Page 125
Total Access 850 System Manual
Section 4 User Interface Guide
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PVC(S) > RX BYTES Number of Frame Relay bytes that have been received via this DLCI.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PVC(S) > DE COUNT Number of packets received on this DLCI with the Discharge Eligible (DE) bit set.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PVC(S) > CR COUNT Number of packets received on this DLCI with the Command Response (CR) bit set.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PVC(S) > BECN COUNT Number of packets received on this DLCI with the Backward Explicit Congestion Notification (BECN) bit set.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PVC(S) > FECN COUNT Number of packets received on this DLCI with the Forward Explicit Congestion Notification (FECN) bit set.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PVC(S) > UNKNOWN FRAME RX Number of frames that have been received that the unit does not know where to route.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PVC(S) > CLEAR STATS Clears all gathered statistics for this interface and returns counters to 0.
L2 PROTOCOL (T1 TDM FIRMWARE) – T1 INTERFACE > HDLC PROTOCOL View the status of the T1 interface with the L2 PROTOCOL set to HDLC.
L2 PROTOCOL (T1 TDM–T1–HDLC) > STATUS View the status of traffic flow and utilization for the T1 interface with an L2 PROTOCOL set to HDLC.
L2 PROTOCOL (T1 TDM–T1–HDLC) > STATUS > TX PKTS Number of packets transmitted on the T1 interface.
64203376L1-1B
© 2004 ADTRAN, Inc.
125
Page 126
Section 4 User Interface Guide
Total Access 850 System Manual
L2 PROTOCOL (T1 TDM–T1–HDLC) > STATUS > RX PKTS Number of packets received on the T1 interface.
L2 PROTOCOL (T1 TDM–T1–HDLC) > STATUS > TX BYTES Number of bytes transmitted on the T1 interface.
L2 PROTOCOL (T1 TDM–T1–HDLC) > STATUS > RX BYTES Number of bytes received on the T1 interface.
L2 PROTOCOL (T1 TDM–T1–HDLC) > STATUS > CURRENT UTIL (b/s) Current utilization of the T1 interface bandwidth presented in bits per second.
L2 PROTOCOL (T1 TDM–T1–HDLC) > STATUS > CURRENT UTIL (%) Current utilization of the T1 interface bandwidth presented in percentage format.
L2 PROTOCOL (T1 TDM–T1–HDLC) > STATUS > AVERAGE UTIL (b/s) Average utilization of the T1 interface bandwidth (since the last stats reset) presented in bits per second.
L2 PROTOCOL (T1 TDM–T1–HDLC) > STATUS > AVERAGE UTIL (%) Average utilization of the T1 interface bandwidth (since the last stats reset) presented in percentage format.
L2 PROTOCOL (T1 TDM–T1–HDLC) > STATUS > TX PKTS Number of packets transmitted on the T1 interface
L2 PROTOCOL (T1 TDM–T1–HDLC) > STATUS > CLEAR STATS Clears all the gathered statistics for this interface and returns the counters to 0.
L2 PROTOCOL (T1 TDM FIRMWARE) – T1 INTERFACE > AUTO PROTOCOL View the status of the T1 interface with the L2 PROTOCOL set to AUTO (using Auto-config feature).
L2 PROTOCOL (T1 TDM–T1–AUTO) > STATUS View the status of the auto detect function and traffic flow for the T1 interface with an L2 PROTOCOL set to AUTO.
126
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 127
Total Access 850 System Manual
Section 4 User Interface Guide
L2 PROTOCOL (T1 TDM–T1–AUTO) > STATUS > STATE This field represents the state of the auto detect/configuration function. The possible state are: OFF
The T1 interface is down, so the auto-detect/configuration process is currently idle.
DETECTING L2 PROTOCOL
The T1 interface is up and waiting for the first control/signaling packet.
CONFIRMING FR
The T1 interface is up and one FR signaling packet has been received
CONFIRMED FR
The T1 interface is up and two FR signaling packets have been received. It takes two consecutive control/signaling packets of the same type to confirm the detected protocol.
CONFIRMING PPP
The T1 interface is up and one PPP control packet has been received.
CONFIRMED PPP
The T1 interface is up and two PPP control packets have been received. It takes two consecutive control/signaling packets of the same type to confirm the detected protocol.
L2 PROTOCOL (T1 TDM–T1–AUTO) > STATUS > TX PKTS Number of packets transmitted out of the WAN port.
