Page 175
Total Access 850 System Manual
Section 4 User Interface Guide
DEST PORT
IP destination port number used for comparison. Value is in decimal format. Range: 0 - 65535. Default is 0. DEST PORT COMP
Type of comparison that is performed. Default is NONE. = means ports equal to NOT = means port not equal to
> means port greater than < means port less than
None - means the source port is not compared PROTOCOL
Protocol used for comparison. Value is in decimal format. Range: 0 - 255. Default is 0. PROTOCOL COMP
Type of comparison that is performed. Default is NONE. = means ports equal to NOT = means port not equal to
> means port greater than < means port less than
None - means the source port is not compared TCP ESTAB
Yes - only when TCP established No - only when TCP not established Ignore - ignore TCP flags (def)
SECURITY > FILTERS > INTERFACES The unit can block packets in and out of an interface by use of the filters. They are set up in two steps: 1) define the types of packets that would be of interest in the SECURITY > FILTERS > FILTER DEFINES menu, and 2) set up the filter type and combination of defines that will cause a packet block.
SECURITY > FILTERS > INTERFACES (ETH) Define the filters for the Ethernet interface from this menu.
64203376L1-1B
© 2004 ADTRAN, Inc.
175
Page 176
Section 4 User Interface Guide
Total Access 850 System Manual
SECURITY > FILTERS > INTERFACES (ETH) > SUB-INTERFACE The Ethernet sub-interface is 802.3[1.0]. This is a read-only field.
SECURITY > FILTERS > INTERFACES (ETH) > SET-UP Enable the Ethernet interface filtering and define filters from this menu. IN FROM VC
The packets which come into the unit can be filtered in three ways:
DISABLE (DEF)
Turns off packet input filtering. No incoming packets are blocked.
BLOCK ALL
All incoming packets from the WAN are blocked except as defined in the SECURITY > FILTERS > INTERFACES > SETUP > IN EXCEPTIONS list.
FORWARD ALL
All incoming packets from the WAN are not blocked except as defined in the SECURITY > FILTERS > INTERFACES > SETUP > IN EXCEPTIONS list.
IN EXCEPTIONS
This is a list of up to 32 filter entries which can be combined using the operations field. The operations are performed in the order they appear on the list. #
Indicates the entry number in the In Exceptions table. ACTIVE
Turns this entry active when set to YES. Default is NO. TYPE
Selects the filter define list to reference (default is MAC). MAC from the SECURITY > FILTERS > FILTER DEFINES > MAC FILTER DEFINES list.
PATTERN from the SECURITY > FILTERS > FILTER DEFINES > PATTERN FILTER DEFINES list.
IP from the SECURITY > FILTERS > FILTER DEFINES > IP FILTER DEFINES list.
FILTER LIST NAME
Selects between filters defined in the list. Default is no entry in filter list name.
176
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 177
Total Access 850 System Manual
Section 4 User Interface Guide
NEXT OPER
The next operation to use to combine with the next filter in the list (default is END). END the last filter to combination.
AND logically AND this filter with the next filter in the list.
OR logically OR this filter with the next filter in the list.
HIT COUNT
Displays the number of packets that match the criteria for the defined filter. OUT TO VC
The packets which come from the unit to the WAN can be filtered in three ways: DISABLE (DEF)
Turns off packet outputs filtering. No outgoing packets are blocked.
BLOCK ALL
All outgoing packets to the WAN are blocked except as defined in the SECURITY > FILTERS > INTERFACES > SETUP > OUT EXCEPTIONS list.
FORWARD ALL
All outgoing packets to the WAN are not blocked except as defined in the SECURITY > FILTERS > INTERFACES > INTERFACES > SETUP > OUT EXCEPTIONS list.
