Total Access 850 System Manual: Detail Level Procedures, pages 253 to 262

Pages 253 to 262 of 292, from Total Access 850 System Manual

The original document is the PDF (3.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Adtran 1200375L1

Page 253

DLP-14 A.03 to A.04 Firmware Upgrade Introduction The Total Access line of Integrated Access Devices includes both the ATM and TDM versions of the Total Access 850. Until now, the Total Access TDM units have been running firmware version A.03.xx. Recently, A.04.xx has been released to support the TDM Total Access IADs. The development of A.04.xx code is a significant step in the evolution of the Total Access product line, as it allows all Total Access family members to share the same base code. This means that features and fixes are more easily implemented and are propagated across the product line. The two possible A.03 to A.04 upgrade paths are described in this DLP.

The choice of upgrade path will determine whether the unit's configuration is saved.

Since the A.03 and A.04 firmware loads are significantly different, the text configuration files for the two revisions are also different. It is recommended that the customer save a text configuration file for both the A.03 revision (prior to the upgrade) and for the A.04 revision (after completion of the upgrade). Refer to DLP-9, Saving the Current Configuration Using TFTP, DLP-11, Saving and Transferring a Current Configuration Using XMODEM, or DLP-13, Saving and Loading Text Configuration using Terminal Command Line, for further instructions on how to save the configuration.

To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.

Prerequisite Procedures Obtain the A.04 firmware and the A.03.90 (Transition Build) firmware from the ADTRAN website (http://www.ADTRAN.com).

For the Total Access 850 units, select SERVICE/SUPPORT > TECHNICAL SUPPORT > TOTAL ACCESS PRODUCTS > TOTAL ACCESS 850.

If further assistance is required, contact ADTRAN Technical Support at 1-888-4ADTRAN.

64203376L1-1B

© 2004 ADTRAN, Inc.

253

Page 254

Section 5 DLP-14

Total Access 850 System Manual

Tools and Materials Required • • •

VT100 compatible terminal or computer with terminal emulation software Appropriate cable to connect terminal to the unit (customer-provided) DB-9 male to DB-9 female cable (customer provided) for connecting to the CRAFT port on the front of the RCU DB-9 female to RJ-45 female adapter (customer provided) for connecting to the CRAFT port on the rear of the unit

•

Perform the steps below in the order listed.

Upgrade From A.03 to A.03.90 (Transition Build) to A.04 1. Upgrade the firmware from A.03 to A.03.90 (Transition Build) firmware. See DLP-7 (TFTP) or DLP-8 (XMODEM) for instructions on how to perform this upgrade. 2. Once the upgrade to A.03.90 is complete, immediately upgrade the unit to A.04. See DLP-7 (TFTP) or DLP-8 (XMODEM) for instructions on how to perform this upgrade.

Upgrading from A.03 to A.03.90 (Transition Build) to A.04 will save the unit's configuration.

Upgrade From A.03 to A.04 Directly 1. Upgrade the firmware from A.03 to A.04 firmware. See DLP-7 (TFTP) or DLP-8 (XMODEM) for instructions on how to perform this upgrade. 2. The unit must then be factory defaulted by one of the following methods:

•

Select SYSTEM UTILITY>TERMINAL MODE. At the > prompt, type fac. You will then see “Restore Factory Defaults and Reset Unit? (press 'y').” Press the y key to confirm default. The unit will then automatically reset.

3. If connected to the RCU faceplate CRAFT or rear CRAFT port, set DIP-switch 2 (on the RCU) to the on position and power reset the unit. You will then be prompted to confirm the factory default.

DIP-switch services are not available on 3rd Generation RCUs.

To avoid a configuration loss in the event of a power failure, return DIP-switch 2 to the off position before resuming normal operation.

254

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 255

Total Access 850 System Manual

Section 5 DLP-14

4. Reconfigure the unit for the specific application.

Upgrading from A.03 to A.04 directly (or from A.04 to A.03 directly) will erase the unit's configuration.

64203376L1-1B

© 2004 ADTRAN, Inc.

255

Page 256

Section 5 DLP-14

256

Total Access 850 System Manual

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 257

DLP-15 Using the ADTRAN Utility Syslog Introduction The Total Access 850 Syslog Utility records various message types at settable threshold levels to an external Syslog server (software supplied with the Total Access 850 system ADTRAN Utilities).

Prerequisite Procedures This procedure assumes that the Total Access 850 unit is connected to an IP network and is powered up.

Tools and Materials Required •

Syslog server (provided on Total Access 850 System CD in ADTRAN Utilities)

To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.

Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.

64203376L1-1B

© 2004 ADTRAN, Inc.

