Page 23

ENGINEERING GUIDELINES This section provides equipment dimensions, power requirements, front panel design, rear panel design, LEDs, and at-a-glance specifications.

CONTENTS Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 AC System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 DC System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Reviewing the Front Panel Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Bank Controller Unit (1200373L1 and 1200373L2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 T1 Router Controller Unit (4200376L1#TDM and 4200376L1#ATM) . . . . . . . . . . . . . . . . . . . . . 28 3rd GEN T1 Router Controller Unit (1203376L1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 SDSL Router Controller Unit (1200377L1 and 1200377L2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Reviewing the Rear Panel Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 10/100BaseT Connection (JP1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 T1 Connection (JP2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 DSX-1 Connection (JP3). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Rear CRAFT Port (JP4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Nx56k/64k Port (J1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Alarm Relay Connection (P5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Clock Wire-Wrap Strip (P1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Customer Connection (P2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 T1 Wire-Wrap Connection (P3). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Power Connections (P6 and P7). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Access Module Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Power Supply Unit (P/N 1175006L2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Quad FXS Access Module (P/N 1175408L2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Quad FXO Access Module (P/N 1175407L1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 UBR1TE Access Module (P/N 1180020L1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 OCU DP Access Module (P/N 1180005L1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 E&M/TO Access Module (P/N 1180402L1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Dual V.35 Access Module (P/N 1180025L1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 DSX-1 Access Module (P/N 1200385L1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10.

FIGURES Total Access 850 Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BCU Bantam Jack Test Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BCU DB-9 Test Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RCU Bantam Jack Test Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3rd GEN RCU Bantam Jack Test Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Total Access 850 Rear Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connector Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alternate Power Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quad FXS Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quad FXO Connector Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 1. Table 2. Table 3.

TABLES BCU Faceplate LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 BCU DIP-Switch S1 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 T1 RCU CRAFT (DB-9, Female) Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

64203376L1-1B

© 2004 ADTRAN, Inc.

25 28 28 30 31 33 38 40 42 44

23

Page 24

Section 2 Engineering Guidelines

Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 11. Table 12. Table 13. Table 14. Table 15. Table 16. Table 17. Table 18. Table 19. Table 20. Table 21. Table 22. Table 23. Table 24. Table 25. Table 26. Table 27. Table 28. Table 29. Table 30. Table 31. Table 32. Table 33. Table 34. Table 35. Table 36. Table 37. Table 38. Table 39.

24

Total Access 850 System Manual

T1 RCU Faceplate LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 3rd GEN T1 RCU CRAFT (DB-9, Female) Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 3rd GEN T1 RCU Faceplate LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 SDSL RCU CRAFT (DB-9, Female) Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 SDSL RCU Faceplate LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 SDSL RCU DIP-Switch S1 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Total Access 850 Backplane Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Ethernet Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Network Connection Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 DSX-1 Network Connection Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Rear CRAFT Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 V.35 Winchester Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Alarm Relay Connector Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Alarm Notification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 T1 Wire-Wrap Connector Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 PSU Faceplate LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Quad FXS Module Faceplate LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Quad FXS Module Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Quad FXS Module Compliance Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Quad FXO Module Faceplate LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Quad FXO Module Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Quad FXO Module Compliance Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 UBR1TE Module Faceplate LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 UBR1TE Slot/Amphenol Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 BCU DIP-Switch S1 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 UBR1TE Module Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 UBR1TE Module Compliance Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 OCU DP Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 E&M/TO Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Dual V.35 Module Faceplate LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Dual V.35 Interface Pinout (DB-26 to V.35) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Dual V.35 Module Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Dual V.35 Module Compliance Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 DSX-1 Module Faceplate LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 DSX-1 Module Interface Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 DSX-1 Module Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 25

Total Access 850 System Manual

1.

Section 2 Engineering Guidelines

EQUIPMENT DIMENSIONS

The Total Access 850 chassis is 8.5” W, 11” D, and 3.5” H and can be mounted in a 19-inch or 23-inch rack (mounting brackets included in shipment). All other equipment (modules) fit inside the base unit.

2.

POWER REQUIREMENTS

Regardless of the configuration of access modules installed in the chassis, the following power requirements apply:

AC System 90/130 VAC, 60 Hz, 50 Watt Max

DC System 40/56 VDC, 50 Watt Max

3.

REVIEWING THE FRONT PANEL DESIGN

Figure 1 shows the Total Access 850 front panel. Refer to Access Module Interfaces on page 40 for a discussion of available modules and the front panel functions of each.

