Page 95

Total Access 850 System Manual

Section 4 User Interface Guide

INTERFACES (T1) > CONFIG > EQUALIZATION Select the line build out for the T1 interface. These are attenuation settings. 0 dB is the strongest signal, and the other settings make the T1 transmit signal weaker. The setting of this field depends on whether the circuit is provisioned for DS1 by the telephone company. The choices are 0 dB, -7.5 dB, -15 dB, -22 dB. Default is 0 dB.

INTERFACES (T1) > CONFIG > CSU LPBK Choices are ENABLE, DISABLE, and DISABLE ALL. Default is ENABLE. This allows the unit to either respond or not respond to CSU loop up commands.

INTERFACES (T1) > CONFIG > RX SENSITIVITY Configures the sensitivity of the T1 receiver for this interface to provide increased sensitivity for long-run T1 applications. Choices are AUTO, -36 dB, and -10 dB.

INTERFACES (T1) > STATUS Displays the T1 status including performance data and alarm histories.

INTERFACES (T1) > STATUS > PERFORMANCE Displays the T1 performance data.

INTERFACES (T1) > STATUS > PERFORMANCE > CURRENT AND TOTALS Provides current (15-minute window) status on key performance measures as specified in ANSI T1.403 and AT&T TR 54016 for each of the T1 ports as well as historical statistical totals.

INTERFACES (T1) > STATUS > PERFORMANCE > CURRENT AND TOTALS > INTERVAL Identifies the interval (CURRENT or TOTAL) for the listed performance statistics.

INTERFACES (T1) > STATUS > PERFORMANCE > CURRENT AND TOTALS > ES ES (Errored Second) - For ESF mode, an errored second is defined as a second with one or more Path

Code Violations (PCVs), or one or more Out of Frame (OOF) defects, or one or more Controlled Slip events, or a detected AIS (blue alarm) defect. For D4 (SF) mode, the presence of Bipolar Violations (BPVs) also triggers an errored second.

INTERFACES (T1) > STATUS > PERFORMANCE > CURRENT AND TOTALS > SES SES (Severely Errored Second) - For ESF mode, an SES is a second with 320 or more PCVs, or one or more OOF defects, or a detected AIS defect. For D4 (SF) mode, an SES is a second with one or more Framing Error events, or an OOF defect, or at least 1544 Line Code Violations or more.

INTERFACES (T1) > STATUS > PERFORMANCE > CURRENT AND TOTALS > SEF SEF (Severely Errored Frame) - An SEF condition occurs when 2 out of 6 consecutive frame bits are in error.

64203376L1-1B

© 2004 ADTRAN, Inc.

95

Page 96

Section 4 User Interface Guide

Total Access 850 System Manual

INTERFACES (T1) > STATUS > PERFORMANCE > CURRENT AND TOTALS > FS FS (Frame Slip) - A frame slip is defined as one or more frame bit errors in a one-second interval.

INTERFACES (T1) > STATUS > PERFORMANCE > CURRENT AND TOTALS > LCV LCV (Line Code Violation) - A Line Code Violation is defined as a Bipolar Violation (BPV), not including the B8ZS code word if B8ZS is employed. The number displayed is LCV events, which is defined as one or more BPVs in a one-second interval.

INTERFACES (T1) > STATUS > PERFORMANCE > CURRENT AND TOTALS > SLP SLP (Slip Error Event) - This occurs when a received frame is either repeated or deleted. A SLP error indicates a timing problem.

INTERFACES (T1) > STATUS > PERFORMANCE > CURRENT AND TOTALS > UAS UAS (Unavailable Seconds) - When 10 consecutive SESs have been logged, the unit is declared in an unavailable state, the 10 SESs are cleared, and the Unavailable Seconds count begins to increment starting with 10. The unavailable state is cleared when 10 consecutive non-SES seconds have occurred.

INTERFACES (T1) > STATUS > PERFORMANCE > EXTENDED Provides statistics for the last 24 hours (in 15 minute windows) on key performance measures as specified in ANSI T1.403 and AT&T TR 54016 for each of the T1 ports. Refer to the CURRENT AND TOTALS performance information for more details on listed statistics.

INTERFACES (T1) > STATUS > PERFORMANCE > CLEAR CURRENT DATA Clears all statistics collected in the CURRENT AND TOTALS statistics table.

INTERFACES (T1) > STATUS > PERFORMANCE > CLEAR ALL DATA Clears all statistics collected in the CURRENT AND TOTALS and the EXTENDED 24 hour statistics tables.

