Page 85
Total Access 850 System Manual
Section 4 User Interface Guide
SYSTEM CONFIG > SYSLOG > CMCP LEVEL Minimum required level for sending log messages about communication with the CopperMountain DSLAM. Messages are only generated for ATM products.
SYSTEM CONFIG > SYSLOG > SDSL LEVEL This parameter is for ADTRAN internal use only.
SYSTEM CONFIG > SYSLOG > L1 LEVEL Minimum required level for sending log messages about WAN physical or Layer 1 connection.
SYSTEM CONFIG > SYSLOG > ETH LEVEL Minimum required level for sending log messages about Ethernet physical connection.
SYSTEM CONFIG > SYSLOG > ICMP LEVEL Minimum required level for sending ICMP log messages.
SYSTEM CONFIG > SYSLOG > CONFIG LEVEL This parameter is for ADTRAN internal use only.
SYSTEM CONFIG > SYSLOG >DS0 LEVEL Minimum required level for sending log messages about DSO mapping.
SYSTEM CONFIG > SYSLOG > SELFTEST LEVEL Minimum required level for sending log messages about selftest.
SYSTEM CONFIG > SYSLOG > VOICE LEVEL Minimum required level for sending log messages about AAL2 voices services. Messages are only generated for ATM products.
SYSTEM CONFIG > SYSLOG > JETSTREAM LEVEL Minimum required level for sending log messages about communication with the JetStream Voice Gateway. Messages are only generated for ATM products.
SYSTEM CONFIG > SYSLOG > POTS LEVEL Minimum required level for sending log messages about POTS line cards and services.
SYSTEM CONFIG > SYSLOG > LESCAS LEVEL Minimum required level for sending messages about communication with LESCAS compatible Voice Gateways. Messages are only generated for ATM products.
64203376L1-1B
© 2004 ADTRAN, Inc.
85
Page 86
Section 4 User Interface Guide
Total Access 850 System Manual
SYSTEM CONFIG > SYSLOG > ATM LEVEL Minimum required level for sending ATM log messages. Messages are only generated for ATM products.
SYSTEM CONFIG > SYSLOG > COPPERCOM LEVEL Minimum required level for sending log messages about communication with the CopperCom Voice Gateway. Messages are only generated for ATM products.
SYSTEM CONFIG > SYSLOG > VOFR LEVEL Minimum required level for sending voice-over-frame-relay log messages about communication with the CopperMountain DSLAM. Messages are only generated for ATM products.
SYSTEM CONFIG > SYSLOG > XMODEM LEVEL Minimum required level for sending XMODEM log messages for firmware and configuration transfers.
SYSTEM CONFIG > SYSLOG > EMWEB LEVEL This parameter is for ADTRAN internal use only.
SYSTEM CONFIG > SYSLOG > FRELAY LEVEL Minimum required level for sending frame relay log messages.
SYSTEM CONFIG > SYSLOG > BRIDGE LEVEL Minimum required level for sending bridge mode log messages.
SYSTEM CONFIG > SYSLOG > MAINT LEVEL Minimum required level for sending CRAFT port log messages.
SYSTEM CONFIG > SYSLOG > HDLC LEVEL Minimum required level for sending low level HDLC log messages.
SYSTEM CONFIG > SYSLOG > VOATM LEVEL Minimum required level for sending Voice-over-ATM log messages.
SYSTEM CONFIG > SYSLOG > PPPOA LEVEL Minimum required level for sending PPP-over-ATM log messages.
SYSTEM CONFIG > SYSLOG > FDL LEVEL Minimum required level for sending FDL log messages.
86
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 87
Total Access 850 System Manual
Section 4 User Interface Guide
SYSTEM CONFIG > NETWORK TIME Activate the network time and configure the server type, time zone and various other network time parameters from this menu.
SYSTEM CONFIG > NETWORK TIME > SERVER TYPE The unit time can be entered manually from the SYSTEM INFO menu, or the unit can receive time from an NTP/SNTP server. The NETWORK TIME menu includes all parameters relating to how the unit communicates with the time server. The server type defines the port on which the unit will listen to receive timing information from the time server. The choices are NT TIME and SNTP. When set to NT TIME, the unit will receive time from an NT server running SNTP software on its TIME port. When set to SNTP, the unit will receive time directly from an SNTP server. The factory default is SNTP.
SYSTEM CONFIG > NETWORK TIME > ACTIVE This network timing feature can be turned on and off. It determines whether the unit will request and receive time from a time server. The factory default is NO.
SYSTEM CONFIG > NETWORK TIME > TIME ZONE All time zones are based off of Greenwich Mean Time (GMT). The choices are listed below. •GMT •GMT -5 (EASTERN) •GMT -6 (CENTRAL) •GMT -7 (MOUNTAIN) •GMT -8 (PACIFIC) •GMT -9 (ALASKA) •GMT -10 (HAWAII)
The factory default is GMT-6 (CENTRAL).
