The text of a manual · part 2 of 30
Total Access 850 System Manual, pages 13 to 22
Pages 13 to 22 of 292: Table of Contents; System Description
The original document is the PDF (3.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Adtran 1200375L1
Page 13
Total Access 850 System Manual
Table of Contents
Table of Contents Section 1
System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 This section provides an overview of the Total Access 850 system.
Section 2
Engineering Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 This section provides equipment dimensions, power requirements, front panel design, rear panel design, LEDs, and at-a-glance specifications.
Section 3
Network Turnup Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 This section provides shipment contents list, grounding instructions, mounting options, and specifics of supplying power to the unit.
Section 4
User Interface Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 This section provides detailed descriptions of all menu options and configuration parameters available for the Total Access 850 when used with a Router Control Unit (RCU). This section does not apply to systems that employ a Bank Control Unit (BCU). This section of ADTRAN’s Total Access 850 System Manual is designed for use by network administrators and others who will configure and provision the system. It contains information about navigating the VT100 user interface, configuration information, and menu descriptions.
Section 5
Detail Level Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 DLP-1 DLP-2 DLP-3 DLP-4 DLP-5 DLP-6 DLP-7 DLP-8 DLP-9 DLP-10 DLP-11 DLP-12 DLP-13 DLP-14 DLP-15 DLP-16 DLP-17
Section 6
Connecting a VT100 Terminal or PC to the CRAFT Port . . . . . . . . . . . . . . . . . . . . . 215 Logging in to the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 Setting IP Parameters for the Total Access 850 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219 Verifying Communications Over an IP LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 Connecting to the Total Access 850 Using Telnet . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 Adding/Removing Users and Changing Password Security Levels . . . . . . . . . . . . . . 229 Updating the Firmware using TFTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 Updating the Firmware using XMODEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237 Saving the Current Configuration Using TFTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239 Loading a Configuration Using TFTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 Saving and Transferring a Current Configuration Using XMODEM. . . . . . . . . . . . . 245 Loading a Configuration Using XMODEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 Saving and Loading Text Configuration using Terminal Command Line . . . . . . . . . 249 A.03 to A.04 Firmware Upgrade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253 Using the ADTRAN Utility Syslog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 Connecting the Alarm Contacts and the External Input . . . . . . . . . . . . . . . . . . . . . . . 261 Configuring the Total Access 850 for Dual T1 Maps. . . . . . . . . . . . . . . . . . . . . . . . . 265
ADTRAN Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269 This section provides instructions for configuring and using the ADTRAN Utilities software programs including Telnet, VT100, Syslog, and TFTP.
Section 7
MIBs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279 This section is divided into two parts: (1) SNMP information for TDM units and (2) SNMP information for ATM units. Each section details the Management Information Bases (MIBs) supported, MIB Compilation Order, Traps Supported, and MIB Variables supported.
64203376L1-1B
© 2004 ADTRAN, Inc.
13
Page 14
Table of Contents
14
Total Access 850 System Manual
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 15
SYSTEM DESCRIPTION This section provides an overview of the Total Access 850 system.
CONTENTS Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Configuration and Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Software Upgradeable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Signaling Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Integrated Components (with RCU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Performance Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Total Access 850 Bank Controller Unit (BCU) (P/N 1200373L1) . . . . . . . . . . . . . . . . . . . . . . . . 21 BCU with Fractional T1 (P/N 1200373L2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 T1 RCU (P/N 4203376L1#TDM, 4203376L1#ATM and 1203376L1) . . . . . . . . . . . . . . . . . . . . . 21 SDSL RCU (P/N 1200377L1, 1200377L2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Power Supply Unit (P/N 1175006L2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Echo Canceller with ADPCM (P/N 1203384L2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Nx56/64K (V.35) Module (P/N 1200372L1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Quad FXS Access Module (P/N 1175408L2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Quad FXO Access Module (P/N 1175407L2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 OCU DP Access Module (P/N 1180005L1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 U-BR1TE Access Module (P/N 1180020L1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 E&M/TO Access Module (P/N 1180402L1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Dual V.35 Access Module (P/N 1180025L1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 DSX-1 Access Module (P/N 1200385L1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Single DS0 DP Access Module (P/N 1180003L1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
64203376L1-1B
© 2004 ADTRAN, Inc.
