Page 39

Total Access 850 System Manual

Section 2 Engineering Guidelines

T1 Wire-Wrap Connection (P3) Network T1 connections can have up to 140 VDC. Use caution when making T1 connections.

There are two termination points for connecting the network T1 to the chassis: the primary RJ-48 connector (JP2) and the alternate wire-wrap pins on terminal strip P3 (see Figure 6 on page 33). Only one connector type is used (not both). The T1 primary connection is via the RJ-48 connector labeled T1 (JP2). This arrangement provides a convenient T1 connection for those installations where a T1 Smart Jack is used. Table 18 on page 39 shows the pinout for the T1 wire-wrap connector. The Total Access 850 provides dual T1 connection points. In all cases, only one of the connection points is used. When wire-wrapping of the T1 is utilized (using P3), a blank plug must be placed in the primary T1 connection (JP2). There is a potential of Class A3 T1 Span Power Voltage coming from the network. Table 18. T1 Wire-Wrap Connector Pinout P3 Wire-Wrap Connections Pin

Name

Description

1

R1

DS1 Ring input from network

2

T1

DS1 Tip input from network

3

R

DS1 Ring output from network

4

T

DS1 Tip output from network

5

Gnd

Ground

Power Connections (P6 and P7) There are two power connections on the backplane: a modular DC plug (P6), and a three-lug terminal strip (P7) (refer to Figure 8 on page 40). The primary connection is the modular plug, which receives -48 VDC from an approved ADTRAN power supply/battery charging unit (for example, P/N 1175043L2). The alternate connection is screw terminal P7, which can be used if -48 VDC is available as in central office applications. The screw terminal connection is shown in Figure 8 on page 40. During installation, power should be the last connection made after all other wire-wrap connections are completed.

64203376L1-1B

© 2004 ADTRAN, Inc.

39

Page 40

Section 2 Engineering Guidelines

Total Access 850 System Manual

20 AWG RING LUG

16 AWG RING LUG

RED 16 AWG STRANDED

BLK

-48V

GRD

BLK 20 AWG SOLID

TO FUSE PANEL

FG TO WIRE WRAP FRAME GROUND

Figure 8. Alternate Power Connection

5.

ACCESS MODULE INTERFACES

Power Supply Unit (P/N 1175006L2) The PSU receives externally supplied -48 VDC from connectors P4 (normal) and P5 (alternate) on the rear of the unit. Connector P4 connects from an approved ADTRAN Power Supply and Battery Charger unit. P5 is a 3-lug terminal strip that receives -48 VDC from the customer-supplied office power. Through switchmode operation, the PSU converts the incoming -48 VDC to regulated +5 VDC, +3.3 VDC, -7.5 VDC, -26 VDC, and -48 VDC for distribution to other modules. Ring voltage circuitry within the PSU generates 105 Vrms, 20 Hz ring voltage for distribution to the system’s FXS cards. Ring voltage is disabled by pushing the RING ENABLE button.

Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 20 gives a description of all faceplate LEDs for the Quad FXS Module when used with the Total Access 850 system.

40

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 41

Total Access 850 System Manual

Section 2 Engineering Guidelines

Table 19. PSU Faceplate LEDs For these LEDs...

This color light...

Indicates that...

POWER

OFF the system is disconnected from the power source or powered off.

GREEN the system is connected to a power source and is powered on.

OFF ring generation is disabled for the system.

GREEN ring generation is enabled for the system.

OFF the system is in normal operation.

Solid RED there is currently an active alarm condition.

Blinking RED there was an alarm condition, but it was acknowledged by pressing the ACO pushbutton (located on the PSU faceplate).

RING

BANK ALM

Quad FXS Access Module (P/N 1175408L2) The Quad FXS Access Modules use the 50-pin female amphenol connector on the rear of the Total Access 850 chassis to provide the interconnect wiring for the four analog circuits on each access module.

Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 20 gives a description of all faceplate LEDs for the Quad FXS Module when used with the Total Access 850 system. Table 20. Quad FXS Module Faceplate LEDs For these LEDs...

This color light...

Indicates that...

BUSY

OFF the interface is currently on-hook and not in use.

