Page 205

Total Access 850 System Manual

Section 4 User Interface Guide

T1 Interface Setup Instructions Step

Action

1

From the main menu, select INTERFACES.

2

Highlight the CONFIG menu for the T1 interface and press <ENTER>.

3

Right arrow to select FORMAT and choose ESF or SF.

This format must match the format used by the other units in the network.

4

Set the LINE CODE to B8ZS or AMI.

This line code must match the line code used by the other units in the network.

5

Set the EQUALIZATION or line build out. The default setting of 0 DB is usually sufficient.

6

Set the CSU LPBK option to ENABLE, DISABLE, or DISABLE ALL based on whether looping to this unit from another unit will be allowed.

Ethernet Interface Setup Instructions Most applications should not require a manual setup for the Ethernet interface. By default, the Ethernet interface is configured to auto-detect the data rate (as either 10 or 100 Mbps). The following steps disable the auto-negotiation parameter and manually configure the interface. Step

64203376L1-1B

Action

1

From the main menu, select INTERFACES.

2

Highlight the CONFIG menu for the ETH interface and press <ENTER>.

3

Use the right arrow to select AUTONEGOTIATION and press <ENTER>. Use the down arrow to choose OFF.

4

Select the DATA RATE field and specify either 10BASET or 100BASET.

5

Select the DUPLEX TYPE field and specify either HALF DUPLEX or FULL DUPLEX.

© 2004 ADTRAN, Inc.

205

Page 206

Section 4 User Interface Guide

Total Access 850 System Manual

.2. Configuring the Layer 2 Protocol

For more details on the configuration parameters discussed in this section, refer to the following pages: Layer 2 ATM Network Interface Protocol menus beginning on page 129 Layer 2 Protocol (ATM) Configuration – T1 Interface Step

206

Action

1

From the main menu, select L2 PROTOCOL and press <ENTER>.

2

Use the arrow keys to select the PROTOCOL field for the T1 interface. Press <ENTER>. Select ATM from the list of available protocols.

3

Use the arrow keys to select the CONFIG menu for the T1 interface and press <ENTER>.

4

Highlight the ATM CONFIG menu for the T1 interface and press <ENTER>.

5

Enter the IDLE CELLS format for your network.

6

Set DATA SCRAMBLING appropriately for your network.

7

Back all the way out to one level to the PVC CONFIG menu, and press <ENTER>. Enter the VPI and VCI values for communicating with that Gateway. Select ROUTER under the CONNECTION field.

8

Select the SETUP menu and configure the virtual circuit for IP or PPP operation. (Our example selects IP.) Refer to L2 Protocol (T1 ATM–T1–ATM) > Config > PVC Config > Connection on page 131 for more details.

9

Set mode to ROUTE IP. Using this menu you also have the option to route only IP packets and bridge all other data packets (ROUTE IP/BRIDGE OTHER) or bridge all data packets on this connection (BRIDGE ALL). Refer to L2 Protocol (T1 ATM–T1–ATM) > Config > PVC Config > Setup (Router) on page 131 for more details.

10

Left arrow back to the main menu to save the changes.

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 207

Total Access 850 System Manual

Section 4 User Interface Guide

3. Setting the Router Options For more details on the configuration parameters discussed in this section, refer to the following pages: Router Ethernet Interface Configuration menus beginning on page 148 Router Network Interface Configuration menus beginning on page 148 Router Default Gateway menus beginning on page 157 Router Options – Ethernet Interface Step

Action

1

From the main menu, select ROUTER and press <ENTER>.

2

Use the right arrow key to highlight CONFIG and press <ENTER>.

3

Select INTERFACES and press <ENTER>. Use the right arrow key to highlight the SETUP field for the ETH (Ethernet) interface and press <ENTER>.

4

Highlight the PRIMARY IP field and press <ENTER>.

5

Set the IP ADDRESS of the Ethernet port.

6

Set the SUBNET MASK for the Ethernet port.

7

By default, RIP is disabled on the Ethernet interface. If RIP needs to be enabled, highlight the RIP field and press <ENTER>. Set the appropriate VERSION, RIP METHOD, DIRECTION, and V2 SECRET (where applicable) to configure RIP on the interface. For more details, refer to Router > Config > Interfaces (ETH) > Sub-Interface on page 148.

8

Press the left arrow key to return to the Ethernet sub-interface menu (displays PRIMARY IP and SECONDARY IP).

