Page 9

Information and Precautions CHAPTER OBJECTIVES Chapter 1 provides information on the general intent of this manual, gives an overall description of the Bulletin 1305 Adjustable Frequency AC Drive (herein called “the drive”) and provides a listing of key drive options. Additionally, this chapter provides information on receiving and handling the drive.

MANUAL OBJECTIVES The purpose of this manual is to provide the user with the necessary information to install, program, start up and maintain the Bulletin 1305 drive. To assure successful installation and operation, the material presented must be thoroughly read and understood before proceeding. Particular attention must be directed to the ATTENTION and Important statements contained within. Chapter 2 provides instructions on how to mount and wire the drive. It also describes how to operate the drive without a Human Interface Module. Read the Motor Cable Length section on pages 2-13 – 2-16, and the contact closure inputs information in the Control Terminal Block descriptions on pages 2-19 – 2-21. Chapter 3 defines the display and control panel keys on the optional Human Interface Module. A flowchart is provided to guide the user through the key strokes of the various menu levels.

Chapter 1 Chapter 4 describes the steps to start up the drive. It includes a typical start up routine defining the adjustments and checks to assure proper operation. Chapter 5 outlines the parameter information of the drive such as description, number, type, units, factory default, minimum and maximum settings. Chapter 6 defines the various drive faults and the appropriate action to take as well as general troubleshooting information. Appendix A contains a block diagram and general specifications of the drive. Appendix B provides the necessary information for drive set up using a PLCR, SLC or other logic controller. A table is provided that lists each parameter by parameter group with space for the user to record any custom parameter settings. Appendix C lists the accessories and their catalog number. Appendix D lists requirements for CE conformity. Index – A comprehensive index is provided to assist the user in locating specific information. All parameters and fault information are listed alphabetically under parameters and faults respectively. PLC is a registered trademark of Allen-Bradley Company. SLC is a trademark of Allen-Bradley Company.

Page 10

1-2

Information and Precautions

Receiving – It is the responsibility of the user to thoroughly inspect the equipment before accepting the shipment from the freight company. Check the item(s) received against the purchase order. If any items are obviously damaged, it is the responsibility of the user not to accept delivery until the freight agent has noted the damage on the freight bill. Should any concealed damage be found during unpacking, it is again the responsibility of the user to notify the freight agent. The shipping container must be left intact and the freight agent should be requested to make a visual inspection of the equipment. Unpacking – Remove all packing material from within and around the drive. Important: Before the installation and start-up of the drive, a general inspection of the mechanical integrity (i.e. loose parts, wires, connections, etc.) should be made. Inspection – After unpacking, check the item(s) nameplate catalog number against the purchase order. An explanation of the catalog numbering system for the Bulletin 1305 drive is included as an aid for nameplate interpretation. Refer to the following pages for complete nomenclature.

Storing – The drive should remain in its shipping container prior to installation. If the equipment is not to be used for a period of time, it must be stored according to the following instructions in order to maintain warrranty coverage: D Store in a clean, dry location. D Store within an ambient temperature range of –40_ to +70_C. D Store within a relative humidity range of 0% to 95%, noncondensing. D Do not store equipment where it could be exposed to a corrosive atmosphere. D Do not store equipment in a construction area.

GENERAL PRECAUTIONS In addition to the precautions listed throughout this manual, the following statements which are general to the system must be read and understood. The DC Bus Charge Indicator is a neon bulb that will be illuminated when power is applied to the drive.

Page 11

Information and Precautions

!

!

ATTENTION: This drive contains ESD (Electrostatic Discharge) sensitive parts and assemblies. Static control precautions are required when installing, testing, or servicing this assembly. Component damage may result if ESD control procedures are not followed. If you are not familiar with static control procedures, reference A-B publication 8000-4.5.2, ‘‘Guarding Against Electrostatic Damage ” or any other applicable ESD protection handbook. ATTENTION: An incorrectly applied or installed drive can result in component damage or a reduction in product life. Wiring or application errors, such as, undersizing the motor, incorrect or inadequate AC supply, or excessive ambient temperatures may result in malfunction of the system.

!

1-3

ATTENTION: Only personnel familiar with the the drive and associated machinery should plan or implement the installation, start-up and subsequent maintenance of the system. Failure to comply may result in personal injury and/or equipment damage.

