Page 233

DLP-7 Updating the Firmware using TFTP Introduction The Total Access 850 supports firmware updates using TFTP or XMODEM. (Use the 10/100BASET Ethernet port and TFTP from a network server, or use XMODEM and the RCU faceplate CRAFT or rear CRAFT interfaces.) This DLP provides the steps for a successful firmware upgrade using the 10/100BASET Ethernet port and a TFTP server. (See DLP-8, Updating the Firmware using XMODEM, for instructions on using XMODEM.)

Tools and Materials Required • •

A PC with Telnet client software A TFTP server accessible on the local network

A TFTP server is provided as part of the ADTRAN Utilities software suite supplied with your shipment.

To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.

Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.

64203376L1-1B

© 2004 ADTRAN, Inc.

233

Page 234

Section 5 DLP-7

Total Access 850 System Manual

Perform the steps below in the order listed.

1. Connect to the Total Access 850 using the 10/100BASET interface.

If you are not already connected to the unit’s ETHERNET port using Telnet client software, use the procedure in DLP-5, Connecting to the Total Access 850 Using Telnet, to connect to the unit. 2. Log in to the unit using the read-write password (see DLP-2, Logging in to the System for details). 3. Verify the TFTP server is running on the network. The user may ping the TFTP server from the Total Access 850 to verify communication.

A TFTP server ships as part of the ADTRAN Utilities. If using ADTRAN Utilities, choose START > PROGRAMS > ADTRAN UTILITIES > TFTP SERVER to start the server.

4. Download the firmware upgrade file to your computer.

If using ADTRAN Utilities, save the upgrade file to the “ADTNUTIL” directory on your hard drive.

5. Go to the SYSTEM UTILITY menu and select the UPDATE FIRMWARE menu; press <Enter>. 6. Go to the TRANSFER METHOD menu and select TFTP. 7. Set the TFTP SERVER ADDRESS to the IP address of the machine running the TFTP server program.

If using ADTRAN Utilities, this will be the IP address that appears in the TFTP SERVER STATUS window.

8. Enter the filename of the update file into the TFTP SERVER FILENAME field. If the file is located in a directory other than ADTNUTIL, the entire path and filename are required.

234

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 235

Total Access 850 System Manual

Section 5 DLP-7

9. Select START TRANSFER to start the update. Enter Y to confirm the upgrade.

Prior to the start of the upgrade, the transfer status will display IDLE. During the TFTP upload process, various status messages display in CURRENT UPDATE STATUS to indicate progress. The following table describes these messages. Message

Meaning

Indicates communication with the TFTP network server has been Transferring... [X KB] established and the update file is being transferred between the Total Access 850 and the TFTP network server. Flash Programmed Successfully

The unit has been upgraded successfully.

Loaded code ver x.x.x chksum = xxxx

Unit displays the version and checksum of the upgraded code.

Resetting ....

Unit is power cycling.

RECV Error

Unit will display this message if server filename is incorrect.

Can not start tftp client **Reload

Unit will display this message if TFTP server address is incorrect.

Transfer aborted

User has selected ABORT TRANSFER.

10. When the update has successfully completed, FLASH PROGRAMMED SUCCESSFULLY displays briefly in the TRANSFER STATUS field. This will be followed by a LOADED CODE VER X.X.X CHKSUM = XXXX message. Finally the TRANSFER STATUS field displays RESETTING ...

The Total Access 850 will restart immediately and resume operation. After giving the unit sufficient time to reboot, the user may Telnet back into the unit and log in.

64203376L1-1B

© 2004 ADTRAN, Inc.

235

Page 236

Section 5 DLP-7

236

Total Access 850 System Manual

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 237

DLP-8 Updating the Firmware using XMODEM Introduction The Total Access 850 supports firmware updates using TFTP or XMODEM. (Use the 10/100BASET Ethernet port and TFTP from a network server, or use XMODEM and the rear CRAFT or RCU faceplate CRAFT interface.) This procedure outlines the steps for a successful firmware upgrade using the rear CRAFT or RCU faceplate CRAFT interface and XMODEM software. (See DLP-7, Updating the Firmware using TFTP, for instructions on using TFTP.)

