Page 243
Total Access 850 System Manual
Section 5 DLP-10
10. When the upload process has successfully completed, IDLE displays in the CURRENT TRANSFER STATUS field and DOWNLOAD COMPLETE displays in the PREVIOUS TRANSFER STATUS field. 11. After an appropriate length of time, the user may Telnet back into the unit.
64203376L1-1B
© 2004 ADTRAN, Inc.
243
Page 244
Section 5 DLP-10
244
Total Access 850 System Manual
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 245
DLP-11 Saving and Transferring a Current Configuration Using XMODEM Introduction The Total Access 850 supports configuration transfers from the unit via the rear CRAFT or RCU faceplate CRAFT interfaces using a VT100 terminal or terminal emulator (with XMODEM). This DLP provides the steps for a successful configuration transfer using either the rear CRAFT or RCU faceplate CRAFT port and XMODEM.
Tools and Materials Required • •
VT100 terminal or PC with VT100 terminal emulation software XMODEM software
To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.
Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.
64203376L1-1B
© 2004 ADTRAN, Inc.
245
Page 246
Section 5 DLP-11
Total Access 850 System Manual
Perform the following steps in the order listed. 1. Connect to the Total Access 850 using the rear CRAFT (RJ-45) port on the back of the Total Access 850 or the RCU faceplate CRAFT (DB-9) interface.
If you are not already connected to the unit’s rear CRAFT or RCU faceplate CRAFT interface, either with a VT100 compatible terminal or with a PC running VT100 emulation software, follow the procedure in DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port. Connecting to the rear CRAFT or RCU faceplate CRAFT interface limits the configuration transfer procedure to XMODEM only. 2. Log in to the unit. 3. Go to the SYSTEM UTILITY menu and select CONFIGURATION TRANSFER menu; press <Enter>. 4. Set the TRANSFER METHOD menu to XMODEM. 5. Select SAVE CONFIG REMOTELY to start the transfers. Enter Y to confirm the transfer and prepare the Total Access 850 for the transfer download.
The following message is displayed: This will begin sending a copy of the current system configuration. 6. Configure the VT100 terminal or terminal emulation software to RECEIVE (and prompt for a filename). 7. View the CURRENT TRANSFER STATUS to verify the progress of the current transfer. 8. From the terminal emulation software, begin the XMODEM transfer by using the appropriate command sequence. For Windows HyperTerminal, select TRANSFER>RECEIVE FILE. Enter the filename (including path) and select XMODEM as the transfer method.
If necessary, refer to the terminal emulation software documentation for help. When specifying the filename, ensure that the saved file has a .cfg extension; otherwise, the file may not be available for uploading into other Total Access 850 units. Because XMODEM data is being transferred inband through the menu interface, the VT100 menus of the Total Access 850 will be inoperable from the rear CRAFT or RCU faceplate CRAFT interfaces. You can cancel the update at any time within the terminal emulation software. (Please consult the documentation provided by the terminal emulation software to determine how to do this.) 9. When the transfer has successfully completed, IDLE displays in the CURRENT TRANSFER STATUS field and XMODEM DOWNLOAD COMPLETE displays in the PREVIOUS TRANSFER STATUS field.
246
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 247
DLP-12 Loading a Configuration Using XMODEM Introduction The Total Access 850 supports configuration uploads from a unit via the rear CRAFT or RCU faceplate CRAFT interface using a VT100 terminal or terminal emulator (with XMODEM). This DLP provides the steps for a successful configuration upload using either the rear CRAFT or RCU faceplate CRAFT port and XMODEM protocol.
Tools and Materials Required • •
VT100 terminal or PC with VT100 terminal emulation software XMODEM software
To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.
Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.
64203376L1-1B
© 2004 ADTRAN, Inc.
247
Page 248
Section 5 DLP-12
Total Access 850 System Manual
Perform the following steps in the order listed. 1. Connect to the Total Access 850 using the rear CRAFT (RJ-45) or the RCU faceplate CRAFT (DB-9) interface located on the front of the RCU.
If you are not already connected to the unit’s rear CRAFT or RCU faceplate CRAFT interface, either with a VT100 compatible terminal or with a PC running VT100 emulation software, follow the procedure in DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port. Connecting to the rear CRAFT or RCU faceplate CRAFT interface limits the configuration transfer procedure to XMODEM only. 2. Log in to the unit using the read-write password (see DLP-2, Logging in to the System, for details). 3. Go to the SYSTEM UTILITY menu and select CONFIGURATION TRANSFER menu; press <Enter> 4. Set the TRANSFER METHOD menu to XMODEM. 5. Select LOAD AND USE CONFIG to start the transfer. Enter Y to confirm the transfer and prepare the Total Access 850 for the transfer download.