INTERFACES (T1) > STATUS > ALARMS Displays current alarms and alarm history for T1 interface.

INTERFACES (T1) > STATUS > ALARMS > CURRENT ALARMS Displays the current alarms on the T1 interface. An asterisk in a field indicates that an alarm is active.

96

LOS

Loss of Signal. No signal detected on port interface.

RED

Not able to frame data received on the port. Alternately referred to as Out of Frame (OOF).

YELLOW

Remote alarm indicator (RAI) being received on port.

BLUE

Receiving unframed all ones from the port alarm indicator signal (AIS).

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 97

Total Access 850 System Manual

Section 4 User Interface Guide

INTERFACES (T1) > STATUS > ALARMS > ALARM HISTORY Displays the alarm history for the T1 interface. An asterisk in a field indicates that an alarm has occurred on the T1 interface since the last clear history. Refer to Interfaces (T1) > Status > Alarms > Current Alarms on page 96 for more details on listed alarm conditions.

INTERFACES (T1) > STATUS > ALARMS > CLEAR HISTORY Selecting this activator will clear the Alarm History for the T1 interface.

INTERFACES (T1) > STATUS > RX LEVEL Displays the level (in dB) of the received T1 signal on the interface.

INTERFACES (T1) > TEST These options are used to initiate local and remote loopback tests and display the test status.

INTERFACES (T1) > TEST > LOC LB Loopback of the local unit. Choices are NONE, LINE, and PAYLOAD. LINE loopback loops all of the received data back toward the network. The transmitted data is the identical line code that was received, including any bipolar violations. PAYLOAD loopback is similar to line loopback except that the framing is extracted from the received data and then regenerated for the transmitted data. NONE disables the loopback test. Default is NONE.

INTERFACES (T1) > TEST > REM LB Loopback of remote unit. Choices are NONE, LINE, and PAYLOAD. LINE loopback loops all of the received data back toward the network. The transmitted data is the identical line code that was received, including any bipolar violations. PAYLOAD loopback is similar to line loopback except that the framing is extracted from the received data and then regenerated for the transmitted data. NONE disables the loopback test. Default is NONE.

INTERFACES (T1) > TEST > TEST STATUS Indicates whether a test is in progress.

64203376L1-1B

© 2004 ADTRAN, Inc.

97

Page 98

Section 4 User Interface Guide

Total Access 850 System Manual

INTERFACES (DSX) View the integrated DSX interface status and configure T1 parameters from this menu.

INTERFACES (DSX) > CONFIG Configure the various DSX parameters and enable/disable loopbacks from this menu.

INTERFACES (DSX) > CONFIG > FORMAT This sets the frame format for the DSX interface. The setting must match the frame format of the circuit to which the interface is connected. Choices are ESF, SF (D4). Extended Superframe (ESF) provides a non-disruptive means of full-time monitoring on the facility datalink (FDL). Default is ESF.

INTERFACES (DSX) > CONFIG > LINE CODE This sets the line code for the DSX interface. The setting must match the line code of the circuit to which the interface is connected. Choices are B8ZS (bipolar with 8-zero substitution) and AMI (alternate mark inversion). Default is B8ZS.

INTERFACES (DSX) > CONFIG > EQUALIZATION Select the line build out for the DSX1 interface. The choices are 0 dB, 266 FT, 399 FT, 533 FT, 655 FT, or -7.5 dB. Default is 0 dB. The 7.5 dB setting is provided for terminal equipment that has trouble recovering a full 0dB level signal (typically one with a DS1 long haul line interface).

INTERFACES (DSX) > CONFIG > CSU LPBK Choices are ENABLE, DISABLE, and DISABLE ALL. Default is ENABLE. This allows the unit to either respond or not respond to CSU loop up commands.

INTERFACES (DSX) > CONFIG > RX SENSITIVITY Configures the sensitivity of the T1 receiver for this interface to provide increased sensitivity for long-run T1 applications. Choices are AUTO, -36 dB, and -10 dB.

INTERFACES (DSX) > STATUS Displays the T1 status including performance data and alarm histories.

INTERFACES (DSX) > STATUS > PERFORMANCE Displays the T1 performance data.

INTERFACES (DSX) > STATUS > PERFORMANCE > CURRENT AND TOTALS Provides current (15-minute window) status on key performance measures as specified in ANSI T1.403 and AT&T TR 54016 as well as historical statistical totals for the integrated DSX port.

