The text of a manual · part 1 of 3
Bulletin 160 "Series C" Smart Speed Controllers Technical Data, pages 1 to 10
Pages 1 to 10 of 28
The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 160-AA08NSF1, Allen-Bradley 160-BA01NPS1, Allen-Bradley 160-BA01NSF1 and Allen-Bradley 160-BA03NPS1
Page 1
Allen-Bradley
Technical Data
Bulletin 160 “Series C” Smart Speed Controllers
Rockwell Automation
Page 2
A Step Above the Rest… Bulletin 160 Smart Speed Controller (SSC™) with Sensorless Vector Performance The Bulletin 160 Smart Speed Controller is available in models rated between 0.37 to 4 kW (0.5 to 5 horsepower) with voltage ratings 200-240V and 380-460V three-phase input and 0.37 to 1.5 kW (0.5 to 2 horsepower) 200-240V single phase input. When the Bulletin 160 SSC was first introduced in the market, its innovative design helped set the standard for future microdrives. With the Series C design, expanded power ratings (through 5 HP, 4 kW), increased functionality and an enhanced hardware design place the Bulletin 160 SSC a “Step Above the Rest” for small drive applications!
2
Page 3
Bulletin 160 “Series C” Smart Speed Controller with Sensorless Vector Performance Technical Data TABLE OF CONTENTS Standard Drives Program Description Page Catalog Number Description . . . . . . . . . . . . . . . . . . . . . 5 Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Operator Interface & Communication Devices . . . . . . . 6 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Accessories and Repair Parts – Field Installed . . . . . . 8 Bulletin 160 Block Diagram . . . . . . . . . . . . . . . . . . . . . 10 Branch Circuit Block Diagram . . . . . . . . . . . . . . . . . . . 10 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . 13 Communication Module Specifications . . . . . . . . . . . . 17 Display Parameter Descriptions . . . . . . . . . . . . . . . . . 17 Program Parameter Descriptions . . . . . . . . . . . . . . . . 18 Standard Drives Program – 160Z Catalog Number Description . . . . . . . . . . . . . . . . . . . . 19 Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Operator Interface➀ & Communication Devices . . . . 20 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . 23 Standard Packaged Drive Program Ordering Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Custom Configured Drives Program . . . . . . . . . . . . . . 24 Catalog Number Description . . . . . . . . . . . . . . . . . . . . 24 Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Factory Installed Enclosure Options . . . . . . . . . . . . . . 25 Option Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Approximate Dimensions for 160 NEMA Type 4/12 & 4X Stainless Steel Enclosures . . . . . . . . . . . . . . . . . . . . . 26
3
Page 4
Standard Drives Program
The 160 SSC (Smart Speed Controller) is a compact variable speed drive for use on three-phase induction AC motors. It is microprocessor controlled and fully programmable for a variety of applications. Standard Features Include: • Ratings of 0.37-4.0 kW (0.5-5 HP) • Very Compact Design • Feed Through Wiring • IGBT Technology • PWM Control • Quiet Operation • Programmable Standard Drive Configurations: • IP20 (Open Style) • Chassis Mount • 160Z (IP 65/NEMA 4X) Standard Packaged Drives Available: • IP66 (NEMA 4/12) • IP66 (NEMA 4X) Approvals: • UL (UL 508C) • C/UL (CSA 22.2) • CE➀ EMC Directive (EMC: EN61800-3, EN50081-1, EN50082-2) Low Voltage Directive (LVD: EN50178, EN6024-1) • C-Tick AS/NZS2064 ➀ External components and proper guidelines must be followed. Refer to the 160 User Manual for details.
Your order must include • Catalog number of the drive • If required, catalog number of any accessories and/or factory installed options.
