Page 75
Total Access 850 System Manual
Section 4 User Interface Guide
SYSTEM CONFIG Set up the unit’s operational configuration from the SYSTEM CONFIG menu. Figure 4 shows the items included in this menu.
Figure 4. System Config Menu
SYSTEM CONFIG > MANAGEMENT Set up the CRAFT PORT, TELNET ACCESS, SNMP MANAGEMENT, and FDL MANAGEMENT from this menu.
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT Set up the CRAFT PORT parameters from this menu. The unit’s VT100 CRAFT port can be accessed via an RJ-48 connector located on the rear of the unit, or via the DB-9 connector on the front of the unit.
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > PASSWORD PROTECT When PASSWORD PROTECT is set to NO, the CRAFT port is not password protected. When set to YES (def), the unit will prompt for a password upon startup.
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > PASSWORD Enter the user-defined password (up to 30 alphanumeric characters including spaces and special characters) to protect the CRAFT port. By default, no password is entered. Table 2 on page 76 provides instructions for changing the password. Connecting directly to the CRAFT port provides full access to all menus. Enable the password on the CRAFT port to protect against unauthorized access.
64203376L1-1B
© 2004 ADTRAN, Inc.
75
Page 76
Section 4 User Interface Guide
Total Access 850 System Manual
Table 2. Instructions for Changing Passwords Step
Action
1
Select the PASSWORD field - a new PASSWORD field displays.
2
Type the new password in the ENTER field.
3
Type the new password again in the CONFIRM field.
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > IDLE TIME This option defines the amount of time in minutes user may stay connected without any activity on the CRAFT port before the user is automatically logged out of the system. A value of 0 disables this inactivity timer function enabling users to stay connected until manually logged out. The value range is 0 (def) to 255 (minutes).
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > BAUD RATE This is the asynchronous rate that the CRAFT port will run. The possible values are 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200. The default value is 9600.
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > DATA BITS This is the asynchronous bit rate that the CRAFT port will run. The possible values are 7 or 8 (def) bits.
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > PARITY This is the asynchronous parity that the CRAFT port will run. The possible values are NONE (def), ODD, or EVEN.
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > STOP BITS This is the number of stop bits used for the CRAFT port. The possible values are 1 (def), 1.5 or 2.
SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS Activate the Telnet access and set up the various Telnet parameters from this menu. The Total Access 850 supports up to five simultaneous Telnet sessions. The Total Access 850 ships with default Telnet Access parameters of: guest (user), password (password). Change this password during the initial configuration to protect your unit.
SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS > ACCESS Sets ACCESS to ON or OFF. The factory default value for this parameter is ON.
76
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 77
Total Access 850 System Manual
Section 4 User Interface Guide
SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS > AUTHEN METHOD Set up the Telnet authentication method from this menu. The choices are LOCAL PASSWORD, RADIUS, LOCAL/RADIUS, and RADIUS/LOCAL. LOCAL/RADIUS indicates that the unit will try Local Password Authentication first, and if that fails, it will try Radius Authentication. RADIUS/LOCAL indicates that the unit will try Radius authentication first, and if that fails, it will try Local Password authentication. The default is LOCAL PASSWORD.
SYSTEM CONFIG > MANAGEMENT > TELNET PORT Defines the TCP port number used when establishing a Telnet session. Normal Telnet port is 23. Enter a customized port number if desired.
SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS > USER LIST Add Telnet users and control the Telnet access conditions through this menu. #
Display the index number of the Telnet users. Up to four users can be configured for access to the unit. Each user can be assigned a security level and idle time. NAME
The name is a text string of the user name for this session. You can enter up to 15 characters in this field. The factory default is no entry in the NAME field. PASSWORD
When the authenticating method is password, or password radius, this text string is used for the password. You can enter up to 30 characters in this field. The factory default is no entry in this field. IDLE TIME (MINS)
This sets the amount of time in minutes you can be idle before you are automatically logged off. The factory default is 10 MINUTES. The range is 1 TO 255 MINUTES. LEVEL
This is the security level granted to the user. Table 3 on page 78 gives a brief description of each level. The factory default is FULL.
64203376L1-1B
© 2004 ADTRAN, Inc.
