The text of a manual · part 4 of 30
Total Access 850 System Manual: Engineering Guidelines, pages 31 to 38
Pages 31 to 38 of 292, from Total Access 850 System Manual
The original document is the PDF (3.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Adtran 1200375L1
Page 31
Total Access 850 System Manual
Section 2 Engineering Guidelines
Table 6. 3rd GEN T1 RCU Faceplate LEDs For these LEDs...
This color light...
Indicates that...
T1
GREEN the network T1 interface is operational.
RED the network T1 is in Red Alarm (meaning the T1 is down, not connected, or framing is improperly configured).
AMBER the network T1 is in test mode (loopback).
GREEN there is a valid 10 Mbps Ethernet link.
AMBER there is a valid 100 Mbps Ethernet link.
RED there is no active Ethernet link.
ETH
Faceplate Bantam Jack The faceplate bantam jack provides a means to monitor the network T1 connected to the rear of the Total Access 850 chassis. The jacks accept standard 310-type bantam plugs. Figure 5 display the bantam jack monitoring points. Receiver Circuitry T1 T1 RX PAIR R1
Clock and Data Recovery
Line Format Decoder
To Backplane
DJAT
Line Format Encoder
From Backplane
MON IN Test Jack
T1 T TX PAIR R
Equalizer
Transmitter Circuitry MON OUT Test Jack
Local Loopback Point
Line Loopback Point
Payload/CSU Loopback Point
Figure 5. 3rd GEN RCU Bantam Jack Test Diagram
64203376L1-1B
© 2004 ADTRAN, Inc.
31
Page 32
Section 2 Engineering Guidelines
Total Access 850 System Manual
SDSL Router Controller Unit (1200377L1 and 1200377L2) The following is operational information pertaining to the SDSL Router Controller Unit when used with the Total Access 850 system.
Faceplate CRAFT Interface Use the CRAFT port on the RCU faceplate to configure the system via an EIA-232 connection. Table 7 displays the CRAFT port pinout. Table 7. SDSL RCU CRAFT (DB-9, Female) Pinout Pin
Name
1, 4, 6-9
UNUSED, Description
2
RD
Receive Data (Output)
3
TD
Transmit Data (Input)
5
SG
Signal Ground
Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 8 gives a description of all faceplate LEDs for the SDSL RCU when used with the Total Access 850 system. Table 8. SDSL RCU Faceplate LEDs For these LEDs...
This color light...
Indicates that...
PWR
OFF there is no power to the system.
Solid GREEN the system is connected to an active power source.
DATA
Blinking GREEN there is transmit data detected on the network interface
NET ALRM
OFF there are no active network alarms on the system.
ON there is an active network alarm on the system.
TEST
AMBER the network interface is in test mode (loopback).
V.35 TD
Blinking GREEN there is transmit data detected on the V.35 port. This LED blinks with data traffic.
V.35 RD
Blinking GREEN there is received data detected on the V.35 port. This LED blinks with data traffic.
ETH LI
OFF there is no active Ethernet link.
Solid GREEN there is a valid Ethernet link on the 10BaseT interface.
Blinking GREEN there is received or transmitted data detected on the Ethernet interface. This LED blinks with data traffic.
ETH TX/RX
32
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 33
Total Access 850 System Manual
Section 2 Engineering Guidelines
DIP-Switch Settings The Total Access 850 SDSL RCU uses DIP-switches to determine power-up start mode. Table 9 provides details for the DIP-switches. Table 9. SDSL RCU DIP-Switch S1 Options Switch
Function
Description
S1-1
Firmware Mode
ON* (down)
The unit powers up in the firmware update mode. This mode is not used for normal operation.
OFF
Disables the firmware update mode.
ON* (down)
The unit powers up with the factory defaults loaded.
S1-2
Factory Defaults
* Denotes factory default settings.
4.
REVIEWING THE REAR PANEL DESIGN
All connections are made through terminals, jacks, and wire-wraps on the backplane. A removable rear cover provides access to the backplane, and an access panel that mounts to the rear cover allows access to wire-wrap strips P1, P3, and P5, power terminal strip (P7), and clock termination switch (SW1) without removing the main rear cover. Most CPE applications will not require removal of the rear cover. Before removing the rear cover, do the following: For systems using PSU (P/N 1175006L1) – Remove the 20 Hz fuse before exposing backplane or accessing channel unit. For systems using PSU (P/N 1175006L2) – Depress the Ring Enable pushbutton to isolate the ring voltage from the Total Access 850. Figure 6 shows the Total Access 850 backplane, and Table 10 on page 34 gives the backplane connections.