INTERFACES (DSX) > STATUS > PERFORMANCE > CURRENT AND TOTALS > INTERVAL Identifies the interval (CURRENT or TOTAL) for the listed performance statistics.

98

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 99

Total Access 850 System Manual

Section 4 User Interface Guide

INTERFACES (DSX) > STATUS > PERFORMANCE > CURRENT AND TOTALS > ES ES (Errored Second) - For ESF mode, an errored second is defined as a second with one or more Path

Code Violations (PCVs), or one or more Out of Frame (OOF) defects, or one or more Controlled Slip events, or a detected AIS (blue alarm) defect. For D4 (SF) mode, the presence of Bipolar Violations (BPVs) also triggers an errored second.

INTERFACES (DSX) > STATUS > PERFORMANCE > CURRENT AND TOTALS > SES SES (Severely Errored Second) - For ESF mode, an SES is a second with 320 or more PCVs, or one or more OOF defects, or a detected AIS defect. For D4 (SF) mode, an SES is a second with one or more Framing Error events, or an OOF defect, or at least 1544 Line Code Violations or more.

INTERFACES (DSX) > STATUS > PERFORMANCE > CURRENT AND TOTALS > SEF SEF (Severely Errored Frame) - An SEF condition occurs when 2 out of 6 consecutive frame bits are in error.

INTERFACES (DSX) > STATUS > PERFORMANCE > CURRENT AND TOTALS > FS FS (Frame Slip) - A frame slip is defined as one or more frame bit errors in a one-second interval.

INTERFACES (DSX) > STATUS > PERFORMANCE > CURRENT AND TOTALS > LCV LCV (Line Code Violation) - A Line Code Violation is defined as a Bipolar Violation (BPV), not including the B8ZS code word if B8ZS is employed. The number displayed is LCV events, which is defined as one or more BPVs in a one-second interval.

INTERFACES (DSX) > STATUS > PERFORMANCE > CURRENT AND TOTALS > SLP SLP (Slip Error Event) - This occurs when a received frame is either repeated or deleted. A SLP error indicates a timing problem.

INTERFACES (DSX) > STATUS > PERFORMANCE > CURRENT AND TOTALS > UAS UAS (Unavailable Seconds) - When 10 consecutive SESs have been logged, the unit is declared in an unavailable state, the 10 SESs are cleared, and the Unavailable Seconds count begins to increment starting with 10. The unavailable state is cleared when 10 consecutive non-SES seconds have occurred.

INTERFACES (DSX) > STATUS > PERFORMANCE > EXTENDED Provides statistics for the last 24 hours (in 15 minute windows) on key performance measures as specified in ANSI T1.403 and AT&T TR 54016 for each of the T1 ports. Refer to the CURRENT AND TOTALS performance information for more details on listed statistics.

INTERFACES (DSX) > STATUS > PERFORMANCE > CLEAR CURRENT DATA Clears all statistics collected in the CURRENT AND TOTALS statistics table.

INTERFACES (DSX) > STATUS > PERFORMANCE > CLEAR ALL DATA Clears all statistics collected in the CURRENT AND TOTALS and the EXTENDED 24 hour statistics tables.

64203376L1-1B

© 2004 ADTRAN, Inc.

99

Page 100

Section 4 User Interface Guide

Total Access 850 System Manual

INTERFACES (DSX) > STATUS > ALARMS Displays current alarms and alarm history for the integrated DSX interface.

INTERFACES (DSX) > STATUS > ALARMS > CURRENT ALARMS Displays the current alarms on the T1 interface. An asterisk in a field indicates that an alarm is active. LOS

Loss of Signal. No signal detected on port interface.

RED

Not able to frame data received on the port. Alternately referred to as Out of Frame (OOF).

YELLOW

Remote alarm indicator (RAI) being received on port.

BLUE

Receiving unframed all ones from the port alarm indicator signal (AIS).

INTERFACES (DSX) > STATUS > ALARMS > ALARM HISTORY Displays the alarm history for the T1 interface. An asterisk in a field indicates that an alarm has occurred on the T1 interface since the last clear history. Refer to Interfaces (DSX) > Status > Alarms > Current Alarms for more details on listed alarm conditions.

INTERFACES (DSX) > STATUS > ALARMS > CLEAR HISTORY Selecting this activator will clear the Alarm History for the integrated DSX interface.

INTERFACES (DSX) > STATUS > RX LEVEL Displays the level (in dB) of the received T1 signal on the interface.

INTERFACES (DSX) > TEST These options are used to initiate local and remote loopback tests and display the test status.

