The text of a manual · part 24 of 30
Total Access 850 System Manual: Detail Level Procedures, pages 223 to 232
Pages 223 to 232 of 292, from Total Access 850 System Manual
The original document is the PDF (3.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Adtran 1200375L1
Page 223
Total Access 850 System Manual
Section 5 DLP-4
From the same computer used in the previous step, Telnet to the Total Access 850 and verify that the Telnet session is properly opened (see DLP-5, Connecting to the Total Access 850 Using Telnet). Once the Telnet session is established, press <CTRL+L> to logout and close the session. Refer to the documentation of the computer system if you are unsure how to perform a Telnet. Most computers running a networked version of Microsoft Windows™ or UNIX allow a Telnet to be performed by simply typing Telnet <IP Address> at a command line prompt. Telnet is a utility common on many local area networks that allows remote access to another computer or piece of equipment.
64203376L1-1B
© 2004 ADTRAN, Inc.
223
Page 224
Section 5 DLP-4
224
Total Access 850 System Manual
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 225
DLP-5 Connecting to the Total Access 850 Using Telnet Introduction The Total Access 850 comes pre-programmed for default Telnet access. The following IP parameters apply: • IP Address: 10.0.0.1 • Subnet Mask: 255.255.255.0 • User: guest • Password: password For security purposes, change the default Telnet password during the initial unit configuration. (Refer to System Config > Management > Telnet Access > User List on page 77 for more details.) If the Total Access 850 is part of a management cluster connected to the local network, you may use a PC connected to the network to Telnet into the unit. This procedure details the steps which must be performed to Telnet into the unit.
Prerequisite Procedures Complete DLP-3, Setting IP Parameters for the Total Access 850 and DLP-4, Verifying Communications Over an IP LAN.
Tools and Materials Required •
Access to a PC or other computer connected to the LAN.
To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.
Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.
64203376L1-1B
© 2004 ADTRAN, Inc.
225
Page 226
Section 5 DLP-5
Total Access 850 System Manual
Perform the steps below in the order listed.
1. Connect the computer to the Total Access 850 RCU faceplate CRAFT or rear CRAFT port (details in DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port). 2. Log in to the unit. 3. Select the SYSTEM CONFIG/MANAGEMENT/TELNET ACCESS menu and set the TELNET ACCESS to ON. 4. Under the SYSTEM CONFIG/MANAGEMENT/TELNET ACCESS menu, select the TELNET USER LIST; press <Enter>. The following screen appears.
5. Use the right arrow key to select the NAME field; press <Enter>. Enter a username to use for Telnet logins. 6. Use the right arrow key to select PASSWORD; press <Enter>. Enter a password to use for Telnet logins. 7. Use the right arrow key to select IDLE TIME (MINS); press <Enter>. This field defines the amount of time in minutes the Telnet session may be idle before the user is logged off. The range is 1-255 and the default value is 10 minutes. Enter the appropriate IDLE TIME. 8. Use the right arrow key to select LEVEL; press <Enter>. Select the appropriate security level. (Reference DLP-6, Adding/Removing Users and Changing Password Security Levels, for security level definitions.) 9. Press the left arrow key until prompted to save the Telnet changes. Respond with Y to confirm the request. 10. This completes the addition of one Telnet user. Repeat steps 1-11 for each additional Telnet user access. 11. Press <CTRL+L> to log off the Total Access 850 terminal menu system.
226
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 227
Total Access 850 System Manual
Section 5 DLP-5
12. From a remote computer system connected to the LAN, Telnet to the Total Access 850.
Refer to the documentation of the computer system if you are unsure how to perform a Telnet. Most computers running a networked version of Microsoft Windows™ or UNIX allow a Telnet to be performed by simply typing “Telnet <IP Address>” at a command line prompt. Telnet is a utility common on many local area networks that allows remote access to another computer or piece of equipment. The following screen appears.
13. Enter the user name assigned in step 5 and press enter. The following screen appears.
64203376L1-1B
© 2004 ADTRAN, Inc.
