Page 105

Total Access 850 System Manual

Section 4 User Interface Guide

INTERFACES (FXS) > CONFIG > TANDEM ANSWER SUPERVISION Causes the polarity of tip and ring to be reversed when the far-end answers. Can be enabled or disabled. Default is DISABLE.

INTERFACES (FXS) > CONFIG > TANDEM > DNIS OPTIONS This parameter is used in conjunction with DNIS DELAY. Choices are DISABLE, ENABLE, and ENABLE W/ NO ANSWER WINK. Default is DISABLE.

INTERFACES (FXS) > CONFIG > TANDEM > DNIS DELAY Sets the amount of time the voice module waits after it receives a wink before forwarding a DNIS digit if DNIS OPTIONS is set to ENABLE. Choices are 0.5 SEC, 1.0 SEC, 2.0 SEC, 2.5 SEC, 3.0 SEC, and 5.0 SEC. Default is 3.0 SEC.

INTERFACES (FXS) > CONFIG > TANDEM > FWD DISC DELAY In Tandem mode, FWD DISC DELAY defines the time battery is actually removed/reversed once the forward disconnect is received. Choices are 250 MSEC, 500 MSEC, 750 MSEC, 1 SEC, and 2 SEC. Default is 1 SEC.

INTERFACES (FXS) > CONFIG > TANDEM > FWD DISC BATTERY In Tandem mode, selects whether battery is to be removed or reversed during forward disconnect. Choices are REMOVE and REVERSE. Default is REMOVE.

INTERFACES (FXS) > STATUS Displays the status of the FXS signal bits.

INTERFACES (FXS) > STATUS > SLOT Displays the slot number associated with the installed FXS Module.

INTERFACES (FXS) > STATUS > PORT Displays the port number.

INTERFACES (FXS) > STATUS > TA SIG This parameter displays the status of the Transmit A signal bit. The high/low status is indicated by a 0 or 1.

INTERFACES (FXS) > STATUS > TB SIG This parameter displays the status of the Transmit B signal bit. The high/low status is indicated by a 0 or 1.

INTERFACES (FXS) > STATUS > RA SIG This parameter displays the status of the Receive A signal bit. The high/low status is indicated by a 0 or 1.

INTERFACES (FXS) > STATUS > RB SIG This parameter displays the status of the Receive B signal bit. The high/low status is indicated by a 0 or 1.

64203376L1-1B

© 2004 ADTRAN, Inc.

105

Page 106

Section 4 User Interface Guide

Total Access 850 System Manual

INTERFACES (FXS) > TEST Activate tests and monitor test status on a per port basis from this menu.

INTERFACES (FXS) > TEST > SLOT Displays the slot number for the installed FXS Module.

INTERFACES (FXS) > TEST > PORT Displays the port number.

INTERFACES (FXS) > TEST > TEST Choices are given below. Default is NONE. NONE

Indicates that no test is currently active.

DIGITAL NETWORK LPBK

Used to loop back DS0 data coming from the network for each channel. Received data is latched in on the appropriate receive time slot on the receive bus. This data is then placed on the transmit bus in the unit’s transmit time slot.

NETWORK ON HOOK TEST

Used to test signaling sent to the network by the unit. On-hook signaling is sent to the network. The customer loop is forced on-hook while this test is active.

NETWORK OFF HOOK TEST

Used to test signaling sent to the network by the unit. Off-hook signaling is sent to the network. The customer loop is forced off-hook while this test is active.

1 KHZ TONE-NEAR END For Near End, the 2-wire side sends out a 1 kHz tone to verify talk path. 1 KHZ TONE-FAR END

For Far End, the tone side is sent out across the Network and can be heard if monitoring on the T1 as well as off of the Far End 2-wire side. This verifies talk path.

CUSTOMER RING TEST

The customer ring test will activate the unit’s ring relay in a 2-on /4-off cadence, providing ringing to the customer loop.

INTERFACES (FXS) > TEST > TEST STATUS This option indicates whether a test is in progress.

106

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 107

Total Access 850 System Manual

Section 4 User Interface Guide

INTERFACES (FXO) View the FXO interface status and configure the FXO parameters from this menu.

INTERFACES (FXO) > CONFIG Configure the FXO mode, line impedance, and Tandem parameters from this menu.

INTERFACES (FXO) > CONFIG > SLOT Displays the slot number of the installed FXO Module.

INTERFACES (FXO) > CONFIG > PORT Indicates the port on which the FXO is installed.