SYSTEM CONFIG > NETWORK TIME > ADJUST FOR DAYLIGHT SAVING Since some areas of the world use Daylight Savings Time, the unit is designed to adjust the time on the first Sunday in April and the last Sunday in October accordingly if this option is turned on. The factory default is YES.
SYSTEM CONFIG > NETWORK TIME > HOST ADDRESS This is the IP address of the time server that the unit will request and receive time from. The factory default is no entry in the host address field.
SYSTEM CONFIG > NETWORK TIME > REFRESH This is the interval of time between each request the unit sends out to the time server. A smaller refresh time guarantees that the unit receives the correct time from the server and corrects possible errors more quickly. This may be more taxing on the machine. A range of refresh times is available for the user to decide which is best for their unit. Choices include 5 MINS, 10 MINS, 15 MINS, 20 MINS, 25 MINS, 30 MINS, 35 MINS, 40 MINS, 45 MINS, 50 MINS, 55 MINS, and 60 MINS. The factory default is 60 MINS.
64203376L1-1B
© 2004 ADTRAN, Inc.
87
Page 88
Section 4 User Interface Guide
Total Access 850 System Manual
SYSTEM CONFIG > NETWORK TIME > STATUS This displays the current status of the time negotiation process. If an error is displayed, check all connections and configurations to try to resolve the problem.
SYSTEM UTILITY Use the SYSTEM UTILITY menu to view and set the system parameters shown in Figure 5.
Figure 5. System Utility Menu
SYSTEM UTILITY > UPGRADE FIRMWARE Select the firmware upgrade method and perform upgrade from this menu.
SYSTEM UTILITY > UPGRADE FIRMWARE > TRANSFER METHOD The customer can update firmware when unit enhancements are released. The two methods for upgrading are XMODEM and TFTP. (See the DLP section of this manual for more information.) TFTP requires a TFTP server running on the network. The unit starts a TFTP client function which gets the upgrade code from the TFTP server. Selecting XMODEM will load the upgrade code through the CRAFT port using any PC terminal emulator with XMODEM capability. The factory default is TFTP.
SYSTEM UTILITY > UPGRADE FIRMWARE > TFTP SERVER ADDRESS This is required when the transfer method is TFTP. It is the IP address or domain name (if DNS is configured) of the TFTP server. The factory default is no entry in the TFTP SERVER ADDRESS field.
SYSTEM UTILITY > UPGRADE FIRMWARE > TFTP SERVER FILENAME This is required when the transfer method is TFTP. It is the case-sensitive file name which contains the upgrade code. The factory default is no entry in the TFTP SERVER FILENAME field. 88
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 89
Total Access 850 System Manual
Section 4 User Interface Guide
SYSTEM UTILITY > UPGRADE FIRMWARE > TRANSFER STATUS This appears when TFTP is used. It displays the status of the transfer as it happens. Any error or success message will be displayed here.
SYSTEM UTILITY > UPGRADE FIRMWARE > START TRANSFER This activator is used when the configurable items in this menu are complete. This will initiate the transfer for either TFTP or XMODEM upgrades. Before using START TRANSFER, the unit should have a valid IP address, subnet mask, and default gateway (if required). See DLP-3, Setting IP Parameters for the Total Access 850, for more information.
SYSTEM UTILITY > UPGRADE FIRMWARE > ABORT TRANSFER Use this activator to cancel any TFTP transfer in progress.
SYSTEM UTILITY > CONFIG TRANSFER Select the config transfer method and perform the transfer from this menu.
SYSTEM UTILITY > CONFIG TRANSFER > TRANSFER METHOD Sends a file containing the unit configuration to a PC connected to the CRAFT port using XMODEM protocol or to a file on a TFTP server using the TFTP protocol. CONFIG TRANSFER also lets you save the unit configuration as a backup file, so you can use the same configuration with multiple units. In addition, CONFIG TRANSFER can retrieve a configuration file from a
TFTP server. To support these transfers, ADTRAN delivers a TFTP program with the unit called TFTP Server. You can configure any PC running Microsoft Windows with this software, and store a configuration file. Before using START TRANSFER, the unit should have a valid IP address, subnet mask, and default gateway (if required). See DLP-3, Setting IP Parameters for the Total Access 850, for more information. Only one configuration transfer session (upload or download) can be active at a time. XMODEM and TFTP are supported.
SYSTEM UTILITY > CONFIG TRANSFER > TFTP SERVER IP ADDRESS Specifies the IP address of the TFTP server. Get this number from your system administrator. If using the ADTRAN Utilities TFTP server, this number appears in the TFTP server status window. The factory default value is 0.0.0.0.
