Page 185

Total Access 850 System Manual

Section 4 User Interface Guide

Layer 2 Protocol Configuration – Ethernet Interface

3

Set mode to ROUTE IP. Using this menu you also have the option to route only IP packets and bridge all other data packets (ROUTE IP/BRIDGE OTHER) or bridge all data packets on this connection (BRIDGE ALL). Refer to L2 Protocol (ALL–ETH–802.3) > Config > Mode on page 144 for more details.

4

Left arrow back to the main menu to save the changes.

3. Setting the Router Options For more details on the configuration parameters discussed in this section, refer to the following pages: Router Ethernet Interface Configuration menus beginning on page 148 Router Network Interface Configuration menus beginning on page 148 Router Default Gateway menus beginning on page 157 Router Options – Ethernet Interface Step

Action

1

From the main menu, select ROUTER and press <ENTER>.

2

Use the right arrow key to highlight CONFIG and press <ENTER>.

3

Select INTERFACES and press <ENTER>. Use the right arrow key to highlight the SETUP field for the ETH (Ethernet) interface and press <ENTER>.

4

Highlight the PRIMARY IP field and press <ENTER>.

5

Set the IP ADDRESS of the Ethernet port.

6

Set the SUBNET MASK for the Ethernet port.

7

By default, RIP is disabled on the Ethernet interface. If RIP needs to be enabled, highlight the RIP field and press <ENTER>. Set the appropriate VERSION, RIP METHOD, DIRECTION, and V2 SECRET (where applicable) to configure RIP on the interface. For more details, refer to Router > Config > Interfaces (ETH) > Sub-Interface on page 148.

8

Press the left arrow key to return to the Ethernet sub-interface menu (displays PRIMARY IP and SECONDARY IP).

9

If your application requires additional secondary IP address, highlight the SECONDARY IP field and press <ENTER>. The Total Access 850 supports up to 5 additional LAN segments. Enter each additional secondary IP address and corresponding subnet mask. To add a new IP address entry, highlight the NUM field and press the <I> key. To delete an existing entry, highlight the NUM field for the entry to delete and press the <D> key.

10

Left arrow back to the main menu to save the changes.

64203376L1-1B

© 2004 ADTRAN, Inc.

185

Page 186

Section 4 User Interface Guide

Total Access 850 System Manual

Router Options – T1 Interface (L2 Protocol = FRE or PPP) Step

Action

1

From the main menu, select ROUTER and press <ENTER>.

2

Use the right arrow key to highlight CONFIG and press <ENTER>.

3

Select INTERFACES and press <ENTER>. Use the right arrow key to highlight the SETUP field for the T1 interface and press <ENTER>. Each PVC (frame relay) on the T1 interface defined in the DLCI MAP has a separate listing in the ROUTER INTERFACES table.

4

Set ACTIVE to YES to activate the virtual circuit.

5

Select the desired ADDRESS MODE. Refer to Address Mode on page 151 for more details.

6

Enter the Total Access 850 LOCAL IP ADDRESS and corresponding IP NETMASK for the selected virtual circuit.

7

Enter the IP address for the next hop router in the FAR-END IP ADDRESS field.

8

For NAT configuration, refer to Appendix C. RFC1483 Quick Start (IP Routing with NAT) on page 209.

9

Left arrow back to the main menu to save the changes.

Router Options – Setting the Default Gateway Step

Action

1

From the main menu, select ROUTER and press <ENTER>.

2

Use the right arrow key to highlight CONFIG and press <ENTER>.

3

Select ROUTES and press <ENTER>. Set the DEFAULT GATEWAY field to the appropriate IP address.

4

Left arrow back to the main menu to save the changes.

4. Mapping the DS0s For more details on the configuration parameters discussed in this section, refer to the following pages: DS0 Map menus beginning on page 180

186

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 187

Total Access 850 System Manual

Section 4 User Interface Guide

DS0 Mapping Instructions Step 1

Action From the main menu, select DS0 MAPS. Verify that the ACTIVE MAP is set to either MAP 1 or MAP 2. This is the map that is actively running on the unit. The unit has the ability to store two maps.

2

•

To edit the current map, press <ENTER> on EDIT/VIEW MAP 1 to view the map. (If Map 1 is the Active Map)

•

To edit the standby map, press <ENTER> on EDIT/VIEW MAP 2 to view the map. (If Map 2 is the Active Map)

The DS0 listed on the left side of the menu corresponds to DS0s (1 through 24) on the network T1 interface. At least one DS0 must be mapped to the ROUTER to utilize the Total Access 850 for routing purposes. 3

Scroll down to the DS0 that will be mapped. (Any DS0 can be mapped to the router.)

