The text of a manual · part 23 of 30
Total Access 850 System Manual: Detail Level Procedures, pages 213 to 222
Pages 213 to 222 of 292, from Total Access 850 System Manual
The original document is the PDF (3.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Adtran 1200375L1
Page 213
DETAIL LEVEL PROCEDURES DLP-1
Connecting a VT100 Terminal or PC to the CRAFT Port. . . . . . . . . . . . . . . . . . . . . . . . . . . 215
DLP-2
Logging in to the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
DLP-3
Setting IP Parameters for the Total Access 850 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
DLP-4
Verifying Communications Over an IP LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
DLP-5
Connecting to the Total Access 850 Using Telnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
DLP-6
Adding/Removing Users and Changing Password Security Levels. . . . . . . . . . . . . . . . . . . 229
DLP-7
Updating the Firmware using TFTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
DLP-8
Updating the Firmware using XMODEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
DLP-9
Saving the Current Configuration Using TFTP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
DLP-10
Loading a Configuration Using TFTP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
DLP-11
Saving and Transferring a Current Configuration Using XMODEM . . . . . . . . . . . . . . . . . . . 245
DLP-12
Loading a Configuration Using XMODEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
DLP-13
Saving and Loading Text Configuration using Terminal Command Line . . . . . . . . . . . . . . . 249
DLP-14
A.03 to A.04 Firmware Upgrade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
DLP-15
Using the ADTRAN Utility Syslog. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
DLP-16
Connecting the Alarm Contacts and the External Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
DLP-17
Configuring the Total Access 850 for Dual T1 Maps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
64203376L1-1B
© 2004 ADTRAN, Inc.
213
Page 214
Section 5 Detail Level Procedures
214
Total Access 850 System Manual
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 215
DLP-1 Connecting a VT100 Terminal or PC to the CRAFT Port Introduction Total Access 850 shelf management and provisioning are facilitated by a series of intuitive menus that are accessible on a computer screen. Connecting either a VT100 terminal or a PC emulating a VT100 terminal to the RJ-45 CRAFT port on the rear of the unit or the DB-9 CRAFT interface on the RCU faceplate allows access to the menus and management features of Total Access 850. This section specifies how to connect the VT100 terminal or PC to the Total Access 850. The front CRAFT interface for the Total Access 850 is located on the faceplate of the RCU and is a DB-9 connector. Access can also be made to the Total Access 850 from the back of the unit through the RJ-45 interface labeled CRAFT, located on the back of the unit. A special ADTRAN adapter is required for access to this rear port.
Prerequisite Procedures The Total Access 850 must be powered for terminal communication to function.
Tools and Materials Required • • • •
VT100 compatible terminal or computer with terminal emulation software. A VT100 emulation program is provided with your shipment as part of the ADTRAN Utilities software suite. Appropriate cable to connect terminal to the Total Access 850 (customer-provided) DB-9 male to DB-9 female serviceable (customer-provided) for connecting to the RCU faceplate CRAFT port DB-9 female to RJ-45 female adapter (ADTRAN proprietary) for connecting to the CRAFT port on the rear of the unit. To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.
Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.
64203376L1-1B
© 2004 ADTRAN, Inc.
215
Page 216
Section 5 DLP-1
Total Access 850 System Manual
Perform the steps below in the order listed.
1. Connecting a VT100 terminal to Total Access 850: •
Set the parameters of the VT100 terminal or PC to: – 9600 baud rate – 8 data bits – No parity – 1 stop bit – No flow control
•
If the terminal has a parallel setting, disable it and use the serial port.
Using the RCU CRAFT Port
•
Plug the DB-9 male end of the data cable into the Total Access 850 CRAFT port on the front of the RCU. Make the connection to the VT100 terminal as appropriate for your equipment.
Using the rear CRAFT Port
•
Plug the RJ-45 end of the data cable into the Total Access 850 CRAFT port on the back of the unit. Make the connection to the VT100 terminal as appropriate for your equipment.
2. Connect a PC emulating a VT-100 terminal to Total Access 850.
Most personal computers (PCs) or laptops can run communications software that emulates a VT100 terminal. Examples include Windows programs such as Terminal® or Hyperterminal®. However, there are many other adequate, commercially available software packages which will allow your PC or laptop to emulate a VT100 terminal. •
Set the parameters of the communications software to: – 9600 baud rate – 8 data bits – No parity – 1 stop bit – No flow control
•
Set the PC for direct connect on the appropriate com port (instead of dial up connection).
Using the RCU CRAFT Port
•
Plug the DB-9 male end of the data cable into the Total Access 850 CRAFT port on the front of the unit. Make connection to the PC or laptop as appropriate for your equipment.
Using the rear CRAFT Port
•
Plug the RJ-45 end of the data cable into the Total Access 850 CRAFT port on the back of the unit. Make connection to the PC or laptop as appropriate for your equipment.
You are now ready to log in to the Total Access 850, as described in DLP-2, Logging in to the System.
216
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 217
DLP-2 Logging in to the System Introduction Once connected to the Total Access 850, you must login to the system to gain access to the management and provisioning functions. This DLP assumes you are connected to the Total Access 850 and provides specific steps for logging into the system.
Prerequisite Procedures Complete DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port.
To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.
Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.
After the IP parameters have been provisioned (see DLP-3, Setting IP Parameters for the Total Access 850), you can also log in via Telnet.
64203376L1-1B
© 2004 ADTRAN, Inc.
