITY STATUS TX FRAMES
Number of Link Integrity signaling packets transmitted out the port
LINK INTEGRITY STATUS RX FRAMES
Number of Link Integrity signaling received by the port
DROP UNKNOWN DLCI
Number of frames received that were not associated with any known PVC
DROP INVALID DLCI
Number of frames received that had illegal DLCIs
CLEAR STATS
When activated, this field will clear all frame relay port stats
L2 PROTOCOL (V35[2]-ATM)> STATUS> PVC(S) Displays statistics for all the PVCs configured on this port on a PVC basis. The following statistics are available:
142
DLCI
DLCI number
STATE
Frame relay state
TX FRAMES
Number of frames transmitted
RX FRAMES
Number of frames received
RX BYTES
Number of bytes received
DE COUNT
Number of packets received on an individual DLCI with the DE bit set
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 143
Total Access 850 System Manual
Section 4 User Interface Guide
CR COUNT
Number of packets received on an individual DLCI with the CR bit set
BECN COUNT
Number of packets received on an individual DLCI with the BECN bit set
FECN COUNT
Number of packets received on an individual DLCI with the FECN bit set
UNKNOWN FRAME
RX Frames received that were not associated with any PVC entries
L2 PROTOCOL (T1 ATM FIRMWARE) – DSX INTERFACE Configure the L2 PROTOCOL parameters and view the status of the integrated DSX interface using items from this menu.
L2 PROTOCOL (T1 ATM – DSX) > CONFIG Configures the voice parameters for the interface.
INTERFACES (T1 ATM – DSX) > CONFIG > SIGNALING Configures the voice signaling implemented on the interface. The signaling must match the network application. The choices are: E&M (TANDEM)
Sets the DSX interface to use E&M signaling.
LOOP START
Sets the DSX interface to use loop start signaling.
GROUND START
Sets the DSX interface to use ground start signaling.
ISDN PRI
Sets the DSX interface to use common channel signaling for ISDN.
INTERFACES (T1 ATM – DSX) > CONFIG > TX OAM Configures the Total Access 850 to transmit an Operation, Administration, and Maintenance (OAM) cell to the network (voice gateway) when the DSX interface is down.
INTERFACES (T1 ATM – DSX) > CONFIG > RX OAM Configures the Total Access 850 to transmit an alarm condition to the DSX interface when the network (voice gateway) is down.
INTERFACES (T1 ATM – DSX) > CONFIG > LEGACY CONFIG Digital trunk channel ID's are bits used to identify voice calls being carried within ATM cells. Some gateways do not support higher channel IDs, therefore the Total Access 850 supports CIDs from 16 or 65. The default is DSX CID FROM 65.
64203376L1-1B
© 2004 ADTRAN, Inc.
143
Page 144
Section 4 User Interface Guide
Total Access 850 System Manual
L2 PROTOCOL (ALL FIRMWARE) – ETH INTERFACE > 802.3 PROTOCOL Configure the L2 PROTOCOL parameters and view the status of the Ethernet interface from this menu.
L2 PROTOCOL (ALL–ETH–802.3) > PROTOCOL Displays the L2 PROTOCOL for the 10/100BaseT Ethernet port. Currently only 802.3 is supported.
L2 PROTOCOL (ALL–ETH–802.3) > CONFIG Configure the mode for this 10/100BASET Ethernet port from this menu.
L2 PROTOCOL (ALL–ETH–802.3) > CONFIG > MODE The mode identifies how the data will be forwarded. The choices are: ROUTE IP (def)
All IP data will be routed
BRIDGE ALL
All data will be bridged
ROUTE IP/BRIDGE OTHER
All IP data will be routed. All other data will be bridged.
L2 PROTOCOL (ALL–ETH–802.3) > STATUS View the L2 PROTOCOL statistics for the 10/100BASET Ethernet port from this menu.
L2 PROTOCOL (ALL–ETH–802.3) > STATUS > TX PACKETS Total number of packets transmitted out the Ethernet port.
L2 PROTOCOL (ALL–ETH–802.3) > STATUS > RX PACKETS Total number of packets received from the Ethernet port.
L2 PROTOCOL (ALL–ETH–802.3) > STATUS > TX ERRORS Total number of transmit errors encountered on Ethernet port.
L2 PROTOCOL (ALL–ETH–802.3) > STATUS > SINGLE COLLISIONS Total number of single collisions before successful transmission.
L2 PROTOCOL (ALL–ETH–802.3) > STATUS > MULTIPLE COLLISIONS Total number of multiple collisions before successful transmission.
L2 PROTOCOL (ALL–ETH–802.3) > STATUS > EXCESSIVE COLLISIONS Total number of collisions that resulted in packet being dropped.
L2 PROTOCOL (ALL–ETH–802.3) > STATUS > DEFERRED TRANSMISSIONS Total number of packets deferred due to collisions.
L2 PROTOCOL (ALL–ETH–802.3) > STATUS > CARRIER SENSE ERRORS Total number of carrier sense errors encountered (no link integrity).
144
© 2004 ADTRAN, Inc.
64203376L1-1B