4

Set the SERVICE for the DS0 that you are mapping to TA IAD.

5

Set the PORT of the DS0 that you are mapping to ROUTER 64K or ROUTER 56K.

6

Map all the DS0s as desired, and exit this menu by pressing the left arrow button. Your changes will automatically save when exiting the map.

7

Make sure the ACTIVE MAP is set to the correct map (the map you want running) before exiting the DS0 MAPS menu.

8

Left arrow back to the main menu.

64203376L1-1B

© 2004 ADTRAN, Inc.

187

Page 188

Section 4 User Interface Guide

Total Access 850 System Manual

Appendix B. Configuring the Unit for Bridging Initial Setup It is best to configure Total Access 850 TDM applications by following the order of the top-level menus. For example, first configure the system parameters using the SYSTEM INFO and SYSTEM CONFIG menus. Next, configure the Layer 1 parameters using the INTERFACES menu. Once the Layer 1 information is configured, proceed to the Layer 2 setup using the L2 PROTOCOL menus. Follow the Layer 2 setup with the data “routing” menus (either BRIDGE or ROUTER). Establish packet forwarding and blocking using the SECURITY menus. Lastly, configure the physical mappings using the DS0 MAPS menus. The following example provides step by step instructions for configuring the Total Access 850 T1 TDM system (INTERFACES through DS0 MAPS) for a standard bridging application. System Info and System Config parameters should be set according to your system need. Refer to System Info on page 73 and System Config on page 75 for more details.

1. Setting up the Interfaces For more details on the configuration parameters discussed in this section, refer to the following pages: Network T1 menus beginning on page 94 Ethernet menus beginning on page 101 T1 Interface Setup Instructions Step

Action

1

From the main menu, select INTERFACES.

2

Highlight the CONFIG menu for the T1 interface and press <ENTER>.

3

Right arrow to select FORMAT and choose ESF or SF.

This format must match the format used by the other units in the network.

4

Set the LINE CODE to B8ZS or AMI.

This line code must match the line code used by the other units in the network.

188

5

Set the EQUALIZATION or line build out. The default setting of 0 DB is usually sufficient.

6

Set the CSU LPBK option to ENABLE, DISABLE, or DISABLE ALL based on whether looping to this unit from another unit will be allowed.

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 189

Total Access 850 System Manual

Section 4 User Interface Guide

Ethernet Interface Setup Instructions Most applications should not require a manual setup for the Ethernet interface. By default, the Ethernet interface is configured to auto-detect the data rate (as either 10 or 100 Mbps). The following steps disable the auto-negotiation parameter and manually configure the interface. Step

Action

1

From the main menu, select INTERFACES.

2

Highlight the CONFIG menu for the ETH interface and press <ENTER>.

3

Use the right arrow to select AUTONEGOTIATION and press <ENTER>. Use the down arrow to choose OFF.

4

Select the DATA RATE field and specify either 10BASET or 100BASET.

5

Select the DUPLEX TYPE field and specify either HALF DUPLEX or FULL DUPLEX.

2. Configuring the Layer 2 Protocol For more details on the configuration parameters discussed in this section, refer to the following pages: Layer 2 Frame Relay Protocol menus beginning on page 121 Layer 2 PPP Protocol menus beginning on page 118 Layer 2 Ethernet menus beginning on page 144 Layer 2 Protocol (FRE) Configuration – T1 Interface Step

Action

1

From the main menu, select L2 PROTOCOL and press <ENTER>.

2

Use the arrow keys to select the PROTOCOL field for the T1 interface. Press <ENTER>. Select FRE from the list of available protocols.

3

Highlight the CONFIG menu for the T1 interface and press <ENTER>.

4

Set the MAINTENANCE PROTOCOL to ANNEX D (ANSI), ANNEX A (q933a), LMI, OR STATIC (no sig).

The MAINTENANCE PROTOCOL should be set based on the Frame Relay switch.

5

Down arrow and press <ENTER> on DLCI MAPPING. Press the right arrow key to create an entry. To create additional entries, highlight the NUM field and press the <I> key. To delete an entry, highlight the NUM field for the entry to delete and press the <D> key.

6

Set ACTIVE to YES.

64203376L1-1B

© 2004 ADTRAN, Inc.

