Page 135

Total Access 850 System Manual

Section 4 User Interface Guide

CONNECTION (VOICE) > SETUP > CALL CONTROL

The Call Control setting is used to configure the correct Voice Gateway protocol for voice signaling control between the Total Access 850 and the configured Gateway. The CALL CONTROL setting must be configured correctly before the voice circuits will work correctly. The Total Access 850 supports Jetstream, Coppercom, Tollbridge, and LES-CAS. The default is LES-CAS. CONNECTION (VOICE) > SETUP > LES PROFILE

This options applies when CALL CONTROL is set to LES-CAS. The choices are ITU PROFILE 1, ATM FORUM PROFILE 9, and ATM FORUM PROFILE 10. The default is ATM FORUM PROFILE 10. ATM FORUM PROFILE 9 provides ability to support 64 kbps PCM calls. ATM FORUM PROFILE 10 enables support of 64 Kbps PCM calls as well as 32 kbps ADPCM calls. CONNECTION (VOICE) > SETUP > LES-CAS GW SIM

Configures the interface to simulate a LES-CAS gateway. Enable this parameter only when back-to-back IAD testing.

L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > PVC CONFIG > QOS Use these menus to configure the Quality of Service parameters for the connection. This menu does not apply to logical connections involving a VOICE port. QOS > QUALITY OF SERVICE

Quality of Service for ATM Undefined Bit Rate (UBR) and non-real time Variable Bit Rate (VBR) for the data PVC DLCI. This setting depends on the type of network ATM service being provided. QOS > PEAK CELL RATE

Defines the peak cell rate for the data PVC. This setting is normally used for Undefined Bit Rate (UBR) connections and is calculated using the following equation: Peak Cell Rate = Bit Rate / 424 The total of all peak cell rates for the ATM network connection must not exceed the line rate. The range for this parameter is 0 to 3623.

L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS Displays all available ATM statistics (both overall and PVC-specific).

64203376L1-1B

© 2004 ADTRAN, Inc.

135

Page 136

Section 4 User Interface Guide

Total Access 850 System Manual

L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > ATM STATUS Displays overall ATM link performance statistics. The following statistics are available: AP: TX CELLS

Number of cells transmitted over the ATM link.

AP: RX CELLS

Number of cells received over the ATM link.

AP: RX OAM CELLS

Number of Operation, Administration, and Maintenance cells received on the ATM link. OAM cells provide network fault indications, performance information, and data and diagnostic functions.

AP: RECEIVE CELL DISCARDED

Number of cells received that are received and discarded. An incrementing count in this field could indicate a configuration problem with the ATM layer.

AP: RECEIVE CELL ERRORS

Number of cells received that contain a Header Error Control (HEC) error. The HEC is a CRC code located in the last byte of the ATM cell header that’s used for checking integrity.

AP: SYNC

Indicates cell delineation at the ATM layer.

AP: OUT OF CELL

Indicates loss of cell delineation at the ATM layer.

AAL5: TRANSMIT FRAMES

Number of ATM Adaptation Layer Type 5 frames transmitted on the ATM link.

AAL5: RECEIVE FRAMES

Number of ATM Adaptation Layer Type 5 frames received on the ATM link.

AAL5: TRANSMIT DISCARDED FRAMES

Number of ATM Adaptation Layer Type 5 transmitted frames that were discarded before transmission.

AAL5: RECEIVE ERRORS

Number of ATM Adaptation Layer Type 5 frames that were received and contained errors.

AAL5: RECEIVE DISCARDED FRAMES

Number of ATM Adaptation Layer Type 5 frames that were received but then discarded.

AAL5: NO ATM FRAMES

Internal ADTRAN use only.

AAL5: NO DATA PACKETS

Internal ADTRAN use only.

L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > ATM STATUS > CLEAR STATS Clears all ATM statistics contained in the ATM status field and returns all counters to 0.

L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > PVC STATUS View the ATM PVC statistics from this menu.

L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > PVC STATUS > NUM Displays the index number in the PVC Status menu.

136

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 137

Total Access 850 System Manual

Section 4 User Interface Guide

L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > PVC STATUS > SUB-INTERFACE The T1 SUB-INTERFACE is ATM[0.0], representing the T1 physical and logical ports, respectively. This is a read-only field.