217
Page 218
Section 5 DLP-2
Total Access 850 System Manual
Perform the steps below in the order listed. 1. After connecting to the system, press any key to display the Login screen shown here. The blinking cursor at the Login field indicates that a password must be entered.
2. Enter the password for the Total Access 850 at the Login field. There is no manufacturer’s default password; press <Enter> to enter the Total Access 850 menus. 3. Upon entering the correct password, the Total Access 850 main menu is displayed as shown below.
4. You are now logged in to the Total Access 850 menu system.
218
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 219
DLP-3 Setting IP Parameters for the Total Access 850 Introduction The Total Access 850 comes pre-programmed for default Telnet access. The following IP parameters apply: • IP Address: 10.0.0.1 • Subnet Mask: 255.255.255.0 • User: guest • Password: password For security purposes, change the default Telnet password during the initial unit configuration. (Refer to System Config > Management > Telnet Access > User List on page 77 for more details.) If the Total Access 850 is connected to an IP network for Telnet, TFTP, or SNMP management, there are several IP parameters which must be set for the unit to communicate with the network. These parameters are described in this DLP along with the procedures for setting them. Please see your Network Administrator for the proper assignment of the following parameters: IP ADDRESS, SUBNET MASK, and DEFAULT GATEWAY.
Prerequisite Procedures This procedure assumes that the Total Access 850 unit is connected to an IP network and is powered up.
Tools and Materials Required • • • •
VT100 compatible terminal or computer with terminal emulation software Appropriate cable to connect terminal to the Total Access 850 (customer-provided) DB-9 male to DB-9 female adapter (customer-provided) for connecting to the RCU faceplate CRAFT port DB-9 female to RJ-45 female adapter (ADTRAN proprietary) for connecting to the CRAFT port on the rear of the unit
To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.
Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.
64203376L1-1B
© 2004 ADTRAN, Inc.
219
Page 220
Section 5 DLP-3
Total Access 850 System Manual
Perform the steps below in the order listed.
1. Connect the Total Access 850 unit to your VT100 system (details found in DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port). 2. Log in to the system. 3. From the ROUTER/CONFIG menu, select the INTERFACES option and press <Enter>. 4. Select SETUP for the ETH interface, then PRIMARY IP. 5. Highlight the IP ADDRESS field and press <Enter>. Enter the appropriate IP address (as given by your system administrator). 6. Highlight the SUBNET MASK field and press <Enter>. Enter the appropriate subnet mask (as given by your system administrator). 7. Highlight the DEFAULT GATEWAY field and press <Enter>. Enter the appropriate default gateway (as given by your system administrator). 8. Press the left arrow key to highlight the PRIMARY IP submenu. This action saves your changes and requires confirmation. 9. Escape out to the ROUTER menu and log off by pressing <CTRL+L>.
220
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 221
DLP-4 Verifying Communications Over an IP LAN Introduction When the Ethernet port is connected to a local area network (LAN), test steps must be performed on the Total Access 850 to ensure that the unit is communicating properly over the network. This procedure outlines those steps.
Prerequisite Procedures Before beginning this procedure, the unit should be physically connected to the LAN and the provisioning tasks detailed in DLP-3, Setting IP Parameters for the Total Access 850, should be complete.
Tools and Materials Required •
Access to a PC or other computer connected to the LAN
To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.
Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.
64203376L1-1B
© 2004 ADTRAN, Inc.
221
Page 222
Section 5 DLP-4
Total Access 850 System Manual
Perform the steps below in the order listed.
1. Verify the Total Access 850 IP address.
If you do not already have the IP Address for the Total Access 850, obtain it from the network administrator or manually check for the address in the ROUTER CONFIG/INTERFACE/SETUP/PRIMARY IP/IP ADDRESS menu of the Network Management interface.
You must log in with a security level of 2 to modify the IP parameters on the Total Access 850. (See DLP-2, Logging in to the System for more details.)
2. Ping the Total Access 850 unit from a remote computer on the network.
Using a remote computer system connected to the LAN, perform an ICMP Ping on the IP Address of the Total Access 850. Verify that the unit responds properly. If the Total Access 850 fails to respond, try the following: • Verify that the proper IP Address, Subnet Mask, and Default Gateway are provisioned in the unit (see DLP-2, Logging in to the System, for details). • Verify that the Total Access 850 is properly cabled into the LAN and that the Ethernet cable is properly seated in the RJ-45 LAN jack on the rear of the unit. • Verify the link light on the RCU is lit. If not lit, check the cabling between the hub and the shelf. • If the Total Access 850 is connected to a hub or other network device that provides a carrier sense light for each port, verify that the carrier sense light for the port to which the Total Access 850 is connected is lit. If this light is not lit, check the cabling between the hub and the shelf. • Verify the IP Address, Subnet Mask, and Default Gateway on the remote computer system. • Use Ethernet straight-through cable for connection to hub or switch. Use Ethernet crossover if connecting to PC. If none of these steps are successful, contact the LAN Administrator for assistance. Refer to the documentation of the computer system if you are unsure how to perform a Ping command. Most computers running a networked version of Microsoft Windows™ or UNIX allow a Ping to be performed by simply typing ping <IP Address> at a command line prompt. Typically, the Ping program will respond by indicating that the remote IP Address has responded in a certain amount of time or that no response was received.
Some versions of Ping will continue running until you explicitly tell them to stop. If the program does not terminate on its own, press <CTRL+C> to get the program to stop.
3. Telnet to the Total Access 850.
222
© 2004 ADTRAN, Inc.
64203376L1-1B