4
Page 5
Standard Drives Program Catalog Number Description
160
– AA02
Bulletin Number
Drive Rating (must be specified)
N
SF1
P1
Enclosure Rating (must be specified)
Control Model (must be specified)
Programmer (optional)
Product Selection Drive Ratings Input Voltage Rating 200-240V 50/60 Hz Single-Phase
200-240V 50/60 Hz Three-Phase
380-460V 50/60 Hz Three-Phase kW 0.37 0.55 0.75 1.5 0.37 0.55 0.75 1.5 2.2 4.0 0.37 0.55 0.75 1.5 2.2 4.0
HP 0.5 0.75 1 2 0.5 0.75 1 2 3 5 0.5 0.75 1 2 3 5
Output Current Rating 2.3A 3.0A 4.5A 8.0A 2.3A 3.0A 4.5A 8.0A 12.0A 18.0A 1.2A 1.7A 2.3A 4.0A 6.0A 10.5A
IP 20 (Open Style) Analog Signal Follower Model Catalog Number ➀➂ 160S - AA02NSF1 160S - AA03NSF1 160S - AA04NSF1 160S - AA08NSF1 160 - AA02NSF1 160 - AA03NSF1 160 - AA04NSF1 160 - AA08NSF1 160 - AA12NSF1 160 - AA18NSF1 160 - BA01NSF1 160 - BA02NSF1 160 - BA03NSF1 160 - BA04NSF1 160 - BA06NSF1 160 - BA10NSF1
Preset Speed Model Catalog Number ➀➂ 160S - AA02NPS1 160S - AA03NPS1 160S - AA04NPS1 160S - AA08NPS1 160 - AA02NPS1 160 - AA03NPS1 160 - AA04NPS1 160 - AA08NPS1 160 - AA12NPS1 160 - AA18NPS1 160 - BA01NPS1 160 - BA02NPS1 160 - BA03NPS1 160 - BA04NPS1 160 - BA06NPS1 160 - BA10NPS1
Output Current Rating 2.3A 3.0A 4.5A 8.0A 2.3A 3.0A 4.5A 8.0A 12.0A 18.0A 1.2A 1.7A 2.3A 4.0A 6.0A 10.5A
IP 20 (Chassis Mount) ➁ Analog Signal Follower Model Catalog Number ➀➂ 160S - AA02PSF1 160S - AA03PSF1 160S - AA04PSF1 160S - AA08PSF1 160 - AA02PSF1 160 - AA03PSF1 160 - AA04PSF1 160 - AA08PSF1 160 - AA12PSF1 160 - AA18PSF1 160 - BA01PSF1 160 - BA02PSF1 160 - BA03PSF1 160 - BA04PSF1 160 - BA06PSF1 160 - BA10PSF1
Preset Speed Model Catalog Number ➀➂ 160S - AA02PPS1 160S - AA03PPS1 160S - AA04PPS1 160S - AA08PPS1 160 - AA02PPS1 160 - AA03PPS1 160 - AA04PPS1 160 - AA08PPS1 160 - AA12PPS1 160 - AA18PPS1 160 - BA01PPS1 160 - BA02PPS1 160 - BA03PPS1 160 - BA04PPS1 160 - BA06PPS1 160 - BA10PSP1
Drive Ratings Input Voltage Rating 200-240V 50/60 Hz Single-Phase
200-240V 50/60 Hz Three-Phase
380-460V 50/60 Hz Three-Phase kW 0.37 0.55 0.75 1.5 0.37 0.55 0.75 1.5 2.2 4.0 0.37 0.55 0.75 1.5 2.2 4.0
HP 0.5 0.75 1 2 0.5 0.75 1 2 3 5 0.5 0.75 1 2 3 5
➀ The Bulletin 160 comes standard with a Ready/Fault indication panel. To order a drive with a Program Keypad Module installed, add suffix “P1” to the catalog number. For example: Catalog Number 160-AA02NSF1 becomes 160-AA02NSF1P1 ➁ Meets IP54/65/66 (NEMA 12/4/4X) when installed in suitable enclosure. ➂ For pricing information refer to the Bulletin 160 Price Sheet.
5
Page 6
Standard Drives Program Operator Interface & Communication Devices
Accessory
Ready/Fault Indicating Panel - Indicates if the drive is READY for operation or if a FAULT condition has occurred. This module is provided as “standard equipment” when no other factory installed options are ordered.
FAULT READY
FAULT READY
Remote Programming Adapter
DeviceNet FAULT COMM
Description
READY
Catalog Number ➀ 160-B1
Program Keypad Module - Provides the ability to program and/or monitor all drive parameters as well as provide local keypad control (start, stop and reverse functions). See page 5, Footnote 1, for information on how to order this option factory installed.
160-P1
Remote Keypad Module - Provides the ability to mount the operator interface remote from the drive. A Remote Programming Adapter (160-RPA) and cable must be ordered separately.
160-P2
CopyCat Keypad Module - Provides the ability to program or monitor individual drive parameters or upload and download all drive parameters. A Remote Programming Adapter (160-RPA) and cable must be ordered separately.
160-P3
Remote Programming Adapter - Provides a simple interface connection for the Remote and CopyCat Keypad Modules.
160-RPA
Cables - Connects the Remote Programming Adapter to either the Remote or CopyCat Keypad Module. Several different cable lengths and types are available.