L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > PVC STATUS > AAL STATS Shows the statistics of ATM Adaptation Layer frames. MAX PDU SIZE

Maximum Protocol Data Unit size for the ATM AAL5 frame. All data information larger than the PDU must be transmitted in multiple frames.

TX DATA BYTES

Number of AAL5 data bytes transmitted.

TX FRAMES

Number of AAL5 frames transmitted.

TX CELLS (ALL TYPES)

Total number of AAL5 cells transmitted (all types).

TX OAM CELLS

Number of AAL5 Operations, Administration, and Maintenance cells transmitted.

TX RM CELLS

Number of AAL5 Resource Management cells transmitted.

TX EFCI=1 CELLS

Number of AAL5 EFCI=1 cells transmitted.

TX CLPI=1 CELLS

Number of AAL5 CLPI=1 transmitted.

RX DATA BYTES

Number of AAL5 data bytes received.

RX FRAMES

Number of AAL5 frames received

RX USER CELLS

Number of AAL5 user cells received

RX OAM CELLS

Number of AAL5 OAM cells received

RX BAD OAM CELLS

Number of AAL5 Bad OAM cells received

RX RM CELLS

Number of AAL5 RM cells received

RX BAD RM CELLS

Number of AAL5 Bad RM cells received

RX EFCI=1 CELLS

Number of AAL5 EFCI=1 cells received.

RX CLPI=1 CELLS

Number of AAL5 CLPI=1 cells received.

DISCARD RX CELLS

Number of AAL5 RX cells which were discarded.

DISCARD RX FRAMES

Number of AAL5 RX frames which were discarded.

DISCARD TX FRAMES

Number of AAL5 TX frames which were discarded.

TX QUEUE OVERFLOW

Number of cells discarded due to queue overflow.

TX OUT OF CELLS

Number of AAL5 TX Out of Cells.

TX INACTIVE

Number of TX frames discarded while PVC is inactive.

RX INACTIVE

Number of RX frames discarded while PVC is inactive.

CRC ERRORS

Number of AAL5 CRC Errors.

REASSEMBLY TIMEOUTS Number of AAL5 Reassembly Timeouts. TOO LONG FRAMES

Number of AAL5 Too Long Frames.

CLEAR COUNTS

Clears all recorded statistics and returns all counters to 0.

64203376L1-1B

© 2004 ADTRAN, Inc.

137

Page 138

Section 4 User Interface Guide

Total Access 850 System Manual

L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > PVC STATUS > PROTOCOL STATUS Use these menus to view the AAL2 STATS, POTS STATS, and to CLEAR STATS for the PVC Protocol. AAL2 STATS

ATM Adaptation Layer 2 statistics is used to provide error information on voice traffic. This menu displays RX AAL2 HEC ERRORS, RX AAL2 SEQK ERRORS, RX VOICE SEQ ERRORS, RX VOICE BAD CID, RX VOICE BAD UUI, RX VOICE EOC CELLS, and PEAK CELL RATE.

RX AAL2 HEC ERRORS

A CRC code (used for data integrity checks) is contained in the last byte of an AAL2 header. A received HEC error could result in dropped packets and poor voice quality. RX AAL2 SEQK ERRORS

A single bit of the AAL2 header is used as a sequence bit and toggles from 1 to 0 with each successive transmitted cell. If two cells are received back to back with the same sequence bit, a sequence error is denoted. RX VOICE SEQ ERRORS

Indicates that the Total Access 850 received voice packets that were out of sequence according to the voice sequencing bits. The Total Access 850 does not drop these packets, but the error is logged because invalid sequence numbers were received. RX VOICE BAD CID

Indicates that the channel identifier (used for identifying voice calls in the ATM cell) was not valid. RX VOICE BAD UUI

The User Indication designates the signaling bit pattern for PCM/ADPCM and identifies the packet as Type 1 (voice) or Type 3 (signaling). This error indicates the Total Access 850 received an incorrectly formatted UUI. RX VOICE EOC CELLS

Indicates an EOC cell was received with a voice designation. PEAK CELL RATE

Indicates the number of times (since the last statistics reset) that the PVC has reached the peak cell rate.

