The text of a manual · part 7 of 21
User Manual: 1305 Adjustable Frequency AC Drive (Series C): 3 - HIM, pages 39 to 48
Pages 39 to 48 of 170, from User Manual: 1305 Adjustable Frequency AC Drive (Series C)
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 1305-BA03A
Page 39
Human Interface Module CHAPTER OBJECTIVES Chapter 3 describes the various controls and indicators found on the optional Human Interface Module (HIM) of the Bulletin 1305 AC Drive. The material presented in this chapter must be understood to perform the start-up procedure in Chapter 4.
Chapter 3 above or Series B version 1.01 and above (see back of HIM), the Status Display, Process Display or Password Login menu can be selected as the power-up display or menu. See appropriate sections on the following pages for more information. Figure 3.1 Human Interface Module
HIM DESCRIPTION When the drive mounted HIM is supplied, it will be connected as Adapter 1 (see Adapter in Chapter 2) and visible from the front of the drive. The HIM can be divided into two sections; Display Panel and Control Panel. The Display Panel provides a means of programming the drive and viewing the various operating parameters. The Control Panel allows different drive functions to be controlled. Refer to Figure 3.1 and the sections that follow for a description of the panels. Important: The operation of some HIM functions will depend upon drive parameter settings. The default parameter values allow full HIM functionality.
LCD Display Display Panel Digital Speed Control and Indicator (also available with Analog Speed Pot.) Control Panel
HIM OPERATION When power is first applied to the drive, the HIM will cycle through a series of displays. These displays will show drive name, HIM ID number and communication status. Upon completion, the Status Display will be shown. This display shows the current status of the drive (i.e. “Stopped,” “Running,” etc.) or any faults that may be present (“Serial Fault,” etc.). If the HIM software is Series A version 3.00 and
From this display, pressing any one of the five Display Panel keys will cause “Choose Mode” to be displayed. Pressing the Increment or Decrement keys will allow different modes shown in Figure 3.3.
Page 40
3-2
Human Interface Module
Display Panel Descriptions Escape When pressed, the ESC key will cause the programming system to go back one level in the menu structure. Select Pressing the SEL key alternately moves the cursor to the next active area. A flashing first character indicates which line is active. Increment/Decrement These keys are used to increment and decrement a value or scroll through different groups or parameters. Enter When pressed, a group or parameter will be selected or a parameter value will be entered into memory. After a parameter has been entered into memory, the top line of the display will automatically become active, allowing another parameter (or group) to be chosen. Control Panel Descriptions Important: The following information is correct as shipped from the factory. Reprogramming of mask parameters can mask out control of some of these functions.
Start The Start key will initiate drive operation if no other control devices are sending a Stop command. This key can be disabled by the [Logic Mask] or [Start Mask]. Stop If the drive is running, pressing the Stop key will cause the drive to stop, using the selected stop mode. Refer to the [Stop Select] in Chapter 5. If the drive has stopped due to a fault, pressing this key will clear the fault and reset the drive. Refer to the [Flt Clear Mode], [Logic Mask] and [Fault Mask] parameters. Jog When pressed, jog will be initiated at the frequency set by the [Jog Frequency] parameter, if no other control devices are sending a Stop command. Releasing the key will cause the drive to stop, using the selected stop mode. Refer to [Stop Select], [Logic Mask] and [Jog Mask]. Important: If the drive is running prior to issuing a jog command, the jog command will be ignored. Important: A start command from another source will override the jog command.
Page 41
Human Interface Module
Control Panel Descriptions (continued)
3-3
Increment/Decrement Arrows (only available with digital speed control)
Change Direction Pressing this key will cause the drive to ramp down to 0 Hz and then ramp up to set speed in the opposite direction. The appropriate Direction Indicator will illuminate to indicate the direction of motor rotation. Refer to [Logic Mask] and [Direction Mask]. Note that the factory default for control of the reverse function is the reverse input at the TB2 control terminal block. To enable the HIM control of the reverse function, change Bit 0 of the [Direction Mask] parameter to “0” to disable the reverse function at TB2. Direction LEDs (Indicators) These LEDs illuminate to indicate the direction of motor rotation.
