Page 47

Total Access 850 System Manual

Section 2 Engineering Guidelines

Table 28. BCU DIP-Switch S1 Options (Continued) Switch

Function

Description

S1-2

Tandem Office Installation

Indicates whether the unit is installed in a Tandem Office installation.

S1-3 S1-4 S1-5

S1-6

64203376L1-1B

Service for: S1-3: B1 S1-4: B2 S1-5: D

Zero Byte Substitution

ON

LULT Mode – indicates an Adjacent-to-Customer configuration and sealing current should be provided (S1-1 ON). LUNT Mode – indicates an Adjacent-to-Switch configuration and no wake-up tones are provided.

OFF

LULT Mode – indicates a Tandem Office Sink configuration and sealing current is not provided. LUNT Mode – indicates a Tandem Office Sink configuration and wake-up tones are provided.

Selects the service level to option the U-BR1TE module to deliver full ISDN (2B+D) or any of the following levels: Service Level

S1-3, S1-4, S1-5

2B+D 2B B1+D B2+D B1 B2 D

ON, ON, ON ON, ON, OFF ON, OFF, ON OFF, ON, ON ON, OFF, OFF OFF, ON, OFF OFF, OFF, ON

Sets the Zero Byte Substitution parameter. The ZBS option must be set the same for the COT and RT. Check local provisioning guidelines. ON

AMI-provisioned carrier.

OFF*

B8ZS-provisioned carrier.

© 2004 ADTRAN, Inc.

47

Page 48

Section 2 Engineering Guidelines

Total Access 850 System Manual

Specifications Table 29 provides the detailed specifications for the Total Access 850 UBR1TE Module. Table 29. UBR1TE Module Specifications Loop Interface (ANSI T1.601) Line

2-wire (tip and ring)

Operating Mode full duplex

Data Rate

160 kbps total; 144 kbps available to customer

Signal Format

2B1Q

Transmit Power

13 dBm to 14 dBm nominal DS1 Facility Interface

BR1/10 compatible equipment. Network Compatibility

ISDN and other digital service, according to TR-NWT-000397

Interface

Mechanical Dimensions

3.125” H x 0.62” W, 1.01” D

Weight

< 1 lb Power

Current Draw

0.023 A maximum (@ -48V) Environmental

Temperature

Operating: -40 °C to +70 °C Storage: -40 °C to + 85 °C

Relative Humidity

Up to 95% noncondensing

Heat Dissipation

1.10 W (maximum)

Compliance Codes Table 30 provides the compliance codes for the Total Access 850 UBR1TE Module. Table 30. UBR1TE Module Compliance Codes

48

CODE

IN

OUT

Power Code (PC)

C

C

Telecommunication Code (TC)

–

X

Installation Code

A

–

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 49

Total Access 850 System Manual

Section 2 Engineering Guidelines

OCU DP Access Module (P/N 1180005L1) The OCU DP Access Module may be used for intra-building networks only. This interface should not be connected to public networks.

The OCU DP module is a single port access module used to provide the interface between a DS0 time slot on the T1 and a 4-wire DDS device at the customer premises. The OCU DP supports up to 18 kft of copper for remote DSU connectivity. This module is currently only supported by BCU L1 and L2. Table 31 gives this pinout. Table 31. OCU DP Pinout Total Access 850 Slot

T/R RX

T1/R1 TX

1

26/1

27/2

2

30/5

31/6

3

34/9

35/10

4

38/13

39/14

5

42/17

43/18

6

46/21

47/22

E&M/TO Access Module (P/N 1180402L1) The E&M/TO Access Module may be used for intra-building networks only. This interface should not be connected to public networks.

The E&M/TO module is a single port Ear and Mouth/Transmit Only access module. The primary application for this module is to provide PBX foreign exchange at the customer premises or tandem central office applications. The E&M/TO module supports both 2- and 4- wire operation. This module is currently only supported by BCU L1 and L2. Table 32 gives the E&M/TO module pinout. Table 32. E&M/TO Pinout

Pin

Pin

64203376L1-1B

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

1

5

9

13

17

21

RING

2

6

10

14

18

22

RING 1

3

7

11

15

19

23

SG LEAD

4

8

12

16

20

24

SB LEAD

26

30

34

38

42

46

TIP

27

31

35

39

43

47

TIP 1

28

32

36

40

44

48

E LEAD

29

33

37

41

45

49

M LEAD

© 2004 ADTRAN, Inc.

49

Page 50

Section 2 Engineering Guidelines

Total Access 850 System Manual

Dual V.35 Access Module (P/N 1180025L1) The Dual V.35 module provides additional V.35 interfaces for customer premises equipment. The module takes up two access slots; therefore three modules (six additional ports) can be added to an empty chassis. The Total Access 850 can support a maximum of seven V.35 interfaces. V.35 ports provided by the Dual V.35 module are accessed on the front of the Total Access 850. This module is currently only supported by the TDM version of the T1 RCU. An ADTRAN 35 ft DB-26/V.35 adapter cable is required (P/N 1200167L1).

Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 33 gives a description of all faceplate LEDs for the Dual V.35 Module when used with the Total Access 850 system. Table 33. Dual V.35 Module Faceplate LEDs For these LEDs...

This color light...

Indicates that...

Status

GREEN the module is operating normally.

RED there is a card failure, or the T1 is down, or there is no valid data transfer occurring.