P5
P7
P6
Figure 6. Total Access 850 Rear Panel
64203376L1-1B
© 2004 ADTRAN, Inc.
33
Page 34
Section 2 Engineering Guidelines
Total Access 850 System Manual
Table 10. Total Access 850 Backplane Connections Ref Des
Device/Label
Technology
P1 wire-wrap strip clock/tests
P2
50 pin amphenol
FXO, FXS, etc.
P3 wire-wrap strip alternate T1 interface
P5 wire-wrap strip alarms
P6
4 pin jack primary -48 V in
P7
3-lug terminal alternate -48 V in
JP1
RJ-48/E-NET
10BaseT Ethernet
JP2
RJ-48/T1 primary T1 interface
JP3
RJ-48/FT1
DSX1 interface
JP4
RJ-48/MAINT
EIA-232 CRAFT interface
J1
V.35
Nx56K/64K
10/100BaseT Connection (JP1) Only the 3rd Generation RCUs provide a 10/100BaseT connection. All other available RCU Ethernet interfaces are 10BaseT.
The 10/100BaseT port (RJ-48C) provides a 10/100BaseT Ethernet LAN connection for IP Routing, TFTP, SNMP, and Telnet connections. Table 11 shows the 10/100BaseT pinout. The 10/100BaseT Ethernet LAN interface may be used for intra-building networks only. This interface should not be connected to public networks. Table 11. Ethernet Pinout Pin
34
Name
Description
1
TX1
Transmit Positive
2
TX2
Transmit Negative
3
RX1
Receive Positive
4, 5
UNUSED, 6
RX2
Receive Negative
7, 8
UNUSED, © 2004 ADTRAN, Inc.
64203376L1-1B
Page 35
Total Access 850 System Manual
Section 2 Engineering Guidelines
T1 Connection (JP2) The Total Access 850 provides dual T1 connection points. In all cases, only one of the connection points is used. When wire-wrapping of the T1 is utilized (using P3), a blank plug must be placed in the primary T1 connection (JP2). There is a potential of Class A3 T1 Span Power Voltage coming from the network. The Total Access 850 system provides a single T1 port (located on the rear panel) and complies with the applicable ANSI and AT&T™ standards. The T1 interface provides the following functions: • AMI or B8ZS • Manual line build-out • D4 or ESF framing • Network performance monitoring and reporting • Test loopbacks with QRSS generation checking • Extensive self-testing The T1 connection pinout is shown in Table 12. Table 12. Network Connection Pinout Pin
Name
Description
1
RXDATA-RING
Receive data from the network
2
RXDATA-TIP
Receive data from the network
3
UNUSED, 4
TXDATA-RING
Transmit data toward the network
5
TXDATA-TIP
Transmit data toward the network
6, 7, 8
UNUSED, DSX-1 Connection (JP3) The Total Access 850 system provides a single DSX-1 port (located in the rear of the unit). The DSX-1 interface provides the following functions: • AMI or B8ZS • Manual line build-out • D4 or ESF framing
64203376L1-1B
© 2004 ADTRAN, Inc.
35
Page 36
Section 2 Engineering Guidelines
Total Access 850 System Manual
The DSX-1 interface pinout is shown in Table 13. Table 13. DSX-1 Network Connection Pinout Pin
Name
Description
1
R
TXDATA-RING
Transmit data from the network.
2
T
TXDATA-TIP
Transmit data from the network.
3, UNUSED, 4
R1
RXDATA-RING
Receive data toward the network.
5
T1
RXDATA-TIP
Receive data toward the network.