257

Page 258

Section 5 DLP-15

Total Access 850 System Manual

Setting up the Total Access 850 to use Syslog: 1. Log in to the system with maximum rights (see DLP-2, Logging in to the System). Once you have logged into the Total Access 850, go to SYSTEM CONFIG/SYSLOG. Set the options as follows:

• • •

SYSLOG IP: Enter the IP address of the PC where the Syslog host resides SYSLOG FORMAT: Specify the Syslog format as either ADTRAN (to work with ADTRAN Utilities) or UNIX (to work with a standard UNIX Syslog server) SYSLOG FACILITY: Specify the facility destination of log events; Options are LOCAL0 to LOCAL7

Setting Up the Syslog Host: 1. On your PC, go to START/PROGRAMS/ADTRAN UTILITIES/SYSLOG. When the Syslog window opens, you will see LOCAL0 through LOCAL7 listed on the left. This should correspond with the HOST FACILITY specified in the Total Access 850. The Syslog program must be open on your PC in order for it to record Total Access 850 information. The Syslog files can be viewed through the Syslog window, and they are also available under the ADTRAN Utilities Folder named LOCALX.TXT, where X can equal 0 through 7. You can also view the LOCALX.TXT file by clicking on EDIT LOG.

258

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 259

Total Access 850 System Manual

Section 5 DLP-15

.

Additional Syslog Features:

•

The MONITOR feature allows all Syslog messages to be prefiltered by SYSTEM NAME, SOURCE, SLOT, and PORT before displaying these messages to the user and logging the message to the pre-designated monitor log file. Various filter options may be defined by selecting SOURCE. The figure below shows the SOURCE FILTER window. When the MONITOR button is selected, the file will be logged to LOCAL8.TXT. To look at the text file, click on the EDIT LOG button on the left side of the Syslog screen. Only the SOURCE options that are selected with an ‘x’ will be displayed in the Syslog file. In this example, all options are displayed.

64203376L1-1B

© 2004 ADTRAN, Inc.

259

Page 260

Section 5 DLP-15

Total Access 850 System Manual

•

Under the LOG FILES menu option, the user may erase log files, define Red events, set priorities, and clear Red events. The ERASE LOG FILES option erases the specified text log file. • DEFINE RED EVENTS allows the user to predefine a message priority condition so that if the condition occurs, the file is highlighted in red. In the figure below, any CRITICAL or MAJOR condition causes any LOCAL0 through LOCAL7 facility to become highlighted in red if it receives a critical or major alarm.

•

The PROPERTIES menu allows the user to specify the types of messages to be logged to an ASCII text file. Mark the lowest priority Syslog message you want to log to the Syslog server text file. For example, the figure below shows that all messages will be logged to the text file.

•

The HELP menu also explains these features. Click on HELP/CONTENTS/SYSLOG HOST DAEMON for further explanation of Syslog features.

260

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 261

DLP-16 Connecting the Alarm Contacts and the External Input Introduction Alarm connections alert the user when a selected alarm condition exists. Pressing the Alarm Cut-Off (ACO) switch on the front panel of the Total Access 850 PSU clears the alarm. This procedure details the steps which must be performed to use the Total Access 850 alarm connections and the ACO switch. This procedure should be performed at installation on each Total Access 850 shelf that is wired out to external office alarm equipment.

Prerequisite Procedures Before beginning this procedure, the Total Access 850 should be mounted in its permanent location.

Tools and Materials Required • • • •

Wire strippers Small Phillips screwdriver 22 or 24 AWG 2-conductor twisted pair cross-connect wire VT100 terminal or PC with VT100 terminal emulation software To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.

Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.

64203376L1-1B

© 2004 ADTRAN, Inc.

261

Page 262

Section 5 DLP-16

Total Access 850 System Manual

Perform the steps below in the order listed.

1. Backplane alarm connections (P5) are labeled as shown in the table below and illustrated in the figure. P3 Wire-Wrap Connections T1 Connections 1

R1

DS1 Ring input from network

2

T1

DS1 Tip input from network

3

R

DS1 Ring output from network

4

T

DS1 Tip output from network

5

Gnd

Ground P5 Wire-Wrap Connections Alarm Connections

1

-48 ALM

DC Alarm output

2

MJVR

Major Alarm Visual Common

3

MJV

Major Alarm Visual

4

MJR

Major Alarm Audible Common

5

MJ

Major Alarm Audible

MJ

MJR

MJV

MJVR

-48VALM

To customer designed remote alarms

You will have to remove the cover to access the contacts. Refer to the Total Access 850 rear view illustration on the next page.

262