Page 31

Total Access 850 System Manual

Section 2 Engineering Guidelines

Table 6. 3rd GEN T1 RCU Faceplate LEDs For these LEDs...

This color light...

Indicates that...

T1

GREEN the network T1 interface is operational.

RED the network T1 is in Red Alarm (meaning the T1 is down, not connected, or framing is improperly configured).

AMBER the network T1 is in test mode (loopback).

GREEN there is a valid 10 Mbps Ethernet link.

AMBER there is a valid 100 Mbps Ethernet link.

RED there is no active Ethernet link.

ETH

Faceplate Bantam Jack The faceplate bantam jack provides a means to monitor the network T1 connected to the rear of the Total Access 850 chassis. The jacks accept standard 310-type bantam plugs. Figure 5 display the bantam jack monitoring points. Receiver Circuitry T1 T1 RX PAIR R1

Clock and Data Recovery

Line Format Decoder

To Backplane

DJAT

Line Format Encoder

From Backplane

MON IN Test Jack

T1 T TX PAIR R

Equalizer

Transmitter Circuitry MON OUT Test Jack

Local Loopback Point

Line Loopback Point

Payload/CSU Loopback Point

Figure 5. 3rd GEN RCU Bantam Jack Test Diagram

64203376L1-1B

© 2004 ADTRAN, Inc.

31

Page 32

Section 2 Engineering Guidelines

Total Access 850 System Manual

SDSL Router Controller Unit (1200377L1 and 1200377L2) The following is operational information pertaining to the SDSL Router Controller Unit when used with the Total Access 850 system.

Faceplate CRAFT Interface Use the CRAFT port on the RCU faceplate to configure the system via an EIA-232 connection. Table 7 displays the CRAFT port pinout. Table 7. SDSL RCU CRAFT (DB-9, Female) Pinout Pin

Name

1, 4, 6-9

UNUSED, Description

2

RD

Receive Data (Output)

3

TD

Transmit Data (Input)

5

SG

Signal Ground

Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 8 gives a description of all faceplate LEDs for the SDSL RCU when used with the Total Access 850 system. Table 8. SDSL RCU Faceplate LEDs For these LEDs...

This color light...

Indicates that...

PWR

OFF there is no power to the system.

Solid GREEN the system is connected to an active power source.

DATA

Blinking GREEN there is transmit data detected on the network interface

NET ALRM

OFF there are no active network alarms on the system.

ON there is an active network alarm on the system.

TEST

AMBER the network interface is in test mode (loopback).

V.35 TD

Blinking GREEN there is transmit data detected on the V.35 port. This LED blinks with data traffic.

V.35 RD

Blinking GREEN there is received data detected on the V.35 port. This LED blinks with data traffic.

ETH LI

OFF there is no active Ethernet link.

Solid GREEN there is a valid Ethernet link on the 10BaseT interface.

Blinking GREEN there is received or transmitted data detected on the Ethernet interface. This LED blinks with data traffic.

ETH TX/RX

32

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 33

Total Access 850 System Manual

Section 2 Engineering Guidelines

DIP-Switch Settings The Total Access 850 SDSL RCU uses DIP-switches to determine power-up start mode. Table 9 provides details for the DIP-switches. Table 9. SDSL RCU DIP-Switch S1 Options Switch

Function

Description

S1-1

Firmware Mode

ON* (down)

The unit powers up in the firmware update mode. This mode is not used for normal operation.

OFF

Disables the firmware update mode.

ON* (down)

The unit powers up with the factory defaults loaded.

S1-2

Factory Defaults

* Denotes factory default settings.

4.

REVIEWING THE REAR PANEL DESIGN

All connections are made through terminals, jacks, and wire-wraps on the backplane. A removable rear cover provides access to the backplane, and an access panel that mounts to the rear cover allows access to wire-wrap strips P1, P3, and P5, power terminal strip (P7), and clock termination switch (SW1) without removing the main rear cover. Most CPE applications will not require removal of the rear cover. Before removing the rear cover, do the following: For systems using PSU (P/N 1175006L1) – Remove the 20 Hz fuse before exposing backplane or accessing channel unit. For systems using PSU (P/N 1175006L2) – Depress the Ring Enable pushbutton to isolate the ring voltage from the Total Access 850. Figure 6 shows the Total Access 850 backplane, and Table 10 on page 34 gives the backplane connections.