See page 8
Communications Module - Allows control and monitoring of parameters via the networks listed below. These modules add 21.4 mm (0.85 in.) to the overall depth of the drive. See page 16 for dimensional information. Communication modules are as follows: • DeviceNet • RS232 Serial Communications • Profibus • Interbus
160-DN2 160-RS1 160-PD1 160-IB1
DriveExplorer™ Software - Windows“ based software package that provides an intuitive means 9306-4KS0EFF for monitoring or configuring Allen-Bradley drives and communications adapters. ➀ For pricing information refer to the Bulletin 160 Price Sheet.
6
Page 7
Standard Drives Program Accessories
Accessory
Ordering Information See Page 8
Dimension Information See Page 14
Capacitor Module - Provides extended ride through capability and increases inherent braking performance. This module connects to the load side power terminals marked DC- and DC+.
See Page 9
See Page 14
Line Filter Module - Reduces conductive emissions to meet EMC compliant installations. The line filters are designed so that the drive can be mounted on top (piggyback) of the line filter module to help reduce overall enclosure size.
See Page 9
See Page 15
Line Reactor - Provides input power conditioning when installed on the line side of the drive, or reflected wave protection when installed on the load side of the drive. When used for reflected wave protection, the reactor should be mounted close to the motor. Consult the 160 Drive User Manual for recommendations on when to use this device.
See Page 8
See Page 15
RWR Module - Reduces potentially destructive reflected wave spikes that can occur in applications with long cable distances between the drive and motor. This device is designed for installation close to the output terminals of the drive. Consult the 160 Drive User Manual for recommendations on when to use this device.
See Page 8
See Publication 1204-5.1
24V DC Interface Module - Allows use of 24V DC “sink logic” control. Two versions are available, one for preset speed models and one for analog signal follower models. The 24V DC interface attaches directly to the drives' control terminal block.
See Page 8
No added panel space is necessary with this device.
Description Dynamic Brake Module - Provides external dynamic braking capability for applications with a duty cycle rating not exceeding 5%. Parameter 52 (DB Enable) must be set to 5% to achieve this performance level. For applications greater than 5%, a resistor package must be properly sized to avoid overheating.
7
Page 8
Standard Drives Program Accessories and Repair Parts – Field Installed Accessories Catalog Number 160-DM-SF1➀ 160-DM-PS1➀ 160-C10R 160-C10 160-C30 160-C50 1321-M001 1321-M009
Repair Parts Description ➅ 24V DC Interface (Analog Model) 24V DC Interface (Preset Model) 1.0 m (3.3 ft.) Cable w/ right angle connector 1.0 m (3.3 ft.) Cable 3.0 m (9.8 ft.) Cable 5.0 m (16.4 ft.) Cable Ferrite core (unwound) Ferrite core (wound)
Drive Ratings
Input Voltage Rating 200-240V, 50/60 Hz, Single-Phase 200-240V, 50/60 Hz, Three-Phase
380-460V, 50/60 Hz, Three-Phase kW 0.37 0.55 0.75 1.5 0.37 0.55 0.75 1.5 2.2 4.0 0.37 0.55 0.75 1.5 2.2 4.0
HP 0.5 0.75 1 2 0.5 0.75 1 2 3 5 0.5 0.75 1 2 3 5
Catalog Number 160-FRK1 160-FRK2 160-FRK3
Description ➅ Fan Replacement Kit, 0.75-2.2 kW (1-3 HP) for Series A or B drives Fan Replacement Kit, 0.75-2.2 kW (1-3 HP) for Series C drives Fan Replacement Kit, 4 kW (5 HP) for Series C drives
Dynamic Brake Module
Line Reactors - Open Style
RWR Module
Catalog Number ➅ – – 160-BMA1 160-BMA2 – – 160-BMA1 160-BMA2 160-BMA2 160-BMA2 ➂ – – 160-BMB1 160-BMB2 160-BMB2 160-BMB2 ➂
Catalog Number ➁➅ – – – – 1321-3R4-B 1321-3R4-A 1321-3R4-A 1321-3R8-A 1321-3R12-A 1321-3R18-A 1321-3R2-B 1321-3R2-A 1321-3R2-A 1321-3R4-B 1321-3R8-B 1321-3R18-B
Catalog Number ➃➅ – – – – – – – – – – 1204-RWR2-09-B 1204-RWR2-09-B 1204-RWR2-09-B 1204-RWR2-09-B 1204-RWR2-09-B 1204-RWR2-09-B ➄
➀ Series B 24V Interface Modules are required for use with Series C Drives. ➁ Catalog numbers listed are for 3% impedance open style units. NEMA Type 1 and 5% impedance reactor types are also available, refer to publication 1321-2.0. ➂ TWO UNITS MUST BE USED, wired in parallel. ➃ Refer to Publication 1204-5.1 for dimensional information on RWR Devices. ➄ The 1204-RWR2-09-B may be used at a 10.5 Amp current rating providing the cable length from drive to motor is less than 122 meters (400 feet). ➅ For pricing information refer to the Bulletin 160 Price Sheet.