9

If your application requires additional secondary IP address, highlight the SECONDARY IP field and press <ENTER>. The Total Access 850 supports up to 5 additional LAN segments. Enter each additional secondary IP address and corresponding subnet mask. To add a new IP address entry, highlight the NUM field and press the <I> key. To delete an existing entry, highlight the NUM field for the entry to delete and press the <D> key.

10

Left arrow back to the main menu to save the changes.

Router Options – T1 Interface (L2 Protocol = ATM) Step

Action

1

From the main menu, select ROUTER and press <ENTER>.

2

Use the right arrow key to highlight CONFIG and press <ENTER>.

64203376L1-1B

© 2004 ADTRAN, Inc.

207

Page 208

Section 4 User Interface Guide

Total Access 850 System Manual

Router Options – T1 Interface (L2 Protocol = ATM) (Continued)

3

Select INTERFACES and press <ENTER>. Use the right arrow key to highlight the SETUP field for the T1 interface and press <ENTER>. Each virtual circuit on the T1 interface defined in the PVC CONFIG has a separate listing in the ROUTER INTERFACES table.

4

Set ACTIVE to YES to activate the virtual circuit.

5

Enter the appropriate VPI and VCI values.

6

Select the desired ADDRESS MODE. Refer to Address Mode on page 151 for more details.

7

Enter the Total Access 850 LOCAL IP ADDRESS and corresponding IP NETMASK for the selected virtual circuit.

8

Enter the IP address for the next hop router in the FAR-END IP ADDRESS field.

9

For NAT configuration, refer to Appendix C. RFC1483 Quick Start (IP Routing with NAT) on page 209.

10

Left arrow back to the main menu to save the changes.

Router Options – Setting the Default Gateway Step

208

Action

1

From the main menu, select ROUTER and press <ENTER>.

2

Use the right arrow key to highlight CONFIG and press <ENTER>.

3

Select ROUTES and press <ENTER>. Set the DEFAULT GATEWAY field to the appropriate IP address.

4

Left arrow back to the main menu to save the changes.

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 209

Total Access 850 System Manual

Section 4 User Interface Guide

Appendix C. RFC1483 Quick Start (IP Routing with NAT) To illustrate the use of NAT, consider the example from Appendix B. RFC1483 Quick Start (IP Routing) on page 204. To add NAT to the IP routing example, use the NAT menus. For more details on the configuration parameters discussed in this section, refer to the following pages: Router Network Interface Configuration menus beginning on page 148 IP Routing with NAT Step 1

Action The NAT menu is found under ROUTER >CONFIGURATION > INTERFACES > SETUP > NAT. The NAT menu can easily be accessed by pressing <CTRL+N>.

The network interface will not appear if a virtual circuit is not defined using the L2 PROTOCOL menus. 2

From the NAT menu, set PORT TRANSLATION to ENABLED. (This will enable translation and populate the corresponding NAT menu options.) Set PUBLIC IP ADDRESS MODE to either INTERFACE or SPECIFIED. •

INTERFACE (default) configures NAT to use the IP address already assigned to the interface. (In other words, the interface address and the NAPT address are the same.)

•

SPECIFIED allows you to define a different IP address for the NAPT address (public address for private addresses to be translated into).

3

For basic NAT, this is all of the configuration that needs to be done. For specific port translations or 1:1 mapping, you can enter TRANSLATION TABLE.

4

From the TRANSLATION TABLE menu, create a new entry by using the right arrow to enter the table. Additional entries can be created by highlighting the first entry index number and pressing the <I> key. Entries can be deleted by highlighting the selected entry index number and pressing the <D> key. Create specific NAT translations based on your application. PUBLIC IP ADDRESS MODE Use the configured interface IP address as the NAPT address or use SPECIFIED to set a different public address to be used for the translation.

PROTOCOL MODE 5

Protocol for this translation. (TCP, UCP, ICMP, TCP or UDP, TCP UDP or ICMP, All, Specified, and NONE.)

PRIVATE ADDRESS MODE SPECIFIED or ANY INTERNAL. Choosing SPECIFIED brings up the PRIVATE ADDRESS option. TRANSLATE BODY

YES or NO. If set to YES, this will translate the body of the data packet and replace the private address with the NAPT address. Default is NO, which is used for most applications.

64203376L1-1B

© 2004 ADTRAN, Inc.