P5

P7

P6

Figure 6. Total Access 850 Rear Panel

64203376L1-1B

© 2004 ADTRAN, Inc.

33

Page 34

Section 2 Engineering Guidelines

Total Access 850 System Manual

Table 10. Total Access 850 Backplane Connections Ref Des

Device/Label

Technology

P1 wire-wrap strip clock/tests

P2

50 pin amphenol

FXO, FXS, etc.

P3 wire-wrap strip alternate T1 interface

P5 wire-wrap strip alarms

P6

4 pin jack primary -48 V in

P7

3-lug terminal alternate -48 V in

JP1

RJ-48/E-NET

10BaseT Ethernet

JP2

RJ-48/T1 primary T1 interface

JP3

RJ-48/FT1

DSX1 interface

JP4

RJ-48/MAINT

EIA-232 CRAFT interface

J1

V.35

Nx56K/64K

10/100BaseT Connection (JP1) Only the 3rd Generation RCUs provide a 10/100BaseT connection. All other available RCU Ethernet interfaces are 10BaseT.

The 10/100BaseT port (RJ-48C) provides a 10/100BaseT Ethernet LAN connection for IP Routing, TFTP, SNMP, and Telnet connections. Table 11 shows the 10/100BaseT pinout. The 10/100BaseT Ethernet LAN interface may be used for intra-building networks only. This interface should not be connected to public networks. Table 11. Ethernet Pinout Pin

34

Name

Description

1

TX1

Transmit Positive

2

TX2

Transmit Negative

3

RX1

Receive Positive

4, 5

UNUSED, 6

RX2

Receive Negative

7, 8

UNUSED, © 2004 ADTRAN, Inc.

64203376L1-1B

Page 35

Total Access 850 System Manual

Section 2 Engineering Guidelines

T1 Connection (JP2) The Total Access 850 provides dual T1 connection points. In all cases, only one of the connection points is used. When wire-wrapping of the T1 is utilized (using P3), a blank plug must be placed in the primary T1 connection (JP2). There is a potential of Class A3 T1 Span Power Voltage coming from the network. The Total Access 850 system provides a single T1 port (located on the rear panel) and complies with the applicable ANSI and AT&T™ standards. The T1 interface provides the following functions: • AMI or B8ZS • Manual line build-out • D4 or ESF framing • Network performance monitoring and reporting • Test loopbacks with QRSS generation checking • Extensive self-testing The T1 connection pinout is shown in Table 12. Table 12. Network Connection Pinout Pin

Name

Description

1

RXDATA-RING

Receive data from the network

2

RXDATA-TIP

Receive data from the network

3

UNUSED, 4

TXDATA-RING

Transmit data toward the network

5

TXDATA-TIP

Transmit data toward the network

6, 7, 8

UNUSED, DSX-1 Connection (JP3) The Total Access 850 system provides a single DSX-1 port (located in the rear of the unit). The DSX-1 interface provides the following functions: • AMI or B8ZS • Manual line build-out • D4 or ESF framing

64203376L1-1B

© 2004 ADTRAN, Inc.

35

Page 36

Section 2 Engineering Guidelines

Total Access 850 System Manual

The DSX-1 interface pinout is shown in Table 13. Table 13. DSX-1 Network Connection Pinout Pin

Name

Description

1

R

TXDATA-RING

Transmit data from the network.

2

T

TXDATA-TIP

Transmit data from the network.

3, UNUSED, 4

R1

RXDATA-RING

Receive data toward the network.

5

T1

RXDATA-TIP

Receive data toward the network.