138

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 139

Total Access 850 System Manual

Section 4 User Interface Guide

POTS STATS

Selecting this menu options will show real-time indication status of each voice port on the Total Access 850. On a per port basis, the user can determine which ports are active/inactive as well as view other statistics like TXQ, INSERTS and DROPS INDICATORS. The Echo Canceller module ADPCM functionality automatically shifts ON/OFF when fax or modem calls are placed. To find out the current status of the Echo Canceller functionality, check the current status of each FXS port. The path of the current status can be found at the following path: L2 PROTOCOL > STATUS > PVC STATUS > PROTOCOL STATUS > POTS STATS > CODING TYPE (this will display either PCM of ADPCM).

TXQ

Displays the numbers of cells waiting in the buffer to transmit out the POTS port. Buffering voice cells is used to minimize jitter. INSERTS

Displays the number of cells the Total Access 850 inserted on the analog interface to keep the current voice call connected when the network is idle. DROPS

Displays the number of voice cells the Total Access 850 dropped due to a full buffer. This indicates that the network is sending traffic faster than the Total Access 850 is anticipating receiving cells; thus overrunning the jitter buffer. Excess drops could result in a timing mismatch. CLEAR STATS

Clears all recorded statistics and returns all counters to 0.

L2 PROTOCOL (T1 ATM FIRMWARE) – T1 INTERFACE > CUMTN Configure the L2 PROTOCOL parameters and view the status of the T1 interface using Copper Mountain Frame Relay protocol from this menu.

64203376L1-1B

© 2004 ADTRAN, Inc.

139

Page 140

Section 4 User Interface Guide

Total Access 850 System Manual

L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG Configure the L2 PROTOCOL parameters for the T1 interface using Copper Mountain Frame Relay protocol. To insert a new profile, press the I key when over the NUM column. A new inserted profile will always be set up with the default parameters. To copy parameters from an old profile to this newly inserted profile, use the copy (C) and paste (P) keys. Entire configuration trees can be copied with this method.

To delete an unused profile, use the D key when the cursor is over the number in the NUM column. Once deleted, the profile is gone permanently.

L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG > NUM Displays the index number in the DLCI config table. The number range is 0-9.

L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG > ACTIVE When this parameter is set to YES (def), the mapping is used to determine the protocols used. If set to NO, the unit will ignore the virtual circuit with this DLCI.

L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG > INTERFACE Shows the user the physical and logical port associated with each DLCI. This is a read-only field.

L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG > DLCI The DLCI (Data Link Connection Identifier) number identifies the virtual circuit being configured. The DLCI range is 16-1023. The default is 16-25 corresponding to the index numbers 0-9 respectfully.

L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG > CONNECTION Select the physical and logical method of data transfer over the virtual path. There are two valid connection entries: ROUTER and VOICE. Select ROUTER to connect traffic from this PVC to the Total Access 850 integral IP router. Select VOICE to connect traffic from this PVC to a voice connection (normally an FXS interface).

L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG > SETUP This submenu only appears for VOICE connections. Configure the CALL CONTROL for voice gateway using this menu.

L2 PROTOCOL (T1 ATM–T1–CUMTN) > CONFIG > SETUP > CALL CONTROL The CALL CONTROL setting is used to configure the correct Voice Gateway protocol for voice signaling control between the Total Access 850 and the configured Gateway. The Call Control setting must be configured correctly before the voice circuits will work correctly. The Total Access 850 supports JETSTREAM, COPPERCOM, TOLLBRIDGE and LES-CAS (def).

140

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 141

Total Access 850 System Manual

Section 4 User Interface Guide

L2 PROTOCOL (T1 ATM–T1–CUMTN) > STATUS View the status of the Copper Mountain DLCI connections.

L2 PROTOCOL (T1 ATM–T1–CUMTN) > STATUS > NUM Displays the index number for the Status menu entries.

L2 PROTOCOL (T1 ATM–T1–CUMTN) > STATUS > SUB-INTERFACE The T1 SUB-INTERFACE is CuMtn[0.0] when the L2 PROTOCOL is set for CUMTN FRE. The [0.0] represents the T1 physical and logical ports respectively. This is a read-only field.

