Page 195
Total Access 850 System Manual
Section 4 User Interface Guide
FXS Interface Setup Instructions (Continued) 11
Press <ENTER> on the TANDEM [+] option to view the TANDEM options if the port mode is set to TANDEM (E&M).
12
Set the CONVERSION MODE of the port to either LOOP START or GROUND START.
13
Set the SUPERVISION of the port to either IMMEDIATE or WINK.
Be sure to set the TANDEM options for each port set to TANDEM E&M.
2. Mapping the DS0s For more details on the configuration parameters discussed in this section, refer to the following pages: DS0 Map menus beginning on page 180 DS0 Mapping Instructions Step 1
Action From the main menu, select DS0 MAPS. Verify that the ACTIVE MAP is set to either MAP 1 or MAP 2. This is the map that is actively running on the unit. The unit has the ability to store two maps.
2
•
To edit the current map, press <ENTER> on EDIT/VIEW MAP 1 to view the map. (If Map 1 is the Active Map)
•
To edit the standby map, press <ENTER> on EDIT/VIEW MAP 2 to view the map. (If Map 2 is the Active Map)
The DS0 listed on the left side of the menu corresponds to DS0s (1 through 24) on the network T1 interface. 3
Scroll down to the DS0 that will be mapped.
4
Set the SERVICE for the DS0 that you are mapping to FXS.
5
Set the PORT of the DS0 that you are mapping. The port number entered must match the voice port the DS0 is being mapped to. RBS (robbed bit signaling) will automatically turn on when a port number has been selected.
6
Map all the DS0s as desired, and exit this menu by pressing the left arrow button. Your changes will automatically save when exiting the map.
7
Make sure the ACTIVE MAP is set to the correct map (the map you want running) before exiting the DS0 MAPS menu.
8
Left arrow back to the main menu.
64203376L1-1B
© 2004 ADTRAN, Inc.
195
Page 196
Section 4 User Interface Guide
Total Access 850 System Manual
Appendix D. Configuring the Unit for DSX-1 Applications The Total Access 600 Series systems are available with an integrated DSX-1 interface for both voice and data applications. Regardless of the application (either voice or data), the Total Access 850 has the ability to map DS0s from the network T1 to DS0s on the DSX-1 interface (cross-connect) without affecting the data present on the DS0s. This feature allows the Total Access 850 to support voice with dedicated signaling channels (ISDN), voice with in-channel signaling information (Robbed Bit Signaling (RBS) to a PBX, key system, etc.), as well as clear channel data to an external T1 router.
Initial Setup It is best to configure Total Access 850 TDM applications by following the order of the top-level menus. For example, first configure the system parameters using the SYSTEM INFO and SYSTEM CONFIG menus. Next, configure the Layer 1 parameters using the INTERFACES menu. Once the Layer 1 information is configured, proceed to the Layer 2 setup using the L2 PROTOCOL menus. Follow the Layer 2 setup with the data “routing” menus (either BRIDGE or ROUTER). Establish packet forwarding and blocking using the SECURITY menus. Lastly, configure the physical mappings using the DS0 MAPS menus. The following example provides details for configuring the Total Access 850 to pass analog voice over the DSX-1 interface (using RBS), digital voice (fractional PRI with D-Channel), and data bandwidth. The Total Access 850 provides a single DSX-1 interface, so it is unlikely that your application will require all three features on the DSX-1 interface simultaneously; therefore ignore any steps that do not pertain to your application. Perform the following steps in order to configure the applications (INTERFACES through DS0 MAPS). SYSTEM INFO and SYSTEM CONFIG parameters should be set according to your system need. Refer to System Info on page 73 and System Config on page 75 for more details.
1. Setting up the Interfaces For more details on the configuration parameters discussed in this section, refer to the following pages: Network T1 menus beginning on page 94 DSX-1 menus beginning on page 109 T1 Interface Setup Instructions Step
Action
1
From the main menu, select INTERFACES.
2
Highlight the CONFIG menu for the T1 interface and press <ENTER>.
3
Right arrow to select FORMAT and choose ESF or SF.
This format must match the format used by the other units in the network.
4
196
Set the LINE CODE to B8ZS or AMI.
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 197
Total Access 850 System Manual
Section 4 User Interface Guide
T1 Interface Setup Instructions (Continued)
This line code must match the line code used by the other units in the network.