77
Page 78
Section 4 User Interface Guide
Total Access 850 System Manual
Table 3. Telnet Security Levels Security Level
Description
Full
The user has all access to view and configure all menus (same as logging in to the CRAFT port)
Support
The user has read only access to view the SYSTEM INFO menu. The user has privileges to view and change everything under the SYSTEM CONFIG menu except for the CRAFT port settings, Telnet access lists, and the SNMP management communities. The user has full access to the SYSTEM UTILITY menu, including the ability to upgrade firmware and reset the unit. The user has full access to the INTERFACES, L2 PROTOCOL, BRIDGE, ROUTER, and DS0 menus. The user does not have the ability to set RADIUS SERVER settings under the SECURITY menu.
Config
The same privileges as support, except that the user does not have privileges to download firmware or configuration from the SYSTEM UTILITY menu. The user additionally does not have the privilege to reset the unit remotely, or enter the terminal menu.
Router
The user has read only privileges for the SYSTEM INFO menu. There is no access to the SYSTEM CONFIG menu. The user has PING and TRACEROUTE access from the SYSTEM UTILITY menu. The user is limited to Ethernet configuration and status from the INTERFACES menu. The user has full access to the BRIDGE and ROUTER menus. Access is limited to filters only from the SECURITY menu.
Voice
The user has read only privileges for the SYSTEM INFO menu. The user has access to the PING and TRACEROUTE utilities from the SYSTEM UTILITIES menu. The user has full access to the FXS module from the INTERFACES menu.
Status
The user has read access of all menus except for the following: SYSTEM CONFIG/CRAFT PORT, SYSTEM CONFIG/TELNET ACCESS, SYSTEM CONFIG/SNMP MANAGEMENT, and SECURITY/ RADIUS SERVER. The user does not have access to UPGRADE FIRMWARE, UPGRADE CONFIG, PING, or TRACEROUTE menus. The user cannot reset the unit or enter terminal mode.
SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS > ACTIVE SESSIONS Provides a list of all Telnet sessions currently active on the Total Access 850 system. #
Displays the index number of the Telnet user. NAME
Displays the text string entered in the Telnet configuration for this user. PORT
Displays the TCP port used for this Telnet session. TIME TO LIVE
Displays the amount of time (in minutes) before this Telnet session is terminated by the Total Access 850.
78
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 79
Total Access 850 System Manual
Section 4 User Interface Guide
SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS > IP ACCESS LIST Set up the list of allowed Telnet managers. NETWORK ADDRESS
Enter network addresses from which Telnet access to the unit is allowed. When a remote unit requests Telnet access to the unit, if the access list is empty or the remote’s IP address matches a list entry, remote access is granted. A network address of 0.0.0.0 with corresponding netmask 255.255.255.255 blocks all host Telnet access. The factory default is 0.0.0.0. (with a 0.0.0.0 subnet mask), which allows all users Telnet IP access. MASK
Enter a subnet mask corresponding to the entered network address. When a remote unit requests Telnet access to the unit, if the access list is empty or the remote’s IP address matches a list entry, remote access is granted. A subnet mask of 0.0.0.0 will allow any host Telnet access, regardless of the network address. A network address of 0.0.0.0 with corresponding netmask 255.255.255.255 blocks all host Telnet access. The factory default is 0.0.0.0. for both parameters, which allows all users Telnet IP access.
SYSTEM CONFIG > MANAGEMENT > SNMP MANAGEMENT Active the SNMP management and configure the SNMP communities and traps from this menu.
SYSTEM CONFIG > MANAGEMENT > SNMP MANAGEMENT > ACCESS When set to OFF, SNMP access is denied. When set to ON, the unit will respond to SNMP managers based on the configuration. The factory default is ON.
SYSTEM CONFIG > MANAGEMENT > SNMP MANAGEMENT > TRAP DELAY When enabled, the Total Access 850 inserts a delay before transmitting a created trap for the SNMP session.
SYSTEM CONFIG > MANAGEMENT > SNMP MANAGEMENT > COMMUNITIES Set up the SNMP communities parameters from this menu. #
Displays the index number of the SNMP Communities. This list is used to set up to 8 SNMP communities that the unit will allow.
NAME
This is the text string used to identify the SNMP community. The factory default is no entry in the name parameter.
64203376L1-1B
© 2004 ADTRAN, Inc.