Solid GREEN the interface is currently off-hook (busy).

Blinking GREEN the interface is ringing.

Sequencing 1-4 the assigned network T1 time slot is unavailable for use by the module.

64203376L1-1B

© 2004 ADTRAN, Inc.

41

Page 42

Section 2 Engineering Guidelines

Total Access 850 System Manual

Interface Pinout Figure 9 shows the pinout connection for the amphenol connector. See Figure 7 on page 38 for closer detail. 25 50 24 49 23 48 22 47 21 46 20 45 19 44 18 43 17 42 16 41 15 40 14 39 13 38 12 37 11 36 10 35 9

34

8

33

7

32

6

31

5

30

4

29

3

28

2

27

1

26

P P P

Slot 6

P P P P

Slot 5

P P P P

Slot 4

P P P P

Slot 3

P P P P

Slot 2

P P P P P

Slot 1

NC T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R

Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1

50 PIN AMP RECEPTACLE

Figure 9. Quad FXS Connector Pin Assignments

Specifications Table 21 provides the detailed specifications for the Total Access 850 Quad FXS Module. Table 21. Quad FXS Module Specifications

42

Power

6 W (off-hook)

Loop Current

23 mA (nominal) 20 mA (minimum)

Loop Resistance

1200 Ω (nominal) 1650 Ω (maximum) – 900 Ω/1350 Ω (line), 300 Ω (phone)

Terminating Impedance

900 Ω + 2.16 µF 600 Ω + 2.16 µF 900 Ω 600 Ω

Return Loss

900 Ω + 2.16 µF ERL > 28 dB SRL > 20 dB

Trans Hybrid Loss

900 Ω + 2.16 µF ERL > 28 dB SRL > 20 dB

Longitudinal Balance

200, 500, and 1000 Hz: > 58 dB min, > 63 dB avg 3000 Hz: > 53 dB min, > 58 dB avg

Frequency Response

300 to 3400 Hz: -0.5 dB and 1.0 dB

Idle Channel Noise

< 20 dBrnC

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 43

Total Access 850 System Manual

Section 2 Engineering Guidelines

Table 21. Quad FXS Module Specifications (Continued) Signal to Distortion Ratio

0 to -30 dBm0: > 33 dB -30 to -40 dBm0: > 27 dB -40 to -45 dBm0: > 22 dB

Relative Humidity

Up to 95% noncondensing

Temperature

Operate at -40 °C to +65 °C Store at -40 °C to +70 °C

Tests

Self-test, digital loopback, network on-hook/off-hook, customer ring, and 1000 Hz (1 kHz) tone generation

Compliance Codes Table 22 provides the compliance codes for the Total Access 850 Quad FXS Module. Table 22. Quad FXS Module Compliance Codes CODE

IN

OUT

Power Code (PC)

C

C

Telecommunication Code (TC)

–

X

Installation Code

A

–

Quad FXO Access Module (P/N 1175407L1) The Quad FXO Access Modules use the 50-pin female amphenol connector on the rear of the Total Access 850 chassis to provide the interconnect wiring for the four analog circuits on each access module.

Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 23 gives a description of all faceplate LEDs for the Quad FXO Module when used with the Total Access 850 system. Table 23. Quad FXO Module Faceplate LEDs For these LEDs...

This color light...

Indicates that...

BUSY

OFF the interface is currently on-hook and not in use.

GREEN the interface is currently off-hook (busy).

Blinking GREEN the interface is ringing.

Sequencing 1-4 the assigned network T1 time slot is unavailable for use by the module.

64203376L1-1B

© 2004 ADTRAN, Inc.