5
Set the EQUALIZATION or line build out. The default setting of 0 DB is usually sufficient.
6
Set the CSU LPBK option to ENABLE, DISABLE, or DISABLE ALL based on whether looping to this unit from another unit will be allowed.
DSX-1 Interface Setup Instructions Step
Action
1
From the main menu, select INTERFACES.
2
Highlight the CONFIG menu for the DSX interface and press <ENTER>.
3
Right arrow to select FORMAT and choose ESF or SF.
This FORMAT must match the format used by the equipment connected to the DSX-1 interface. A FORMAT mismatch normally results in a Red Alarm condition. 4
Set the LINE CODE to B8ZS or AMI.
This line code must match the line code used by the equipment connected to the DSX-1 interface. 5
Set the EQUALIZATION or line build out. The default setting of 0 DB is usually sufficient.
6
Set the CSU LPBK option to ENABLE, DISABLE, or DISABLE ALL based on whether looping to this unit from another unit will be allowed.
2. Mapping the DS0s For more details on the configuration parameters discussed in this section, refer to the following pages: DS0 Map menus beginning on page 180
64203376L1-1B
© 2004 ADTRAN, Inc.
197
Page 198
Section 4 User Interface Guide
Total Access 850 System Manual
DS0 Mapping Instructions Step 1
Action From the main menu, select DS0 MAPS. Verify that the ACTIVE MAP is set to either MAP 1 or MAP 2. This is the map that is actively running on the unit. The unit has the ability to store two maps.
2
•
To edit the current map, press <ENTER> on EDIT/VIEW MAP 1 to view the map. (If Map 1 is the Active Map)
•
To edit the standby map, press <ENTER> on EDIT/VIEW MAP 2 to view the map. (If Map 2 is the Active Map)
The DS0 listed on the left side of the menu corresponds to DS0s on the network T1 interface. The PORT number identifies the DS0 on the DSX-1 interface. The DS0 and PORT do not need to match; DS0s can be cross-connected from the network T1 to any DS0 on the DSX-1 interface.
198
3
Scroll down to the DS0 that will be mapped. (Any DS0 can be mapped to the DSX-1 interface.)
4
Set the SERVICE for the DS0 that you are mapping to DSX-1.
5
Set the PORT of the DS0 that you are mapping. The port number entered specifies the DS0 on the DSX-1 interface and can be set to any available DS0. When mapping voice circuits with dedicated signaling channels, be sure to map the signaling channel to the proper DS0 on the DSX-1 interface. For example, ISDN D channel signaling is normally carried on DS0 24. Unless the equipment connected to the Total Access 850 DSX-1 interface has been specifically programmed, it will expect a D channel on DS0 24. Map DS0 24 to Port 24 to provide the D channel in the appropriate timeslot.
6
Set RBS to OFF or ON depending on the application. When passing voice circuits with in-channel signaling through to the DSX-1 interface, signaling bits are preserved by setting RBS to ON. For clear channel service to the DSX-1 interface (for voice circuits with a dedicated signaling channel and all data) set RBS to OFF (which ignores the signaling bits).
7
Map all the DS0s as desired, and exit this menu by pressing the left arrow button. Your changes will automatically save when exiting the map.
8
Make sure the ACTIVE MAP is set to the correct map (the map you want running) before exiting the DS0 MAPS menu.
9
Left arrow back to the main menu.
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 199
Total Access 850 System Manual
5.
Section 4 User Interface Guide
APPENDICES (T1 ATM APPLICATIONS) The following example is for configuring T1 units with ATM firmware. However, all units using ATM firmware (SDSL, ADSL, SHDSL) may be configured in the same manner. To configure ATM Voice applications with other network types, disregard the T1 Interface Setup Instructions and configure your network interface as needed.
Appendix A. Voice Gateway Quick Start Procedure (Voice Turn Up) A typical VoATM application (see Figure 7) uses a Total Access 850 connected to an ATM network. For voice applications, a Voice Gateway is needed to interface with the PSTN. Jetstream, Tollbridge, CopperCom, and LES-CAS are popular Gateway types.
Figure 7. Application Diagram
To configure a Total Access 850 for use with the Voice Gateway, you need to know the VPI and VCI used on the ATM network to access the Gateway from this Total Access 850. You also need to know the format for IDLE CELLS and whether DATA SCRAMBLING is used on this ATM network. The following procedure will help you navigate the Total Access 850 menus for configuring the necessary elements for VoATM with the Voice Gateway. Perform the following steps in order to configure the application.