Figure 1. Total Access 850 Front Panel Layout

UL 60950/NEBS requires all Total Access 850 empty slots to be covered with blank panels (P/N 1175099L1).

64203376L1-1B

© 2004 ADTRAN, Inc.

25

Page 26

Section 2 Engineering Guidelines

Total Access 850 System Manual

Bank Controller Unit (1200373L1 and 1200373L2) The following is operational information pertaining to the Bank Controller Unit when used with the Total Access 850 system.

Faceplate LEDs The faceplate Network LEDs labeled T1 NETWORK and T1 FRACTIONAL provide status information using a color coded message format. Table 1 gives a description of all faceplate LEDs for the BCU when used with the Total Access 850 system. Table 1. BCU Faceplate LEDs For these LEDs...

This color light...

Indicates that...

Network/Frac T1

OFF there is no power to the system.

RED the unit is in Red Alarm (meaning the T1 is down, not connected, or framing is improperly configured).

YELLOW the unit is receiving Yellow Alarm (meaning the far end unit is in Red Alarm).

Solid GREEN the unit is functioning normally.

Blinking GREEN the network T1 interface is in Test mode.

DIP-Switch Settings The Total Access 850 BCU can be provisioned from DIP-switches (S1) mounted on the PCB, or through screen menus accessed via the faceplate ADMIN interface. Basic T1 provisioning, clock source, and CSU loopback options are found on the DIP-switch panel. Table 2 gives DIP-switch provisioning information. DIP-switch S1 must be provisioned without the BCU in the chassis. Once the BCU is installed, any software provisioning made will override the DIP-switch settings. If the BCU is withdrawn and reinserted (power-cycled), the software options remain in effect. If a DIP-switch setting is changed while the BCU is withdrawn, the new DIP-switch setting takes effect. If none of the DIP-switch settings were changed, the unit will be provisioned for the last software settings. Table 2. BCU DIP-Switch S1 Options Switch

Function

Description

S1-1

Framing Format

Enables either Extended Superframe Format (ESF) or Superframe Format (SF). This option must be configured identically with all other T1 network equipment on this circuit.

26

ON*

SF

OFF

ESF

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 27

Total Access 850 System Manual

Section 2 Engineering Guidelines

Table 2. BCU DIP-Switch S1 Options (Continued) Switch

Function

Description

S1-2

Line Code

Enables Bipolar Eight-Zero Substitution (B8ZS), which allows for Clear Channel operation for the T1 carrier system, or enables Alternate Mark Inversion (AMI). This option must be configured identically with all other T1 network equipment on this circuit.

S1-3

S1-4

S1-5 S1-6

S1-7 S1-8

TR-08 Signaling

CSU Loopback

Timing Mode A Timing Mode B

Line Build Out A Line Build Out B

ON*

AMI

OFF

B8ZS

Enables or disables the TR-08 signaling option. When enabled, S1-1 is ignored. ON*

Enabled

OFF

Disabled

Enables the CSU loopback function. When this switch is enabled, the Total Access 850 will respond to CSU loopbacks sent from a remote network device or test equipment. ON

Disabled

OFF*

Enabled

Determines the clock source options for the Total Access 850 system. S1-5/S1-6

Function

OFF/OFF

Loop timing: Derives timing from the network T1.

ON/OFF

External Timing: Derives timing from the external bits clock.

OFF/ON

Local Timing: Clock generated from internal timing source.

ON*/ON*

Loop Timing: Derives timing from the network T1.

Sets the attenuation properties to configure the receiver sensitivity in decibels (dB). Additional settings can be provisioned through the terminal menu interface. S1-7/S1-8

Setting

OFF/OFF

0 dB/0-133 ft

ON/OFF

-7.5 dB

OFF/ON

-15 dB

ON*/ON*

-22 dB

* Denotes factory default settings.

64203376L1-1B

© 2004 ADTRAN, Inc.

