1. Minimum of 35 transition in progress (TIP) bytes (*0111010). 2. Minimum of 35 LSC bytes: OCU (*1010101), CSU (*0110001). 3. Minimum of 100 loopback enable (LBE) bytes (*1010110). 4. Minimum of 32 far-end voice (FEV) bytes (*1011010). * denotes don’t care bit (either a 1 or a 0)
Upon receipt of an OCU latching loopback, the UBR1TE provides a bilateral loopback on the bearer channel that received the loopback sequence. The other bearer channel is not affected during this loopback. Upon receipt of a CSU latching loopback sequence in either B1 or B2 channels and the U-interface is in sync, the UBR1TE issues an EOC loopback request to the NT1 for the appropriate channel. If the U-interface is not in sync, the UBR1TE sends abnormal station (*0011110) in both B1 and B2 channels. For a UBR1TE in a CSU latching loopback, receipt of the 35 TIPs will release the test in progress, following the release code to a UBRITE in a CSU test, the UBR1TE issues a Return-To-Normal EOC message to the NT1/TA.
INTERFACE (UBR1TE) > TEST > B2 TEST Initiates a test on the first B channel (B1) of the ISDN circuit. Refer to Interface (UBR1TE) > Test > B1 Test on page 113 for more details on available tests.
64203376L1-1B
© 2004 ADTRAN, Inc.
115
Page 116
Section 4 User Interface Guide
Total Access 850 System Manual
L2 PROTOCOL (T1 TDM FIRMWARE) Use the L2 protocol menu to select the L2 protocol, configure the protocol specific parameters and view the status as shown in Figure 8. The following menus are for Total Access 850 systems using T1 TDM firmware.
Figure 8. L2 Protocol (T1 TDM) Menu
For convenience, the following heading notations identify the type of firmware and L2 protocol configured in the Total Access 850 system:
L2 Protocol (T1 TDM – T1 – PPP) Firmware and RCU type. (For example, T1 TDM, T1 ATM, SDSL.)
116
Interface type. (For example, T1, Ethernet, etc.)
© 2004 ADTRAN, Inc.
Configured Layer 2 protocol. (For example, PPP, FRE, Auto, etc.)
64203376L1-1B
Page 117
Total Access 850 System Manual
Section 4 User Interface Guide
L2 PROTOCOL (T1 TDM FIRMWARE) – T1 INTERFACE Configure the L2 Protocol parameters and view the status of the T1 interface using items from this menu.
L2 PROTOCOL (T1 TDM – T1) > PROTOCOL Configure the L2 protocol mode. Choices are PPP, FRE, HDLC, and AUTO (def). Selecting PPP configures the interface for Point-to-Point Protocol signaling on Layer 2. Selecting FRE configures the interface for frame relay signaling on Layer 2. Selecting HDLC configures the interface for generic High-Level Data Link Control signaling on Layer 2. Selecting AUTO enables the Auto-config feature.
L2 PROTOCOL (T1 TDM – T1) > PROTOCOL > PPP Point-to-Point Protocol (PPP) is an 8-bit serial protocol which allows a PC to connect as a TCP/IP host to a network through an asynchronous port. PPP is used for connection from a PC to an Internet Service Provider (ISP) for Internet access. PPP works over synchronous and asynchronous circuits. Router-to-router and host-to-network connections can be made via PPP. PPP includes error detections which Serial Line Internet Protocol (SLIP) and other protocols do not.
L2 PROTOCOL (T1 TDM – T1) > PROTOCOL > FRE Frame Relay is a switched data link layer protocol that handles multiple virtual circuits using High-Level Data Link Control (HDLC) encapsulation. Frame Relay uses statistical multiplexing as opposed to time-division-multiplexing to multiplex many logical connections over a single physical link. It contains a cyclical redundancy check (CRC) for detecting bad data, but leaves the error correction algorithms to be performed by higher protocol layers. Similarly, Frame Relay uses simple congestion notification. This notification in turn can alert higher-layer protocols to exercise flow control. These characteristics allow Frame Relay to provide a more flexible and efficient use of bandwidth.
L2 PROTOCOL (T1 TDM – T1) > PROTOCOL > HDLC HDLC (High-level Data Link Control) is a group of protocols or rules for transmitting data between two network points (point-to-point transmission). HDLC provides a low overhead system for transmitting data over Layer 2. IP packets are encapsulated into frames with an HDLC start and end flag. Generic HDLC protocol should be used when connecting with remote equipment using proprietary HDLC encapsulation methods.
