Bulletin 160 "Series C" Smart Speed Controllers Technical Data, pages 21 to 28

Pages 21 to 28 of 28

The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 160-AA08NSF1, Allen-Bradley 160-BA01NPS1, Allen-Bradley 160-BA01NSF1 and Allen-Bradley 160-BA03NPS1

Page 21

Standard Drives Program – 160Z Specifications 160Z Drive Ratings IP20 Catalog Number Three-Phase Input, 50/60 Hz 200 - 240V 160Z-AA02 160Z-AA03 160Z-AA04 160Z-AA08 160Z-AA12 380 - 460V 160Z-BA01 160Z-BA02 160Z-BA03 160Z-BA04 160Z-BA06 160Z-BA10

Output Ratings

Input Ratings Operating Voltage Range kVA

Dynamic Braking Torque Without External With External Resistor Resistor kW

HP

Output Current

0.37 0.55 0.75 1.5 2.2

0.5 0.75 1 2 3

2.3A 3.0A 4.5A 8.0A 12.0A

180-265V 180-265V 180-265V 180-265V 180-265V

1.4 1.8 2.7 4.0 7.1

100% 100% 100% 50% 50%

– – 200% 150% 115%

0.37 0.55 0.75 1.5 2.2 4.0

0.5 0.75 1 2 3 5

1.2A 1.7A 2.3A 4.0A 5.2A 8.1A

340-506V 340-506V 340-506V 340-506V 340-506V 340-506V

1.4 2.0 2.7 4.7 7.1 12.3

100% 100% 100% 50% 50% 20%

– – 200% 150% 115% 100%

Input/Output Ratings (All Drive Ratings) Output Voltage

Adjustable from 0V to input voltage

Output Frequency

0 to 240 Hz - Programmable

Efficiency

97.5% (Typical)

Transient Protection

Standard 6kV (Series C drives)

Environmental Specifications (All Drive Ratings) Enclosure

IP 65 (NEMA Type 4X)

Ambient Temperature IP 20 IP 66 (NEMA Type 12/4/4X)

0 to 50 degrees C (32 to 122 degrees F) 0 to 40 degrees C (32 to 104 degrees F)

Storage Temperature

–40 to 85 degrees C (–40 to 185 degrees F)

Relative Humidity

Condensing, Dropping Water, Hose Down for maintenance with water, soaped water or acid agents

Vibration

1.0 G Operational - 2.5 G Non-operational

Shock

15 G Operational - 30 G Non-operational

Altitude

1,000 meters (3,300 feet) without derating

Control Inputs Control Input Type

Dry Contact Inputs - Drive has an internal 12 volt power supply that provides 10 mA typical current flow. 24V Inputs -

Start, Stop, Forward/Reverse

24V DC interface on Regulator Board (selectable through jumpers) allows use of 24V DC sinking inputs.

Configurable inputs for 2 or 3 wire control

Control Inputs Analog Input (4 to 20mA)

Input impedance 250 ohms

Analog Input (-10 to +10V DC)

Input impedance 100k ohms

External Speed Potentiometer

1k to 10k ohms, 2 Watt minimum

PI Control

Parameter 46, setting 9 provides PI Control function

SW1, SW2

Parameter 46, setting 8 provides 4 preset speeds and 2 accel/decel times

21

Page 22

Standard Drives Program – 160Z Specifications, Continued Control Output Programmable Output (form C relay contact)

Resistive Rating: 0.4A at 125V AC, 0.2A at 230V AC, 2A at 30V DC Inductive Rating: 0.2A at 125V AC, 0.1A at 230V AC, 1A at 30V DC Programmable for eleven different functions

Control Features PWM Algorithm

Sine weighted PWM with harmonic compensation

Switching Device (3-Phase Output)

IGBT (Insulated Gate Bipolar Transistor)

V/Hz Ratio

Programmable

Carrier Frequency

Adjustable from 2 kHz to 8 kHz in 100 Hz increments (factory default is 4 kHz)

DC Boost

Adjustable - Select from a family of boost curves

Current Limiting

Trip free operation, coordinated for drive and motor protection. Programmable from 1% to 180% of drive Output Current.