INTERFACES (FXO) > CONFIG > MODE Choices are given below. Default is LOOP START. This mode must match the network configuration and/or how each port is being used. Each port on the FXO Module is independent and should be set accordingly.

LOOP START

Sets the port to use FXO loop start signaling on the T-span and loop start supervision on the analog 2-wire interface.

GROUND START

Sets the port to use FXO ground start signaling on the T-span and ground start supervision on the analog 2-wire interface.

DPO

Sets the port to use Dial Pulse signaling to originate dialed numbers.

MODIFIED DPT

Sets the port to use DPT signaling on the interface. In DPT mode, digits are transmitted out the FXO interface to the user equipment. DPT mode is one-way operation only (outbound calls only).

INTERFACES (FXO) > CONFIG > TX (dB) Sets the TX direction level points. This signal will change the volume of the voice. TX (dB) is the signal that is transmitted out the T1, with 0 dB being the strongest. If the volume is too loud across the T1, this number should be increased. A higher number indicates more attenuation which equals lower volume. The value entered must be less than 10 dB. Default is 0.0 dB.

INTERFACES (FXO) > CONFIG > RX (dB) Sets the RX direction level points. This signal will change the volume of the voice. A higher number indicates more attenuation which equals lower volume. The value entered must be less than 10 dB. Default is 0.0 dB.

64203376L1-1B

© 2004 ADTRAN, Inc.

107

Page 108

Section 4 User Interface Guide

Total Access 850 System Manual

INTERFACES (FXO) > CONFIG > SVC MODE Indicates whether the module is IN SERVICE or OUT OF SVC. This does not indicate whether the port has been mapped. For proper operation, the port must be mapped using the DS0 MAPS menu. Default is IN SERVICE.

INTERFACES (FXO) > STATUS Displays the status of the FXO signal bits.

INTERFACES (FXO) > STATUS > SLOT Displays the slot number for the installed FXO Module.

INTERFACES (FXO) > STATUS > PORT Displays the port number.

INTERFACES (FXO) > STATUS > TA SIG This parameter displays the status of the Transmit A signal bit. The high/low status is indicated by a 0 or 1.

INTERFACES (FXO) > STATUS > TB SIG This parameter displays the status of the Transmit B signal bit. The high/low status is indicated by a 0 or 1.

INTERFACES (FXO) > STATUS > RA SIG This parameter displays the status of the Receive A signal bit. The high/low status is indicated by a 0 or 1.

INTERFACES (FXO) > STATUS > RB SIG This parameter displays the status of the Receive B signal bit. The high/low status is indicated by a 0 or 1.

INTERFACES (FXO) > TEST Activate tests and monitor test status on a per port basis from this menu.

INTERFACES (FXO) > TEST > SLOT Displays the slot number for the installed FXO Module.

INTERFACES (FXO) > TEST > PORT Displays the port number.

108

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 109

Total Access 850 System Manual

Section 4 User Interface Guide

INTERFACES (FXO) > TEST > TEST Choices are given below. Default is NONE. NONE

Indicates that no test is currently active.

DIGITAL NETWORK LPBK

Used to loop back DS0 data coming from the network for each channel. Received data is latched in on the appropriate receive time slot on the receive bus. This data is then placed on the transmit bus in the unit’s transmit time slot.

NETWORK ON HOOK TEST

Used to test signaling sent to the network by the unit. On-hook signaling is sent to the network. The customer loop is forced on-hook while this test is active.

NETWORK OFF HOOK TEST

Used to test signaling sent to the network by the unit. Off-hook signaling is sent to the network. The customer loop is forced off-hook while this test is active.

1004 HZ - 0DCBM0 TONE GEN

Used to verify talk path by sending out 1004 Hz tone to test across the network. Monitoring of the T1 as well as the Far-End 2-wire side verifies the talk path if the tone is heard.

INTERFACES (FXO) > TEST > TEST STATUS This option indicates whether a test is in progress.

INTERFACES (DSX-1 MODULE) View the DSX-1 Module interface status and configure the DSX-1 Module parameters from this menu.

INTERFACES (DSX-1) > CONFIG Configures the DSX-1 interface format and code from this menu.

INTERFACE (DSX-1) > CONFIG > SLOT Indicates the slot in which the DSX-1 Module is installed.

INTERFACE (DSX-1) > CONFIG > PORT Indicates the port on which the DXS is installed.

INTERFACE (DSX-1) > CONFIG > FORMAT This setting must match the frame format of the circuit to which the interface is connected. Choices are ESF and SF (D4). Extended Superframe (ESF) provides a non-disruptive means of full-time monitoring on the facility data link (FDL). The default is ESF.