15
Page 16
Section 1 System Description
16
Total Access 850 System Manual
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 17
Total Access 850 System Manual
1.
Section 1 System Description
SYSTEM OVERVIEW
The Total Access 850 is an integrated access device designed for cost-effective deployment of voice and data services at the customer premises. The Total Access 850 system benefits integrated communications providers, such as CLECs, ILECs, and ISPs, who require a customer premises device that integrates voice and data functions. It provides a viable migration path from TDM to packet-based technology (see Modules on page 18 for details). The Total Access 850 features remote management, an integrated IP router, and special services slots. Preconfigured Total Access 850 packages are available. The Total Access 850 is a modular device with two common slots, six access slots for FXS, FXO, Dual V.35, and UBR1TE modules, and two slots for special access modules. The FXS, FXO, Dual V.35, and UBR1TE modules are supported in the Router Control Unit (RCU); however, the Bank Controller Unit (BCU) also supports E&M, OCU DP, Single DS0 DP, and Nx56/64 modules. Using local or remote inband management, carriers can turn features, functions, and access ports on and off. Easy access to modules, common modules, power supplies, and the battery back-up system simplifies maintenance procedures. Hot-swappable modules may be replaced without disrupting other units. The four-circuit-per-module design ensures that only four analog circuits are affected when replacing a module. The Total Access 850 is a compact, NEBS-compliant cabinet suitable for the customer premises or the central office. The 2U design uses little rack space; or when wallmounted, the 8½-inch by 11-inch chassis occupies a space the size of a piece of notebook paper. Two Total Access 850 systems can be mounted side-by-side in either 19-inch or 23-inch relay racks.
2.
FEATURES AND BENEFITS
The following list gives Total Access 850 features and benefits. Some features are module-dependent.
Configuration and Management • • • • •
VT100 Emulation SNMP Management (with RCU) Telnet (with RCU) Dial-up remote management via external analog modem Six levels of password protection and privileges for Telnet access (with RCU)
Software Upgradeable • • •
Flash memory TFTP download (with RCU) XMODEM via control port
Signaling Support • • • • •
T1/FT1 integrated access TDM to ATM migration (with RCU) Upgradeable to DSL using SDSL RCU TR-08 signaling support Analog FXS and FXO voice expansion (four per module)
64203376L1-1B
© 2004 ADTRAN, Inc.
17
Page 18
Section 1 System Description
Total Access 850 System Manual
Integrated Components (with RCU) • • •
IP router DSX-1 T1/PBX interface V.35 Nx56/64 DTE interface
Testing • •
Local and remote: payload/line, V.54 (depending on installed modules) Patterns: 511, QRSS, all ones, all zeros (depending on installed modules)
Performance Monitoring • • •
3.
Reports: Information stored for last 24 hours in 15 minute increments Performance statistics per TR54016, T1.403, RFC1406 Alarm reporting per TR54016, T1.403
MODULES
The Total Access 850 system offers several different system modules (including the power supply), system resource modules, and access modules.
System Modules • • • • • • • •
Bank Controller Unit (BCU) (P/N 1200373L1) BCU with Fractional T1 (P/N 1200373L2) T1 Router Control Unit (RCU) with TDM software (P/N 4203376L1#TDM) T1 Router Control Unit (RCU) with ATM software (P/N 4203376L1#ATM) 3rd Generation T1 Router Control Unit (RCU) (P/N 1203376L1) SDSL RCU (P/N 1200377L1) 2nd Generation SDSL RCU (P/N 1200377L2) Power Supply Unit (P/N 1175006L2)
Resource Modules • •
Echo Canceller with ADPCM (P/N 1203384L2) Nx56/64K Data Service Unit (DSU) (P/N 1200372L1)
Access Modules • • • • •
18
Quad FXS Access Module (P/N 1175408L2) Quad FXO Access Module (P/ N 1175407L2) UBR1TE Access Module (P/N 1180020L1) Dual V.35 Access Module (P/N 1180025L1) DSX-1 Access Module (P/N 1200385L1)
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 19
Total Access 850 System Manual
Section 1 System Description
Access Modules (Requiring a BCU) • • • •
E&M/TO Access Module (P/N 1180402L1) OCU DP Access Module (P/N 1180005L1) Single DS0 DP Access Module (P/N 1180003L1) Nx56/64 (V.35) Access Module (P/N 1200372L1)
Each access module is hot-swappable, with configuration restored upon replacement.