Motor Protection

I2t overload protection - 150% for 60 seconds, 200% for 30 seconds (Provides Class 10 overload protection)

Overload Pattern #0

Flat response over speed range (no speed compensation)

Overload Pattern #1

Speed compensation below 25% of base speed

Overload Pattern #2

Speed compensation below 100% of base speed

Acceleration/Deceleration Time(s)

0.1 to 600 seconds

S-Curve Accel/Decel Time(s)

0 to 100% of accel/decel time - not to exceed 60 seconds

Stopping Modes

4 modes (programmable)

Ramp to Stop

0.1 to 600 seconds

Coast

Stops all PWM output

DC Injection Brake

Applies DC voltage to the motor for 0 to 25 seconds

DC Injection Braking w/ Auto Stop

Applies DC voltage to the motor for 0 to 25 seconds with Auto Shutoff

Protective Features Overcurrent

200% hardware limit, 300% instantaneous fault

Excessive Temperature

Embedded temperature sensor trips if heatsink temperature exceeds 95 degrees C (203 degrees F)

Over Voltage Drive Rated Input = 200-240V AC Drive Rated Input = 380-460V AC

DC Bus voltage is monitored for safe operation Overvoltage trip occurs at 400V DC bus voltage (equivalent to 290V AC incoming line voltage). Overvoltage trip occurs at 800V DC bus voltage (equivalent to 575V AC incoming line voltage).

Under Voltage Drive Rated Input = 200-240V AC Drive Rated Input = 380-460V AC

DC Bus voltage is monitored for safe operation Undervoltage trip occurs at 210V DC bus voltage (equivalent to 150V AC incoming line voltage). Undervoltage trip occurs at 390V DC bus voltage (equivalent to 275V AC incoming line voltage).

Control Ride Through

Minimum ride through is 0.5 seconds - typical value 2 seconds

Ground Fault

Protection in both Start and Run Mode

Faultless Ride Through

100 milliseconds

Output Short Circuit

Any output phase to phase short

Programming Programmer Display Type Keypad Controls

22

Optional - External Keypad Module Two Digit Parameter Number and Four Digit Value Speed, Run, Stop and Direction

Page 23

Standard Drives Program – 160Z Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not to be used for manufacturing purposes.

Wall Mount 42.5 (1.70)

185.5 (7.30) 130.0 (5.12)

7.0 (0.28) Diameter - 4 Places

207.5 (8.17)

215.0 (8.46) 235.0 (9.25)

23

Page 24

Standard Packaged Drives Ordering Instructions The Standard Packaged Drive Program allows users to create drive packages based on their specific needs. A complete drive package may be specified by assembling a single catalog number string that includes a base drive, enclosure and all required options.

Ordering Instructions: 1.

Select basic Catalog Number based on application requirements (i.e. Voltage, Horsepower, Control Model and Enclosure Ratings). For example: a 200-240VAC, three-phase, 0.37 kW (0.5 HP), analog signal follower model and a IP66 (NEMA Type 4/12) enclosure. The catalog number is: 160-AA02SF1-AF.

2.

Select Enclosure Options and follow the Option Rules. For example: the catalog number with a fused disconnect switch and Start-Stop pushbuttons is: 160-AA02SF1-AF- DS-D17.

Compliance certifications include: UL/cUL (U.S. & Canada) UL508C CAN/CSA C222 No. 14

CE (Europe) Low Voltage Directive 73/23/EEC EN60204-1 EN50178

EMC Directive 89/336/EEC EN 61800-3 EN 50081-2 EN 50082-2

C-Tick (Australia) AS/NZS2064.1 Important: When the "EMC" option is selected, the product will ship with an RFI "RF" type filter. If the "EMC" option is not selected, reference the Bulletin 160 Series C User Manual for proper installation instructions.

Custom Configured Drives Program Drive packages that cannot be ordered via a catalog number can be customized to meet customer requirements for specific options such as special enclosure sizes and colors, terminal blocks, wire type, etc.

Catalog Number Description

160 – AA02SF1 – Bulletin Number

Drive Rating and Control Model Type (must be specified)

AF

– DS-D17

Enclosure Rating (must be specified)

Options (specify as needed)

Product Selection Drive Ratings Input Voltage Rating 200-240V 50/60 Hz Single-Phase 200-240V 50/60 Hz Three-Phase

380-460V 50/60 Hz Three-Phase

24 kW 0.37 0.55 0.75 1.5 0.37 0.55 0.75 1.5 2.2 4.0 0.37 0.55 0.75 1.5 2.2 4.0

HP 0.5 0.75 1 2 0.5 0.75 1 2 3 5 0.5 0.75 1 2 3 5

Output Current Rating 2.3A 3.0A 4.5A 8.0A 2.3A 3.0A 4.5A 8.0A 12.0A 18.0A 1.2A 1.7A 2.3A 4.0A 6.0A 10.5A

