Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Total Access 850 System Manual

Manual · Adtran

Total Access 850 System Manual

Manual292 pagesPDF 3.7 MB

System manual for the ADTRAN Total Access 850 chassis (1200375L1) and its controller units, power supplies and access modules.

Download the PDF3.7 MB

Covers · 1 model

The models it covers

Summary

What is in it

ADTRAN's system manual for the Total Access 850, covering the 1200375L1 chassis, T1 Bank Controller Units, T1 and SDSL Router Control Units, the echo canceler, power supplies and access modules such as Quad FXS, Quad FXO and DSX-1. It gives a system description, engineering guidelines (dimensions, power, front and rear panels), the network turnup procedure, a guide to the VT100 menus, step-by-step procedures for login, IP setup, firmware updates and configuration transfers, the ADTRAN utilities and the supported MIBs.

Its parts

  1. System Description
  2. Engineering Guidelines
  3. Network Turnup Procedure
  4. User Interface Guide
  5. Detail Level Procedures
  6. ADTRAN Utilities
  7. MIBs

From the manual

Key facts from this manual

Each line names its page in the PDF.

ADTRAN Total Access 850 System Manual, document 64203376L1-1B of August 2004. It covers the Total Access 850 Chassis (1200375L1) and its modules, including the BCU 1200373L1 and 1200373L2, the T1 and SDSL RCUs, the Power Supply Unit 1175006L2 and the AC Supply/Battery Charger 1175043L3. This summary draws on the system description, the engineering guidelines and the installation pages, for choosing modules, wiring, powering and mounting the chassis.

Read for this summary: pages 1 to 3, 17 to 21, 25 to 28, 33 to 35 and 58 to 61 of 292.

Device type
Modular integrated access device for voice and data services at the customer premises p. 17
Slots
Two common slots, six access slots and two slots for special access modules p. 17
Dimensions
8.5 in W, 11 in D, 3.5 in H (2U) p. 17, 25
AC power
90/130 VAC, 50 Watt max p. 25
DC power
40/56 VDC, 50 Watt max p. 25
Power inputs
P6 4-pin jack for an ADTRAN AC/DC power supply and battery charger (for example P/N 1175043Lx); P7 3-lug terminal for -48 VDC on site p. 34, 58
System modules
BCU 1200373L1; BCU with Fractional T1 1200373L2; T1 RCU 4203376L1#TDM or 4203376L1#ATM; 3rd Generation T1 RCU 1203376L1; SDSL RCU 1200377L1 and 1200377L2; Power Supply Unit 1175006L2 p. 18
Access modules
Quad FXS 1175408L2; Quad FXO 1175407L2; UBR1TE 1180020L1; Dual V.35 1180025L1; DSX-1 1200385L1 p. 18
BCU-only modules
E&M/TO 1180402L1; OCU DP 1180005L1; Single DS0 DP 1180003L1; Nx56/64 (V.35) 1200372L1 p. 19
Rear connectors
JP2 RJ-48 primary T1; JP3 RJ-48 DSX1; JP1 RJ-48 10BaseT Ethernet; JP4 RJ-48 EIA-232 craft; J1 V.35; P2 50-pin amphenol for FXO, FXS p. 34
Management
VT100 emulation; SNMP and Telnet with an RCU; dial-up via an external analog modem p. 17
Rack brackets
1175045L1 for 19 inch racks, 1175046L1 for 23 inch racks; wallmount brackets included p. 60
Blank panel
P/N 1175099L1 for empty slots p. 25
Max ambient temperature
45 ºC recommended maximum p. 58

What this manual walks you through

  • Choosing system, resource and access modules p. 18, 19, 20, 21
  • Reading the BCU faceplate LEDs p. 26
  • Setting BCU DIP-switch S1 for framing, line code, timing and line build out p. 26, 27
  • Using the BCU bantam jacks and DB-9 TEST connector p. 28
  • Rear panel connections and T1, Ethernet pinouts p. 33, 34, 35
  • Grounding the chassis p. 58
  • Supplying AC or DC power and making alternate power connections p. 58, 59
  • Wallmounting or rack mounting the chassis p. 60
  • Installing the power supply unit p. 61

Good to know

  • Replacing an access module with a different module type loses its configuration; same-type replacement restores it. p. 19
  • The Ethernet LAN interface is for intra-building networks only, not public networks. p. 34
  • Only one of the two T1 connection points is used; when the T1 is wire-wrapped on P3, a blank plug goes in JP2. p. 35
  • Before removing the rear cover, remove the 20 Hz fuse (PSU 1175006L1) or press Ring Enable to isolate ring voltage (PSU 1175006L2). p. 33
  • DC branch circuit protection must be a fuse or breaker rated at least 48 VDC and at most 20A. p. 59

Questions this manual answers

What power does the Total Access 850 chassis need?

AC systems take 90/130 VAC and DC systems 40/56 VDC, each 50 Watt maximum. p. 25

How big is the Total Access 850 chassis?

It is 8.5 inches wide, 11 inches deep and 3.5 inches high, and fits 19-inch or 23-inch racks. p. 25

Which rack mount brackets fit the Total Access 850?

Part number 1175045L1 for a 19 inch rack or 1175046L1 for a 23 inch rack; wallmount brackets come with the chassis. p. 60

Which Total Access 850 access modules need a BCU?