CONVENTIONS USED IN THIS MANUAL Programmer Terminal will appear as Human Interface Module or HIM.

To help differentiate parameter names, display text, and control keys from other text in this manual, the following conventions will be used: Parameter Names will appear in [brackets]

Display Text will appear in ‘‘quotes”.

Control Key Names will appear as depicted on the control key, if the key is labeled with letters or numbers (i.e., JOG, SEL) or if the key depicts an icon, its operative term appear with initial capitalization (i.e., Stop, Increment, Enter).

Page 12

Information and Precautions

1-4

Figure 1.2 Nameplate Information

NAMEPLATE LOCATION Figure 1.1 Bulletin 1305 Nameplate Location

CAT 1305-BA03A-HAP I N P U T

V: 380-460 A: 2.2 Hz: 50/60 VA: 1800

SER C

O U V: 380-460 3Φ T A: 2.3 P Hz: 0-400 U Motor T Rating: 0.75KW / 1 HP MADE IN U.S.A.

Nameplate Located on Exterior of Enclosure

ES C SE L

JO

G

AB0516C

FIRMWARE COMPATIBILITY ➀ Drive:

Series C, FRN 6.01 and up

HIM:

Series A, FRN 1.0 through 3.0 Series B, FRN 1.0

➀ Specific Firmware versions are identified by digits to the right/left of decimal. Example 1.01, 2.01.

Firmware version can be found on the drive carton label, on integrated circuits found on the Control Board (see Figure 2.3), or can be viewed in Drive Diagnostics (see Chapter 5).

Page 13

Information and Precautions

CATALOG NUMBER CODE EXPLANATION

1305

–

A

A02

A

First Position

Second Position

Third Position

Fourth Position

BulletinNumber

Rating

Nominal Current Rating

Code Description A 200-240V , Single-Phase 200-230V, Three-Phase B 380-460V, Three-Phase

A01 A02 A03 A04 A06 A08 A09 A12

–

Enclosure Type

DE

–

HA1

Fifth Position

Sixth Position

Options

Code Enclosure Type A IP 30 (NEMA Type 1)

Language Code (English language is included in base catalog number. To order a second language, add the appropriate suffix to the drive catalog number.) DE German ES Spanish IT Italian FR French Human Interface Modules, NEMA Type 1 (IP 30) To order installed in the drive, add the appropriate suffix to the drive catalog number. HAP Programmer Only HA1 HIM with Analog Speed Pot HA2 HIM with Digital Up-Down Keys

1-5

Page 14

1-6

Information and Precautions

Table 1.A Drive Rating and Derating Guidelines

In general:

Motor Rating Voltage Rating 200-230V 50/60 Hz

380-460V 50/60 Hz

Catalog Number IP30 (NEMA Type 1) 1305-AA02A

Three-Phase Input

Single-Phase Input

HP kW

Output ➀➁ Current (A) HP kW

Output ➀➁ Current (A)

0.5

0.37

2.3

0.25

0.19

1.2

1305-AA03A

0.75

0.55

3

0.5

0.37

2.3

1305-AA04A

1

0.75

4.5

0.75

0.55

3

1305-AA08A

2

1.5

8

1

0.75

4.5

1305-AA12A

3

2.2

12 ➂

2

1.5

8 ➂

1305-BA01A

0.5

0.37

1.3

1305-BA02A

0.75

0.55

1.6

1305-BA03A

1

0.75

2.3

1305-BA04A

2

1.5

4

1305-BA06A

3

2.2

6 ➃

1305-BA09A

5

4.0

9 ➄

Not Available

➀ Motor Full Load Amps (FLA) should not exceed the drive output current rating. ➁ If the [PWM Frequency] is set above 4kHz, the output current must be derated per the chart on page 5-20.

When operating the drive in an ambient temperature at or near the maximum operating temperature (50°C), the following derating guidelines are recommended to guard against overheating depending on application and operating conditions. ➂ Output current value listed for 200V input voltage. At 230V input voltage, output current is 9.6A for 3 phase and 6.8A for single phase. ➃ Output current value listed for 380V input voltage. At 415V input voltage, output current is 5.3A. At 460V input voltage, output current is 4.8A. ➄ Output current value listed for 380V input voltage. At 415V input voltage, output current is 8.4A. At 460V input voltage, output current is 7.6A.

For derating guidelines at ambient temperatures between 40°C and 50°C, consult Allen-Bradley.