AMBER there is a test in progress.

Blinking AMBER no DS0s have been assigned to the interface.

TD

GREEN the module is transmitting data to the network interface.

RD

GREEN the module is receiving data from the network and transmitting it out the V.35 interface (to the DTE equipment).

Interface Pinouts Table 34 provides the interface pinout for the DB-26 and V.35 interfaces. Table 34. Dual V.35 Interface Pinout (DB-26 to V.35)

50

Pin (DB-26)

Pin (V.35)

Description

1

A

Frame ground

2,3

–

Unused

4

C

Request to send (RTS)

5

D

Clear to send (CTS)

6

E

Data set ready (DSR)

7

B

Signal ground

8

F

Carrier detect (CD)

9

P

Transmitted data (TD-A) from DTE

10

S

Transmitted data (TD-B) to DTE

11

R

Received data (RD-A) to DTE

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 51

Total Access 850 System Manual

Section 2 Engineering Guidelines

Table 34. Dual V.35 Interface Pinout (DB-26 to V.35) (Continued) 12

T

Received data (RD-B) to DTE

13

U

External TX clock (ETC-A) from DTE

14-16

–

Unused

17

J

Ring indicator (RI)

18

L

LL

19

NN

Test mode (TM) to DTE

20

H

Data terminal ready (DTR) from DTE

21

–

Unused

22

Y

TX clock (TC-A) to DTE

23

AA

TX clock (TC-B) to DTE

24

V

RX clock (RC-A) to DTE

25

X

RX clock (RC-B) to DTE

26

W

External TX clock (ETC-B) from DTE

Specifications Table 35 provides the detailed specifications for the Total Access 850 Dual V.35 Module. Table 35. Dual V.35 Module Specifications

64203376L1-1B

Data Rates

56 kbps to 1.536 Mbps (per interface)

Relative Humidity

Up to 95% noncondensing

Cable Assembly

DB-26 to V.35 P/N 1200167L1

Temperature

Operate at -40 °C to +65 °C Store at -40 °C to +85 °C

Tests

Self-test, DTE loopback, Network Loopback, 511 Pattern generation

Electrical

Voltage

Current

-42 to -56 VDC +3.3 VDC ± 10% +5.0 VDC ± 5% -7.5 VDC ± 10% -24 to -30 VDC

0 mA 20 mA 160 mA 50 mA 0 mA

Dimensions

3 3/16” W x 1 5/16” H x 10 1/8” D

Weight

4.8 ounces

© 2004 ADTRAN, Inc.

51

Page 52

Section 2 Engineering Guidelines

Total Access 850 System Manual

Compliance Codes Table 36 provides the compliance codes for the Total Access 850 Dual V.35 Module. Table 36. Dual V.35 Module Compliance Codes CODE

IN

OUT

Power Code (PC)

C

C

Telecommunication Code (TC)

–

–

Installation Code

A

–

DSX-1 Access Module (P/N 1200385L1) The DSX-1 interface provided on the DSX-1 Access Module may be used for intra-building networks only. This interface should not be connected to public networks.

The DSX-1 Module is a single port (RJ-45) access module that provides a DSX-1 connection for customer premises equipment. This module supports PBXs or other equipment with a DSX-1/FT1 interface. This module is currently supported by the T1 RCU only. Robbed-Bit Signaling is only passed to the DSX-1 Module from the 3rd Generation RCUs. Older RCUs do not have this capability.

Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 37 on page 53 gives a description of all faceplate LEDs for the DSX-1 Module when used with the Total Access 850 system.

52

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 53

Total Access 850 System Manual

Section 2 Engineering Guidelines

Table 37. DSX-1 Module Faceplate LEDs For these LEDs...

This color light...

Indicates that...

Online

OFF there is no power to the system.

GREEN the DSX-1 signal is present and synchronized; the channel is configured for use.

RED there is a present channel alarm on the T1 interface.

Solid AMBER there is a channel test in progress.

Blinking AMBER the card is initializing (during startup).

Interface Pinout Table 38 provides the interface pinout for the provided RJ-45 DSX-1 interface. Table 38. DSX-1 Module Interface Pinout Pin

Name

Description

1

R1 | RXDATA-RING Receive data from the network (RING)

2

T1 | RXDATA-TIP

Receive data from the network (TIP)

3

UNUSED, 4

R | TXDATA-RING

Transmit data towards the network (RING)

5

T | TXDATA-TIP

Transmit data towards the network (TIP)

UNUSED, 6,7,8

Specifications Table 39 provides the detailed specifications for the Total Access 850 DSX-1 Module. Table 39. DSX-1 Module Specifications

64203376L1-1B

Capacity

T1: 1 to 24 DS0s

Framing

ESF and SF(D4)

Line Build Out

DSX-1: 0 to 655 feet in 133-foot increments

Line Coding

AMI (alternate mark inversion) or B8ZS (bipolar 8 zero substitution)

Line Rate

1.544 Mbps, + 75 bps

Relative Humidity

Up to 95% noncondensing

Terminating Impedance

100 ohms + 5%

Temperature

Operate at -0 °C to +50 °C Store at -40 °C to +70 °C

Tests

Self-test, local line, local payload, remote line, and remote payload

© 2004 ADTRAN, Inc.

53

Page 54

Section 2 Engineering Guidelines

54

Total Access 850 System Manual

© 2004 ADTRAN, Inc.

64203376L1-1B