79
Page 80
Section 4 User Interface Guide
Total Access 850 System Manual
PRIVILEGE
The access for this manager can be assigned three levels. The factory default is NONE. NONE
No access is allowed for this community or manager.
GET
Manager can only read items.
GET/SET
Manager can read and set items.
MANAGER IP
This may be used in conjunction with the Netmask field to define a range of manager IPs. A netmask of 255.255.255.255 defines a single IP as the manager host IP. The default value is 0.0.0.0. NETMASK
The mask is used to determine which bits of the MANAGER IP are significant. A "0" bit means "don't care." A "1" bit means that the corresponding address bits in the incoming SNMP packet must match the address bit in the defined MANAGER IP. The netmask of 255.255.255.255 defines a single IP as the manager host IP. The default value is 0.0.0.0.
SYSTEM CONFIG > MANAGEMENT > SNMP MANAGEMENT > TRAPS Sets up the trap manager name and IP from this menu. #
Displays the index number in the SNMP traps table. This list allows up to 20 managers to be listed to receive traps. MANAGER NAME is the text string describing the name of the entry. It is intended for easy reference and has no bearing on the SNMP trap function. You can enter up to 31 characters in this field. The factory default is no entry in the manager name field. MANAGER IP
This is the IP address of the manager that is to receive the traps. The factory default is 0.0.0.0.
SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT Enables the FDL management and configures mode and IP addresses from this menu.
SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT > MODE This enables the FDL (only in ESF mode) to be used for management. Learning mode can also be enabled so the unit can "learn" its IP configuration to be used for its FDL management. Once it learns this information from, for example a Total Access 4303, the configuration items populate. The factory default is ON.
80
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 81
Total Access 850 System Manual
Section 4 User Interface Guide
SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT > LINK IP ADDRESS This is the local IP address used for FDL management. The FDL uses a separate IP network for communication, distinct from the customer data that is configured under the ROUTER menus. The factory default is 0.0.0.0.
SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT > IP NETMASK This is the subnet mask defining the IP network used for FDL management. The factory default is 0.0.0.0.
SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT > FAR-END IP ADDRESS This is the far-end IP address used for the FDL management. The FDL is a separate IP network from the customer data that is configured under the ROUTER menus. The factory default is 0.0.0.0.
SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT > LEARN ADDRESS When set to ON, the destination address on each received packet is assumed to be the FDL interface address. A 255.255.255.254 netmask is used, which determines the far-side address as well (since there can be only two addresses on a subnet with that netmask). When set to OFF, the user must input the IP address assigned to the FDL interface. Default is ON.
SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT > ACCEPT ALL SNMP When set to ON, SNMP gets/sets received over the FDL link are always accepted regardless of the community table. When set to OFF, the community table is searched for valid manager IP addresses and the SNMP traffic is rejected if a match is not found. Default is ON.
SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT > MTU (Maximum Transmit Unit) Defines the largest packet size sent over the FDL. All packets greater in size than the MTU are fragmented.
SYSTEM CONFIG > SYSLOG Configure the unit Syslog client for use with a Syslog server (supplied with ADTRAN Utilities or available on most Unix platforms) from this menu.
For additional information, reference RFC3164: The BSD Syslog Protocol.
SYSTEM CONFIG > SYSLOG > SYSLOG IP IP address of the syslog daemon to which log message should be sent. The values must be dotted decimal notation.
64203376L1-1B
© 2004 ADTRAN, Inc.
81
Page 82
Section 4 User Interface Guide
Total Access 850 System Manual
SYSTEM CONFIG > SYSLOG > SYSLOG FORMAT The SYSLOG FORMAT is the format of log messages. "ADTRAN" uses a format that is compatible with ADTRAN Utilities and forces the Syslog Facility to LOCAL0. UNIX uses the traditional Unix format and reports at the configured facility level.
ADTRAN Utilities may malfunction if messages are received in the Unix format.
