Page 11
Standard Drives Program Specifications Drive Ratings IP20 Catalog Number Single-Phase Input, 50/60 Hz 200 - 240V 160S-AA02 160S-AA03 160S-AA04 160S-AA08 – – 380 - 460V – – – – – –
Output Ratings
Input Ratings
Three-Phase Input, 50/60 Hz kW
HP
Output Current
Operating Voltage Range kVA
Dynamic Braking Torque Without With External External Resistor Resistor
Power Dissipation
160-AA02 160-AA03 160-AA04 160-AA08 160-AA12 160-AA18
0.37 0.55 0.75 1.5 2.2 4.0
0.5 0.75 1 2 3 5
2.3A 3.0A 4.5A 8.0A 12.0A 18.0A
180-265V 180-265V 180-265V 180-265V 180-265V 180-265V
1.4 1.8 2.7 4.0 7.1 10.6
100% 100% 100% 50% 50% 20%
– – 200% 150% 115% 100%
20W 25W 35W 74W 107W 137W
4W 5W 10W 15W 20W –
160-BA01 160-BA02 160-BA03 160-BA04 160-BA06 160-BA10
0.37 0.55 0.75 1.5 2.2 4.0
0.5 0.75 1 2 3 5
1.2A 1.7A 2.3A 4.0A 6.0A 10.5A
340-506V 340-506V 340-506V 340-506V 340-506V 340-506V
1.4 2.0 2.7 4.7 7.1 12.3
100% 100% 100% 50% 50% 20%
– – 200% 150% 115% 100%
25W 30W 37W 50W 77W 120W
4W 5W 8W 15W 20W –
IP20 (Open Style)
IP 20 (Chassis Mount)
Input/Output Ratings (All Drive Ratings) Output Voltage
Adjustable from 0V to input voltage
Output Frequency
0 to 240 Hz - Programmable
Efficiency
97.5% (Typical)
Transient Protection
Standard 6kV (Series C drives)
Environmental Specifications (All Drive Ratings) Enclosure
IP 20/IP66 (NEMA Type 12/4/4X)
Ambient Temperature IP 20 IP 66 (NEMA Type 12/4/4X)
0 to 50 degrees C (32 to 122 degrees F) 0 to 40 degrees C (32 to 104 degrees F)
Storage Temperature
–40 to 85 degrees C (–40 to 185 degrees F)
Relative Humidity
0 to 95% (non condensing)
Vibration
1.0 G Operational - 2.5 G Non-operational
Shock
15 G Operational - 30 G Non-operational
Altitude
1,000 meters (3,300 feet) without derating
Control Inputs Control Input Type
For dry contact closure input - drive has an internal 12V power supply that provides10mA (typical) current. Also accepts open collector/solid-state input with maximum leakage current of 50µA. Optional 24V DC interface allows use of 24V DC “sink logic” inputs.
Start, Stop, Forward/Reverse
Configurable inputs for 2 or 3 wire control
Control Inputs (Analog Signal Follower Model Only) Analog Input (4 to 20mA)
Input impedance 250 ohms
Analog Input (-10 to +10V DC)
Input impedance 100k ohms
External Speed Potentiometer
1k to 10k ohms, 2 Watt minimum
PI Control
Parameter 46, setting 9 provides PI Control function
SW1, SW2
Parameter 46, setting 8 provides 4 preset speeds and 2 accel/decel times
11
Page 12
Standard Drives Program Specifications, Continued Control Inputs (Preset Speed Model Only) SW1, SW2, SW3
Configurable inputs for control of 8 preset speeds and 2 accel/decel times
Control Output Programmable Output (form C relay contact)
Resistive Rating: 0.4A at 125V AC, 0.2A at 230V AC, 2A at 30V DC Inductive Rating: 0.2A at 125V AC, 0.1A at 230V AC, 1A at 30V DC Programmable for eleven different functions
Control Features PWM Algorithm
Sine weighted PWM with harmonic compensation
Switching Device (3-Phase Output)
IGBT (Insulated Gate Bipolar Transistor)
V/Hz Ratio
Programmable
Carrier Frequency
Adjustable from 2 kHz to 8 kHz in 100 Hz increments (factory default is 4 kHz)
DC Boost
Adjustable - Select from a family of boost curves
Current Limiting
Trip free operation, coordinated for drive and motor protection. Programmable from 1% to 180% of drive Output Current.