Tools and Materials Required •

VT100 compatible terminal or computer with terminal emulation software

•

XMODEM software To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.

Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.

64203376L1-1B

© 2004 ADTRAN, Inc.

237

Page 238

Section 5 DLP-8

Total Access 850 System Manual

Updating Firmware via the Console Menus Perform the steps below in the order listed.

1. Connect to the Total Access 850 using the RCU faceplate CRAFT (DB-9) or rear CRAFT (RJ-45) interface. Selecting a higher baud rate connection makes the file transfer process faster. Verify that the baud rate setting on the Total Access 850 matches the VT100 emulation software COM port settings.

If you are not already connected to the shelf’s RCU faceplate CRAFT or rear CRAFT interface (either with a VT100 compatible terminal or with a PC running VT100 emulation software), follow the procedure in DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port. Connecting to the RCU faceplate CRAFT or rear CRAFT interface limits the upgrade procedure to XMODEM only. 2. Log in to the unit. 3. Go to the SYSTEM UTILITY menu and select the UPGRADE FIRMWARE menu; press <Enter>. 4. Go to the TRANSFER METHOD menu and select XMODEM.

Total Access 850 XMODEM transfers are compatible with 1K XMODEM on the VT100 terminal system. Selecting 1K XMODEM on your terminal session will make the configuration transfer faster. 5. Select START TRANSFER to start the update process. Enter Y to confirm the upgrade. 6. From the terminal emulation software, begin the XMODEM upload by using the appropriate command sequence. If necessary, refer to the terminal emulation software documentation for help.

Also, when specifying the filename, ensure that the file transferred is the one provided by ADTRAN, otherwise, the update will not complete successfully. This may take several minutes. Because XMODEM data is being transferred in-band through the menu interface, the VT100 menus of the Total Access 850 will be inoperable from the RCU faceplate CRAFT or rear CRAFT interface. You can cancel the update at any time within the terminal emulation software. (Please consult the documentation provided by the terminal emulation software to determine how to do this.) 7. When the update process has successfully completed, the following messages will display: Verifying downloaded FLASH image... Erasing FLASH... Programming FLASH... FLASH programmed successfully.

The Total Access 850 will restart immediately and the user may then log back into the system. Alternately, if the unit is part of a management cluster connected to the local network, you may use a PC connected to the network to Telnet into the unit. By utilizing the ETHERNET port, the Total Access 850 may be quickly upgraded using TFTP, provided there is a TFTP server on the local network. The Total Access 850 ships with ADTRAN Utilities software, which includes a TFTP server. See DLP-7, Updating the Firmware using TFTP, for more details.

238

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 239

DLP-9 Saving the Current Configuration Using TFTP Introduction The Total Access 850 supports configuration transfers from the unit (via the 10/100BASET Ethernet port) to a TFTP server located on the network. This DLP provides the steps to follow for a successful configuration transfer using the 10/100BASET Ethernet port and a TFTP Server.

Tools and Materials Required • •

A PC with a Telnet client software A TFTP Server accessible on the local network (A TFTP server is provided with the unit as part of the ADTRAN Utilities software.) To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.

Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.

64203376L1-1B

© 2004 ADTRAN, Inc.

239

Page 240

Section 5 DLP-9

Total Access 850 System Manual

Perform the steps below in the order listed.

1. Connect to the Total Access 850 using the 10/100BASET interface.

If you are not already connected to the unit’s 10/100BASET port using Telnet client software, use the procedure in DLP-5, Connecting to the Total Access 850 Using Telnet, to connect to the unit. 2. Log in to the unit using the read-write password (see DLP-2, Logging in to the System, for details). 3. Verify the TFTP server is running on the network.

A TFTP server ships as part of the ADTRAN Utilities. If using ADTRAN Utilities, choose START > PROGRAMS > ADTRAN UTILITIES > TFTP SERVER to start the server.