The E&M/TO, OCU DP, Single DS0 DP and Nx56/64 (V.35) access modules require a Bank Controller Unit. p. 19

Are Total Access 850 access modules hot-swappable?

Yes, each access module is hot-swappable and its configuration is restored on replacement, unless a different module type is fitted. p. 19

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. System Description15
    1. 1. System Overview17
    2. 2. Features and Benefits17
    3. 3. Modules18
  2. Engineering Guidelines23
    1. 1. Equipment Dimensions25
    2. 2. Power Requirements25
    3. 3. Reviewing the Front Panel Design25
    4. 4. Reviewing the Rear Panel Design33
    5. 5. Access Module Interfaces40
  3. Network Turnup Procedure55
    1. 1. Introduction56
    2. 2. Tools Required56
    3. 3. Unpack and Inspect the System56
    4. 4. Telecommunications Codes57
    5. 5. Grounding Instructions57
    6. 6. Supplying Power to the Unit58
    7. 7. Mounting Options60
    8. 8. Installing Modules61
    9. 9. Module Shipping Contents62
  4. User Interface Guide65
    1. 1. Navigating the Terminal Menu67
    2. 2. Main Menu and System Control71
    3. 3. Menu Descriptions72
    4. 4. Appendices (T1 TDM Applications)182
    5. 5. Appendices (T1 ATM Applications)199
  5. Detail Level Procedures213
    1. DLP-1 Connecting a VT100 Terminal or PC to the CRAFT Port215
    2. DLP-2 Logging in to the System217
    3. DLP-3 Setting IP Parameters for the Total Access 850219
    4. DLP-4 Verifying Communications Over an IP LAN221
    5. DLP-5 Connecting to the Total Access 850 Using Telnet225
    6. DLP-6 Adding/Removing Users and Changing Password Security Levels229
    7. DLP-7 Updating the Firmware using TFTP233
    8. DLP-8 Updating the Firmware using XMODEM237
    9. DLP-9 Saving the Current Configuration Using TFTP239
    10. DLP-10 Loading a Configuration Using TFTP241
    11. DLP-11 Saving and Transferring a Current Configuration Using XMODEM245
    12. DLP-12 Loading a Configuration Using XMODEM247
21 more lines, from page 249 on
  1. DLP-13 Saving and Loading Text Configuration using Terminal Command Line249
    1. DLP-14 A.03 to A.04 Firmware Upgrade253
    2. DLP-15 Using the ADTRAN Utility Syslog257
    3. DLP-16 Connecting the Alarm Contacts and the External Input261
    4. DLP-17 Configuring the Total Access 850 for Dual T1 Maps265
  2. ADTRAN Utilities269
    1. 1. Telnet Utility270
    2. 2. VT100 Utility273
    3. 3. TFTP Server275
    4. 4. Status Field277
    5. 5. Meter Field277
    6. 6. Log Field277
  3. MIBs279
    1. 1. MIBs Supported by TDM Units280
    2. 2. MIB Compilation Order For TDM Units281
    3. 3. Traps Supported by TDM Units281
    4. 4. MIB Variables Supported by TDM Units282
    5. 5. MIBs Supported by ATM Units282
    6. 6. MIB Compilation order for ATM Units283
    7. 7. Traps Supported by ATM Units283
    8. 8. MIB Variables Supported by ATM Units283

From the PDF’s own bookmarks.

The whole text · 30 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 121-12
  2. Pages 13 to 2213-22
  3. Engineering Guidelines, pages 23 to 3023-30
  4. Engineering Guidelines, pages 31 to 3831-38
  5. Engineering Guidelines, pages 39 to 4639-46
  6. Engineering Guidelines, pages 47 to 5447-54
  7. Network Turnup Procedure55-64
  8. User Interface Guide, pages 65 to 7465-74
  9. User Interface Guide, pages 75 to 8475-84
  10. User Interface Guide, pages 85 to 9485-94
  11. User Interface Guide, pages 95 to 10495-104
  12. User Interface Guide, pages 105 to 114105-114
  13. User Interface Guide, pages 115 to 124115-124
  14. User Interface Guide, pages 125 to 134125-134
  15. User Interface Guide, pages 135 to 144135-144
  16. User Interface Guide, pages 145 to 154145-154
  17. User Interface Guide, pages 155 to 164155-164
  18. User Interface Guide, pages 165 to 174165-174
  19. User Interface Guide, pages 175 to 184175-184
  20. User Interface Guide, pages 185 to 194185-194
  21. User Interface Guide, pages 195 to 204195-204
  22. User Interface Guide, pages 205 to 212205-212
  23. Detail Level Procedures, pages 213 to 222213-222
  24. Detail Level Procedures, pages 223 to 232223-232
  25. Detail Level Procedures, pages 233 to 242233-242
  26. Detail Level Procedures, pages 243 to 252243-252
  27. Detail Level Procedures, pages 253 to 262253-262
  28. Detail Level Procedures, pages 263 to 268263-268
  29. ADTRAN Utilities269-278
  30. MIBs279-292

The file

Revision and size

Part no.64203376L1-1B
RevisionAugust 2004
PublisherADTRAN
Pages292
PDF3.7 MB
TextText from the PDF itself.
64203376L1-1B

The first pages · 3 of 292

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 292
Page 2
Page 2of 292
Page 3
Page 3of 292