The Total Access 850 system is rebooted immediately after a configuration is successfully loaded. No additional confirmation is requested, and any online sessions will be terminated. When the Total Access 850 is ready to receive the XMODEM configuration file, the menu screen clears and displays AWAITING XMODEM UPLOAD....<CTRL+X> TWICE TO CANCEL. If this does not appear, please review the preceding steps above for possible configuration errors. 6. From the terminal emulation software, begin the XMODEM transfer by using the appropriate command sequence. For Windows HyperTerminal, select TRANSFER>SEND FILE. Enter the filename (including path) and select XMODEM as the transfer method. Total Access 850 configuration files should have a .cfg extension.
If necessary, refer to the terminal emulation software documentation for help. Because XMODEM data is being transferred inband through the menu interface, the VT100 menus of the Total Access 850 will be inoperable during this procedure from the rear CRAFT or RCU faceplate CRAFT interfaces. You can cancel the update at any time within the terminal emulation software. (Please consult the documentation provided by the terminal emulation software to determine how to do this.) 7. View CURRENT TRANSFER STATUS to verify the progress of the current upload. 8. When the transfer is complete, the Total Access 850 reboots and the LOGIN screen appears. The unit is now operational.
248
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 249
DLP-13 Saving and Loading Text Configuration using Terminal Command Line Introduction The Total Access 850 RCU has the ability to download a text file which contains the configuration of the entire unit. This configuration may then be altered in a text editor and uploaded to any Total Access 850 RCU. This DLP will explain how to save and load the text configuration file for the ADTRAN Total Access 850.
Prerequisite Procedures You must connect to the Total Access 850 with a VT100 terminal session (reference DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port).
To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.
Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.
64203376L1-1B
© 2004 ADTRAN, Inc.
249
Page 250
Section 5 DLP-13
Total Access 850 System Manual
Perform the steps below in the order listed.
Saving the router's configuration 1. Establish a connection to the router with the VT100 terminal software either through the rear CRAFT or RCU faceplate CRAFT port. 2. From the main menu, select SYSTEM UTILITY, then TERMINAL MODE; press <Enter>. 3. The following screen appears.
4. At the terminal prompt, type DOWNLOAD; press <Enter>. The following screen appears. *
Do not enter further key commands until completing Step 5.
250
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 251
Total Access 850 System Manual
Section 5 DLP-13
5. Enable "capture" or "logging" in the terminal software, saving it to a file on your computer. 6. Press the SPACE BAR to continue. The router will then print its configuration to the terminal screen. (With capture enabled, the terminal software will capture the configuration and write it to the designated file.) 7. When the configuration stops printing, end the capture. The router's configuration is now saved to the designated file. 8. At the terminal prompt, type EXIT to enter the configuration menu of the router.
Always use <CTRL+L> to exit the configuration menu before closing the Telnet or terminal software.
Loading a configuration into the router The following steps explains the process for uploading the text file back into the Total Access 850 RCU. These text files can be the entire configuration, or just partial commands that affect specific configuration changes. The uploading steps are the same, regardless of the size of the file. 1. Establish a connection to the router with the VT100 terminal software either through the rear CRAFT or RCU faceplate CRAFT port. 2. From the main menu, select SYSTEM UTILITY, then TERMINAL MODE; press <Enter>. 3. In the terminal software, initiate a SEND TEXT FILE or SEND CFG FILE using the saved configuration file. 4. Once the file transfer is complete, type SAVE to save the configuration in the unit. Type EXIT to enter the configuration menu of the router.
Always use <CTRL+L> to exit the configuration menu before closing the Telnet or terminal software.
Entering commands at the command prompt Precede each instruction with a ">" when manually entering commands at the command prompt. After entering commands, type SAVE at the command prompt. (This applies ALL commands to current operation and saves all changes.) To save the changes to flash only (without affecting current operation), return to the menu system and press <CTRL+W>. The commands are based on string comparisons with the menu system (with spaces replaced with underscores). For example, the config command appears at the command prompt exactly as it appears in the RCU terminal menus. To change a configuration, type in the desired option exactly as it appears on the menu. For example, to change the T1 timing mode, the command line should read >sysconfig t1_timing_mode network (sets timing to recover from the network) or >sysconfig t1_timing_mode internal (sets timing to internal Total Access 850 oscillator) or >sysconfig t1_timing_mode dsx-1 (sets timing to recover from the DSX-1 interface).
64203376L1-1B
© 2004 ADTRAN, Inc.
251
Page 252
Section 5 DLP-13
252
Total Access 850 System Manual
© 2004 ADTRAN, Inc.
64203376L1-1B