4. Go to the SYSTEM UTILITY menu and select the CONFIGURATION TRANSFER menu; press <Enter>. 5. Verify the TRANSFER METHOD is set to TFTP. 6. Set the TFTP SERVER IP ADDRESS to the IP address of the machine running the TFTP Server Program.

If you are using the ADTRAN TFTP server, the IP address displays in the STATUS field. For other TFTP servers, please refer to the appropriate documentation.

7. Change TFTP SERVER FILENAME to a unique filename (for example, ta850.cfg). This will be the name of the configuration file saved to the remote server.

Some TFTP servers constrain the format of the filename depending on the operating system of the server. For example, a TFTP server running on a PC under Windows 3.1 may only permit 8.3 format filenames (8 characters, period and three extension characters). 8. Select the SAVE CONFIG REMOTELY menu field and press <Enter>. Respond with Y to confirm the request. 9. View CURRENT TRANSFER STATUS to verify the progress of the current transfer. During a successful transfer, you will first see DOWNLOAD: COPYING INTERNAL CONFIG, and then DOWNLOAD IN PROGRESS.... 10. When the transfer process has successfully completed, IDLE displays in the CURRENT TRANSFER STATUS field and DOWNLOAD COMPLETE displays in the PREVIOUS TRANSFER STATUS field.

TFTP is not secure. No passwords are required for client access. Anyone can access files through the IP port on the server machine if they know the target filename.

240

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 241

DLP-10 Loading a Configuration Using TFTP Introduction The Total Access 850 supports configuration uploads from a unit (via the 10/100BASET Ethernet port) to a TFTP server located on the network. This DLP provides the steps to follow for a successful configuration upload using the 10/100BASET Ethernet port and a TFTP Server.

Tools and Materials Required • •

A PC with a Telnet client software A TFTP Server accessible on the local network (A TFTP server is provided with the unit as part of the ADTRAN Utilities software.) To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.

Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.

64203376L1-1B

© 2004 ADTRAN, Inc.

241

Page 242

Section 5 DLP-10

Total Access 850 System Manual

Perform the steps below in the order listed.

1. Connect to the Total Access 850 using the 10/100BASET interface.

If you are not already connected to the unit’s 10/100BASET port using Telnet client software, use the procedure in DLP-5, Connecting to the Total Access 850 Using Telnet, to connect to the unit. 2. Log in to the unit using the read-write password (see DLP-2, Logging in to the System, for details). 3. Verify the TFTP server is running on the network.

A TFTP server ships as part of the ADTRAN utilities. If using ADTRAN utilities, choose START > PROGRAMS > ADTRAN UTILITIES > TFTP SERVER to start the server.

4. Go to the SYSTEM UTILITY menu and select the CONFIGURATION TRANSFER menu; press <Enter>. 5. Verify the TRANSFER METHOD is set to TFTP.

TFTP is not secure. No passwords are required for client access. Anyone can access files through the IP port on the server machine if they know the target file’s name.

6. Set the TFTP SERVER IP ADDRESS to the IP address of the machine running the TFTP Server Program.

If you are using the ADTRAN TFTP server, the IP address displays in the STATUS field. For other TFTP servers, please refer to the appropriate documentation.

7. Change TFTP SERVER FILENAME to a unique filename. (This will be the name of the configuration file retrieved from the remote server.) If the ADTRAN Utilities TFTP server is used and no path is specified, the configuration file is retrieved from the default ADTNUTIL directory. To retrieve a configuration file from a particular folder, enter the entire filename including path.

Some TFTP servers constrain the format of the filename depending on the operating system of the server. For example, a TFTP server running on a PC under Windows 3.1 may only permit 8.3 format filenames (8 characters, period and three extension characters). 8. Select the LOAD AND USE CONFIG menu field and press <Enter>. Respond with Y to confirm the request.

The Total Access 850 system is rebooted immediately after a configuration is successfully loaded. No additional confirmation is requested, and any online sessions will be terminated. 9. View CURRENT TRANSFER STATUS to verify the progress of the current upload.

242

© 2004 ADTRAN, Inc.

64203376L1-1B