Replacing an access module with a different module type will result in configuration loss.
Total Access 850 Bank Controller Unit (BCU) (P/N 1200373L1) The BCU is a common module plug-in unit with a built-in CSU. The BCU provides all control functions for the Total Access 850 common units and all individual access modules. A faceplate DB-9 (ADMIN) interface provides access for a VT100 terminal for screen menu provisioning, and bantam test jacks provide transmit and receive monitoring. An additional DB-9 (TEST) interface provides timing for DS0 test equipment. Faceplate LEDs show status information for the network and Fractional T1 (DSX-1 on L2 only). The unit consists of a main circuit board and daughter card and inserts directly in the controller slot on the Total Access 850 shelf. An 8-position DIP-switch is mounted on the daughter card and is used for T1 provisioning and clocking.
BCU with Fractional T1 (P/N 1200373L2) The BCU with Fractional T1 provides all the functionality of the traditional BCU as well as a DSX-1/Fractional T1 interface for additional T1 service.
T1 RCU (P/N 4203376L1#TDM, 4203376L1#ATM and 1203376L1) The RCU is a dual board assembly that provides the network interface for the Total Access 850 system. The RCU can provision, test, and provide status for any card in the system. A faceplate DB-9 (CRAFT) interface provides access for a VT100 terminal for screen menu provisioning, and bantam test jacks provide transmit and receive monitoring capabilities. Terminal menu access is also provided through the RJ-45 CRAFT interface located on the rear of the chassis. Faceplate LEDs show status information for the network port and Ethernet port. In addition, the RCU has an integrated router access through the 10BaseT connector on the backplane of the chassis. (3rd Generation RCUs provide a 10/100BaseT interface.) A DSX-1/Fractional T1 interface for additional T1 service is also provided.
SDSL RCU (P/N 1200377L1, 1200377L2) The SDSL RCU is a dual board assembly that includes an SDSL network interface, Nx56/64 V.35 interface, and built-in IP router. The SDSL RCU can provision, test, and provide status for any card in the system. The faceplate has a DB-9 (CRAFT) port connection, and network, V.35, and Ethernet LEDs. An additional RJ-45 terminal menu interface is located on the rear of the chassis and is labeled CRAFT. The SDSL RCU is only used in ATM applications. It supports vendor-specific SDSL protocols, ATM, and Copper Mountain Frame Relay. Therefore, the SDSL RCU can interoperate with a variety of DSLAMs, including Lucent, Nortel, Copper Mountain, Nokia, and Alcatel. It also supports several voice gateways, including Jetstream and Broadband Loop Emulation Services (BLES) gateways. The SDSL RCU has 64203376L1-1B
© 2004 ADTRAN, Inc.
19
Page 20
Section 1 System Description
Total Access 850 System Manual built-in Echo Cancellation for up to 24 voice ports. Adaptive Differential Pulse Code Modulation (ADPCM) resources are also built-in for up to 16 ports.
Power Supply Unit (P/N 1175006L2) The Total Access 850 PSU is a common module plug-in unit designed to supply power to the system. The faceplate contains a momentary ACO pushbutton, a ring voltage Enable/Disable pushbutton, a Bank Alarm LED, Ring LED, and a power LED. All power, ground, and timing signals are pre-wired, thus eliminating additional wiring requirements.