6, 7, 8, UNUSED, Rear CRAFT Port (JP4) The CRAFT port (EIA-232) on the rear of the chassis connects to a computer or modem and provides the following functions: • Accepts EIA-232 input from a PC or a modem for controlling the Total Access 850. • Baud rate is user-configurable. • Acts as input for either VT100 or PC control. • Acts as an interface for flash memory software downloads using XMODEM. Table 14 shows the rear CRAFT port pinout. Table 14. Rear CRAFT Pinout Pin

36

Name

Description

1

GND

Ground - connected to unit chassis

2

RTS

Request to send - flow control

3

RXDATA

Data received by the Total Access 850

4

DTR

Data terminal ready

5

TXDATA

Data transmitted by the Total Access 850

6

CD

Carrier detect

7

UNUSED, 8

CTS

Clear to send - flow control

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 37

Total Access 850 System Manual

Section 2 Engineering Guidelines

Nx56k/64k Port (J1) The Total Access 850 system provides a single V.35 Winchester-style connection on the rear of the chassis (as defined in Table 15). Table 15. V.35 Winchester Pinout Pin/CCIT

Description

Pin/CCIT

Description

A/101

Protective ground (PG)

V/115

RX clock (RC-A) to DTE

B/102

Signal ground (SG)

X/115

RX clock (RC-B) to DTE

C/105

Request to send (RTS) from DTE

P/103

Transmitted data (TD-A) from DTE

D/106

Clear to send (CTS) to DTE

S/103

Transmitted data (TD-B) to DTE

E/107

Data set ready (DSR) to DTE

Y/114

TX clock (TC-A) to DTE

E/109

Data carrier detect

AA/114

TX clock (TC-B) to DTE

H/ - Data terminal ready (DTR) from DTE

U/113

External TX clock (ETC-A) from DTE

J/ - Ring indicator (RI)

W/113

External TX clock (ETC-B) from DTE

R/104

Received data (RD-A) to DTE

NN/ - Test mode (TM) to DTE

T/104

Received data (RD-B) to DTE

Alarm Relay Connection (P5) This connection alerts the user when a selected alarm condition exists. Alarm relay contacts are open during normal operation. The alarm relay contacts close in the event of a local alarm condition or the receipt of an alarm from the T1 carrier. In a carrier alarm condition such as a Red, Yellow, or Blue (unframed all 1s), various alarm contacts in the PSU close. Carrier alarm conditions cause the Total Access 850 to initiate trunk processing. The following chain of events then occur: 1. MJ will be directly shorted to MJR. 2. MJV will be directly shorted to MJVR.

Contacts MJ and MJR can be overridden manually during an alarm condition by pressing the ACO pushbutton on the PSU faceplate. If the 3-Amp power fuse on the PSU trips, the -48ALM relay will close, providing a -48 VDC signal on that pin. This alarm cannot be overridden by the ACO pushbutton. Refer to Table 17 for alarm notifications. Table 16 shows the pinout for the Alarm Relay connector. Table 16. Alarm Relay Connector Pinout Pin

Name

1

-48 ALM

DC alarm output.

2

MJVR

Closes when a selected alarm condition is present.

3

MJV

Common connection between external circuitry and NC or NO terminal.

4

MJR

Major alarm audible common

5

MJ

Major alarm audible

64203376L1-1B

Description

© 2004 ADTRAN, Inc.

37

Page 38

Section 2 Engineering Guidelines

Total Access 850 System Manual Table 17. Alarm Notification

Alarm Condition

Relays Activated MJR

MJVR

Red Alarm

X

X

Yellow Alarm

X

X

AIS Alarm

X

X

PSU Power Fuse Fails

X

X

Alarms ACO Deactivates

X

X

-48 ALM

X

Note: ACO will not deactivate MJR after a power fuse failure.

Clock Wire-Wrap Strip (P1) A single wire-wrap strip is provided on the Total Access 850 backplane for connection to an external bits clock. The external bits clock may be used to provide master timing for the Total Access 850 system.

Customer Connection (P2) One 50-pin female amphenol connector (P2) provides the interconnect wiring for the access modules located in slots 1 through 6 of the chassis. This connector is usually terminated with a punch-down block for premises wiring or connected directly to a cross-connect or main distribution frame. Figure 7 details the connector pinout. N C

25

50

24

49

23

48

22

47

21

46

20

45

19

44

18

43

17

42

16

41

15

40

14

39

13

38

12

37

11

36

10

35

9

34

8

33

7

32

6

31

5

30

4

29

3

28

2

27

1

26

P P P

Slot 6

P P P P

Slot 5

P P P P

Slot 4

P P P P

Slot 3

P P P P

Slot 2

P P P P P

Slot 1

NC T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R

Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1

50 PIN AMP RECEPTACLE

Figure 7. Connector Pinout

38

© 2004 ADTRAN, Inc.

64203376L1-1B