SYSTEM UTILITY > CONFIG TRANSFER > TFTP SERVER FILENAME Defines the name of the configuration file that you transfer to or retrieve from the TFTP server. The default name is ta_iad.cfg, but you can edit this name.
64203376L1-1B
© 2004 ADTRAN, Inc.
89
Page 90
Section 4 User Interface Guide
Total Access 850 System Manual
SYSTEM UTILITY > CONFIG TRANSFER > CURRENT TRANSFER STATUS Indicates the current status of the update.
SYSTEM UTILITY > CONFIG TRANSFER > PREVIOUS TRANSFER STATUS Indicates the status of the previous update.
SYSTEM UTILITY > CONFIG TRANSFER > LOAD AND USE CONFIG Retrieves the configuration file specified in the TFTP SERVER FILENAME field from the server. To start this command, enter Y to begin or enter N to cancel. If you execute this command, the unit retrieves the configuration file, reboots, then restarts using the new configuration.
SYSTEM UTILITY > CONFIG TRANSFER > SAVE CONFIG REMOTELY Saves the configuration file specified in TFTP SERVER FILENAME to the server identified in TFTP SERVER IP ADDRESS. To start this command, enter Y to begin or enter N to cancel. Before using this command, you must have identified a valid TFTP server in TFTP SERVER IP ADDRESS.
SYSTEM UTILITY > SYSTEM UTILIZATION View the CPU utilization stats from this menu.
SYSTEM UTILITY > SYSTEM UTILIZATION > PERFORMANCE Clear the system utilization stats and view the total and current CPU utilization stats from this menu.
SYSTEM UTILITY > SYSTEM UTILIZATION > PERFORMANCE > CPU UTILIZATION Provides maximum CPU utilization percentages for the following intervals: FROM POWER-UP
Max CPU utilization since the last Total Access 850 restart.
LAST SECOND
Max CPU utilization in the last second. This is the most current CPU utilization information.
FROM LAST CLEAR
Max CPU utilization since the last manual clear of the performance statistics using the CLEAR STATS command.
SYSTEM UTILITY > SYSTEM UTILIZATION > PERFORMANCE > CLEAR STATS This activator will clear all the system utilization performance stats.
90
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 91
Total Access 850 System Manual
Section 4 User Interface Guide
SYSTEM UTILITY > PING Activate the ping test and define the ping packet characteristics from this menu.
SYSTEM UTILITY > PING > START/STOP Activator to start and cancel a ping test.
Only one ping session can be active at a time.
Diagnostic features such as ping, extended ping, traceroute, extended traceroute, and Telnet client can also be performed via TERMINAL MODE (see page 92).
SYSTEM UTILITY > PING > HOST ADDRESS IP address or domain name (if DNS is configured) of device to receive the ping. The factory default is no entry in the host address field.
SYSTEM UTILITY > PING > SIZE (40-1500) Total size of the ping to send. Range is 40 to 1500 bytes. The default is 64.
SYSTEM UTILITY > PING > # OF PACKETS Total packets to send every 2 seconds. Setting this to 0 allows the client to ping continuously. The default is 5.
SYSTEM UTILITY > PING > # TRANSMITS Total packets sent (read only).
SYSTEM UTILITY > PING > # RECEIVES Total packets received (read only).
SYSTEM UTILITY > PING > % LOSS Percentage loss based on ping returned from host (read only).
SYSTEM UTILITY > TRACEROUTE Utility program used to trace a data path to a final destination.
SYSTEM UTILITY > TRACEROUTE > TRACE TARGET Specifies the IP address of the remote system to trace the routes to.
64203376L1-1B
© 2004 ADTRAN, Inc.
91
Page 92
Section 4 User Interface Guide
Total Access 850 System Manual
SYSTEM UTILITY > TRACEROUTE > MAXIMUM HOPS Specifies the maximum number of router exchanges allowed when traveling to the final destination (specified using the TRACE TARGET field) Range is 1 to 30. Default is 30.
SYSTEM UTILITY > TRACEROUTE > TIMEOUT (IN SECS) Specifies the maximum delay (in milliseconds) given to a host (along a path to the final destination) to respond to the probe datagram sent before considering the packet a failure.
SYSTEM UTILITY > TRACEROUTE > RETRIES Specifies the number of times the probe datagram is sent to each host (along the path to the final destination).
SYSTEM UTILITY > TRACEROUTE > BEGIN TRACEROUTE Activates the traceroute process by sending a probe datagram with a Time To Live (TTL) value of 1.
SYSTEM UTILITY > RESET UNIT Selecting this activator will power reset the unit.