43

Page 44

Section 2 Engineering Guidelines

Total Access 850 System Manual

Interface Pinout Figure 10 shows the pinout connection for the amphenol connector. See Figure 7 on page 38 for closer detail. 25 50 24 49 23 48 22 47 21 46 20 45 19 44 18 43 17 42 16 41 15 40 14 39 13 38 12 37 11 36 10 35 9

34

8

33

7

32

6

31

5

30

4

29

3

28

2

27

1

26

P P P

Slot 6

P P P P

Slot 5

P P P P

Slot 4

P P P P

Slot 3

P P P P

Slot 2

P P P P

Slot 1

P

NC T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R

Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1

50 PIN AMP RECEPTACLE

Figure 10. Quad FXO Connector Pin Assignments

Specifications Table 24 provides the detailed specifications for the Total Access 850 Quad FXO Module. Table 24. Quad FXO Module Specifications

44

Power

2 W (off-hook)

Terminating Impedance

900 Ω + 2.16 µF

Return Loss

900 Ω + 2.16 µF ERL > 28 dB SRL > 20 dB

Trans Hybrid Loss

900 Ω + 2.16 µF ERL > 28 dB SRL > 20 dB

Longitudinal Balance

200, 500, and 1000 Hz: > 58 dB min, > 63 dB avg 3000 Hz: > 53 dB min, > 58 dB avg

Frequency Response

300 to 3400 Hz: -0.5 dB and 1.0 dB

Idle Channel Noise

< 20 dBrnC

Signal to Distortion Ratio

0 to -30 dBm0: > 33 dB -30 to -40 dBm0: > 27 dB -40 to -45 dBm0: > 22 dB

Relative Humidity

Up to 95% noncondensing

Temperature

Operate at -40 °C to +65 °C Store at -40 °C to +70 °C

Tests

Self-test, digital loopback, network on-hook/off-hook, customer ring, and 100 Hz tone generation

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 45

Total Access 850 System Manual

Section 2 Engineering Guidelines

Compliance Codes Table 25 provides the compliance codes for the Total Access 850 Quad FXO Module. Table 25. Quad FXO Module Compliance Codes CODE

IN

OUT

Power Code (PC)

C

C

Telecommunication Code (TC)

–

X

Installation Code

A

–

UBR1TE Access Module (P/N 1180020L1) Each port of the UBR1TE Access Module provides an ISDN U-interface and allows the transport of Basic Rate 2B+D information over the T1 carrier and twisted pair wiring.

Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 26 gives a description of all faceplate LEDs for the UBR1TE Module when used with the Total Access 850 system. Table 26. UBR1TE Module Faceplate LEDs For these LEDs...

This color light...

Indicates that...

STATUS

OFF both the loop and the carrier synchronization are established.

Solid RED neither the loop nor the carrier synchronization is established.

Blinking RED (every two seconds)

loop synchronization is established, but carrier synchronization is not.

Blinking RED (twice every second)

carrier synchronization is established, but loop synchronization is not.

GREEN

Layer 1 is established from the ISDN switch to the customer ISDN terminal equipment.

Solid AMBER front panel test in progress or the unit is responding to a 2B + D loopback request.

Blinking AMBER (every two seconds)

the unit is responding to a B1 loopback request or has been forced into a B1 loopback from the terminal menus.

Blinking AMBER the unit is responding to a B2 loopback request or has (twice every second) been forced into a B2 loopback from the terminal menus. REM (Remote)

64203376L1-1B

GREEN the unit has been provisioned by the BCU/RCU.

OFF the unit is provisioned by DIP-switches.

© 2004 ADTRAN, Inc.

45

Page 46

Section 2 Engineering Guidelines

Total Access 850 System Manual

Interface Pinout Table 27 provides the interface pinout for the UBR1TE interface slot/amphenol connector assignment. Table 27. UBR1TE Slot/Amphenol Assignment Total Access 850 Slot

Port 1 T/R

1

26/1

2

30/5

3

34/9

4

38/13

5

42/17

6

46/21

DIP-Switch Settings The Total Access 850 UBR1TE Module can be provisioned from either the DIP-switches (S1) mounted on the PCB, or through screen menus accessed via the faceplate CRAFT interface port. Table 28 provides the DIP-switch setting details. Table 28. BCU DIP-Switch S1 Options

46

Switch

Function

Description

S1-1

MODE

Sets the termination mode as LULT (RT Typical) or LUNT (COT Typical). ON

Unit is installed as Adjacent-to-U-Repeater, Adjacent-to-Customer, or Tandem Office Source configuration.

OFF

Unit is installed as Adjacent-to-Switch or Tandem Office Sink configuration.

© 2004 ADTRAN, Inc.

64203376L1-1B