64203376L1-1B

© 2004 ADTRAN, Inc.

109

Page 110

Section 4 User Interface Guide

Total Access 850 System Manual

INTERFACE (DSX-1) > CONFIG > LINE CODE This setting must match the line code of the circuit to which the interface is connected. Choices are B8ZS (bipolar with 8-zero substitution) and AMI (alternate mark inversion). The default is B8ZS.

INTERFACES (DSX-1) > STATUS Displays the DSX-1 interface status including performance data and alarm histories.

INTERFACES (DSX-1) > STATUS > ALARMS Displays current alarms and alarm history for the DSX-1 interface.

INTERFACES (DSX-1) > STATUS > ALARMS > CURRENT ALARMS Displays the current alarms on the DSX-1 interface. An asterisk in a field indicates that an alarm is active. LOS

Loss of Signal. No signal detected on port interface.

RED

Not able to frame data received on the port. Alternately referred to as Out of Frame (OOF).

YELLOW

Remote alarm indicator (RAI) being received on port.

BLUE

Receiving unframed all ones from the port alarm indicator signal (AIS).

INTERFACES (DSX-1) > STATUS > ALARMS > ALARM HISTORY Displays the alarm history for the T1 interface. An asterisk in a field indicates that an alarm has occurred on the T1 interface since the last clear history. Refer to Interfaces (DSX-1) > Status > Alarms > Current Alarms for more details on listed alarm conditions.

INTERFACES (DSX-1) > STATUS > ALARMS > CLEAR HISTORY Selecting this activator will clear the Alarm History for the T1 interface.

INTERFACES (DSX-1) > TEST These options are used to initiate local and remote loopback tests and display the test status.

INTERFACES (DSX-1) > TEST > SLOT Displays the slot number of the installed DSX-1 Module.

INTERFACES (DSX-1) > TEST > LOC LB Loopback of the local unit. Choices are NONE, LINE, AND PAYLOAD. LINE loopback loops all of the received data back toward the network. The transmitted data is the identical line code that was received, including any bipolar violations. PAYLOAD loopback is similar to line loopback except that the framing is extracted from the received data and then regenerated for the transmitted data. NONE disables the loopback test. Default is NONE.

INTERFACES (DSX CARD) > TEST > TEST STATUS Indicates whether a test is in progress. 110

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 111

Total Access 850 System Manual

Section 4 User Interface Guide

INTERFACES (UBR1TE MODULE) View the UBR1TE Module interface status and configure the UBR1TE Module parameters from this menu.

INTERFACES (UBR1TE) > CONFIG Configures the UBR1TE interface format and code from this menu.

INTERFACE (UBR1TE) > CONFIG > SLOT Indicates the slot in which the UBR1TE Module is installed.

INTERFACE (UBR1TE) > CONFIG > MODE Choices are LUNT, LUNT W/WAKEUP, and LULT. The U-BR1TE port should be configured to operate in the LULT mode if being operated in the Adjacent to Customer or Tandem Office Source positions (see Figure 7). The MODE should be set to LUNT if the port is operated in the Adjacent to Switch or Tandem Office

64203376L1-1B

© 2004 ADTRAN, Inc.

111

Page 112

Section 4 User Interface Guide

Total Access 850 System Manual

Sink positions. Default is LULT.

2-Wire

ISDN Switch

2-Wire

2-Wire

U-BR1TE Port

U-BR1TE Port L U N T

L U L T

T Carrier

TA 850

TA 850

Adjacent to Switch

Adjacent to Customer

U-BR1TE Port

U-BR1TE Port

L U N T

Customer NT1

U-BR1TE Port L U L T

T Carrier

2-Wire Loop

2-Wire

U-BR1TE Port

L U N T

L U L T

T Carrier

TA 850

TA 850

TA 850

TA 850

Adjacent to Switch

Tandem Office (Source)/U-Repeater

Tandem Office (Sink)

Adjacent to Customer

U-BR1TE Port

U-BR1TE Port

L U N T

L U L T

T Carrier

TA 850

TA 850

Adjacent to Switch

Tandem Office (Source)/U-Repeater

2-Wire Loop

2-Wire

RP

2-Wire Loop

Customer NT1

Customer NT1

U-Repeater

Figure 7. UBR1TE Network Configurations

INTERFACE (UBR1TE) > CONFIG > SERVICE Allows the user to select the ISDN channels transmitted over the T1 facility. Each channel requires one DS0 of the T1 in which to transmit and receive data. All switched applications will require the D channel. Choices are 2B+D, B1+D, B2+D, B1+B2, B1, B2, and D. Default is 2B+D.