227
Page 228
Section 5 DLP-5
Total Access 850 System Manual
14. Enter the password assigned in step 6.
After entering the correct password, the Total Access 850 main menu is displayed (see below):
15. After completing your configuration changes they are automatically saved (or manually save them by pressing <CTRL+W>), press <CTRL+L> to log off the menus, and close the Telnet window.
228
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 229
DLP-6 Adding/Removing Users and Changing Password Security Levels Introduction Password security levels only apply to users connecting to the Total Access 850 system through Telnet access. All connections made through the CRAFT interface ALWAYS have maximum security rights. All menu items in the Total Access 850 are protected by passwords of varying security levels. By assigning different passwords to different security levels, the Total Access 850 System Administrator can control which users can view or change various menu items. You can assign multiple passwords at the same access level. This way, different users with the same access privileges can have different passwords. This procedure details the steps which must be performed to add/remove user profiles and assign password security levels in the Total Access 850.
Tools and Materials Required •
VT100 compatible terminal or PC with VT100 terminal emulation software
To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.
Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.
64203376L1-1B
© 2004 ADTRAN, Inc.
229
Page 230
Section 5 DLP-6
Total Access 850 System Manual
Perform the steps below in the order listed.
1. Connect to the Total Access 850 using either the 10BASET, rear CRAFT, or RCU faceplate CRAFT interfaces.
If you are not already connected to the unit’s RCU faceplate CRAFT or rear CRAFT interface (either with a VT100 compatible terminal or with a PC running VT100 emulation software), follow the procedure in DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port). Alternately, if the unit is part of a management cluster connected to the local network, you may use a PC connected to the network to Telnet into the unit. Use the procedures in DLP-3, Setting IP Parameters for the Total Access 850and DLP-5, Connecting to the Total Access 850 Using Telnet, to connect to the 10BASET interface. 2. Log in to the unit using the read-write password (see DLP-2, Logging in to the System, for more details).
Password security levels only apply to users connecting to the Total Access 850 system through Telnet access. All connections made through the CRAFT interface ALWAYS have maximum security rights. 3. Go to the SYSTEM CONFIG/MANAGEMENT/TELNET ACCESS menu, select the USER LIST menu, and press <Enter>. 4. Add a new user profile and password by selecting the first column (0) and pressing <I> (for insert). 5. Give the new user profile a name by selecting the NAME field, pressing <Enter>, and typing the user defined name. 6. Personalize the password for the appropriate level by selecting the PASSWORD field, pressing <Enter>, then typing the appropriate password. You will have to type the new password again to confirm it.
Passwords for the Total Access 850 system are case sensitive. There is no default password for a new user (i.e., you can configure a user as blank with no password). The current password displays as a series of asterisks (********). 7. Select the IDLE TIME field and press <Enter>. This field defines the amount of time in minutes the session may be idle before the user is logged off. The range is 1-255 and the default value is 10.
230
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 231
Total Access 850 System Manual
Section 5 DLP-6
8. Determine the password level for the corresponding label. The Total Access 850 contains seven different password levels. The following chart gives a brief description of each level. Select Level...
If you want the user to....
STATUS
Have read-only permission for all menu items - minimum rights
VOICE
Have read permission for all menu items and permission to use test commands
ROUTER
Have access to all commands except passwords, flash download, authentication methods, interface configurations, and Telnet security levels.
CONFIG
Have access to all commands except passwords, flash download, authentication methods, and Telnet security levels.
SUPPORT
Have access to all commands except passwords and Telnet security levels.
FULL
Have permission to edit every menu item, including creating and editing passwords -- maximum rights
ROUTER ONLY
Have read access to all menu items and write access to only the router menu.
9. Assign the password level to the appropriate label by selecting the LEVEL field and choosing the level decided upon in Step 8.
64203376L1-1B
© 2004 ADTRAN, Inc.
231
Page 232
Section 5 DLP-6
232
Total Access 850 System Manual
© 2004 ADTRAN, Inc.
64203376L1-1B