L2 PROTOCOL (T1 TDM – T1) > PROTOCOL > AUTO Setting the L2 PROTOCOL to AUTO allows the unit to automatically detect the L2 PROTOCOL from the network.
The L2 PROTOCOL must be set to AUTO in order to use the Auto-config feature.
64203376L1-1B
© 2004 ADTRAN, Inc.
117
Page 118
Section 4 User Interface Guide
Total Access 850 System Manual
L2 PROTOCOL (T1 TDM FIRMWARE) – T1 INTERFACE > PPP Configure the L2 PROTOCOL parameters and view the status of the T1 interface using PPP protocol from this menu.
L2 PROTOCOL (T1 TDM–T1–PPP) > CONFIG Configure the L2 PROTOCOL parameters for the T1 interface using PPP protocol.
L2 PROTOCOL (T1 TDM–T1–PPP) > CONFIG > MODE Select the L2 PROTOCOL mode. Choices are ROUTE IP, BRIDGE ALL, and ROUTE IP/BRIDGE OTHER. The default is ROUTE IP.
L2 PROTOCOL (T1 TDM–T1–PPP) > CONFIG > AUTHENTICATION The AUTHENTICATION menu contains the required parameters for the authentication of the PPP peer and for being authenticated by the PPP peer. Authentication is applied between the unit and the PPP peer as described in the Authentication submenus.
L2 PROTOCOL (T1 TDM–T1–PPP) > CONFIG > AUTHENTICATION > TX METHOD This parameter specifies how the unit is to be authenticated by the PPP peer. There are four possible selections. Default is NONE. NONE
The connection will not allow the PPP peer to authenticate it
PAP, CHAP, OR EAP
The unit will ask for EAP during the first PPP LCP negotiation and allow the PPP peer to negotiate down to CHAP or PAP.
CHAP OR EAP
The unit will ask for EAP during the first PPP LCP negotiation and allow the PPP peer to negotiate down to CHAP but not PAP.
EAP ONLY
The unit will only allow EAP to be negotiated. If the PPP peer is not capable of doing EAP, then the connection will not succeed.
PAP ONLY
The unit will only allow PAP to be negotiated. If the PPP peer is not capable of doing PAP, then the connection will not succeed.
L2 PROTOCOL (T1 TDM–T1–PPP) > CONFIG > PPP Configure the PPP specific parameters such as MAX CONFIG, MAX TIMER, MAX FAILURE, and FORCE PEER IP ADDRESS from this menu.
L2 PROTOCOL (T1 TDM–T1–PPP) > CONFIG > PPP > MAX CONFIG This value is the number of unanswered configuration-requests that should be transmitted before resetting PPP negotiations. The possible values are 5, 10, 15 and 20 (def).
118
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 119
Total Access 850 System Manual
Section 4 User Interface Guide
L2 PROTOCOL (T1 TDM–T1–PPP) > CONFIG > PPP > MAX TIMER (SEC) This value is the numbers of seconds to wait between unanswered configuration-requests. The possible values are 1 SEC, 2 SECS, 3 SECS (def), 5 SECS and 10 SECS.
L2 PROTOCOL (T1 TDM–T1–PPP) > CONFIG > PPP > MAX FAILURE Due to the nature of PPP, configuration options may not be agreed upon between two PPP peers. This value is the number of configuration-naks that should occur before an option is configuration-rejected. The possible values are 5 (def), 10, 15, and 20.
L2 PROTOCOL (T1 TDM–T1–PPP) > CONFIG > PPP > KEEPALIVE PERIOD This option allow the user to generate PPP keepalive packets that can be sent one every 1 minute, 2 minutes or every 5 minutes. A value of 0 (def) disables the PPP keepalive packet generating feature.
L2 PROTOCOL (T1 TDM–T1–PPP) > CONFIG > PPP > FORCE PEER IP ADDRESS This option forces the PPP to negotiate the IP address entered instead of allowing the IP address to be assigned by the remote end.
L2 PROTOCOL (T1 TDM–T1–PPP) > CONFIG > PPP > SEND IDENTIFICATION When enabled, this option enables the Total Access 850 to send the system identification code in response to a configure acknowledgement from the peer equipment. For most peer routers this option should be configured as YES. If set to NO, the Total Access 850 will accommodate peer routers that do not correctly respond to the identification code.
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS View the L2 PROTOCOL status for the T1 interface using the PPP protocol.
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS > LCP Link Control Protocol. Reflects the LCP layer active.