OUT EXCEPTIONS
This is a list of up to 32 filter entries which can be combined using the operations field. The operations are performed in the order they appear on the list. #
Indicates the entry number in the In Exceptions table. ACTIVE
Turns this entry active when set to YES. Default is NO. TYPE
Selects the filter define list to reference (default is MAC):
64203376L1-1B
MAC from the SECURITY > FILTERS > FILTER DEFINES > MAC FILTER DEFINES list.
PATTERN from the SECURITY > FILTERS > FILTER DEFINES > PATTER FILTER DEFINES list.
IP from the SECURITY > FILTERS > FILTER DEFINES > IP FILTER DEFINES list.
© 2004 ADTRAN, Inc.
177
Page 178
Section 4 User Interface Guide
Total Access 850 System Manual
FILTER LIST NAME
Selects between filters defines in the list. Default is no entry in filter list name. NEXT OPER
The next operation to use to combine with the next filter in the list (default is END): END the last filter to combination.
AND logically AND this filter with the next filter in the list.
OR logically OR this filter with the next filter in the list.
HIT COUNT
Displays the number of packets that match the criteria for the defined filter.
SECURITY > RADIUS SERVER The parameters for the RADIUS SERVER are configured in this menu.
Telnet radius is only available in A.04 firmware or later.
SECURITY > RADIUS SERVER > SERVER 1 This is the IP address of the first RADIUS SERVER that the unit should attempt to communicate with when authenticating a Telnet session. Default is 0.0.0.0.
SECURITY > RADIUS SERVER > SERVER 2 This is the IP address of the second RADIUS SERVER that the unit should attempt to communicate with when the primary server does not respond. Default is 0.0.0.0.
SECURITY > RADIUS SERVER > SERVER 3 This is the IP address of the third RADIUS SERVER that the unit should attempt to communicate with when the primary server does not respond. Default is 0.0.0.0.
SECURITY > RADIUS SERVER > UDP PORT This is the UDP port the unit should use when communicating with the RADIUS SERVER. The default is 1812, which the commonly used port.
SECURITY > RADIUS SERVER > SECRET The RADIUS SERVER and unit share this text string. It is used by the RADIUS SERVER to authenticate the unit, the RADIUS client. The factory default is not to use a secret.
178
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 179
Total Access 850 System Manual
Section 4 User Interface Guide
SECURITY > RADIUS SERVER > RETRY COUNT (1-10) This is the number of times the unit should send a request packet tho the RADIUS SERVER without a response before giving up. If the number of attempts to communicate with the primary server is equal to the retry count, the second server (if defined) is tried. If the second server does not respond within the retry count the third server (if defined) is tried. If the third server does not respond within the retry count, the Telnet session is not authenticated and is dropped. The default is 5.
DS0 MAPS
The DS0 Maps configuration fields only apply for T1 TDM applications.
The DS0 MAPS menu allows you to map data and voice ports to the network T1 time slots. You may edit either of the two maps at any time. If you make changes to the current map, only those DS0s that have changed will be updated (unchanged DS0s will not be affected.) The DS0 menu is shown in Figure 13.
Figure 13. DS0 Maps Menu
64203376L1-1B
© 2004 ADTRAN, Inc.
179
Page 180
Section 4 User Interface Guide
Total Access 850 System Manual
DS0 MAPS > ACTIVE MAP Activates one of the two dedicated maps (MAP 1 or MAP 2), or the DUAL T1 MAP. In the DUAL T1 mode, the built-in DSX-1 interface DSX[3] can be utilized as a secondary T1 connection. In DUAL T1 mode, the second T1 is limited to voice connections on FXS and FXO modules. For example, the user may map all 24 DS0s on the network T1 to the router, and on the second T1 (DSX-1 interface) map all 24 DS0s to the FXS cards. Default is MAP 1.
DS0 MAPS > APPLY TEMPLATE TO MAP 1 Choices are CURRENT MAP 1, CURRENT MAP 2, D4 MAP, D1D MAP, FULL ROUTER, and CLEAR MAP. Default is CURRENT MAP 1. D4 MAP automaps the voice port in a 1-to-1 configuration. D1D MAP maps voice ports in an SLC-96 configuration. FULL ROUTER maps all 24 DS0s to the router at 64K. CLEAR MAP clears the entire map.