L2 PROTOCOL (T1 ATM–T1–CUMTN) > STATUS> DLCI STATE This is a read-only field that displays the live DLCI state.

L2 PROTOCOL (T1 ATM–T1–CUMTN) > STATUS > PROTOCOL STATUS This is a read-only field that displays the live protocol status. Menu visible for physical and logical VOICE ports only.

L2 PROTOCOL (T1 ATM–T1–CUMTN) > STATUS > PROTOCOL STATUS > POTS STATS View the voice port activity and coding type.

L2 PROTOCOL (T1 ATM–T1–CUMTN) > STATUS > PROTOCOL STATUS > CLEAR STATS Clears all recorded statistics for the interface and returns all counters to 0.

L2 PROTOCOL (T1 ATM FIRMWARE) – V.35 INTERFACE Configure the L2 PROTOCOL parameters and view the status of the V.35 interface using items from this menu. The V.35 interface is only available when the configured T1 network protocol is ATM. Refer to L2 Protocol (T1 ATM Firmware) – T1 Interface > ATM on page 129.

L2 PROTOCOL (T1 ATM – V35) > PROTOCOL Configure the L2 PROTOCOL mode. Choices are FRF5 (def) and FRF8. Selecting FRF5 configures the interface for network interworking and should be used for Frame Relay over ATM applications. Selecting FRF8 configures the interface for service interworking allowing the Total Access 850 to make the translation between Frame Relay signaling on the V35 interface and ATM protocols on the network interface.

L2 PROTOCOL (T1 ATM – V35) > CONFIG Configures the L2 PROTOCOL parameters for either FRF5 or FRF8 signaling.

64203376L1-1B

© 2004 ADTRAN, Inc.

141

Page 142

Section 4 User Interface Guide

Total Access 850 System Manual

L2 PROTOCOL (T1 ATM – V35) > CONFIG > UNI MAINT PROTOCOL Specifies the maintenance protocol or signaling protocol between the local V.35 port and the attached DTE port. The choices are ANNEX D (def), ANNEX A, LMI, and STATIC.

L2 PROTOCOL (T1 ATM – V35) > CONFIG > UNI POLL TIMEOUT T392 (5-30) T392 for signaling protocol. This parameter has no meaning if the UNI MAINT PROTOCOL is set to STATIC (no signaling). The default setting is 10.

L2 PROTOCOL (T1 ATM – V35)> STATUS Displays the L2 statistics for FRF5 or FRF8 operation.

L2 PROTOCOL (T1 ATM – V35)> STATUS> PORT Displays statistics for all the PVCs configured on this port. The following statistics are available: PORT INDEX

Port number

SIGNAL STATE

Frame relay state

TX FRAMES

Number of frames transmitted

RX FRAMES

Number of frames received

TX BYTES

Number of bytes transmitted

RX BYTES

Number of bytes received

FULL STATUS TX FRAMES

Number of Frame Relay signaling packets transmitted out the port

FULL STATUS RX FRAMES

Number of Frame Relay signaling packets received by the port

LINK INTEGRITY STATUS TX FRAMES

Number of Link Integrity signaling packets transmitted out the port

LINK INTEGRITY STATUS RX FRAMES

Number of Link Integrity signaling received by the port

DROP UNKNOWN DLCI

Number of frames received that were not associated with any known PVC

DROP INVALID DLCI

Number of frames received that had illegal DLCIs

CLEAR STATS

When activated, this field will clear all frame relay port stats

L2 PROTOCOL (V35[2]-ATM)> STATUS> PVC(S) Displays statistics for all the PVCs configured on this port on a PVC basis. The following statistics are available:

142

DLCI

DLCI number

STATE

Frame relay state

TX FRAMES

Number of frames transmitted

RX FRAMES

Number of frames received

RX BYTES

Number of bytes received

DE COUNT

Number of packets received on an individual DLCI with the DE bit set

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 143

Total Access 850 System Manual

Section 4 User Interface Guide

CR COUNT

Number of packets received on an individual DLCI with the CR bit set

BECN COUNT

Number of packets received on an individual DLCI with the BECN bit set

FECN COUNT

Number of packets received on an individual DLCI with the FECN bit set

UNKNOWN FRAME

RX Frames received that were not associated with any PVC entries

L2 PROTOCOL (T1 ATM FIRMWARE) – DSX INTERFACE Configure the L2 PROTOCOL parameters and view the status of the integrated DSX interface using items from this menu.

