Manual · Allen-Bradley
Bulletin 160 "Series C" Smart Speed Controllers Technical Data
Manual28 pagesPDF 2.5 MB
Technical data for the Allen-Bradley Bulletin 160 Series C Smart Speed Controller drives, such as the 160-AA08NSF1 and 160-BA01NPS1.
What this file really is
The old site listed this file as a manual for the Allen-Bradley 160-AA08NSF1, 160-BA01NPS1 and 2 more models. Filed as a user manual, this is the Bulletin 160 Series C technical data publication (selection, specifications and dimensions), not the user manual.
Filed under · 4 models
Filed under these models in the old catalog
Summary
What is in it
Rockwell Automation technical data for the Allen-Bradley Bulletin 160 Series C Smart Speed Controller, a compact variable speed drive for three-phase induction AC motors rated 0.37 to 4 kW (0.5 to 5 HP). It explains the catalog numbers for analog signal follower (such as 160-AA08NSF1 and 160-BA01NSF1) and preset speed (such as 160-BA01NPS1) models, operator interface and communication modules, accessories, block diagrams, specifications, dimensions, parameters, the 160Z drives and packaged drive enclosures.
Its parts
- Standard Drives Program
- Standard Drives Program: 160Z
- Standard Packaged Drive Program
From the manual
Key facts from this manual
Each line names its page in the PDF.
Allen-Bradley technical data for the Bulletin 160 Series C Smart Speed Controller, a small AC drive, covering the open style and chassis mount 160 and 160S drives, the 160Z (IP 65/NEMA 4X) drive and packaged enclosure versions. It lists ratings, keypads, communication modules and other accessories, specifications, and the display and program parameters.
- Device
- Bulletin 160 Series C Smart Speed Controller, a compact variable speed drive for three-phase AC induction motors p. 4
- Control model
- 160-AA08NSF1, 160-BA01NSF1: analog signal follower; 160-BA01NPS1, 160-BA03NPS1: preset speed p. 5
- Output frequency
- 0 to 240 Hz, programmable p. 11
- Analog inputs
- Analog models: 4 to 20 mA (250 ohms), -10 to +10V DC (100k ohms), or 1k to 10k ohm speed potentiometer p. 11
- Preset speeds
- Preset speed models: SW1, SW2, SW3 select 8 preset speeds and 2 accel/decel times p. 12
- Control inputs
- Dry contact inputs from an internal 12V supply (10mA typical); optional 24V DC sink logic interface p. 11
- Relay output
- Form C, resistive 0.4A at 125V AC, 0.2A at 230V AC, 2A at 30V DC; eleven functions p. 12
- Motor protection
- I2t overload, 150% for 60 seconds, 200% for 30 seconds (Class 10) p. 12
- Carrier frequency
- 2 kHz to 8 kHz in 100 Hz steps, 4 kHz default p. 12
- Keypads
- 160-P1 Program Keypad (6 character LED), 160-P2 Remote Keypad (4 character LED), 160-P3 CopyCat (2 line LCD) p. 6, 12
- Remote adapter
- 160-RPA Remote Programming Adapter, needed for the 160-P2 and 160-P3 p. 6
- Network modules
- 160-DN2 DeviceNet, 160-RS1 RS232, 160-PD1 Profibus, 160-IB1 Interbus p. 17
- Storage temperature
- -40 to 85 degrees C (-40 to 185 degrees F) p. 11
- Efficiency
- 97.5% typical p. 11
What this manual walks you through
- Reading a Bulletin 160 catalog number and choosing a drive rating p. 5
- Choosing keypads, the remote adapter and communication modules p. 6
- Choosing brake, filter, reactor, RWR and capacitor modules p. 7, 8, 9
- Control terminal block and branch circuit layout p. 10
- Electrical, environmental and control specifications p. 11, 12
- Communication module specifications p. 17
- Display parameters for monitoring the drive p. 17
- Program parameters and factory defaults p. 18
- Choosing a 160Z drive and its accessories p. 19, 20
Good to know
- The dynamic brake module is for duty cycles up to 5%; above that a resistor package must be sized to avoid overheating. p. 7
- Series B 24V interface modules are required with Series C drives. p. 8
- The LF line filters were tested with motor cables up to 75 m for 230V units and 40 m for 460V units. p. 9
- The chassis mount drives meet IP54/65/66 only when installed in a suitable enclosure. p. 5
- The 160-P1 keypad is not compatible with 160Z drives. p. 20
Questions this manual answers
What is the difference between the 160-BA01NSF1 and the 160-BA01NPS1?
The NSF1 is the analog signal follower model and the NPS1 is the preset speed model. p. 5
How do I order a Bulletin 160 drive with the program keypad installed?
Add the suffix P1 to the catalog number, for example 160-AA02NSF1 becomes 160-AA02NSF1P1. p. 5
Which network modules fit the Allen-Bradley 160 drive?
DeviceNet (160-DN2), RS232 (160-RS1), Profibus (160-PD1) and Interbus (160-IB1). p. 17
How many preset speeds does the 160 preset speed model have?
Inputs SW1, SW2 and SW3 select 8 preset speeds and 2 accel/decel times. p. 12
What is the maximum output frequency of the Bulletin 160?
The output frequency is programmable from 0 to 240 Hz. p. 11
Contents
Chapters and sections
Each line opens the PDF at its page.
- Front Cover1
- Catalog Number Description5
- Product Selection5
- Operator Interface & Communication Devices6
- Accessories7
- Bulletin 160 Block Diagram10
- Branch Circuit Block Diagram10
- Specifications11
- Approximate Dimensions13
- Communication Module Specifications17
- Display Parameter Descriptions17
- Program Parameter Descriptions18
- Catalog Number Description19
- Product Selection19
- Operator Interface & Communication Devices20
- Specifications21
- Approximate Dimensions23
- Ordering Instructions24
- Custom Configured Drives Program24
- Catalog Number Description24
- Product Selection24
- Factory Installed Enclosure Options25
- Option Rules25
- Approximate Dimensions for Enclosures26
- Back Cover28