DS0 MAPS > EDIT/VIEW MAP 1 Define map 1. The map allows the user to assign services and ports to the individual DS0s 1-24.
In the default configuration for TDM A.04.XX firmware, DS0 24 is mapped to the router at 64K on Map 1.
DS0 MAPS > EDIT/VIEW MAP 1 > DS0 Displays the network T1 time slot to be assigned.
DS0 MAPS > EDIT/VIEW MAP 1 > SLOT When you select this option, a list of all of the slots and the modules displays. This first option OPEN, when unassigns the slot if selected. For modules, the slot number and name are shown. For example, FXS indicates that an FXS card is installed. Use TA IAD to map network timeslot to the V.35 port or to the router. Pick the appropriate server, and press <ENTER>. Default is OPEN.
DS0 MAPS > EDIT/VIEW MAP 1 > PORT When you select this option, a list of ports appears. Pick the appropriate port, and press <ENTER>. The selection list shows only the remaining ports available to be assigned. It may be necessary to unassign a port in order to reassign it elsewhere.
180
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 181
Total Access 850 System Manual
Section 4 User Interface Guide
DS0 MAPS > EDIT/VIEW MAP 1 > RBS Robbed Bit Signaling. Default is N/A. Once a SLOT and port are assigned, this will automatically change to ON or OFF. The unit automatically assigns OFF where RBS is not an option. ON preserves the signaling bits between the connections. OFF ignores the signaling bits. For the FXS, RBS defaults to ON. The RBS parameter remains at N/A for the TA IAD, because RBS is not applicable to data connections.
Map 2 menus are identical to Map 1. Please use the menu explanations above for Map 2.
64203376L1-1B
© 2004 ADTRAN, Inc.
181
Page 182
Section 4 User Interface Guide
4.
Total Access 850 System Manual
APPENDICES (T1 TDM APPLICATIONS) Appendix A. Configuring the Unit for Routing
Initial Setup It is best to configure Total Access 850 TDM applications by following the order of the top-level menus. For example, first configure the system parameters using the SYSTEM INFO and SYSTEM CONFIG menus. Next, configure the Layer 1 parameters using the INTERFACES menu. Once the Layer 1 information is configured, proceed to the Layer 2 setup using the L2 PROTOCOL menus. Follow the Layer 2 setup with the data “routing” menus (either BRIDGE or ROUTER). Establish packet forwarding and blocking using the SECURITY menus. Lastly, configure the physical mappings using the DS0 MAPS menus. The following example provides step by step instructions for configuring the Total Access 850 T1 TDM system (INTERFACES through DS0 MAPS) for a standard routing application. System Info and System Config parameters should be set according to your system need. Refer to System Info on page 73 and System Config on page 75 for more details.
1. Setting up the Interfaces For more details on the configuration parameters discussed in this section, refer to the following pages: Network T1 menus beginning on page 94 Ethernet menus beginning on page 101 T1 Interface Setup Instructions Step
Action
1
From the main menu, select INTERFACES.
2
Highlight the CONFIG menu for the T1 interface and press <ENTER>.
3
Right arrow to select FORMAT and choose ESF or SF.
This format must match the format used by the other units in the network.
4
Set the LINE CODE to B8ZS or AMI.
This line code must match the line code used by the other units in the network.
182
5
Set the EQUALIZATION or line build out. The default setting of 0 DB is usually sufficient.
6
Set the CSU LPBK option to ENABLE, DISABLE, or DISABLE ALL based on whether looping to this unit from another unit will be allowed.
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 183
Total Access 850 System Manual
Section 4 User Interface Guide
Ethernet Interface Setup Instructions Most applications should not require a manual setup for the Ethernet interface. By default, the Ethernet interface is configured to auto-detect the data rate (as either 10 or 100 Mbps). The following steps disable the auto-negotiation parameter and manually configure the interface. Step
Action
1
From the main menu, select INTERFACES.