6, 7, 8, UNUSED, Rear CRAFT Port (JP4) The CRAFT port (EIA-232) on the rear of the chassis connects to a computer or modem and provides the following functions: • Accepts EIA-232 input from a PC or a modem for controlling the Total Access 850. • Baud rate is user-configurable. • Acts as input for either VT100 or PC control. • Acts as an interface for flash memory software downloads using XMODEM. Table 14 shows the rear CRAFT port pinout. Table 14. Rear CRAFT Pinout Pin
36
Name
Description
1
GND
Ground - connected to unit chassis
2
RTS
Request to send - flow control
3
RXDATA
Data received by the Total Access 850
4
DTR
Data terminal ready
5
TXDATA
Data transmitted by the Total Access 850
6
CD
Carrier detect
7
UNUSED, 8
CTS
Clear to send - flow control
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 37
Total Access 850 System Manual
Section 2 Engineering Guidelines
Nx56k/64k Port (J1) The Total Access 850 system provides a single V.35 Winchester-style connection on the rear of the chassis (as defined in Table 15). Table 15. V.35 Winchester Pinout Pin/CCIT
Description
Pin/CCIT
Description
A/101
Protective ground (PG)
V/115
RX clock (RC-A) to DTE
B/102
Signal ground (SG)
X/115
RX clock (RC-B) to DTE
C/105
Request to send (RTS) from DTE
P/103
Transmitted data (TD-A) from DTE
D/106
Clear to send (CTS) to DTE
S/103
Transmitted data (TD-B) to DTE
E/107
Data set ready (DSR) to DTE
Y/114
TX clock (TC-A) to DTE
E/109
Data carrier detect
AA/114
TX clock (TC-B) to DTE
H/ - Data terminal ready (DTR) from DTE
U/113
External TX clock (ETC-A) from DTE
J/ - Ring indicator (RI)
W/113
External TX clock (ETC-B) from DTE
R/104
Received data (RD-A) to DTE
NN/ - Test mode (TM) to DTE
T/104
Received data (RD-B) to DTE
Alarm Relay Connection (P5) This connection alerts the user when a selected alarm condition exists. Alarm relay contacts are open during normal operation. The alarm relay contacts close in the event of a local alarm condition or the receipt of an alarm from the T1 carrier. In a carrier alarm condition such as a Red, Yellow, or Blue (unframed all 1s), various alarm contacts in the PSU close. Carrier alarm conditions cause the Total Access 850 to initiate trunk processing. The following chain of events then occur: 1. MJ will be directly shorted to MJR. 2. MJV will be directly shorted to MJVR.
Contacts MJ and MJR can be overridden manually during an alarm condition by pressing the ACO pushbutton on the PSU faceplate. If the 3-Amp power fuse on the PSU trips, the -48ALM relay will close, providing a -48 VDC signal on that pin. This alarm cannot be overridden by the ACO pushbutton. Refer to Table 17 for alarm notifications. Table 16 shows the pinout for the Alarm Relay connector. Table 16. Alarm Relay Connector Pinout Pin
Name
1
-48 ALM
DC alarm output.
2
MJVR
Closes when a selected alarm condition is present.
3
MJV
Common connection between external circuitry and NC or NO terminal.
4
MJR
Major alarm audible common
5
MJ
Major alarm audible
64203376L1-1B
Description
© 2004 ADTRAN, Inc.
37
Page 38
Section 2 Engineering Guidelines
Total Access 850 System Manual Table 17. Alarm Notification
Alarm Condition
Relays Activated MJR
MJVR
Red Alarm
X
X
Yellow Alarm
X
X
AIS Alarm
X
X
PSU Power Fuse Fails
X
X
Alarms ACO Deactivates
X
X
-48 ALM
X
Note: ACO will not deactivate MJR after a power fuse failure.
Clock Wire-Wrap Strip (P1) A single wire-wrap strip is provided on the Total Access 850 backplane for connection to an external bits clock. The external bits clock may be used to provide master timing for the Total Access 850 system.
Customer Connection (P2) One 50-pin female amphenol connector (P2) provides the interconnect wiring for the access modules located in slots 1 through 6 of the chassis. This connector is usually terminated with a punch-down block for premises wiring or connected directly to a cross-connect or main distribution frame. Figure 7 details the connector pinout. N C
25
50
24
49
23
48
22
47
21
46
20
45
19
44
18
43
17
42
16
41
15
40
14
39
13
38
12
37
11
36
10
35
9
34
8
33
7
32
6
31
5
30
4
29
3
28
2
27
1
26
P P P
Slot 6
P P P P
Slot 5
P P P P
Slot 4
P P P P
Slot 3
P P P P
Slot 2
P P P P P
Slot 1
NC T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R
Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1
50 PIN AMP RECEPTACLE
Figure 7. Connector Pinout
38
© 2004 ADTRAN, Inc.
64203376L1-1B