For the Adtran 1200375L1

Page 263

Total Access 850 System Manual

Section 5 DLP-16

P5

P7

P6

2. Alarm relay contacts are open during normal operation. The alarm relay contacts close in the event of a local alarm condition or the receipt of an alarm from the T1 Carrier. 3. In a carrier alarm condition such as a Red, Yellow, or Blue (unframed all 1s), various alarm contacts in the PSU close. 4. Carrier alarm conditions cause the Total Access 850 to initiate trunk processing. The following chain of events then occur:

• •

MJ will be directly shorted to MJR. MJV will be directly shorted to MJVR.

5. Contacts MJ and MJR can be overridden manually during an alarm condition by pressing the ACO pushbutton on the PSU faceplate. 6. If the 3-Amp power fuse on the PSU trips, the -48 ALM relay will close, providing a -48 VDC signal on that pin. This alarm cannot be overridden by the ACO pushbutton. Refer to the table below for alarm notifications. Alarm Condition

Relays Activated MJR

MJVR

RED ALARM

X

X

YELLOW ALARM

X

X

AIS ALARM

X

X

PSU POWER FUSE FAILS

X

X

ALARMS ACO DEACTIVATES

X

X

-48 ALM

X

Note: ACO will not deactivate MJR after a power fuse failure.

64203376L1-1B

© 2004 ADTRAN, Inc.

263

Page 264

Section 5 DLP-16

264

Total Access 850 System Manual

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 265

DLP-17 Configuring the Total Access 850 for Dual T1 Maps Introduction The Total Access 850 with firmware A.04.02 or higher has a DUAL T1 MAP feature that allows two network T1 connections for the termination of data and voice applications. The primary network T1 MAP can be configured for internal router usage (FT1/24 DS0s maximum) and to any access module installed. The DSX MAP can be used for FXS/FXO modules in slots 1-6 only. There are several steps that must be followed in order for the Dual T1 Map to be configured successfully. These steps are described in this DLP.

Prerequisite Procedures This procedure assumes that the user has access to the Total Access 850 system menus. Refer to DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port, for details on making a terminal connection to the Total Access 850.

To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.

Electronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.

64203376L1-1B

© 2004 ADTRAN, Inc.

265

Page 266

Section 5 DLP-17

Total Access 850 System Manual

Perform the steps below in the order listed.

1. Connect the Total Access 850 unit to your VT100 system (details found in DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port). 2. Log in to the system with maximum rights (details are in DLP-2, Logging in to the System). 3. From the DS0 MAPS menu, select the ACTIVE MAP option and press <Enter>. 4. From the DS0 MAPS > ACTIVE MAPS menu, select the DUAL T1 MAP option; press <Enter>. Select “Y” for yes to confirm the Active Map change and press <Enter>. The following screen appears.

The second T1 connected to the DSX port may only be used for voice connections (FXS/FXO). The second T1 must be connected to the integrated DSX port, not the DSX-1 Card.

Figure 1. Dual T1 Map

266

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 267

Total Access 850 System Manual

Section 5 DLP-17

5. Edit the Primary T1 Map by pressing <Enter> on EDIT/VIEW T1 MAP [+].The following screen appears.

Figure 2. Primary T1 Map

The T1 Map can be mapped to the internal router or other available access module.

64203376L1-1B

© 2004 ADTRAN, Inc.

267

Page 268

Section 5 DLP-17

Total Access 850 System Manual

6. Edit the Secondary T1 Map (DSX Map) by pressing <Enter> on EDIT/VIEW DSX MAP [+]. The following screen appears.

Figure 3. DSX Map

The DSX Map can be mapped to the FXS and FXO access modules only.

7. Left arrow back to DS0 MAPS and log off by pressing <CTRL+L>.

268

© 2004 ADTRAN, Inc.

64203376L1-1B