209

Page 210

Section 4 User Interface Guide

Total Access 850 System Manual

Appendix D. RFC 1483 Quick Start (Bridging) Initial Setup It is best to configure Total Access 850 ATM applications by following the order of the top-level menus. For example, first configure the system parameters using the SYSTEM INFO and SYSTEM CONFIG menus. Next, configure the Layer 1 parameters using the INTERFACES menu. Once the Layer 1 information is configured, proceed to the Layer 2 setup using the L2 PROTOCOL menus. Follow the Layer 2 setup with the data “routing” menus (either BRIDGE or ROUTER). Finally, establish packet forwarding and blocking using the SECURITY menus. The following example provides step by step instructions for configuring the Total Access 850 T1 ATM system (INTERFACES and L2 PROTOCOL) for a standard bridging application. System Info and System Config parameters should be set according to your system need. Refer to System Info on page 73 and System Config on page 75 for more details.

1. Setting up the Interfaces For more details on the configuration parameters discussed in this section, refer to the following pages: Network T1 menus beginning on page 94 Ethernet menus beginning on page 101 T1 Interface Setup Instructions Step

Action

1

From the main menu, select INTERFACES.

2

Highlight the CONFIG menu for the T1 interface and press <ENTER>.

3

Right arrow to select FORMAT and choose ESF or SF.

This format must match the format used by the other units in the network.

4

Set the LINE CODE to B8ZS or AMI.

This line code must match the line code used by the other units in the network.

210

5

Set the EQUALIZATION or line build out. The default setting of 0 DB is usually sufficient.

6

Set the CSU LPBK option to ENABLE, DISABLE, or DISABLE ALL based on whether looping to this unit from another unit will be allowed.

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 211

Total Access 850 System Manual

Section 4 User Interface Guide

Ethernet Interface Setup Instructions Most applications should not require a manual setup for the Ethernet interface. By default, the Ethernet interface is configured to auto-detect the data rate (as either 10 or 100 Mbps). The following steps disable the auto-negotiation parameter and manually configure the interface. Step

Action

1

From the main menu, select INTERFACES.

2

Highlight the CONFIG menu for the ETH interface and press <ENTER>.

3

Use the right arrow to select AUTONEGOTIATION and press <ENTER>. Use the down arrow to choose OFF.

4

Select the DATA RATE field and specify either 10BASET or 100BASET.

5

Select the DUPLEX TYPE field and specify either HALF DUPLEX or FULL DUPLEX.

.2. Configuring the Layer 2 Protocol

For more details on the configuration parameters discussed in this section, refer to the following pages: Layer 2 ATM Network Interface Protocol menus beginning on page 129 Layer 2 Protocol (ATM) Configuration – T1 Interface Step

Action

1

From the main menu, select L2 PROTOCOL and press <ENTER>.

2

Use the arrow keys to select the PROTOCOL field for the T1 interface. Press <ENTER>. Select ATM from the list of available protocols.

3

Use the arrow keys to select the CONFIG menu for the T1 interface and press <ENTER>.

4

Highlight the ATM CONFIG menu for the T1 interface and press <ENTER>.

5

Enter the IDLE CELLS format for your network.

6

Set DATA SCRAMBLING appropriately for your network.

7

Back all the way out to one level to the PVC CONFIG menu, and press <ENTER>. Enter the VPI and VCI values for communicating with that Gateway. Select ROUTER under the CONNECTION field.

8

Select the SETUP menu and configure the virtual circuit for IP or PPP operation. (Our example selects IP.) Refer to L2 Protocol (T1 ATM–T1–ATM) > Config > PVC Config > Setup (Router) on page 131 for more details.

64203376L1-1B

© 2004 ADTRAN, Inc.

211

Page 212

Section 4 User Interface Guide

Total Access 850 System Manual

Layer 2 Protocol (ATM) Configuration – T1 Interface (Continued)

9

Set mode to ROUTE IP. Using this menu you also have the option to route only IP packets and bridge all other data packets (ROUTE IP/BRIDGE OTHER) or bridge all data packets on this connection (BRIDGE ALL). Refer to L2 Protocol (T1 ATM–T1–ATM) > Config > PVC Config > Setup (V35) on page 133 for more details.

10

Left arrow back to the main menu to save the changes.

3. Verifying the Bridge Options For more details on the configuration parameters discussed in this section, refer to the following pages: Bridge menus beginning on page 145 Bridge Options Step

212

Action

1

From the main menu, select BRIDGE and press <ENTER>.

2

Use the right arrow key to highlight CONFIG and press <ENTER>.

3

Select INTERFACES and press <ENTER>. Verify that the desired interface is listed in this table.

4

Left arrow back to the BRIDGE > CONFIG menu.

5

Select BRIDGE TABLE and set the BRIDGE TABLE AGING to the desired time (in minutes) it takes an entry to age out of the Bridge table.

6

Left arrow back to the main menu to save the changes.