INTERFACES (DSX) > TEST > LOC LB Loopback of the local unit. Choices are NONE, LINE, AND PAYLOAD. LINE loopback loops all of the received data back toward the network. The transmitted data is the identical line code that was received, including any bipolar violations. PAYLOAD loopback is similar to line loopback except that the framing is extracted from the received data and then regenerated for the transmitted data. NONE disables the loopback test. Default is NONE.

INTERFACES (DSX) > TEST > REM LB Loopback of remote unit. Choices are NONE, LINE, and PAYLOAD. LINE loopback loops all of the received data back toward the network. The transmitted data is the identical line code that was received, including any bipolar violations. PAYLOAD loopback is similar to line loopback except that the framing is extracted from the received data and then regenerated for the transmitted data. NONE disables the loopback test. Default is NONE.

INTERFACES (DSX) > TEST > TEST STATUS Indicates whether a test is in progress. 100

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 101

Total Access 850 System Manual

Section 4 User Interface Guide

INTERFACES (ETH) View the Ethernet interface status and configure the Ethernet parameters from this menu.

INTERFACES (ETH) > CONFIG Configure the various Ethernet parameters from this menu.

INTERFACES (ETH) > CONFIG > AUTO NEGOTIATION The Total Access 850 has the capability of auto negotiating the rate and duplex of the connected Ethernet link. Additionally, when this parameter is set to OFF, the rate and duplex are set manually. Auto Negotiation is only available when using a 3rd Generation RCU with the Total Access 850 system.

INTERFACES (ETH) > CONFIG > DATE RATE Defines the Ethernet interface as 100BASET or 10BASET. Data Rate configuration is only available when using a 3rd Generation RCU with the Total Access 850 system.

INTERFACES (ETH) > CONFIG > DUPLEX TYPE Defines operation on the Ethernet interface as FULL DUPLEX or HALF DUPLEX. Duplex Type configuration is only available when using a 3rd Generation RCU with the Total Access 850 system.

INTERFACES (ETH) > STATUS Displays the Ethernet status information.

INTERFACES (ETH) > STATUS > MAC ADDRESS (Read only) Displays the unique MAC address programmed at ADTRAN.

INTERFACES (ETH) > STATUS > DATA LINK Displays the current status of the Ethernet link as either UP or DOWN. If there is an active Ethernet link, the status displays UP. Data Link status information is only available when using a 3rd Generation RCU with the Total Access 850 system.

INTERFACES (ETH) > STATUS > DATA RATE Displays the Ethernet interface current rate of operation (as defined by the DATA RATE configuration parameter).

INTERFACES (ETH) > STATUS > DUPLEX TYPE Displays the Ethernet interface current mode of operation (as defined by the DUPLEX TYPE configuration parameter). Duplex Type status information is only available when using a 3rd Generation RCU with the Total Access 850 system.

64203376L1-1B

© 2004 ADTRAN, Inc.

101

Page 102

Section 4 User Interface Guide

Total Access 850 System Manual

INTERFACES (V35) View the V.35 interface status and configure the V.35 parameters from this menu.

INTERFACES (V35) > CONFIG Configure the DTE leads from this menu.

INTERFACES (V35) > CONFIG > CTS Sets the control characteristic of the clear-to-send lead. Choices are NORMAL (follows RTS) or FORCE ON. Default is NORMAL.

INTERFACES (V35) > CONFIG > DCD Sets the control characteristic of the carrier detect lead. Choices are NORMAL (follows valid signal on the network interface) or FORCE ON. Default is NORMAL.

INTERFACES (V35) > CONFIG > DSR Sets the control characteristic of the data set ready lead. Choices are NORMAL (follows DTR) or FORCE ON. Default is NORMAL.

INTERFACES (V35) > STATUS View the status of the DTE leads from this menu.

INTERFACES (V35) > STATUS > RTS View the status of Request to Send (RTS) lead. Possibilities are OFF or ON.

INTERFACES (V35) > STATUS > DTR View the status of the Data Terminal Read (DTR) lead. Possibilities are OFF and ON.

INTERFACES (V35) > TEST These options are used to loopback tests.

INTERFACES (V35) > TEST > LOOPBACK Enables a local loopback of the V.35 interface. All data received on the V.35 interface is transmitted back out the interface.

102

© 2004 ADTRAN, Inc.

64203376L1-1B

Page 103

Total Access 850 System Manual

Section 4 User Interface Guide

INTERFACES (FXS) View the FXS interface status and configure the FXS parameters from this menu.