L2 PROTOCOL (T1 TDM–T1–AUTO) > STATUS > RX PKTS Number of packets received on WAN port.
L2 PROTOCOL (T1 TDM–T1–AUTO) > STATUS > TX BYTES Number of bytes transmitted out of the WAN port.
L2 PROTOCOL (T1 TDM–T1–AUTO) > STATUS > RX BYTES Number of bytes received out of the WAN port.
L2 PROTOCOL (T1 TDM–T1–AUTO) > STATUS > CLEAR STATS Clears all the gathered statistics for this interface and returns the counters to 0.
64203376L1-1B
© 2004 ADTRAN, Inc.
127
Page 128
Section 4 User Interface Guide
Total Access 850 System Manual
L2 PROTOCOL (T1 ATM FIRMWARE) Use the L2 PROTOCOL menu to select the L2 PROTOCOL, configure the protocol specific parameters, and view the status as shown in Figure 8. The following menus are for Total Access 850 systems using T1 ATM firmware.
Figure 9. L2 Protocol (T1 TDM) Menu
For convenience, the following heading notations identify the type of firmware and L2 protocol configured in the Total Access 850 system:
L2 Protocol (T1 ATM – T1 – ATM) Firmware and RCU type. (For example, T1 TDM, T1 ATM, SDSL.)
128
Interface type. (For example, T1, Ethernet, etc.)
© 2004 ADTRAN, Inc.
Configured Layer 2 protocol. (For example, ATM or CuMTN.)
64203376L1-1B
Page 129
Total Access 850 System Manual
Section 4 User Interface Guide
L2 PROTOCOL (T1 ATM FIRMWARE) – T1 INTERFACE Configure the L2 PROTOCOL parameters and view the status of the T1 interface using items from this menu.
L2 PROTOCOL (T1 ATM – T1) > PROTOCOL Configure the L2 PROTOCOL mode. Choices are ATM and CUMTN (def). Selecting ATM configures the interface for Asynchronous Transfer Mode signaling on Layer 2. Selecting CUMTN configures the interface for Copper Mountain frame relay signaling on Layer 2.
L2 PROTOCOL (T1 ATM – T1) > PROTOCOL > ATM Asynchronous Transfer Mode allocates bandwidth on demand, automatically adjusting the network capacity to meet the system needs. Fixed-length cells (53 octet) require lower processing overhead and allow higher transmission speeds than traditional packet switching methods. ATM uses five octet headers in each fifty-three octet cell to match cells with specific virtual channels to which they belong.
L2 PROTOCOL (T1 ATM – T1) > PROTOCOL > CUMTN Copper Mountain Frame Relay is a data link layer protocol that uses Frame Relay instead of ATM on the subscriber loop. Frame relay is a switched layer protocol that handles virtual circuits using High-Level Data Link Control (HDLC) encapsulation. Frame Relay uses statistical multiplexing as opposed to time-division-multiplexing many logical connections over a single physical link.
L2 PROTOCOL (T1 ATM FIRMWARE) – T1 INTERFACE > ATM Configure the L2 PROTOCOL parameters and view the status of the T1 interface using ATM protocol from this menu.
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG Configure the L2 PROTOCOL parameters for the T1 interface using ATM protocol.
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > ATM CONFIG Use the ATM CONFIG menu to set the parameters listed below.
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > ATM CONFIG > IDLE CELLS The IDLE CELLS format must be configured for either ATM FORUM (UNASSIGNED) or ITU (IDLE). Configuring this setting incorrectly for a particular circuit will cause poor performance at the ATM Layer. The default is ATM FORUM (UNASSIGNED).
64203376L1-1B
© 2004 ADTRAN, Inc.
129
Page 130
Section 4 User Interface Guide
Total Access 850 System Manual
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > ATM CONFIG > DATA SCRAMBLING DATA SCRAMBLING can be ENABLED or DISABLED for cell traffic. Configuring this setting incorrectly for a particular circuit will cause poor performance at the ATM Layer. The setting must match the configuration setting of the ATM switch or DSLAM at the other end of the circuit.
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > ATM CONFIG > HEC COSET Header Error Control is located in the last (5th) byte of the ATM cell header that checks for cell integrity only. The Coset polynomial is applied to the received HEC for comparison with the HEC generated internally. HEC errors may be detected after synchronization, and any detected bit errors prompt that the cell be dropped. The choice are ENABLED (def) or DISABLED.