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS > BCP Shows UP if PPP Bridge Control Protocol has negotiated successfully.
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS > IPCP Shows UP if PPP IP Control Protocol has negotiated successfully.
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS > UP TIME Displays how long the PPP session has been connected.
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS > TX PKTS Number of packets transmitted on the T1 interface.
64203376L1-1B
© 2004 ADTRAN, Inc.
119
Page 120
Section 4 User Interface Guide
Total Access 850 System Manual
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS > RX PKTS Number of packets received on the T1 interface.
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS > TX BYTES Number of bytes transmitted on the T1 interface.
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS > RX BYTES Number of bytes received on the T1 interface.
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS > CURRENT UTIL (b/s) Current utilization of the T1 interface bandwidth presented in bits per second.
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS > CURRENT UTIL (%) Current utilization of the T1 interface bandwidth presented in percentage format.
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS > AVERAGE UTIL (b/s) Average utilization of the T1 interface bandwidth (since the last stats reset) presented in bits per second.
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS > AVERAGE UTIL (%) Average utilization of the T1 interface bandwidth (since the last stats reset) presented in percentage format.
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS > TX PKTS Number of packets transmitted on the T1 interface
L2 PROTOCOL (T1 TDM–T1–PPP) > STATUS > CLEAR STATS Clears the PPP stats (returning the counters to 0) for the T1 interface.
120
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 121
Total Access 850 System Manual
Section 4 User Interface Guide
L2 PROTOCOL (T1 TDM FIRMWARE) – T1 INTERFACE > FRE PROTOCOL Configure the L2 PROTOCOL parameters and view the status of the T1 interface using Frame Relay protocol from this menu.
L2 PROTOCOL (T1 TDM–T1–FRE) > CONFIG Configure the L2 PROTOCOL parameters for the T1 interface using the Frame Relay protocol.
L2 PROTOCOL (T1 TDM–T1–FRE) > CONFIG > MAINTENANCE PROTOCOL The Frame Relay maintenance protocol is used on the WAN port. The maintenance protocol is used to send link status and virtual circuit information between Frame Relay switches and other devices (such as routers that communicate with them. Possible choices are as follows: ANNEX D (ANSI)
This ANSI standard ANSI T1.617-D and is the most commonly used in the United States.
ANNEX A (Q933A)
This is the CCITT European standard, ITU-T Q.933-A.
LMI
This was developed by a vendor consortium and is also known as the “Consortium” management interface specification. It is still used by some carriers in the United States.
STATIC (NO SIG)
This should be selected when there is no Frame Relay switch in the circuit. The DLCIs are assigned in the DLCI Mapping and must be the same for the device it will communicate with.
The default value is ANNEX D (ANSI).
L2 PROTOCOL (T1 TDM–T1–FRE) > CONFIG > POLLING FREQUENCY (5-30) This parameter is the interval that the unit polls the Frame Relay switch using the maintenance protocol selected. The unit is required to poll the Frame Relay switch periodically to determine whether the link is active. The value is in seconds and ranges from 5 to 30 seconds with a default of 10 SECONDS.
L2 PROTOCOL (T1 TDM–T1–FRE) > CONFIG > DLCI MAPPING This menu allows each DLCI to be mapped to a particular Frame Relay maintenance protocol. Each protocol parameter can be individually configured for each DLCI. By factory default, the DLCI map is empty. When empty and a maintenance protocol other than the static is used, the unit will poll the switch to determine which DLCIs are active. These active DLCIs will attempt to determine the IP addresses on the other end of the virtual circuit using Inverse ARP (IARP). If there is a response, the network learned will be added to the router tables and the virtual circuit will be treated as an unnumbered interface. Bridge connections are made using bridge group 1. When more than one DLCI mapping is listed, the unit will try to match the DLCIs learned from the Frame Relay switch with the DLCI values in the map. If there is a match, the protocols specified in the map are used. However, if an active DLCI is not in the list, the unit looks for an entry that has 0 in the DLCI field. This entry is considered the default entry to use when no
64203376L1-1B
© 2004 ADTRAN, Inc.
121
Page 122
Section 4 User Interface Guide
Total Access 850 System Manual match occurs. If this default entry is not present, the unit falls back to using IARP to determine the protocols to use with that particular virtual circuit. If a static maintenance protocol is used, at least one DLCI mapping must be specified. To insert a new profile, press the I key when over the Num column. A new inserted profile will always be set up with the default parameters. To copy parameters from an old profile to this newly inserted profile, use the copy (C) and paste (P) keys. Entire configuration trees can be copied with this method.