189

Page 190

Section 4 User Interface Guide

Total Access 850 System Manual

Layer 2 Protocol (FRE) Configuration – T1 Interface (Continued) 7

Set DLCI to the DLCI number. This DLCI should match what is programmed in the network Frame Relay switch.

8

Set mode to BRIDGE ALL. Using this menu you also have the option to route only IP packets and bridge all other data packets (ROUTE IP/BRIDGE OTHER) or route all IP data packets on this PVC (ROUTE IP).

9

Left arrow back to the main menu to save the changes.

Layer 2 Protocol (PPP) Configuration – T1 Interface Step

Action

1

From the main menu, select L2 PROTOCOL and press <ENTER>.

2

Use the arrow keys to select the PROTOCOL field for the T1 interface. Press <ENTER>. Select PPP from the list of available protocols.

3

Highlight the CONFIG menu for the T1 interface and press <ENTER>.

4

Set mode to BRIDGE ALL. Using this menu you also have the option to route only IP packets and bridge all other data packets (ROUTE IP/BRIDGE OTHER) or route all IP data packets on this connection (ROUTE IP).

5

Highlight AUTHENTICATION and press <ENTER> to change options related to how the link is established. Default is TX METHOD = NONE and RX METHOD = NONE. If TX METHOD and RX METHOD are set to any option other than NONE, TX/RX USERNAME and PASSWORD options appear. The Total Access 850 supports various combinations of PAP, CHAP, and EAP for PPP authentication.

6

Left arrow out of the AUTHENTICATION menus, highlight the PPP menu, and press <ENTER>. Use the PPP menus to configure parameters associated with the PPP link. Refer to L2 Protocol (T1 TDM–T1–PPP) > Config on page 118 for more details.

7

Left arrow back to the main menu to save the changes.

Layer 2 Protocol Configuration – Ethernet Interface Step

190

Action

1

From the main menu, select L2 PROTOCOL and press <ENTER>.

2

Highlight the CONFIG menu for the ETH (Ethernet) interface and press <ENTER>.

3

Set mode to BRIDGE ALL. Using this menu you also have the option to route only IP packets and bridge all other data packets (ROUTE IP/BRIDGE OTHER) or route all IP data packets on this connection (ROUTE IP). Refer to L2 Protocol (ALL–ETH–802.3) > Config on page 144 for more details.

4

Left arrow back to the main menu to save the changes.

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 191

Total Access 850 System Manual

Section 4 User Interface Guide

3. Verifying the Bridge Options For more details on the configuration parameters discussed in this section, refer to the following pages: Bridge menus beginning on page 145 Bridge Options Step

Action

1

From the main menu, select BRIDGE and press <ENTER>.

2

Use the right arrow key to highlight CONFIG and press <ENTER>.

3

Select INTERFACES and press <ENTER>. Verify that the desired interface is listed in this table.

4

Left arrow back to the BRIDGE > CONFIG menu.

5

Select BRIDGE TABLE and set the BRIDGE TABLE AGING to the desired time (in minutes) it takes an entry to age out of the Bridge table.

6

Left arrow back to the main menu to save the changes.

4. Mapping the DS0s For more details on the configuration parameters discussed in this section, refer to the following pages: DS0 Map menus beginning on page 180

DS0 Mapping Instructions Step 1

Action From the main menu, select DS0 MAPS. Verify that the ACTIVE MAP is set to either MAP 1 or MAP 2. This is the map that is actively running on the unit. The unit has the ability to store two maps.

2

•

To edit the current map, press <ENTER> on EDIT/VIEW MAP 1 to view the map. (If Map 1 is the Active Map)

•

To edit the standby map, press <ENTER> on EDIT/VIEW MAP 2 to view the map. (If Map 2 is the Active Map)

The DS0 listed on the left side of the menu corresponds to DS0s (1 through 24) on the network T1 interface. At least one DS0 must be mapped to the ROUTER to utilize the Total Access 850 for routing purposes. 3

Scroll down to the DS0 that will be mapped. (Any DS0 can be mapped to the router.)

4

Set the SERVICE for the DS0 that you are mapping to TA IAD.

64203376L1-1B

© 2004 ADTRAN, Inc.

191

Page 192

Section 4 User Interface Guide

Total Access 850 System Manual

DS0 Mapping Instructions (Continued)

192

5

Set the PORT of the DS0 that you are mapping to ROUTER 64K or ROUTER 56K.