8
Page 9
Standard Drives Program Accessories and Repair Parts – Field Installed Drive Ratings
Input Voltage Rating 200-240V, 50/60 Hz, Single-Phase 200-240V, 50/60 Hz, Three-Phase
380-460V, 50/60 Hz, Three-Phase kW 0.37 0.55 0.75 1.5 0.37 0.55 0.75 1.5 2.2 4.0 0.37 0.55 0.75 1.5 2.2 4.0
HP 0.5 0.75 1 2 0.5 0.75 1 2 3 5 0.5 0.75 1 2 3 5
“LF” Line Filter Module
“RF” Line Filter Module
Capacitor Module
Catalog Number ➀➂➃ 160S-LFA1 160S-LFA1 160S-LFA1 160S-LFA1➄ 160-LFA2 160-LFA2 160-LFA2 160-LFA2 160-LFA2 – 160-LFB1 160-LFB1 160-LFB1 160-LFB1 160-LFB1 –
Catalog Number ➁➂➃➅ 160S-RFA-9-A 160S-RFA-9-A 160S-RFA-9-A 160S-RFA-16-B 160-RFB-5-A 160-RFB-5-A 160-RFB-5-A 160-RFB-14-A 160-RFB-14-A 160-RFA-22-B 160-RFB-5-A 160-RFB-5-A 160-RFB-5-A 160-RFB-5-A 160-RFB-14-A 160-RFB-14-B
Catalog Number ➂ 160-CMA1 160-CMA1 160-CMA1 160-CMA1 160-CMA1 160-CMA1 160-CMA1 160-CMA1 160-CMA1 160-CMA1 160-CMB1 160-CMB1 160-CMB1 160-CMB1 160-CMB1 160-CMB1
➀ The 160LF type filters have been tested with a maximum motor cable length of 75 meters (246 feet) for 230V units and 40 meters (131 feet) for 460V units. Refer to the 160 User Manual (publication 0160-5.15) for detailed installation considerations. ➁ The 160RF type filters have been tested with a maximum motor cable length of 25 meters (82 feet) for both 230V and 460V units. Refer to the 160 User Manual for more detailed installation considerations. ➂ For pricing information refer to the Bulletin 160 Price Sheet. ➃ Bulletin 160 Series C drives (with proper filter) meet: – Overall EMC requirements of EN61800-3 for Second (Industrial) Environments – High frequency conducted and radiated emissions of EN61800-3 for (First) Residential Environments – High frequency conducted and radiated emissions of EN55011 for (Second) Industrial Environments ➄ Must mount separately when used with Series C drives. ➅ Must be used with Series C drives.
9
Page 10
Standard Drives Program Bulletin 160 Block Diagram Capacitor Module
Brake Module
BR+
BR–
DC+
DC–
L1/R
T1/U
L2/S
T2/V
L3/T
Frequency Reference Preset Speed Model TB3 -1 TB3 -2 TB3 -3
GND/PE
Analog Model
TB3-1
–10V to +10V or Potentiometer or 4-20 mA
TB3-2
TB3 -4
Reverse Start Programmable Input Common
Motor
T3/W Control Power
Bus Voltage Circuitry
TB3-3 (Common)
GND/PE Current Circuitry
Fault Feedback
TB3-4 CPU
Program Keypad Module
TB3-5 TB3-6 TB3-8 TB3-7
Opto Isolator Relay Circuitry
TB3-9 TB3-10 TB3-11
User Programmable Output
Branch Circuit Block Diagram Short circuit and overload protection are requirements of any motor branch circuit. Input power conditioning, CE conformance, motor cable length and motor cable type (reflected wave and capacitive current coupling considerations) are important considerations of drive applications. Branch Circuit Protective Devices (Consult the 160 User Manual) Input Power Conditioning – See Line Reactor on page 7 Line (EMC) Filter – See page 7 Dynamic Brake Module – See page 7
R/L1 S/L2 T/L3 BR– BR+
Operator Interface or Communication Module –See page 6 ESC SEL
1 2 3 4 5 6 7 8 9 10 11
U/T1 V/T2 W/T3 DC– DC+
Capacitor Module – See page 7 Reflected Wave Protection – See Line Reactor or RWR Module on page 7 Motor Cable Type and Length Recommendations – (Consult the 160 User Manual) Class 10 Overload Protection – provided by the 160 drive Motor – See publication 1329R-1.0
10