Page 47
Total Access 850 System Manual
Section 2 Engineering Guidelines
Table 28. BCU DIP-Switch S1 Options (Continued) Switch
Function
Description
S1-2
Tandem Office Installation
Indicates whether the unit is installed in a Tandem Office installation.
S1-3 S1-4 S1-5
S1-6
64203376L1-1B
Service for: S1-3: B1 S1-4: B2 S1-5: D
Zero Byte Substitution
ON
LULT Mode – indicates an Adjacent-to-Customer configuration and sealing current should be provided (S1-1 ON). LUNT Mode – indicates an Adjacent-to-Switch configuration and no wake-up tones are provided.
OFF
LULT Mode – indicates a Tandem Office Sink configuration and sealing current is not provided. LUNT Mode – indicates a Tandem Office Sink configuration and wake-up tones are provided.
Selects the service level to option the U-BR1TE module to deliver full ISDN (2B+D) or any of the following levels: Service Level
S1-3, S1-4, S1-5
2B+D 2B B1+D B2+D B1 B2 D
ON, ON, ON ON, ON, OFF ON, OFF, ON OFF, ON, ON ON, OFF, OFF OFF, ON, OFF OFF, OFF, ON
Sets the Zero Byte Substitution parameter. The ZBS option must be set the same for the COT and RT. Check local provisioning guidelines. ON
AMI-provisioned carrier.
OFF*
B8ZS-provisioned carrier.
© 2004 ADTRAN, Inc.
47
Page 48
Section 2 Engineering Guidelines
Total Access 850 System Manual
Specifications Table 29 provides the detailed specifications for the Total Access 850 UBR1TE Module. Table 29. UBR1TE Module Specifications Loop Interface (ANSI T1.601) Line
2-wire (tip and ring)
Operating Mode full duplex
Data Rate
160 kbps total; 144 kbps available to customer
Signal Format
2B1Q
Transmit Power
13 dBm to 14 dBm nominal DS1 Facility Interface
BR1/10 compatible equipment. Network Compatibility
ISDN and other digital service, according to TR-NWT-000397
Interface
Mechanical Dimensions
3.125” H x 0.62” W, 1.01” D
Weight
< 1 lb Power
Current Draw
0.023 A maximum (@ -48V) Environmental
Temperature
Operating: -40 °C to +70 °C Storage: -40 °C to + 85 °C
Relative Humidity
Up to 95% noncondensing
Heat Dissipation
1.10 W (maximum)
Compliance Codes Table 30 provides the compliance codes for the Total Access 850 UBR1TE Module. Table 30. UBR1TE Module Compliance Codes
48
CODE
IN
OUT
Power Code (PC)
C
C
Telecommunication Code (TC)
–
X
Installation Code
A
–
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 49
Total Access 850 System Manual
Section 2 Engineering Guidelines
OCU DP Access Module (P/N 1180005L1) The OCU DP Access Module may be used for intra-building networks only. This interface should not be connected to public networks.
The OCU DP module is a single port access module used to provide the interface between a DS0 time slot on the T1 and a 4-wire DDS device at the customer premises. The OCU DP supports up to 18 kft of copper for remote DSU connectivity. This module is currently only supported by BCU L1 and L2. Table 31 gives this pinout. Table 31. OCU DP Pinout Total Access 850 Slot
T/R RX
T1/R1 TX
1
26/1
27/2
2
30/5
31/6
3
34/9
35/10
4
38/13
39/14
5
42/17
43/18
6
46/21
47/22
E&M/TO Access Module (P/N 1180402L1) The E&M/TO Access Module may be used for intra-building networks only. This interface should not be connected to public networks.
The E&M/TO module is a single port Ear and Mouth/Transmit Only access module. The primary application for this module is to provide PBX foreign exchange at the customer premises or tandem central office applications. The E&M/TO module supports both 2- and 4- wire operation. This module is currently only supported by BCU L1 and L2. Table 32 gives the E&M/TO module pinout. Table 32. E&M/TO Pinout
Pin
Pin
64203376L1-1B
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
1
5
9
13
17
21
RING
2
6
10
14
18
22
RING 1
3
7
11
15
19
23
SG LEAD
4
8
12
16
20
24
SB LEAD
26
30
34
38
42
46
TIP
27
31
35
39
43
47
TIP 1
28
32
36
40
44
48
E LEAD
29
33
37
41
45
49
M LEAD
© 2004 ADTRAN, Inc.
49
Page 50
Section 2 Engineering Guidelines
Total Access 850 System Manual
Dual V.35 Access Module (P/N 1180025L1) The Dual V.35 module provides additional V.35 interfaces for customer premises equipment. The module takes up two access slots; therefore three modules (six additional ports) can be added to an empty chassis. The Total Access 850 can support a maximum of seven V.35 interfaces. V.35 ports provided by the Dual V.35 module are accessed on the front of the Total Access 850. This module is currently only supported by the TDM version of the T1 RCU. An ADTRAN 35 ft DB-26/V.35 adapter cable is required (P/N 1200167L1).
Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 33 gives a description of all faceplate LEDs for the Dual V.35 Module when used with the Total Access 850 system. Table 33. Dual V.35 Module Faceplate LEDs For these LEDs...
This color light...
Indicates that...
Status
GREEN the module is operating normally.
RED there is a card failure, or the T1 is down, or there is no valid data transfer occurring.