Pressing these keys will increase or decrease the HIM frequency command. An indication of this command will be shown on the visual Speed Indicator LEDs. The drive will run at this command if the HIM is the selected frequency reference. See [Freq Select 1/2]. Pressing both keys simultaneously stores the current HIM frequency command in HIM memory. The Speed Indicator LEDs will flash momentarily to indicate a successful save (if speed is above 20 percent). Cycling power or connecting the HIM to the drive will set the frequency command to the value stored in HIM memory. If the Analog Speed Potentiometer option has been ordered, the Increment/Decrement keys and Speed Indicator will be replaced by the pot.
Rotating "Forward" OFF
Steady ON
Speed Indicator LEDs Rotating "Reverse" Steady ON
OFF
Flashing Steady ON
Changing Direction, Decelerating "Reverse," will begin to Accelerate "Forward."
Steady ON Flashing
Changing Direction, Decelerating "Forward," will begin to Accelerate "Reverse."
(only available with digital speed control)
Illuminates in steps to give an approximate visual indication of the commanded speed. If the Analog Speed Potentiometer option has been ordered, the Increment/Decrement keys and Speed Indicator LEDs will be replaced by the pot.
Page 42
3-4
Human Interface Module
HIM REMOVAL AND INSTALLATION In addition to mounting directly on the drive, the HIM can be used as a hand held programmer or it can be mounted on the front of an enclosure. The HIM can be removed from the drive in one of two methods:
Important: When the [Logic Mask] bit for an adapter is changed from ‘‘1” to ‘‘0” it disables all command functions for that adapter with the exception of the Stop command and frequency reference. 1. Lower the hinged panel located below the HIM.
A. Disconnect power from the drive and remove the HIM as outlined in steps 1 and 2, or
2. Press the retaining lever located directly beneath the HIM, slide the HIM downward and remove it from the drive.
B. Remove the HIM from the drive with the drive running, by masking out the [Logic Mask] bit that identifies the adapter address of the HIM. Refer to Figure 2.11 to identify the adapter address for the HIM or view the HIM ID# on the display as the unit is powered up. The ID # corresponds to the adapter address. Refer to page 5-47 for programming instructions on the [Logic Mask] parameter. For HIM software, Series A version 3.00 and above or Series B version 1.01 and above, you can enter the Control Status menu and Enable/Disable the Control Logic bit.
3. To reinsert the HIM, place the top edge of the HIM about 15 mm (1/2 in.) from the top edge of the cover. Push inward on the bottom of the HIM and slide the HIM up into position.
Important: If the [Logic Mask] bit of the adapter is not masked out (set to “0”), and the HIM is removed, a communication fault will occur and the drive will be disabled. However, if the HIM removed is the active frequency source, the drive will issue a “Hz Error” fault (F29).
Figure 3.2 HIM Removal
ES C SE L
JO
G
ES C SE L
JO
G
Hinged Cover
Retaining Lever
Page 43
Human Interface Module
HIM MODES The HIM has up to seven different modes. Refer to Figure 3.3. Display When selected, the Display mode allows any of the parameters to be viewed. However, parameter modifications are not allowed. Process The Process mode allows a “configurable” display to be programmed. One user selected parameter can be displayed with programmed text and scaling. Refer to Chapter 5 for further information. Program Program mode provides access to the complete listing of parameters available for programming. Refer to Chapter 5 for further parameter programming information. EEPROM This mode allows all parameters to be reset to the factory default settings. For Series B HIM Software Version 1.01 and Above, uploading and downloading of drive parameters may be performed.
3-5
Search (Series A HIM, software V3.00 & up or Series B HIM, V1.01 & up Only)
This mode will search for parameters that are not at their default values. Control Status (Series A HIM, software V3.00 & up or Series B HIM, V1.01 & up Only)
Permits the [Logic Mask] parameter to be disabled/enabled allowing HIM removal while drive power is applied. This menu also provides access to a fault queue which will list the last four faults that have occurred. “Trip” displayed with a fault indicates the actual fault that tripped the drive. A clear function clears the queue. Important: Clearing the Fault Queue will not clear an active fault. Password The Password mode protects the drive parameters against programming changes by unauthorized personnel. When a password has been assigned, access to the Program and EEPROM modes can only be gained when the correct password has been entered. The password can be any five digit number between 00000 and 65535. Refer to the example on page 3-17.
Page 44
3-6
Human Interface Module Power-Up & Status Display
Figure 3.3 HIM Programming Steps
This flow chart serves as a guide to the key strokes required for movement throughout the menu levels.