INTERFACES (FXS) > CONFIG Configure the FXS mode, line impedance and Tandem parameters from this menu.

INTERFACES (FXS) > CONFIG > SLOT Displays the slot number associated with the installed FXS Module.

INTERFACES (FXS) > CONFIG > PORT Indicates the port on which the FXS is installed.

INTERFACES (FXS) > CONFIG > MODE Choices are given below. Default is LOOP START. This mode must match the network configuration and/or how each port is being used. Each port on the FXS Module is independent and should be set accordingly.

LOOP START

Sets the port to use FXS loop start signaling on the T-span and loop start supervision on the analog 2-wire interface.

GROUND START

Sets the port to use FXS ground start signaling on the T-span and ground start supervision on the analog 2-wire interface.

PLAR

Sets the port to use Private Line, Automatic Ringdown signaling on the analog 2-wire interface. When one end of a PLAR circuit goes off-hook, the other end automatically rings. PLAR circuits are point to point between two interfaces.

TR08 SINGLE

Sets the port to use Single Party Channel Unit signaling on the T-span (as defined by TR-TSY-000008) and loop start supervision on the analog 2-wire interface.

TR08 UVG

Sets the port to use Universal Voice Grade signaling on the T-span (as defined by TR-TSY-000008) and either loop start or ground start supervision on the analog 2-wire interface.

DPO

Sets the port to use Dial Pulse signaling to originate dialed numbers.

TANDEM (E&M)

Sets the port to use E&M signaling on the T-span and either loop start or ground start supervision on the analog 2-wire interface. See the TANDEM submenus for more information.

64203376L1-1B

© 2004 ADTRAN, Inc.

103

Page 104

Section 4 User Interface Guide

Total Access 850 System Manual

INTERFACES (FXS) > CONFIG > TX (dB) Sets the TX direction level points. This signal will change the volume of the voice. TX (dB) is the signal that is transmitted out the T1, with 0 dB being the strongest. If the volume is too loud across the T1, this number should be increased. A higher number indicates more attenuation which equals lower volume. The value entered must be less than 10 dB. Default is 6.0 dB.

INTERFACES (FXS) > CONFIG > RX (dB) Sets the RX direction level points. This signal will change the volume of the voice. A higher number indicates more attenuation which equals lower volume. The value entered must be less than 10 dB. Default is 3.0 dB. The maximum signal is 0.0 dB.

INTERFACES (FXS) > CONFIG > SVC MODE Indicates whether the module is IN SERVICE or OUT OF SVC. This does not indicate whether the port has been mapped. For proper operation, the port must be mapped using the DS0 MAPS menu. Default is IN SERVICE.

INTERFACES (FXS) > CONFIG > LINE Z Sets the line impedance. Choices are 600 OHMS, 900 OHMS, 600 OHMS + 2.16µF, 900 OHMS + 2.16µF, and AUTO. The line impedance of each port is based on the size of the network. Default is 600 OHMS.

INTERFACES (FXS) > CONFIG > MSG IND This is better referred to as On-Hook Message Waiting. When this is set to ENABLE, talk path is always open, even in On-Hook conditions, in order for these FSK message tones to pass through. Default is DISABLE. Enabling on-hook message waiting will allow message lamp usage but will cause a lower on-hook voltage. Disabling this feature will allow higher on-hook voltage but will not allow on-hook messaging other than caller ID.

INTERFACES (FXS) > CONFIG > TANDEM Sets the port to use E&M signaling on the T-Span and either loop start or ground start supervision on the analog 2-wire interface. To access submenus for this item, use the arrow keys to scroll to the TANDEM column for the corresponding module, and then press <ENTER>.

INTERFACES (FXS) > CONFIG > TANDEM > CONVERSION MODE Sets the port to either LOOP START or GROUND START mode. Default is LOOP START.

INTERFACES (FXS) > CONFIG > TANDEM > SUPERVISION Sets the supervision method used to either IMMEDIATE or WINK. Default is IMMEDIATE.

INTERFACES (FXS) > CONFIG > TANDEM > DIAL TONE Used to enable or disable the on-board dial tone generation. Dial Tone is supplied for 5 sec; then it drops. It cannot be broken when dialing digits. Default is DISABLE.

INTERFACES (FXS) > CONFIG > TANDEM > RING BACK Used to enable or disable the option of generating ring back tone towards the T-span. Default is DISABLE. 104

© 2004 ADTRAN, Inc.

64203376L1-1B