Echo Canceller with ADPCM (P/N 1203384L2) An Echo Canceller Module is available for use with the legacy T1 RCU (P/N 1200376L1 - ATM firmware only). Echo cancellation and ADPCM resources are built into the 3rd Generation T1 (P/N 1203376L1) and SDSL (P/N 1200 377Lx) versions of the RCU, so this module is not required when using the SDSL RCU. The Echo Canceller Module provides G.168 echo cancellation for voice over ATM applications and includes Adaptive Differential Pulse Code Modulation (ADPCM). ADPCM is a speech coding method which uses fewer bits than traditional Pulse Code Modulation (PCM), allowing the user to get more analog voice calls on less bandwidth. This is a dual-slot module and must be installed in the system resource slots (A and B). The Echo Canceller module ADPCM functionality automatically shifts ON/OFF when fax or modem calls are placed. To find out the current status of the Echo Canceller functionality, check the current status of each FXS port. The path of the current status can be found at the following path: L2 PROTOCOL (T1 ATM–T1–ATM) > STATUS > PVC STATUS > PROTOCOL STATUS > POTS STATS > CODING TYPE (this will display either PCM or ADPCM).
Nx56/64K (V.35) Module (P/N 1200372L1) This module is only available in Total Access 850 systems using a BCU. The Nx56/64k (V.35) Module activates the V.35 port on the rear of the chassis. This is a dual-slot module and must be installed in the system resource slots (A and B).
Quad FXS Access Module (P/N 1175408L2) The Quad FXS Module provides analog voice extension for the Total Access 850 platform. Four analog voice ports are used to connect to analog phones. The Quad FXS Module supports Foreign Exchange Subscriber, Dial Pulse Terminate (DPT), and Private Line Automatic Ringdown (PLAR) and provides Ground Start/Loop Start to E&M conversion capability.
Quad FXO Access Module (P/N 1175407L2) The Foreign Exchange Office (FXO) module interfaces to the Central Office switch and to an FXS or RPOTS card over a T1 facility. Four analog voice ports on the FXO access module provide four individual connections to the switch. The FXO supports standard Loop Start and Ground Start options as well as Dial Pulse Terminate (DPT) functionality. Up to six Quad FXO Access Modules may be installed in the Total Access 850.
20
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 21
Total Access 850 System Manual
Section 1 System Description
OCU DP Access Module (P/N 1180005L1) This module is only available in Total Access 850 systems using a BCU. The OCU DP module is a single port access module used to provide the interface between a DS0 time slot on the T1 and a 4-wire DDS device at the customer premises. The OCU DP supports up to 18 kft of copper for remote DSU connectivity.
U-BR1TE Access Module (P/N 1180020L1) The UBR1TE is a module that plugs into a single access slot of the Total Access 850. It provides an ISDN U-interface and allows transport of Basic Rate 2B+D information over T1 carriers and twisted pair wiring.
E&M/TO Access Module (P/N 1180402L1) This module is only available in Total Access 850 systems using a BCU. The E&M/TO module is a single port Ear and Mouth/Transmit Only access module. The primary application for this module is to provide PBX foreign exchange at the customer premises or tandem central office applications. This module is intended for interface with intra-building wiring. The E&M/TO module supports both 2- and 4- wire operation.
Dual V.35 Access Module (P/N 1180025L1) The Dual V.35 Access Module is a DSU data port with two circuits that each deliver serial data over a V.35 interface. The module is designed as a dual slot module; it requires two slots in the Total Access 850 chassis. Each circuit of the Dual V.35 Access Module provides up to 24 channels of data in 56 or 64 kbps increments. Design operation is to transmit or receive high rate synchronous data from data terminal equipment (DTE) over a T1 interface. This module is currently only supported by the TDM version of the T1 RCU.
DSX-1 Access Module (P/N 1200385L1) This module is only available in Total Access 850 systems using a T1 RCU. The DSX-1 Module installs into the Total Access 850 system to provide an additional DSX-1 interface (RJ-45) for support of multiple PBXs or other equipment with a DSX-1/FT1 interface. The module is functional in any of the six Total Access 850 module slots.
Single DS0 DP Access Module (P/N 1180003L1) This module is only available in Total Access 850 systems using a BCU. The DS0 Dataport is a single port access module that serves as an interface to the basic DDS DS0 (64 kbps) signal to a T-carrier line.This module is used in conjunction with an ADTRAN All-Rate Office Channel Unit (OCU) dataport or Total Reach DDS dataport located at the end office to extend the DDS network to an end office which has exclusively-served voice channels.
64203376L1-1B
© 2004 ADTRAN, Inc.
21
Page 22
Section 1 System Description
22
Total Access 850 System Manual
© 2004 ADTRAN, Inc.
64203376L1-1B