Motor Protection
I2t overload protection - 150% for 60 seconds, 200% for 30 seconds (Provides Class 10 overload protection)
Overload Pattern #0
Flat response over speed range (no speed compensation)
Overload Pattern #1
Speed compensation below 25% of base speed
Overload Pattern #2
Speed compensation below 100% of base speed
Acceleration/Deceleration Time(s)
0.1 to 600 seconds
S-Curve Accel/Decel Time(s)
0 to 100% of accel/decel time - not to exceed 60 seconds
Stopping Modes
4 modes (programmable)
Ramp to Stop
0.1 to 600 seconds
Coast
Stops all PWM output
DC Injection Brake
Applies DC voltage to the motor for 0 to 25 seconds
DC Injection Braking w/ Auto Stop
Applies DC voltage to the motor for 0 to 25 seconds with Auto Shutoff
Protective Features Overcurrent
200% hardware limit, 300% instantaneous fault
Excessive Temperature
Embedded temperature sensor trips if heatsink temperature exceeds 95 degrees C (203 degrees F)
Over Voltage Drive Rated Input = 200-240V AC Drive Rated Input = 380-460V AC
DC Bus voltage is monitored for safe operation Overvoltage trip occurs at 400V DC bus voltage (equivalent to 290V AC incoming line voltage). Overvoltage trip occurs at 800V DC bus voltage (equivalent to 575V AC incoming line voltage).
Under Voltage Drive Rated Input = 200-240V AC Drive Rated Input = 380-460V AC
DC Bus voltage is monitored for safe operation Undervoltage trip occurs at 210V DC bus voltage (equivalent to 150V AC incoming line voltage). Undervoltage trip occurs at 390V DC bus voltage (equivalent to 275V AC incoming line voltage).
Control Ride Through
Minimum ride through is 0.5 seconds - typical value 2 seconds
Ground Fault
Protection in both Start and Run Mode
Faultless Ride Through
100 milliseconds
Output Short Circuit
Any output phase to phase short
Programming Programmer / Display Type
Program Keypad Module - 6 character LED display Remote Keypad Module - 4 character LED display CopyCat Keypad Module - 2 line, 16 character LCD display
Local Controls
SPEED, RUN, STOP, and DIRECTION controls
12
Page 13
Standard Drives Program Analog Signal Follower and Preset Speed Models - Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not to be used for manufacturing purposes. 0.37 kW-2.2 kW (0.5-3 HP), Three-Phase, 200-240V AC & 380-460V AC 0.37 kW-0.75 kW (0.5-1 HP), Single-Phase, 200-240V AC
Mounting Holes 4.5 (0.18) - 4 Places
Approximate Weight is 0.94 kg (2.07 lbs.)
80.0 (3.15) 165.4 (6.51)
60.0 (2.36)
60.0 (2.36)
R/L1 S/L2 T/L3 BR– BR+
130.0 (5.12)
83.3 (3.28) ESC SEL
152.0 (6.00)
1 2 3 4 5 6 7 8 9 10 11
U/T1 V/T2 W/T3 DC– DC+
28.2 (1.11)
101.9 (4.01)
60.0 (2.36)
4.0 kW (5 HP), Three-Phase, 200-240V AC & 380-460V AC 1.5 kW (2 HP), Single-Phase, 200-240V AC
Approximate Weight is 2.37 kg (5.23 lbs.)
92.0 (3.62) Mounting Holes 5.5 (0.22) - 4 Places
81.0 (3.19)
193.3 (7.61)
60.0 (2.36)
129.8 (5.11)
R/L1 S/L2 T/L3 BR– BR+
180.1 (7.09)
ESC SEL
192.5 (7.58)
111.5 (4.39)
1 2 3 4 5 6 7 8 9 10 11
U/T1 V/T2 W/T3 DC– DC+
39.1 (1.54) 60.0 (2.36)
*
NOTE: 12.7 mm (0.50 in.) is required around the top, bottom and front of all drives. No clearance is required between drives with the exception of the 2.2 kW (3 HP) rating which requires 8.4 mm (0.33 in.).