27

Page 28

Section 2 Engineering Guidelines

Total Access 850 System Manual

Faceplate Bantam Jack The faceplate bantam jack provides a means to monitor the network T1 connected to the rear of the Total Access 850 chassis. The jacks accept standard 310-type bantam plugs. Figure 2 display the bantam jack monitoring points. Receiver Circuitry T1 T1 RX PAIR R1

Clock and Data Recovery

Line Format Decoder

To Backplane

DJAT

Line Format Encoder

From Backplane

MON IN Test Jack

T1 T TX PAIR R

Equalizer

Transmitter Circuitry MON OUT Test Jack

Local Loopback Point

Line Loopback Point

Payload/CSU Loopback Point

Figure 2. BCU Bantam Jack Test Diagram

Faceplate TEST Connector The faceplate TEST connector provides the necessary clock output required by standard DS0 Logic Test equipment (such as a TPI 108/109 test set). Specifically, the Test connector outputs 8 kHz and 64 kHz clock reference signal. DS0 test equipment is used to test DS0 access modules such as the OCU DP, DS0 DP, or UBR1TE. Once the test equipment is connected to the reference clock source, individual tests can be performed on DS0 access modules using the faceplate bantam jacks on each unit. Figure 3 on page 28 illustrates the DB-9 TEST connector.

6 TEST

7 8 9

1

+5 V

2

GND

3

64 kHz

4

8 kHz

5

Figure 3. BCU DB-9 Test Connector

T1 Router Controller Unit (4200376L1#TDM and 4200376L1#ATM) The following is operational information pertaining to the T1 Router Controller Unit when used with the Total Access 850 system.

28

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 29

Total Access 850 System Manual

Section 2 Engineering Guidelines

Faceplate CRAFT Interface Use the CRAFT port located on the RCU faceplate to configure the system via an EIA-232 connection. Table 3 displays the CRAFT port pinout. Table 3. T1 RCU CRAFT (DB-9, Female) Pinout Pin

Name

Description

1, 4, 6-9

UNUSED, 2

RD

Receive Data (Output)

3

TD

Transmit Data (Input)

5

SG

Signal Ground

Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 4 gives a description of all faceplate LEDs for the T1 RCU when used with the Total Access 850 system. Table 4. T1 RCU Faceplate LEDs For these LEDs...

This color light...

Indicates that...

PWR

OFF there is no power to the system.

Solid GREEN the system is connected to an active power source.

OFF there are no active T1 alarms on the system.

ON there is an active T1 alarm (yellow, red, or blue alarm) on the system.

T1 TEST

AMBER the network T1 is in test mode (loopback).

T1 ERROR

Blinking RED there are errors on the network T1 (framing errors, bipolar violations, or CRC errors).

V.35 TD

Blinking GREEN there is transmit data detected on the V.35 port. This LED blinks with data traffic.

V.35 RD

Blinking GREEN there is received data detected on the V.35 port. This LED blinks with data traffic.

ETH LI

OFF there is no active Ethernet link.

Solid GREEN there is a valid Ethernet link on the 10BaseT interface.

Blinking GREEN there is received or transmitted data detected on the Ethernet interface. This LED blinks with data traffic.

T1 ALARM

ETH TX/RX

Faceplate Bantam Jack The faceplate bantam jack provides a means to monitor the network T1 connected to the rear of the Total Access 850 chassis. The jacks accept standard 310-type bantam plugs. Figure 4 displays the bantam jack monitoring points.

64203376L1-1B

© 2004 ADTRAN, Inc.

29

Page 30

Section 2 Engineering Guidelines

Total Access 850 System Manual

Receiver Circuitry T1 T1 RX PAIR R1

Clock and Data Recovery

Line Format Decoder

To Backplane

DJAT

Line Format Encoder

From Backplane

MON IN Test Jack

T1 T TX PAIR R

Equalizer

Transmitter Circuitry Local Loopback Point

MON OUT Test Jack

Line Loopback Point

Payload/CSU Loopback Point

Figure 4. RCU Bantam Jack Test Diagram

3rd GEN T1 Router Controller Unit (1203376L1) The following is operational information pertaining to the 3rd Generation T1 Router Controller Unit when used with the Total Access 850 system.

Faceplate CRAFT Interface Use the CRAFT port on the RCU faceplate to configure the system via an EIA-232 connection. Table 5 on page 30 displays the CRAFT port pinout. Table 5. 3rd GEN T1 RCU CRAFT (DB-9, Female) Pinout Pin

Name

1, 4, 6-9

UNUSED, Description

2

RD

Receive Data (Output)

3

TD

Transmit Data (Input)

5

SG

Signal Ground

Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 6 gives a description of all faceplate LEDs for the T1 RCU when used with the Total Access 850 system.

30

© 2004 ADTRAN, Inc.

64203376L1-1B