SYSTEM CONFIG > SYSLOG > SYSLOG FACILITY The choices are: LOCAL0, LOCAL1, LOCAL2, LOCAL3, LOCAL4, LOCAL5, LOCAL6, LOCAL7. SYSLOG FACILITY is the facility level for all messages forwarded from the unit to the syslog server. This allows all messages received from the IAD to be filtered by facility level. See RFC3164: The BSD Syslog Protocol. This does not have to correspond to the facility level shown in the terminal mode option. See SYSLOG using Terminal Mode on page 83. The remaining Syslog parameters have the following level choices: FATAL (Highest priority) ALERT CRITICAL ERROR WARNING NOTICE INFO DEBUG (Lowest priority) Every log message generated by the IAD has a reporting level priority. If the message priority is lower than the configured priority for the destination log, the message is not forwarded to the syslog daemon. See RFC3164: The BSD Syslog Protocol. The lower the log level, the more messages that will be generated. Setting reporting levels to DEBUG may negatively affect the performance of the IAD, including causing the IAD to reset. ADTRAN recommends using DEBUG for only short periods of time, and for debug purposes only.
82
© 2004 ADTRAN, Inc.
64203376L1-1B
Page 83
Total Access 850 System Manual
Section 4 User Interface Guide
SYSLOG using Terminal Mode Another option for configuring syslog is using the terminal mode command log dump <logname>. The logname must be all CAPS and be one of the following names: FATAL ALERT CRITICAL ERROR WARNING NOTICE INFO FILTER DEBUG The command will dump all messages for the indicated log (ALL LEVEL shows all log messages) stored in the internal log buffer to the command line display.
SYSTEM CONFIG > SYSLOG > ALL LEVEL This entry allows setting the default reporting level for all log entries. If ALL LEVEL is a lower priority than the individual log entry level, ALL LEVEL overrides the individual log reporting level.
SYSTEM CONFIG > SYSLOG > KERNEL LEVEL Minimum required level for sending KERNEL log messages.
SYSTEM CONFIG > SYSLOG > DHCP LEVEL Minimum required level for sending DHCP log messages.
SYSTEM CONFIG > SYSLOG > NTP LEVEL Minimum required level for sending NTP log messages.
SYSTEM CONFIG > SYSLOG > TFTP LEVEL Minimum required level for sending TFTP log messages.
SYSTEM CONFIG > SYSLOG > TELNET LEVEL Minimum required level for sending TELNET log messages.
SYSTEM CONFIG > SYSLOG > IP LEVEL Minimum required level for sending IP log messages.
SYSTEM CONFIG > SYSLOG > PPP LEVEL Minimum required level for sending PPP log messages.
SYSTEM CONFIG > SYSLOG > NAT LEVEL Minimum required level for sending NAT log messages.
64203376L1-1B
© 2004 ADTRAN, Inc.
83
Page 84
Section 4 User Interface Guide
Total Access 850 System Manual
SYSTEM CONFIG > SYSLOG > ARP LEVEL Minimum required level for sending ARP log messages.
SYSTEM CONFIG > SYSLOG > UDP LEVEL Minimum required level for sending UDP log messages.
SYSTEM CONFIG > SYSLOG > NETWRITE LEVEL This parameter is for ADTRAN internal use only.
SYSTEM CONFIG > SYSLOG > TCP LEVEL Minimum required level for sending TCP log messages.
SYSTEM CONFIG > SYSLOG > COMPSYS LEVEL This parameter is for ADTRAN internal use only.
SYSTEM CONFIG > SYSLOG > CONSOLE LEVEL This parameter is for ADTRAN internal use only.
SYSTEM CONFIG > SYSLOG > CFGXFER LEVEL Minimum required level for sending configuration transfer log messages.
SYSTEM CONFIG > SYSLOG > ROUTER LEVEL Minimum required level for sending router log messages.
SYSTEM CONFIG > SYSLOG > NONVOL LEVEL Minimum required level for sending nonvolatile memory log messages.
SYSTEM CONFIG > SYSLOG > NOKIA LEVEL Minimum required level for sending log messages about communication with the Nokia DSLAM. Messages are only generated for products with an SDSL WAN interface.
SYSTEM CONFIG > SYSLOG > AUTOBAUD LEVEL Minimum required level for sending log messages about communication with the Lucent Stinger DSLAM. Messages are only generated for products with an SDSL WAN interface.
SYSTEM CONFIG > SYSLOG > TOLLBRG LEVEL Minimum required level for sending log messages about communication with the Tollbridge Voice Gateway. Messages are only generated for ATM products.
84
© 2004 ADTRAN, Inc.
64203376L1-1B