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > PVC CONFIG Configure up to six ATM PVCs from this menu (five data and one voice PVC). To insert a new PVC, press the I key when over the NUM column. A new inserted PVC will always be set up with the default parameters. To copy parameters from an old PVC to the new PVC, use the copy (C) and paste (P) keys. Entire configuration trees can be copied with this method.
To delete an unused PVC, use the D key when the cursor is over the number in the NUM column. Once deleted, the PVC is gone permanently.
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > PVC CONFIG > NUM Displays the index number for the PVC entry.
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > PVC CONFIG > ACTIVE Activates the ATM PVC. The choices are YES or NO. Default is NO.
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > PVC CONFIG > SUB-INTERFACE The T1 Sub-Interface is ATM [0.0] that represents the T1 physical and logical ports respectively. This is a read-only field.
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > PVC CONFIG > VPI ATM Virtual Path Identifier located in the ATM cell header identifies the virtual path over which this port is running. The range is 0-256. The default is 0.
130
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 131
Total Access 850 System Manual
Section 4 User Interface Guide
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > PVC CONFIG > VCI This is the ATM Virtual Channel Identifier that serves as an address for the virtual channel cell transmissions between two devices. The range is 0-65355. The default setting is 38.
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > PVC CONFIG > CONNECTION Select the physical and logical method of data transfer over the virtual path. There are three valid connection entries: ROUTER, V35, and VOICE. Select ROUTER to connect traffic from this PVC to the Total Access 850 integral IP router. Select V35 to connect traffic from this PVC to a V.35 interface on the system. Select VOICE to connect traffic from this PVC to a voice connection (on a DSX-1 or FXS interface).
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > PVC CONFIG > SETUP (ROUTER) Use these menus to configure the router parameters for this logical connection from the router to the T1 interface. These menus are only applicable when the CONNECTION parameter is set to ROUTER. CONNECTION (ROUTER) > SETUP > PROTOCOL
Selects the data-link protocol for the PVC connection between the T1 interface and the router. The choices are: IP (def) and PPP. CONNECTION (ROUTER) > SETUP > MODE
Identifies how the data will be transferred through the Total Access 850 system. The following choices are available: ROUTE IP (def) – All IP data for this PVC is routed through the Total Access 850 integral router. BRIDGE ALL – All data for this PVC is bridged through the Total Access 850 system. ROUTE IP/BRIDGE OTHER – All IP data for this PVC is routed through the Total Access 850 integral router and all other data is bridged through the system. CONNECTION (ROUTER) > SETUP > PPP SETUP
Provides PPP configuration parameters for the PVC. These menus are only visible when the MODE is set to PPP. AUTHENTICATION
Contains the required parameters for PPP peer authentication and for being authenticated by the PPP peer. Authentication is applied between the unit and the PPP peer as described in the submenus.
64203376L1-1B
© 2004 ADTRAN, Inc.
131
Page 132
Section 4 User Interface Guide
Total Access 850 System Manual
TX METHOD
Specifies the method the Total Access 850 uses to obtain PPP authentication from the peer. There are four possible selections: NONE
The connection will not allow the PPP peer to authenticate it.
PAP, CHAP, OR EAP
The unit will ask for EAP during the first PPP LCP negotiation and allow the PPP peer to negotiate down to CHAP or PAP.
CHAP OR EAP
The unit will ask for EAP during the first PPP LCP negotiation and allow the PPP peer to negotiate down to CHAP but not PAP.
EAP ONLY
The unit will only allow EAP to be negotiated. If the PPP peer is not capable of doing EAP, then the connection will not succeed.
PAP ONLY
The unit will only allow PAP to be negotiated. If the PPP peer is not capable of doing PAP, then the connection will not succeed.
RX METHOD
Specifies the method the Total Access 850 uses to authenticate the PPP peer. There are four possible selections: NONE
The connection will not allow the PPP peer to authenticate it.
PAP, CHAP, OR EAP
The unit will ask for EAP during the first PPP LCP negotiation and allow the PPP peer to negotiate down to CHAP or PAP.
CHAP OR EAP
The unit will ask for EAP during the first PPP LCP negotiation and allow the PPP peer to negotiate down to CHAP but not PAP.
EAP ONLY
The unit will only allow EAP to be negotiated. If the PPP peer is not capable of doing EAP, then the connection will not succeed.
PAP ONLY
The unit will only allow PAP to be negotiated. If the PPP peer is not capable of doing PAP, then the connection will not succeed.