AMBER there is a test in progress.
Blinking AMBER no DS0s have been assigned to the interface.
TD
GREEN the module is transmitting data to the network interface.
RD
GREEN the module is receiving data from the network and transmitting it out the V.35 interface (to the DTE equipment).
Interface Pinouts Table 34 provides the interface pinout for the DB-26 and V.35 interfaces. Table 34. Dual V.35 Interface Pinout (DB-26 to V.35)
50
Pin (DB-26)
Pin (V.35)
Description
1
A
Frame ground
2,3
–
Unused
4
C
Request to send (RTS)
5
D
Clear to send (CTS)
6
E
Data set ready (DSR)
7
B
Signal ground
8
F
Carrier detect (CD)
9
P
Transmitted data (TD-A) from DTE
10
S
Transmitted data (TD-B) to DTE
11
R
Received data (RD-A) to DTE
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 51
Total Access 850 System Manual
Section 2 Engineering Guidelines
Table 34. Dual V.35 Interface Pinout (DB-26 to V.35) (Continued) 12
T
Received data (RD-B) to DTE
13
U
External TX clock (ETC-A) from DTE
14-16
–
Unused
17
J
Ring indicator (RI)
18
L
LL
19
NN
Test mode (TM) to DTE
20
H
Data terminal ready (DTR) from DTE
21
–
Unused
22
Y
TX clock (TC-A) to DTE
23
AA
TX clock (TC-B) to DTE
24
V
RX clock (RC-A) to DTE
25
X
RX clock (RC-B) to DTE
26
W
External TX clock (ETC-B) from DTE
Specifications Table 35 provides the detailed specifications for the Total Access 850 Dual V.35 Module. Table 35. Dual V.35 Module Specifications
64203376L1-1B
Data Rates
56 kbps to 1.536 Mbps (per interface)
Relative Humidity
Up to 95% noncondensing
Cable Assembly
DB-26 to V.35 P/N 1200167L1
Temperature
Operate at -40 °C to +65 °C Store at -40 °C to +85 °C
Tests
Self-test, DTE loopback, Network Loopback, 511 Pattern generation
Electrical
Voltage
Current
-42 to -56 VDC +3.3 VDC ± 10% +5.0 VDC ± 5% -7.5 VDC ± 10% -24 to -30 VDC
0 mA 20 mA 160 mA 50 mA 0 mA
Dimensions
3 3/16” W x 1 5/16” H x 10 1/8” D
Weight
4.8 ounces
© 2004 ADTRAN, Inc.
51
Page 52
Section 2 Engineering Guidelines
Total Access 850 System Manual
Compliance Codes Table 36 provides the compliance codes for the Total Access 850 Dual V.35 Module. Table 36. Dual V.35 Module Compliance Codes CODE
IN
OUT
Power Code (PC)
C
C
Telecommunication Code (TC)
–
–
Installation Code
A
–
DSX-1 Access Module (P/N 1200385L1) The DSX-1 interface provided on the DSX-1 Access Module may be used for intra-building networks only. This interface should not be connected to public networks.
The DSX-1 Module is a single port (RJ-45) access module that provides a DSX-1 connection for customer premises equipment. This module supports PBXs or other equipment with a DSX-1/FT1 interface. This module is currently supported by the T1 RCU only. Robbed-Bit Signaling is only passed to the DSX-1 Module from the 3rd Generation RCUs. Older RCUs do not have this capability.
Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 37 on page 53 gives a description of all faceplate LEDs for the DSX-1 Module when used with the Total Access 850 system.
52
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 53
Total Access 850 System Manual
Section 2 Engineering Guidelines
Table 37. DSX-1 Module Faceplate LEDs For these LEDs...
This color light...
Indicates that...
Online
OFF there is no power to the system.
GREEN the DSX-1 signal is present and synchronized; the channel is configured for use.
RED there is a present channel alarm on the T1 interface.
Solid AMBER there is a channel test in progress.
Blinking AMBER the card is initializing (during startup).
Interface Pinout Table 38 provides the interface pinout for the provided RJ-45 DSX-1 interface. Table 38. DSX-1 Module Interface Pinout Pin
Name
Description
1
R1 | RXDATA-RING Receive data from the network (RING)
2
T1 | RXDATA-TIP
Receive data from the network (TIP)
3
UNUSED, 4
R | TXDATA-RING
Transmit data towards the network (RING)
5
T | TXDATA-TIP
Transmit data towards the network (TIP)
UNUSED, 6,7,8
Specifications Table 39 provides the detailed specifications for the Total Access 850 DSX-1 Module. Table 39. DSX-1 Module Specifications
64203376L1-1B
Capacity
T1: 1 to 24 DS0s
Framing
ESF and SF(D4)
Line Build Out
DSX-1: 0 to 655 feet in 133-foot increments
Line Coding
AMI (alternate mark inversion) or B8ZS (bipolar 8 zero substitution)
Line Rate
1.544 Mbps, + 75 bps
Relative Humidity
Up to 95% noncondensing
Terminating Impedance
100 ohms + 5%
Temperature
Operate at -0 °C to +50 °C Store at -40 °C to +70 °C
Tests
Self-test, local line, local payload, remote line, and remote payload
© 2004 ADTRAN, Inc.
53
Page 54
Section 2 Engineering Guidelines
54
Total Access 850 System Manual
© 2004 ADTRAN, Inc.
64203376L1-1B