6

Map all the DS0s as desired, and exit this menu by pressing the left arrow button. Your changes will automatically save when exiting the map.

7

Make sure the ACTIVE MAP is set to the correct map (the map you want running) before exiting the DS0 MAPS menu.

8

Left arrow back to the main menu.

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 193

Total Access 850 System Manual

Section 4 User Interface Guide

Appendix C. Configuring the Unit for Voice Applications Initial Setup It is best to configure Total Access 850 TDM applications by following the order of the top-level menus. For example, first configure the system parameters using the SYSTEM INFO and SYSTEM CONFIG menus. Next, configure the Layer 1 parameters using the INTERFACES menu. Once the Layer 1 information is configured, proceed to the Layer 2 setup using the L2 PROTOCOL menus. Follow the Layer 2 setup with the data “routing” menus (either BRIDGE or ROUTER). Establish packet forwarding and blocking using the SECURITY menus. Lastly, configure the physical mappings using the DS0 MAPS menus. The following example provides step by step instructions for configuring the Total Access 850 T1 TDM system (INTERFACES through DS0 MAPS) for a standard voice application. System Info and System Config parameters should be set according to your system need. Refer to System Info on page 73 and System Config on page 75 for more details.

1. Setting up the Interfaces For more details on the configuration parameters discussed in this section, refer to the following pages: Network T1 menus beginning on page 94 FXS menus beginning on page 103 T1 Interface Setup Instructions Step

Action

1

From the main menu, select INTERFACES.

2

Highlight the CONFIG menu for the T1 interface and press <ENTER>.

3

Right arrow to select FORMAT and choose ESF or SF.

This format must match the format used by the other units in the network.

4

Set the LINE CODE to B8ZS or AMI.

This line code must match the line code used by the other units in the network.

64203376L1-1B

5

Set the EQUALIZATION or line build out. The default setting of 0 DB is usually sufficient.

6

Set the CSU LPBK option to ENABLE, DISABLE, or DISABLE ALL based on whether looping to this unit from another unit will be allowed.

© 2004 ADTRAN, Inc.

193

Page 194

Section 4 User Interface Guide

Total Access 850 System Manual

FXS Interface Setup Instructions Step

Action

1

From the main menu, select INTERFACES.

2

Highlight the CONFIG menu for the FXS interface and press <ENTER>.

3

Right arrow to select MODE and choose LOOP START, GROUND START, TANDEM (E&M), TR08 SINGLE, TR08 UVG, or DPO.

This mode should be set based on the network configuration and the operation of each FXS port. All FXS ports are independent and do not need to have the same mode.

194

4

Set the TX (dB) or transmit direction level for each port. The default value is recommended.

5

Set the RX (dB) or received direction level for each port. The default value is recommended.

6

Set the SVC MODE to IN SERVICE to activate the port.

7

Set the LINE Z (line impedance) of each port based on the size of the network. The default value is recommended.

8

Set the MSG IND to DISABLE or ENABLE. When set to ENABLE, talk path is always open, even in on-hook conditions, in order for FXS message tones to pass through. Disabling this feature will allow higher on-hook voltage but will not allow on-hook messaging other than caller ID.

9

Configure the on-hook battery voltage using the BATT MODE field. For most IAD installs, the FXS loop is short with 6 to 7 V present on tip / ring. To reduce power dissipated during off-hook conditions, the battery is lowered for short loop lengths. When set to AUTO SWITCH, the IAD uses a higher on-hook battery voltage (48-52 V). When off-hook, it automatically switches to low battery (24-26 V) to minimize power dissipation. When set to LOW BATTERY mode, the higher battery is not used and the voltage is a constant 26 V even while on-hook. The tip/ring voltage is reduced to 26 V when using the LOW BATTERY mode.

10

Specify the interval of battery removal during a forward disconnect state using the FWD DISC TIMER field. Choices are FOLLOW SWITCH (default), 500MS, 750MS, 1000MS, and 2000MS. When using ATM mode, there is an additional choice of IGNORE SWITCH. If the timer is set to FOLLOW SWITCH, the Total Access 850 will follow the switch at all times; this is normal operation. If a time period has been selected, the Total Access 850 will remove battery for the specified time period OR as long as the switch requests battery removal, whichever is longer. For example, if the timer expires but the switch continues to request battery removal, the Total Access 850 will follow the switch and continue to remove battery. For ATM mode, if the timer is set to IGNORE SWITCH, the IAD will never remove battery.

© 2004 ADTRAN, Inc.

64203376L1-1B