13
Page 14
Standard Drives Program Approximate Dimensions, Continued Dimensions are shown in millimeters (inches). Dimensions are not to be used for manufacturing purposes. Chassis Mount, All Ratings
Approximate Weight is 7.26 kg (16 lbs.) through 1.5 kW (2 HP) and 7.71 kg (17 lbs.) for 2.2 kW (3 HP) Rating
Width
0.37-.75 kW (0.5-1 HP) 0.37-1.5 kW (0.5-2 HP) 2.2 kW (3 HP) 1.5 kW (2 HP) 4.0 kW (5 HP)
130.1 (5.12) 114.1 (4.49)*
Width
Depth
1 3 3 1 3
175.0 (6.84) 175.0 (6.89) 244 (9.61) 244 (9.61) 244 (9.61)
54.7 (2.15) 54.7 (2.15) 63.12 (2.48) 96 (3.78) 96 (3.78)
112.0 (4.41) 140.0 (5.51) w/DeviceNet Module
98.0 (3.86)
97.5 (3.84)
Phase
Depth
R/L1 S/L2 T/L3 BR– BR+
195.1 (7.68)
179.1 (7.05)*
210.0 (8.27)
ESC SEL
210.1 (8.27) 1 2 3 4 5 6 7 8 9 10 11
U/T1 V/T2 W/T3 DC– DC+
*Cutout Dimension Customer Panel
5.0 (0.20) Diameter - 6 Places
Dynamic Brake Module 71.2 (2.83) 48.2 (1.97)
Capacitor Module 8.0 (0.32)
13.9 (0.55)
86.4 (3.40)
50.0 (1.97) 40.0 (1.57)
7.5 (0.30)
4.5 (0.18) Dia. - 4 Places 110.9 (4.37)
WARNING
140.0 (5.51)
A B
150.9 (5.94)
130.0 (5.11)
DANGER
+ – GND BR BR
27.9 (1.14) 5.8 (0.23) Dia. 4 Places
11.9 (0.47)
Catalog Number
A
160-BMA1, -BMB1 245.0 (9.64) 160-BMA2, -BMB2 334.0 (13.15)
14
254.0 (10.00) Approximate Lead Length B
225.0 (8.86) 314.0 (12.36)
Page 15
Standard Drives Program Approximate Dimensions, Continued Dimensions are shown in millimeters (inches). Dimensions are not to be used for manufacturing purposes. Line Reactor Catalog Number 1321-3R2-A 1321-3R2-B 1321-3R4-A 1321-3R4-B 1321-3R8-A 1321-3R8-B 1321-3R12-A 1321-3R18-A 1321-3R18-B
A B
E
D C
A 112 (4.40) 112 (4.40) 112 (4.40) 112 (4.40) 152 (6.00) 152 (6.00) 152 (6.00) 152 (6.00) 152 (6.00)
B 104 (4.10) 104 (4.10) 104 (4.10) 104 (4.10) 127 (5.00) 127 (5.00) 127 (5.00) 133 (5.25) 133 (5.25)
C 74 (2.90) 74 (2.90) 76 (3.00) 76 (3.00) 76 (3.00) 76 (3.00) 76 (3.00) 79 (3.10) 86 (3.40)
D 50 (1.98) 50 (1.98) 50 (1.98) 50 (1.98) 53 (2.10) 53 (2.10) 53 (2.10) 51 (2.00) 63 (2.48)
E 37 (1.44) 37 (1.44) 37 (1.44) 37 (1.44) 51 (2.00) 51 (2.00) 51 (2.00) 51 (2.00) 51 (2.00)
Line Filter Module
D 60.0 (2.36)
C
200.0 (7.87) Approximate Lead Length
F
A B
Catalog Number A 160S-RFA-9-A 182 (7.17) 160-RFB-5-A 182 (7.17) 160-RFB-14-A 182 (7.17) 160-RFB-14-B 227 160-RFA-22-B (8.94) 160-RFA-16-B 160S-LF (All) 174 160-LF (All) (6.85)
B 163 (6.42) 163 (6.42) 163 (6.42) 212 (8.35)
C 37.5 (1.47) 37.5 (1.47) 47.5 (1.87) 55.5 (2.18)
D 75 (2.95) 75 (2.95) 75 (2.95) 87 (3.43)
E M4.5 x 6.5 (0.18 x 0.26) M4.5 x 6.5 (0.18 x 0.26) M4.5 x 6.5 (0.18 x 0.26) M4.5 (0.18)
F 6.6 x 4.5 (0.26 x 0.18) 2 Places 6.6 x 4.5 (0.26 x 0.18) 2 Places 6.6 x 4.5 (0.26 x 0.18) 2 Places 6.6 x 4.5 (0.26 x 0.18) 2 Places
163 (6.42)
50.0 (1.97)
75 (2.95)
6.9 x 5.3 7.0 x 5.3 (0.27 x 0.21) (0.28 x 0.21)
E
Three-Phase filter shown (single-phase filter is the same size)
15
Page 16
Standard Drives Program Approximate Dimensions, Continued Dimensions are shown in millimeters (inches). Dimensions are not to be used for manufacturing purposes. DeviceNet and RS-232 Module
MADE IN U.S.A.