Catalog Number IP66 (NEMA 4/12) Analog Signal Follower Model 160S - AA02SF1-AF 160S - AA03SF1-AF 160S - AA04SF1-AF 160S - AA08SF1-AF 160 - AA02SF1-AF 160 - AA03SF1-AF 160 - AA04SF1-AF 160 - AA08SF1-AF 160 - AA12SF1-AF 160 - AA18SF1-AF 160 - BA01SF1-AF 160 - BA02SF1-AF 160 - BA03SF1-AF 160 - BA04SF1-AF 160 - BA06SF1-AF 160 - BA10SF1-AF

Preset Speed Model 160S - AA02PS1-AF 160S - AA03PS1-AF 160S - AA04PS1-AF 160S - AA08PS1-AF 160 - AA02PS1-AF 160 - AA03PS1-AF 160 - AA04PS1-AF 160 - AA08PS1-AF 160 - AA12PS1-AF 160 - AA18PS1-AF 160 - BA01PS1-AF 160 - BA02PS1-AF 160 - BA03PS1-AF 160 - BA04PS1-AF 160 - BA06PS1-AF 160 - BA10PS1-AF

IP66 (NEMA 4X - 304 Stainless Steel) Analog Signal Follower Model Preset Speed Model 160S-AA02SF1-AS 160S - AA02PS1-AS 160S-AA03SF1-AS 160S - AA03PS1-AS 160S-AA04SF1-AS 160S - AA04PS1-AS 160S-AA08SF1-AS 160S - AA08PS1-AS 160-AA02SF1-AS 160 - AA02PS1-AS 160-AA03SF1-AS 160 - AA03PS1-AS 160-AA04SF1-AS 160 - AA04PS1-AS 160-AA08SF1-AS 160 - AA08PS1-AS 160-AA12SF1-AS 160 - AA12PS1-AF 160-AA18SF1-AS 160 - AA18PS1-AS 160-BA01SF1-AS 160 - BA01PS1-AS 160-BA02SF1-AS 160 - BA02PS1-AS 160-BA03SF1-AS 160 - BA03PS1-AS 160-BA04SF1-AS 160 - BA04PS1-AS 160-BA06SF1-AS 160 - BA06PS1-AS 160-BA10SF1-AS 160 - BA10PS1-AS

Page 25

Standard Packaged Drives Factory Installed Enclosure Options Description Operator Interface DeviceNet Module➀ Serial Communication Module Profibus Module (Drive Mounted) Interbus Module (Drive Mounted) DeviceNet I/O Relay 24 DC Input / Replay Output with 5 point DeviceNet Connector

Ready/Fault Panel Program Keypad Module (Drive Mounted) Remote Programming Adapter Remote Keypad Module Fused Disconnect Switch (Class J Fuses) Cover Mounted Devices: “Hand-Off-Auto” Selector Switch “Start-Stop” Push Buttons “Forward/Reverse” Selector Switch “Local/Remote” Selector Switch White “Drive Run” Pilot Light➂ Red “Drive Fault” Pilot Light➂ “Speed” Potentiometer

Option Code ➉

Cannot be used with

- DN2C - RS1C - PDIC - IB1C - DNRC➆ -➁ - P1C - RPAC - P2C➃➆ - DS

P1C, RS1C, Ready/Fault, RPAC, -P2C, -D17 DN2C, PIC, Ready/Fault, RPAC, -P2C, -D17 DN2C, PIC, RS1C, Ready Fault, RPAC, P2C, D17, IB1C P1C, RS1C, Ready Fault, RPAC, P2C, D17, PR1C, DN2C

- D13 - D17 - D32➈ - D33 - D35 - D36 - D61 “Local/Remote” & “Local Control Off/Run Forward” 800T Selector Switches - MX12 “Local/Off/Remote” 800T Selector Switch with One N.O. Interposing Relay - MX19 Control Interface Cards: 24V DC Interface Card for Analog Drive - DMSF1C 24V DC Interface Card for Preset Speed Drive - DMPS1C 120V AC Interface Module for Analog and Preset Speed Drives - LNT120➇ DeviceNet Enclosure Mounted Connector Options➄: - DNSC1➅ Nema 4/12 5 pin connector side mounted - DNSC2➅ Nema 4x 5 pin connector side mounted - DNBC1➅ Nema 4/12 5 pin connector bottom mounted - DNBC2➅ Nema 4x 5 pin connector bottom mounted Electro Magnetic Compatibility - EMC➆ Motor Brake Option: Motor Brake Contactor and Surge Supressor (100M cont. 24V powered off DeviceNet Option) - MX14➅➆ ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉

DN2C, P1C, RS1C, RPAC, -P2C DN2C, RS1C, Ready/Fault, RPAC, -P2C, D17 DN2C, RS1C, Ready/Fault, P1C, P2C, -D17 DN2C, RS1C, Ready/Fault, P1C, RPAC, -D17, D33