SYSTEM UTILITY > TERMINAL MODE Selecting the terminal mode gives the user a command-line prompt to perform utilities such as pings, traceroutes, resets, firmware updates, configuration, and more. TERMINAL MODE can also be accessed by using the shortcut keys <CNTRL+T> from other menu screens. From this command-line prompt, you can: • • •
• • • • • •
Perform a reset with the command "reset" Perform a complete factory restore with the command "factory_reset" Configure the unit. The unit has the ability to download a text file which contains the configuration of the entire unit. This configuration may then be altered in a text editor, and then uploaded to a unit. (See DLP-13, Saving and Loading Text Configuration using Terminal Command Line, for further assistance.) Debug and troubleshoot. This function would be carried out with the assistance of ADTRAN Technical Support. Start and stop the fail-safe timer for the auto-config feature. Perform a firmware upgrade via TFTP. upgrade_firmware hostname filename Use the save command to write the entire configuration to flash. Display the unit’s MAC address with the command mac. Perform a ping or extended ping. Syntax is: ping hostname/address [repeat xx] [size xx] [timeout xx] [source xx] [noNat] Options:
92 repeat <repeat count>
Number of pings to send (default 5)
size (datagram size)
Range is 40-1500
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 93
Total Access 850 System Manual
Section 4 User Interface Guide timeout (seconds)
Timeout in seconds (range 1-10)
source (address or name)
Source address or interface name to use noNat
Do not NAT the ping packet
Options may be entered in any order and may be truncated. Valid interface names are eth0, fdl0, ppp0, fr0, fr1, etc. Example usage: ping 10.0.0.5 r si 1500 so eth0 n This will ping with a repeat count of 10. The datagram size is 1500 bytes, and the source address used in the ping packet will be the Ethernet IP address. The “noNat” option has been specified, so if NAT is enabled, this packet will NOT be translated. •
Perform a traceroute or extended traceroute. Syntax is: traceroute hostname/address [hops xx] [timeout xx] [retries xx] [source xx] [noNat] Options: hops <hops count>
Max number of hops (default 30)
timeout <seconds>
Timeout in seconds (default 3)
retries <seconds>
Number of retries per hop (default 3)
source <address or name>
Source address or interface name to use noNat
Do not NAT the trace packets
Options may be entered in any order and may be truncated. Valid interface names are eth0, fdl0, ppp0, fr0, fr1, etc. Example usage: trace 10.0.0.5 h 20 t 1 r 1 so eth0 This will perform a trace to 10.0.0.5 with a max hop count of 20. The timeout for each hop is 1 second, and the retry count per hop is 1. The Ethernet IP will be used as the source address, and the packet WILL go through NAT if NAT is enabled, meaning that the packet will be translated and the source address will be replaced by the NAPT address. •
Use the Telnet client feature to Telnet to a remote host. Syntax is: Telnet hostname/address [port xx] Default port is 23 (TELNET).
•
To exit terminal mode, type exit or !exit, exit - if any configuration have been made, you will be prompted whether or not to save these changes. If no changes were made, the terminal session will exit without the confirm message. !exit - exit without saving or applying any configuration changes. Extended ping, extended traceroute, and Telnet client are new features initially available in A.04.02. These functions may be performed simultaneously from multiple user sessions.
64203376L1-1B
© 2004 ADTRAN, Inc.
93
Page 94
Section 4 User Interface Guide
Total Access 850 System Manual
INTERFACES Use the INTERFACES menu to view and configure parameters for the T1, ETHERNET, V.35, FXS, FXO, DSX-1 MODULE, and UBR1TE interfaces as shown in Figure 6.
Figure 6. Interfaces Menus
INTERFACES (NETWORK T1) View the network T1 interface status and configure T1 parameters from this menu.
INTERFACES (T1) > CONFIG Configure the various T1 parameters and enable/disable loopbacks from this menu.
INTERFACES (T1) > CONFIG > TIMING MODE Choices are NETWORK and INTERNAL. Select NETWORK when the unit will receive timing from the network. Select INTERNAL when the unit will generate the timing. Default is NETWORK.
INTERFACES (T1) > CONFIG > FORMAT This sets the frame format for the T1 interface. The setting must match the frame format of the circuit to which the interface is connected. Choices are ESF or SF (D4). Extended Superframe (ESF) provides a non-disruptive means of full-time monitoring on the facility datalink (FDL). Default is ESF.
INTERFACES (T1) > CONFIG > LINE CODE This sets the line code for the T1 interface. The setting must match the line code of the circuit to which the interface is connected. Choices are B8ZS (bipolar with 8-zero substitution) and AMI (alternate mark inversion). Default is B8ZS. 94
© 2004 ADTRAN, Inc.
64203376L1-1B