SER
67.5 (2.68)
RS232 Serial Comm READY
CAT
COMM
➀ Required for module removal. ➁ Module adds this dimension to the overall drive depth.
160-RS1
FAULT
➁ 21.4 (0.85)
➀ 17.34 (0.68)
70.0 (2.76)
Remote Keypad Module
35.1 (1.38) 11.4 (0.45)
128.5 (5.06)
5.0 (0.20)
100.0 (3.94)
7.5 (0.30)
90.0 (3.54) 168.1 (6.62)
129.3 (5.09) PROGRAM
ESC
RUN
FORWARD
REVERSE
70.0 (2.76) 135.0 (5.32)
SEL
140.0 (5.51)
3.0 (0.12) maximum thickness 4.0 (0.16) diameter, 6 places
16
Page 17
Standard Drives Program Communication Module Specifications Specification Electrical Supply Voltage Power Consumption Network Input Current
DeviceNet (160-DN2)
RS232 (160-RS1)
Profibus (160-PD1)
Interbus (160-IB1)
Network Supply Voltage 11-25V DC 1 Watt 40 mA Maximum
Supplied by drive 1.25 Watts Maximum NA
Supplied by drive 1.25 watts maximum NA
Supplied by drive 1.25 watts maximum NA
125, 250, 500 KBPS NA DeviceNet No No Yes Yes No Yes NA
1200, 2400, 4800, 9600 BPS BCC or CRC DF1 Point to Point, DF1 Multidrop NA NA NA NA NA NA NA
Autobaud 9.Kb to 12Mb NA Profibus -DP NA NA NA NA No Yes Yes
500Kb NA Interbus S DRIVECOM 20 (21) NA NA NA NA No Yes Yes
0 to 50 degrees C (32 to 122 degrees F) –40 to 85 degrees C (–40 to 185 degrees F) 0 to 95% non-condensing 1.0 G Operational, 2.5 G Non-Operational 15.0 G Operational, 30.0 G Non-Operational 1,000 meters (3,300 feet) without derating
0 to 50 degrees C (32 to 122 degrees F) –40 to 85 degrees C (–40 to 185 degrees F) 0 to 95% non-condensing 1.0 G Operational, 2.5 G Non-Operational 15.0 G Operational, 30.0 G Non-Operational 1,000 meters (3,300 feet) without derating
0 to 50 degrees C (32 to 122 degrees F) –40 to 85 degrees C (–40 to 185 degrees F) 0 to 95% non-condensing 1.0 G Operational, 2.5 G Non-Operational 15.0 G Operational, 30.0 G Non-Operational 1,000 meters (3,300 feet) without derating
0 to 50 degrees C (32 to 122 degrees F) –40 to 85 degrees C (–40 to 185 degrees F) 0 to 95% non-condensing 1.0 G Operational, 2.5 G Non-Operational 15.0 G Operational, 30.0 G Non-Operational 1,000 meters (3,300 feet) without derating
Communications Baud Rates CheckSum Protocol Explicit Peer-to-Peer Messaging I/O Peer-to-Peer Messaging Configuration Consistency Value Faulted Node Recovery Master/Scanner I/O Slave Messaging Slave Telegram
Environmental Ambient Operating Temperature Ambient Storage Temperature Relative Humidity Vibration Shock Vibration
Display Parameter Descriptions Parameter Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Parameter Name Output Frequency Output Voltage Output Current Output Power Bus Voltage Frequency Command Last Fault Heatsink Temperature Controller Status Controller Type Control Version Input Status Power Factor Angle Memory Probe Display Preset Status Analog Input Fault Buffer 0 Fault Buffer 1 Fault Buffer 2
Description 0.0 to 240.0 Hz 0 to max voltage 0 to 2 times drive rated output current in units of 0.01A 0 to 2 times drive rated output power in units of 0.01kW 0V to 410V for 230V controllers, 0V to 815V for 460V controllers 0.0 to 240.0 Hz Retains faults for troubleshooting 69 to 150 degrees C (156 to 302 degrees F) Running, forward, accelerating, decelerating Used by Rockwell Automation field service personnel Displays firmware version Displays the status of start, stop, and reverse discrete inputs 0.0 to 90.0 degrees Used by Rockwell Automation field service personnel Displays the status of preset speed discrete inputs Displays the analog input as a percent of full scale Stores the last fault that occurred Stores the second most recent fault that occurred Stores the third most recent fault that occurred