- D17, D33, MX12, MX19 - D13, D33, MX12, MX19, DN2C, P1C, RS1C, RPAC, P2C - MX12, MX19 - D13, D17, MX12, MX19 - D36, MX12, MX19 - D35, MX12, MX19 - MX12, MX19, All Preset Speed Models - D13, D17, D32, D33, D35, D36, D61, AS, MX19 - D13, D17, D32, D33, D35, D36, D61, MX12, MX14, 45, AS

DMPS1C, LTN120, All Preset Speed Models DMFS1C, LTN120, All Analog Models DMPS1C, DMSF1C DNSC2, DNBC1, DNBC2, P1C, RS1C, RPAC, P2C, STD READY FAULT DNSC1, DNBC1, DNBC2, P1C, RS1C, RPAC, P2C, STD READY FAULT DNSC1, DNSC2, DNBC2, P1C, RS1C, RPAC, P2C, STD READY FAULT DNSC1, DNSC2, DNBC1, P1C, RS1C, RPAC, P2C, STD READY FAULT

-LTN120

D35, D36, MX19, P1C, RS1C, RPAC, P2C, Ready Fault

Includes 10 point DeviceNet Connector. If a (-P1C), (-DN2C), (RS1C), (RPAC) or (P2C) is not specified, the drive is supplied with a factory installed “Ready/Fault” indicating panel as standard. 120V AC Separate Control Power Required. Remote Keypad Module option includes the RPA and cable. 5 pin DeviceNet Connectors are Brad Harrison type. Female connector #1A5000-34 User supplied. See Dimensions/locations page 27. DN2C option must be selected. See page 27 for connector locations. Enclosure dimensions with or without disconnect: 0.5-2 HP 8.44W x 17H x 9.15D; 3 HP 9.61W x 16.5H x 9.46D Option is not CE/C-Tick. When catalog string contains a communication module, D32 must be used with D33 or except with option P2C. When used with option P2C, must be used with D13. For pricing information refer the Bulletin 160 Price Sheet.

Option Rules Option Maximum Number of Cover Devices

Description 0.37-1.5 kW (0.5-2 HP) without a disconnect or Remote Keypad Module or MX14 or EMC is 4. 2.2-4 kW (3-5 HP) w/o a disconnect or Remote Keypad Module and all drives with a disconnect, MX14 or EMC is 5.

Factory Installed Enclosure Option Catalog Configuration

0.37-4.0 kW (3-5 HP) with the Remote Keypad Module is 3. i.e. Start-Stop (D17) = 2 Cover Devices Forward-Reverse (D32) = 1 Cover Device White Run Pilot Light (D35) = 1 Cover Device = 4 Total When ordering, build the catalog string in the following manner: Bulletin number, drive rating, control model, enclosure type and options. Note: Options are to be configured in alpha-numeric sequence.

25

Page 26

Standard Packaged Drives Approximate Dimensions for 160 NEMA Type 4/12 & 4X Stainless Steel Enclosures Figure 1 0.37 kW-0.75 kW (0.5-1 HP), Single-Phase, 200-240V AC (without DS, P2C, LTN120, MX14 or EMC) 0.37 KW-1.5 kW (0.5-2 HP), Three-Phase, 200-240V AC and 380-460V AC (without DS, P2C, LTN120, MX14 or EMC) .37 -.75 without the following options: DS, P2C, LTN120, MX14. 7.6 (0.30) 14.5 (0.57)

175.0 (6.89) 160.0 (6.30) 146.0 (5.75)

157.0 (6.18)

54.6 (2.15)

36.3 46.2 (1.43) (1.82)

190.0 (7.48)

Position 1

Position 2

210.1 (8.27) Window Bulletin 160

292.1 (11.50)

5.6 (0.22) Diameter - 4 Places

Position 3

Position 4

Enclosure Door

Figure 2 0.37 kW-0.75 kW (0.5-1 HP), Single-Phase, 200-240V AC (without DS, P2C, LTN120, MX14 or EMC) 0.37 KW-1.5 kW (0.5-2 HP), Three-Phase, 200-240V AC and 380-460V AC (without DS, P2C, LTN120, MX14 or EMC) with the following options: DS, P2C, LTN120, MX14.