L2 PROTOCOL (T1 ATM – DSX) > CONFIG Configures the voice parameters for the interface.

INTERFACES (T1 ATM – DSX) > CONFIG > SIGNALING Configures the voice signaling implemented on the interface. The signaling must match the network application. The choices are: E&M (TANDEM)

Sets the DSX interface to use E&M signaling.

LOOP START

Sets the DSX interface to use loop start signaling.

GROUND START

Sets the DSX interface to use ground start signaling.

ISDN PRI

Sets the DSX interface to use common channel signaling for ISDN.

INTERFACES (T1 ATM – DSX) > CONFIG > TX OAM Configures the Total Access 850 to transmit an Operation, Administration, and Maintenance (OAM) cell to the network (voice gateway) when the DSX interface is down.

INTERFACES (T1 ATM – DSX) > CONFIG > RX OAM Configures the Total Access 850 to transmit an alarm condition to the DSX interface when the network (voice gateway) is down.

INTERFACES (T1 ATM – DSX) > CONFIG > LEGACY CONFIG Digital trunk channel ID's are bits used to identify voice calls being carried within ATM cells. Some gateways do not support higher channel IDs, therefore the Total Access 850 supports CIDs from 16 or 65. The default is DSX CID FROM 65.

64203376L1-1B

© 2004 ADTRAN, Inc.

143

Page 144

Section 4 User Interface Guide

Total Access 850 System Manual

L2 PROTOCOL (ALL FIRMWARE) – ETH INTERFACE > 802.3 PROTOCOL Configure the L2 PROTOCOL parameters and view the status of the Ethernet interface from this menu.

L2 PROTOCOL (ALL–ETH–802.3) > PROTOCOL Displays the L2 PROTOCOL for the 10/100BaseT Ethernet port. Currently only 802.3 is supported.

L2 PROTOCOL (ALL–ETH–802.3) > CONFIG Configure the mode for this 10/100BASET Ethernet port from this menu.

L2 PROTOCOL (ALL–ETH–802.3) > CONFIG > MODE The mode identifies how the data will be forwarded. The choices are: ROUTE IP (def)

All IP data will be routed

BRIDGE ALL

All data will be bridged

ROUTE IP/BRIDGE OTHER

All IP data will be routed. All other data will be bridged.

L2 PROTOCOL (ALL–ETH–802.3) > STATUS View the L2 PROTOCOL statistics for the 10/100BASET Ethernet port from this menu.

L2 PROTOCOL (ALL–ETH–802.3) > STATUS > TX PACKETS Total number of packets transmitted out the Ethernet port.

L2 PROTOCOL (ALL–ETH–802.3) > STATUS > RX PACKETS Total number of packets received from the Ethernet port.

L2 PROTOCOL (ALL–ETH–802.3) > STATUS > TX ERRORS Total number of transmit errors encountered on Ethernet port.

L2 PROTOCOL (ALL–ETH–802.3) > STATUS > SINGLE COLLISIONS Total number of single collisions before successful transmission.

L2 PROTOCOL (ALL–ETH–802.3) > STATUS > MULTIPLE COLLISIONS Total number of multiple collisions before successful transmission.

L2 PROTOCOL (ALL–ETH–802.3) > STATUS > EXCESSIVE COLLISIONS Total number of collisions that resulted in packet being dropped.

L2 PROTOCOL (ALL–ETH–802.3) > STATUS > DEFERRED TRANSMISSIONS Total number of packets deferred due to collisions.

L2 PROTOCOL (ALL–ETH–802.3) > STATUS > CARRIER SENSE ERRORS Total number of carrier sense errors encountered (no link integrity).

144

© 2004 ADTRAN, Inc.

64203376L1-1B