Initial Setup It is best to configure Total Access 850 ATM applications by following the order of the top-level menus. For example, first configure the system parameters using the SYSTEM INFO and SYSTEM CONFIG menus. Next, configure the Layer 1 parameters using the INTERFACES menu. Once the Layer 1 information is configured, proceed to the Layer 2 setup using the L2 PROTOCOL menus.
64203376L1-1B
© 2004 ADTRAN, Inc.
199
Page 200
Section 4 User Interface Guide
Total Access 850 System Manual
The following example provides step by step instructions for configuring the Total Access 850 T1 ATM system (INTERFACES and L2 PROTOCOL) for a standard voice application. System Info and System Config parameters should be set according to your system need. Refer to System Info on page 73 and System Config on page 75 for more details.
1. Setting up the Interfaces For more details on the configuration parameters discussed in this section, refer to the following pages: Network T1 menus beginning on page 94 FXS menus beginning on page 103 T1 Interface Setup Instructions Step
Action
1
From the main menu, select INTERFACES.
2
Highlight the CONFIG menu for the T1 interface and press <ENTER>.
3
Right arrow to select FORMAT and choose ESF or SF.
This format must match the format used by the other units in the network. 4
Set the LINE CODE to B8ZS or AMI.
This line code must match the line code used by the other units in the network.
200
5
Set the EQUALIZATION or line build out. The default setting of 0 DB is usually sufficient.
6
Set the CSU LPBK option to ENABLE, DISABLE, or DISABLE ALL based on whether looping to this unit from another unit will be allowed.
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 201
Total Access 850 System Manual
Section 4 User Interface Guide
FXS Interface Setup Instructions Step
Action
1
From the main menu, select INTERFACES.
2
Highlight the CONFIG menu for the FXS interface and press <ENTER>.
3
Right arrow to select MODE and choose LOOP START, GROUND START, TANDEM (E&M), TR08 SINGLE, TR08 UVG, or DPO.
This mode should be set based on the network configuration and the operation of each FXS port. All FXS ports are independent and do not need to have the same mode.
64203376L1-1B
4
Set the TX (dB) or transmit direction level for each port. The default value is recommended.
5
Set the RX (dB) or received direction level for each port. The default value is recommended.
6
Set the SVC MODE to IN SERVICE to activate the port.
7
Set the LINE Z (line impedance) of each port based on the size of the network. The default value is recommended.
8
Set the MSG IND to DISABLE or ENABLE. When set to ENABLE, talk path is always open, even in on-hook conditions, in order for FXS message tones to pass through. Disabling this feature will allow higher on-hook voltage but will not allow on-hook messaging other than caller ID.
9
Configure the on-hook battery voltage using the BATT MODE field. For most IAD installs, the FXS loop is short with 6 to 7 V present on tip / ring. To reduce power dissipated during off-hook conditions, the battery is lowered for short loop lengths. When set to AUTO SWITCH, the IAD uses a higher on-hook battery voltage (48-52 V). When off-hook, it automatically switches to low battery (24-26 V) to minimize power dissipation. When set to LOW BATTERY mode, the higher battery is not used and the voltage is a constant 26 V even while on-hook. The tip/ring voltage is reduced to 26 V when using the LOW BATTERY mode.
10
Specify the interval of battery removal during a forward disconnect state using the FWD DISC TIMER field. Choices are FOLLOW SWITCH (default), 500MS, 750MS, 1000MS, and 2000MS. When using ATM mode, there is an additional choice of IGNORE SWITCH. If the timer is set to FOLLOW SWITCH, the Total Access 850 will follow the switch at all times; this is normal operation. If a time period has been selected, the Total Access 850 will remove battery for the specified time period OR as long as the switch requests battery removal, whichever is longer. For example, if the timer expires but the switch continues to request battery removal, the Total Access 850 will follow the switch and continue to remove battery. For ATM mode, if the timer is set to IGNORE SWITCH, the IAD will never remove battery.
© 2004 ADTRAN, Inc.
201
Page 202
Section 4 User Interface Guide
Total Access 850 System Manual
FXS Interface Setup Instructions (Continued) 11
Press <ENTER> on the TANDEM [+] option to view the TANDEM options if the port mode is set to TANDEM (E&M).