The user must provision the proper number of consecutive DS0s of the T1 facility for proper operation.

INTERFACE (UBR1TE) > CONFIG > ZERO BYTE SUB For proper operation, the ZBS (zero byte substitution) for two U-BR1TE ports connected by a T1 facility must be the same value. The ENABLE parameter for ZBS must be selected if the T1 is using AMI line coding. If the T1 facility is using B8ZS line coding, the DISABLE parameter may be chosen. Default is ENABLED. 112

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 113

Total Access 850 System Manual

Section 4 User Interface Guide

INTERFACE (UBR1TE) > CONFIG > SEALING CURRENT DC sealing current is only applicable if the mode is LULT. Sealing current should be present for Adjacent-to-Customer applications. Default is ENABLED.

INTERFACE (UBR1TE) > STATUS View the interface status information for the UBR1TE Module.

INTERFACE (UBR1TE) > STATUS > SLOT Displays the slot number for the installed UBR1TE Module.

INTERFACE (UBR1TE) > STATUS > ACT BIT This status field indicates whether an NT1 is communicating with the ISDN switch.

INTERFACE (UBR1TE) > STATUS > LOOP Displays synchronization between the UBR1TE card and the NT1 on the loop side of the card. Sync displays YES or NO.

INTERFACE (UBR1TE) > STATUS > CARRIER Displays synchronization between the ISDN switch and the UBR1TE card on the T1 network side. Sync displays YES or NO.

INTERFACE (UBR1TE) > STATUS > RX LOOP CRC ERROR Indicates a CRC error has been received on the loop side of the card (indicating it came from the NT1).

INTERFACE (UBR1TE) > STATUS > RX CARRIER CRC ERROR Indicates a CRC error has been received on the carrier side of the card (indicating it came from the ISDN switch).

INTERFACE (UBR1TE) > STATUS > TEST STATUS Indicates whether a test is in progress.

INTERFACE (UBR1TE) > TEST These options are used to initiate tests.

INTERFACE (UBR1TE) > TEST > SLOT Displays the slot number for the installed UBR1TE Module.

INTERFACE (UBR1TE) > TEST > B1 TEST Initiates a test on the first B channel (B1) of the ISDN circuit. The following tests are available: NONE

64203376L1-1B

No active test.

© 2004 ADTRAN, Inc.

113

Page 114

Section 4 User Interface Guide

ADDR1 (LOCAL LPBK) ADDR2 ADDR3 ADDR4 NT1

Total Access 850 System Manual

Loopbacks in the Network-to-Customer direction initiate from either the ISDN switch or the test menus. If a DS0 digital test set is connected to the bantam connector on the front of the module, data from the test set provides the 64 kbps test pattern used in testing B1 or B2. If no test set is connected, an internally generated 2074 test pattern is used. When initiating loopbacks from the UBR1TE Module, the downstream direction is automatically selected based on the card position in the network. These tests are only valid for the Adjacent-to-Customer circuit position. Use ADDR2 to test an ADTRAN U-Repeater deployed from the UBR1TE.

TX INTO CARRIER

A point-to-point (straight-away) test initiated toward the T1 carrier interface. The internal 2047 test pattern generator is used to verify the performance of the bearer channel. This test is valid for all network configurations.

TX INTO LOOP

A point-to-point (straight-away) test initiated toward the U-interface. The internal 2047 test pattern generator is used to verify the performance of the bearer channel. This test is valid for all network configurations.

BILATERAL LPBK

Loops toward both the U-interface and the T1 carrier network.

LEASED MODE TESTING (INITIATED BY THE NETWORK; NOT A MENU OPTION)

For leased mode applications, the D channel is typically disabled on the UBR1TE. Without the D channel, standard ISDN loopbacks by way of the EOC are not available across the T1 carrier system. For this situation, the UBR1TE responds to independent network-issued OCU and CSU latching loopback sequences for B1 and B2, when configured as Adjacent-to-Customer. Upon receipt of an OCU latching loopback sequence, the UBR1TE initiates a bilateral loopback for the B channel under test. Upon receipt of a CSU latching loopback sequence, and provided the U-interface is terminated by an NT1/TA, the UBR1TE issues an EOC NT1 loopback for the appropriate B channel. In both tests of the OCU and the CSU loopbacks, the other B channel is not affected. The UBRTE supports simultaneously testing both B channels. The OCU and CSU latching loopbacks are enabled by the following:

114