ESC or
SEL or or
OPERATOR LEVEL or
"Choose Mode"
Display
Process
(Read Only)
Program ➀
EEPROM ➀
(Read/Write)
Process Display
Parameter Groups (See Chapter 5)
Parameters (See Chapter 5)
Search ➁ (Read Only)
Reset Defaults Upload Parameters ➂ Download Parameters ➂ Recall Values Save Values
Control Status ➁
Password
Control Logic ➀, Fault Queue
Login, Logout Modify
MODE LEVEL GROUP LEVEL
➀ Access to the Program and EEPROM modes, and the Control Logic and Clear Fault Queue, will be disabled if the password is Logged out. ➁ Series A HIM Software Version 3.00 and Above or Series B HIM Software Version 1.01 and Above only. ➂ Series B HIM Software Version 1.01 and Above only.
PARAMETER LEVEL
Page 45
Human Interface Module
PROGRAM AND DISPLAY MODES DESCRIPTION
ACTION
HIM DISPLAY
❏ 1. The Display and Program modes allow access to the parameters for viewing or programming.
or a. From the Status Display, press Enter (or any key). “Choose Mode” will be shown.
Choose Mode Display b. Press the Increment (or Decrement) key to show “Program” (or “Display”).
Choose Mode Program c. Press Enter. or d. Press the Increment (or Decrement) key until the desired group is displayed.
Choose Group Metering e. Press Enter. or f. Press the Increment (or Decrement) key to scroll to the desired parameter.
Output Current 0.00 Amps
3-7
Page 46
Human Interface Module
3-8
PROGRAM AND DISPLAY MODES (continued) ACTION
Changing Digits or SEL
DESCRIPTION
HIM DISPLAY
❏ 2. With Series A HIM software versions 3.00 and above, or Series B HIM software version 1.01 and above, you have the ability to access and modify each individual bit or digit. Important: This procedure assumes the Password is not set, you have already logged in, or the device has been set to Defaults. a. Select a parameter with Increment (or Decrement) keys.
Choose Group Setup b. Press the SEL key to view the first bit. Pressing this key again will move the cursor to the left one bit or digit.
Accel Time 99.9 Secs
Individual bits of a Read/Write parameter can be changed. Pressing the SEL key will move the cursor (flashing character) one bit to the left. That bit can then be changed by pressing the Increment/Decrement keys. When the cursor is in the far right position, pressing the Increment/Decrement keys will increment or decrement the entire value.
Flashing = Modify
Page 47
Human Interface Module
PROGRAM AND DISPLAY MODES (continued) ACTION
Bit ENUMs or
SEL
DESCRIPTION
HIM DISPLAY
❏ 3. With Series A HIM software versions 3.00 and above, or Series B HIM software version 1.01 and above, bit ENUMs (16 character text strings) will be displayed to aid interpretation of bit parameters. a. From the Choose Group menu, use the Increment/Decrement key to select the Masks group. Press Enter. b. Press the SEL key to view the ENUM of the first bit. Pressing this key again will move the cursor to the left one bit or digit and view the next bit’s ENUM.
Choose Group Mask Adapter 4 X1111111
Flashing
3-9
Page 48
Human Interface Module
3-10
PROCESS MODE ACTION
DESCRIPTION
HIM DISPLAY
❏ 1. When selected, the Process mode will show a custom display consisting of information programmed with the Process Display group of parameters. a. Complete steps a – c on page 3-7 to access the Program mode.
Choose Mode Program or b. Press the Increment/Decrement key until “Process Display” is shown. Press Enter.
Choose Group Process Display or c. Using the Increment/Decrement keys, select [Process Par] and enter the number of the parameter you wish to monitor. Press Enter.
Process Par 1 or d. Select [Process Scale] using the Increment/Decrement keys. Enter the desired scaling factor. Press Enter.
Process Scale +1.00 or e. Select [Process Text 1] using the Increment/Decrement keys. Enter the desired text character. Press Enter & repeat for the remaining characters.
Process Text 1 V
ESC or f. When process programming is complete, press ESC until “Choose Mode” is displayed. Press Increment/Decrement until “Process” is displayed. Press Enter to get process value.
Choose Mode Process press ESC
SEL g. With Series A HIM Software Versions 3.00 and above or Series B HIM Software Versions 1.01 and above. the user has the ability to save the Process Display for power up. To do this, simultaneously press Increment and Decrement keys on programming panel.
+0.00 V