2
Highlight the CONFIG menu for the ETH interface and press <ENTER>.
3
Use the right arrow to select AUTONEGOTIATION and press <ENTER>. Use the down arrow to choose OFF.
4
Select the DATA RATE field and specify either 10BASET or 100BASET.
5
Select the DUPLEX TYPE field and specify either HALF DUPLEX or FULL DUPLEX.
2. Configuring the Layer 2 Protocol For more details on the configuration parameters discussed in this section, refer to the following pages: Layer 2 Frame Relay Protocol menus beginning on page 121 Layer 2 PPP Protocol menus beginning on page 118 Layer 2 Ethernet menus beginning on page 144 Layer 2 Protocol (FRE) Configuration – T1 Interface Step
Action
1
From the main menu, select L2 PROTOCOL and press <ENTER>.
2
Use the arrow keys to select the PROTOCOL field for the T1 interface. Press <ENTER>. Select FRE from the list of available protocols.
3
Highlight the CONFIG menu for the T1 interface and press <ENTER>.
4
Set the MAINTENANCE PROTOCOL to ANNEX D (ANSI), ANNEX A (q933a), LMI, OR STATIC (no sig).
The MAINTENANCE PROTOCOL should be set based on the Frame Relay switch.
5
Down arrow and press <ENTER> on DLCI MAPPING. Press the right arrow key to create an entry. To create additional entries, highlight the NUM field and press the <I> key. To delete an entry, highlight the NUM field for the entry to delete and press the <D> key.
6
Set ACTIVE to YES.
64203376L1-1B
© 2004 ADTRAN, Inc.
183
Page 184
Section 4 User Interface Guide
Total Access 850 System Manual
Layer 2 Protocol (FRE) Configuration – T1 Interface (Continued) 7
Set DLCI to the DLCI number. This DLCI should match what is programmed in the network Frame Relay switch.
8
Set mode to ROUTE IP. Using this menu you also have the option to route only IP packets and bridge all other data packets (ROUTE IP/BRIDGE OTHER) or bridge all data packets on this PVC (BRIDGE ALL).
9
Left arrow back to the main menu to save the changes.
Layer 2 Protocol (PPP) Configuration – T1 Interface Step
Action
1
From the main menu, select L2 PROTOCOL and press <ENTER>.
2
Use the arrow keys to select the PROTOCOL field for the T1 interface. Press <ENTER>. Select PPP from the list of available protocols.
3
Highlight the CONFIG menu for the T1 interface and press <ENTER>.
4
Set mode to ROUTE IP. Using this menu you also have the option to route only IP packets and bridge all other data packets (ROUTE IP/BRIDGE OTHER) or bridge all data packets on this connection (BRIDGE ALL).
5
Highlight AUTHENTICATION and press <ENTER> to change options related to how the link is established. Default is TX METHOD = NONE and RX METHOD = NONE. If TX METHOD and RX METHOD are set to any option other than NONE, TX/RX USERNAME and PASSWORD options appear. The Total Access 850 supports various combinations of PAP, CHAP, and EAP for PPP authentication. Refer to L2 Protocol (T1 TDM–T1–PPP) > Config > Authentication on page 118 for more details.
6
Left arrow out of the AUTHENTICATION menus, highlight the PPP menu, and press <ENTER>. Use the PPP menus to configure parameters associated with the PPP link. Refer to L2 Protocol (T1 TDM–T1–PPP) > Config on page 118 for more details.
7
Left arrow back to the main menu to save the changes.
Layer 2 Protocol Configuration – Ethernet Interface Step
184
Action
1
From the main menu, select L2 PROTOCOL and press <ENTER>.
2
Highlight the CONFIG menu for the ETH (Ethernet) interface and press <ENTER>.
© 2004 ADTRAN, Inc.
64203376L1-1B