20.1 (0.79)

214.4 (8.44) 174.8 (6.88)

27.4 (1.08)

160.0 (6.30)

40.4 (1.59)

177.8 (7.00)

54.6 (2.15)

12.7 (0.50) 38.1 (1.50)

142.0 (5.59) 406.4 (16.00) 419.1 (16.50) 431.8 (17.00)

Position1 Position2

210.1 (8.27)

Window

38.1 (1.50)

Position 3 Position 4 Position 5

Enclosure Door 6.4 12.7 (0.25) (0.50)

5.6 (0.22) Diameter - 4 Places

6.9 (0.27)

Figure 3 2.2 kW (3 HP), Three-Phase, 200-240V AC and 380-460VAC (with and without DS or with P2C, LTN120, MX14 or EMC) 7.1 (0.28) 6.1 (0.25)

244.1 (9.61) 229.9 (9.05)

40.4 (1.59)

177.8 (7.00) 12.7 (0.50)

62.5 (2.46) 38.1 (1.50)

183.6 (7.23)

142.0 (5.59)

419.1 (16.50) Position 1 Position 2

190.0 (7.48)

Window

Position 3 Position 4 Position 5

5.6 (0.22) Diameter - 6 Places

26

Enclosure Door

210.1 (8.27)

Page 27

Standard Packaged Drives Approximate Dimensions, Continued Dimensions are shown in millimeters (inches). Dimensions are not to be used for manufacturing purposes. Figure 4 1.5 kW (2 HP), Single-Phase, 200-240V AC (with DS, P2C, LTN120, MX14 or EMC) 4 kW (5 HP), Three-Phase, 200-240V/380-460V AC (with DS, P2C, LTN120, MX14 or EMC)

DeviceNet Connector Option Locations Figure 5 DNSC1 and DNSC2 187.2 (7.37) 177.8 (7.00)

157.0 (6.18)

454.4 (17.89)

406.4 (16.00) 292.1 (11.50) Ø 22.4 (0.88)

177.8 (7.00)

85.6 (3.37)

Ø 22.4 (0.88)

177.8 (7.00)

50.8 (2.00)

81.3 (3.20)

70.9 (2.79)

Ø 22.4 (0.88)

DNBC1 and DNBC2

187.5 (7.38)

177.8 (7.00)

85.9 (3.38)

157.0 (6.18)

81.3 (3.20) 129.8 (5.11)

259.8 (10.23)

Ø 22.4 (0.88)

70.9 (2.79) 107.2 214.4 (8.44)

Ø 22.4 (0.88)

146.1 (5.75)

Ø 22.4 (0.88)

27

Page 28

The Allen-Bradley Bulletin 160 Smart Speed Controller (SSC) is a world class product that provides the application flexibility needed to meet today’s changing plant floor environment. Its simplistic design will help save time and money in set-up, integration and maintenance of your automation system. For Allen-Bradley drives support, there are specialists at local sales offices and distributor locations across North America and around the world. We also offer global technical services, specializing in a full spectrum of value-added services and expertise to help simplify maintenance and enhance productivity. Rockwell Automation is committed to helping you meet everchanging customer demands for more, less expensive product in less time. Our capabilities enable us to become your “Complete Automation™” partner.

SSC, DriveExplorer, Complete Automation and the Complete Automation graphic are trademarks of Rockwell Automation. Windows is a registered trademark of the MicroSoft Corporation. DeviceNet is a trademark of the Open DeviceNet Vendor Association.

www.rockwellautomation.com Corporate Headquarters Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, 53202-5302 USA, Tel: (1) 414.212.5200, Fax: (1) 414.212.5201 Headquarters for Allen-Bradley Products, Rockwell Software Products and Global Manufacturing Solutions Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444 Europe/Middle East/Africa: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640 Asia Pacific: Rockwell Automation, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846 Headquarters for Dodge and Reliance Electric Products Americas: Rockwell Automation, 6040 Ponders Court, Greenville, SC 29615-4617 USA, Tel: (1) 864.297.4800, Fax: (1) 864.281.2433 Europe/Middle East/Africa: Rockwell Automation, Brühlstraße 22, D-74834 Elztal-Dallau, Germany, Tel: (49) 6261 9410, Fax: (49) 6261 17741 Asia Pacific: Rockwell Automation, 55 Newton Road, #11-01/02 Revenue House, Singapore 307987, Tel: (65) 6356-9077, Fax: (65) 6356-9011 U.S. Allen-Bradley Drives Technical Support Tel: (1) 262.512.8176, Fax: (1) 262.512.2222, Email: support@drives.ra.rockwell.com, Online: www.ab.com/support/abdrives

Publication 0160-TD001F-EN-P, August 2003 Supercedes 0160-TD001E-EN-P, November 2002

Copyright ® 2003 Rockwell Automation, Inc. All rights reserved. Printed in USA.