12
Set the CONVERSION MODE of the port to either LOOP START or GROUND START.
13
Set the SUPERVISION of the port to either IMMEDIATE or WINK.
Be sure to set the TANDEM options for each port set to TANDEM E&M.
2. Configuring the Layer 2 Protocol For more details on the configuration parameters discussed in this section, refer to the following pages: Layer 2 ATM Network T1 menus beginning on page 129 Layer 2 Protocol Configuration – T1 Interface Step
202
Action
1
From the main menu, select L2 PROTOCOL and press <ENTER>.
2
Use the arrow keys to select the PROTOCOL field for the T1 interface. Press <ENTER>. Select ATM from the list of available protocols.
3
Use the arrow keys to select the CONFIG menu for the T1 interface and press <ENTER>.
4
Highlight the ATM CONFIG menu for the T1 interface and press <ENTER>.
5
Enter the IDLE CELLS format for your network.
6
Set DATA SCRAMBLING appropriately for your network.
7
Back all the way out to one level to the PVC CONFIG menu, and press <ENTER>. Enter the VPI and VCI values for communicating with that Gateway. (From this menu, the appropriate Voice information for working with the Voice Gateway is entered by selecting VOICE under the CONNECTION field.)
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 203
Total Access 850 System Manual
Section 4 User Interface Guide
Layer 2 Protocol Configuration – T1 Interface (Continued)
8
Select SETUP, and from the SETUP menu, enter the Gateway type under CALL CONTROL and enter the VPI and VCI values for communicating with that Gateway. For this application, CALL CONTROL and virtual identifier (VPI and VCI) values should be set appropriately for your network.
9
To verify correct setup, use the PVC STATUS menu (under the STATUS menu located at L2 PROTOCOL [0] > STATUS) to look at the current status of the voice connection. Under STATUS, view information about the voice PVC along with information about the POTS ports available on the unit.
64203376L1-1B
© 2004 ADTRAN, Inc.
203
Page 204
Section 4 User Interface Guide
Total Access 850 System Manual
Appendix B. RFC1483 Quick Start (IP Routing) The Total Access 850 allows for complete integration of voice and data delivery from one compact platform (see Figure 10). Once you have completed the voice turn up procedure from the previous example, adding data to the circuit requires some additional setup.
USP
UCR
1L605711
V84-
N LA B K
1L673021
1 L 90 5 7 1
C zH02
XT
R
3
3
A
A M P
T
N E
F
A M P
T
XT XR M
OCA
N LA B K
SXF
1 L 90 5 7 1
SXF
1 L 8 0 4 5 7 1
1 L 8 0 4 5 7 1
SXF
SXF
1 L 8 0 4 5 7 1
1 L 8 0 4 5 7 1
SXF 1 L 8 0 4 5 7 1
YSU B 1
YSU B
YSU B 1
YSU B 1
YSU B
1
2
2
2
2
2
3
3
3
3
3
4
4
4
4
4
O N
XR
PWR
N A B K
N LA B K 1 L 90 5 7 1
1
T1ALRM
TSET 1T
RORE 1T
DT 53.V
DR 53.V
ILHTE
XR/XTHTE
Figure 10. Application Diagram
To configure a Total Access 850 for IP routing, you need to know the VPI and VCI values for the data circuit on your network. You also need the IP address of the next hop router in the circuit. Perform the following steps in order to configure the application.
Initial Setup It is best to configure Total Access 850 ATM applications by following the order of the top-level menus. For example, first configure the system parameters using the SYSTEM INFO and SYSTEM CONFIG menus. Next, configure the Layer 1 parameters using the INTERFACES menu. Once the Layer 1 information is configured, proceed to the Layer 2 setup using the L2 PROTOCOL menus. Follow the Layer 2 setup with the data “routing” menus (either BRIDGE or ROUTER). Finally, establish packet forwarding and blocking using the SECURITY menus. The following example provides step by step instructions for configuring the Total Access 850 T1 ATM system (INTERFACES and L2 PROTOCOL) for a standard routing application. System Info and System Config parameters should be set according to your system need. Refer to System Info on page 73 and System Config on page 75 for more details.
1. Setting up the Interfaces For more details on the configuration parameters discussed in this section, refer to the following pages: Network T1 menus beginning on page 94 Ethernet menus beginning on page 101
204
© 2004 ADTRAN, Inc.
64203376L1-1B