To delete an unused profile, use the D key when the cursor is over the number in the Num column. Once deleted, the profile is gone permanently.
L2 PROTOCOL (T1 TDM–T1–FRE) > CONFIG > DLCI MAPPING > NUM Displays the index number in the DLCI mapping table.
L2 PROTOCOL (T1 TDM–T1–FRE) > CONFIG > DLCI MAPPING > ACTIVE When this parameter is set to YES (def), the mapping is used to determine the protocols used. If set to NO, the unit will ignore the virtual circuit with this DLCI.
L2 PROTOCOL (T1 TDM–T1–FRE) > CONFIG > DLCI MAPPING INTERFACE Shows the user the physical and logical port associated with each DLCI. This is a read-only field.
L2 PROTOCOL (T1 TDM–T1–FRE) > CONFIG > DLCI MAPPING > DLCI This DLCI (Data Link Connection Identifier) number identifies the virtual circuit being configured.
L2 PROTOCOL (T1 TDM–T1–FRE) > CONFIG > DLCI MAPPING > MODE The mode identifies how the data will be forwarded. The choices are: ROUTE IP (def)
All IP data for this DLCI will be routed.
BRIDGE ALL
All data for this DLCI will be bridged.
ROUTE UIP/BRIDGE OTHER
All IP data will be routed. All other data will be bridged.
L2 PROTOCOL (T1 TDM–T1–FRE) > CONFIG > DLCI MAPPING > BECN TIMEOUT (MSEC) This value is expressed in milliseconds and represents the amount of time the unit will stop transmitting over a PVC which received a packet with the BECN bit set. Range is 50-5000 msec; the default is 50 MILLLISECONDS.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS View the L2 protocol status for the T1 interface using the Frame Relay protocol.
122
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 123
Total Access 850 System Manual
Section 4 User Interface Guide
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT View the Frame Relay statistics on the WAN port.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > PORT INDEX Integer used for identifying DLCIs on an interface. A single DLCI will always be port index 0. Subsequent DLCIs will have incrementing port indices.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > SIGNAL STATE Displays “up” when the unit is communicating with the Frame Relay switch; otherwise displays “down”.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > TX FRAMES Total frames transmitted out the WAN port.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > RX FRAMES Total frames received from the WAN port.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > TX BYTES Total bytes transmitted out the WAN port.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > RX BYTES Total bytes received on the WAN port.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > CURRENT UTIL (b/s) Current utilization of the T1 interface bandwidth presented in bits per second.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > CURRENT UTIL (%) Current utilization of the T1 interface bandwidth presented in percentage format.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > AVERAGE UTIL (b/s) Average utilization of the T1 interface bandwidth (since the last stats reset) presented in bits per second.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > AVERAGE UTIL (%) Average utilization of the T1 interface bandwidth (since the last stats reset) presented in percentage format.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > FULL STATUS TX FRAMES Number of full status frames transmitted out the WAN port.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > FULL STATUS RX FRAMES Number of full status frames received on the WAN port
64203376L1-1B
© 2004 ADTRAN, Inc.
123
Page 124
Section 4 User Interface Guide
Total Access 850 System Manual
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > LINK INTEGRITY STATUS TX FRAMES Number of Link-Integrity (LI) only frames transmitted out the WAN port.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > LINK INTEGRITY STATUS RX FRAMES Number of LI only frames received on the WAN port.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > DROP UNKNOWN DLCI Number of frames received that were not associated with any known PVC.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > DROP INVALID DLCI Number of frames received that had illegal DLCIs.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PORT > CLEAR STATS Selecting this activator will clear the port Frame Relay Statistics.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PVC(S) View the Frame Relay status on a per PVC basis.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PVC(S) > DLCI The DLCI number identifies the virtual circuit being monitored.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PVC(S) > STATE The state of the virtual circuit: INACTIVE
The circuit exists but has been deactivated by the Frame Relay switch.
EXISTS
The circuit exists at this point and should be activated soon.
ACTIVE
The circuit is fully active.
OFF
The circuit has been turned off by the DLCI mapping active selection.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PVC(S) > TX FRAMES Number of Frame Relay packets that have been transmitted via this DLCI.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PVC(S) > RX FRAMES Number of Frame Relay packets that have been received via this DLCI.
L2 PROTOCOL (T1 TDM–T1–FRE) > STATUS > PVC(S) > TX BYTES Number of Frame Relay bytes that have been transmitted via this DLCI.