PPP
Configure the PPP specific parameters such as MAX CONFIG, MAX TIMER, MAX FAILURE, and FORCE PEER IP ADDRESS from this menu.
132
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 133
Total Access 850 System Manual
Section 4 User Interface Guide
MAX CONFIG
This value is the number of unanswered configuration-requests that should be transmitted before resetting PPP negotiations. the possible values are 5, 10, 15, and 20 (def). MAX TIMER (SEC)
This value is the number of seconds to wait between unanswered configuration-requests. The possible values are 1 SEC, 2 SECS, 3 SECS (DEF), 5 SECS, and 10 SECS.
MAX FAILURE
Due to the nature of PPP, configuration option may not be agreed upon between two PPP peers. This value is the number of configuration-naks that should occur before an option is configuration-rejected. The possible values are 5 (DEF), 10, 15, and 20. FORCE PEER IP ADDRESS
This option forces the PPP to negotiate the IP address entered instead of allowing another address to be assigned by the remote end. The default is NO.
KEEPALIVE PERIOD
This option allows the user to generate PPP keepalive packets that can be sent every 1 minute, 2 minutes, or every 5 minutes. A value of 0 (OFF) disables the PPP keepalive packet generating feature. The default is 0 (OFF). PPP ENCAPSULATION
This option allows the user to set the encapsulation modes for PPP over ATM. LLC has an encapsulation header in the AAL5 frame indicating it is encapsulating PPP. VC-Mux does not have a header, and is therefor dedicated to using PPP. The choices are LLC or VC-MUX. The default is VC-MUX.
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > PVC CONFIG > SETUP (V35) Use these menus to configure the V35 parameters for this logical connection from the T1 interface to the V.35 port. These menus are only applicable when the CONNECTION parameter is set to V35. CONNECTION (V35) > SETUP > SETUP
Use these menus to configure the Protocol mapping, DE map, and FECN map for the V.35 PVC connections.
64203376L1-1B
© 2004 ADTRAN, Inc.
133
Page 134
Section 4 User Interface Guide
Total Access 850 System Manual
CONNECTION (V35) > SETUP > SETUP > PROTOCOL MAPPING
Network providers have the ability to provision each PVC pair with an encapsulation mode to ensure interoperability between terminal equipment. The choices are TRANSPARENT or TRANSLATION (def). TRANSLATION mode is most common and carries multiple upper layer protocols over Frame Relay and ATM PVCs. CONNECTION (V35) > SETUP > SETUP > DE MAP
Maps Frame Relay Discard Eligible (DE) bit to the ATM Cell Loss Priority (CLP) bit. The choices are DE = 0, DE = 1, and CONVERT (map DE TO CLP). The factory default setting is DE = 0. CONNECTION (V35) > SETUP > SETUP > FECN MAP
Allows mapping of Frame Relay FECN (Forward Explicit Congestion Notification) bit to ATM EFCI (Explicit Forward Congestion Indicator) bit. The choices are NO MAP FECN and MAP FECN. The factory default setting is NO MAP FECN. CONNECTION (V35) > SETUP > DLCI MAPPING
Use these menus to configure the DLCI mapping for the PVC from the T1 network interface to the V.35 interface. CONNECTION (V35) > SETUP > DLCI MAPPING > MAP
Displays the DLCI Map number and is used as an index for multiple listings. The first map entry listed is 1, the next is 2, etc. All map numbers assigned will be sequential. CONNECTION (V35) > SETUP > DLCI MAPPING > ACTIVE
Enables FR/ATM mapping and data passing between the V.35 FRFx connection and the ATM PVC on the network interface. If set to NO, data will not pass from the network to the configured V.35 endpoint. By default, this field is set to YES to allow data to pass as soon as the connection is configured. CONNECTION (V35) > SETUP > SETUP > INTERFACE
The T1 interface is ATM[0.0] which represents the T1 physical and logical ports respectively. This is an identifier for the system to document the T1 network end of the logical link between the network port and the V.35 interface.
L2 PROTOCOL (T1 ATM–T1–ATM) > CONFIG > PVC CONFIG > SETUP (VOICE) Use these menus to configure the voice parameters for this logical connection from the T1 interface to the DSX-1 of FXS port being used as a voice interface. These menus are only applicable when the CONNECTION parameter is set to VOICE.
134
© 2004 ADTRAN, Inc.
64203376L1-1B