Units 0.1 Hz 1 Volt 0.01 Amps 0.01 kW 1 Volt 0.1 Hz Numeric Value 1 Degree C Binary Number Numeric Value Numeric Value Binary Number 0.1 Degrees Numeric Value Binary Number 0.1% Numeric Value Numeric Value Numeric Value
17
Page 18
Standard Drives Program Program Parameter Descriptions Parameter Number 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 78 79 80 81 82 83 84
18
Parameter Name Accel Time 1 Decel Time 1 Minimum Frequency Maximum Frequency Stop Mode Select Base Frequency Base Voltage Maximum Voltage Boost Select Skip Frequency Skip Frequency Band Motor Overload Select Motor Overload Current Current Limit DC Hold Time DC Hold Voltage Input Mode Output Configure Output Threshold PWM Frequency Restart Tries Restart Time DB Enable S-Curve Clear Fault Memory Probe Address Reset Functions Program Lock Internal Frequency Frequency Select Zero Offset Preset Frequency 0 Preset Frequency 1 Preset Frequency 2 Preset Frequency 3 Preset Frequency 4 Preset Frequency 5 Preset Frequency 6 Preset Frequency 7 Accel Time 2 Decel Time 2 IR Compensation Slip Compensation Reverse Disable Analog Select Analog Input Minimum Analog Input Maximum Compensation Software Current Trip Stall Fault Time PI Proportional Gain PI Integral Gain PI Process Reference PI Dead Band
Description 0.0 to 600.0 seconds 0.1 to 600.0 seconds 0 to 240 Hz 0 to 240 Hz Four settings - Ramp, Coast, DC injection braking, DC Injection w/ auto shut off 10 to 240 Hz 20 to 230V for 230V drives, 20 to 460V for 460V drives 20 to 255V for 230V drives, 20 to 510V for 460V drives 8 boost settings, 4 fan/pump curves 0 to 240 Hz 0 to 30 Hz Three settings - No derating, Min derating, Max derating 25 to 200% of drive rated current in units of 0.01 amps 1 to 180% of drive rated current 0 to 25 seconds 0 to 115V Configurable terminal block provides 10 different control schemes 11 different settings for a variety of drive status conditions 0 to 815 2.0 to 8.0 kHz 0 to 9 0.5 to 300.0 seconds Used to set percent duty cycle for external dynamic braking 0 to 100% accel/decel smoothing Resets faults Used by Rockwell Automation personnel Used to reset drive to factory default settings or update input mode Protects user settings 0.0 to 240.0 Hz Selects source of frequency (internal or external) Used to add or subtract any system offset to analog input 0.0 to 240.0 Hz 0.0 to 240.0 Hz 0.0 to 240.0 Hz 0.0 to 240.0 Hz 0.0 to 240.0 Hz 0.0 to 240.0 Hz 0.0 to 240.0 Hz 0.0 to 240.0 Hz 0.1 to 600.0 seconds 0.0 to 600.0 seconds 0 to 150% 0.0 to 5.0 Hz Disables Reverse Input Used to select between unipolar and bipolar inputs Sets the percent of analog input to represent Minimum Frequency Sets the percent of analog input to represent Maximum Frequency Compensates for Motor Instability or Resonance Software instantaneous current trip Selects amount of time the drive is in a stall condition prior to a fault occurring Proportional Response of PI Regulator Integral Gain of PI Regulator PI will regulate to this setpoint value PI will ignore errors less than this value
Factory Default 10.0 10.0 0 60 Ramp 60 230/460 230/460 2 240 0 No derating 115 150 0.0 0 Three-wire 0 0 4.0 0 10.0 Disable 0 0 0 0 0 60 External 0 3 20 30 40 45 50 55 60 20 20 50 2 0 0 0 100 0 0 0 0.01 0.01 0 0
Page 19
Standard Drives Program – 160Z Catalog Number Description
160Z – Bulletin Number
AA02
F
S
N
N➀
N
Drive Rating (must be specified)
Enclosure Rating (must be specified)
Control Method (must be specified)
Filter Option (must be specified)
Communication (Future Option)
Motor (Optional)
Product Selection Drive Rating Input Voltage Rating 200-240V, 50/60 Hz, Three-Phase
380-460V, 50/60 Hz, Three-Phase kW 0.37 0.55 0.75 1.5 2.2 0.37 0.55 0.75 1.5 2.2 4
HP 0.5 0.75 1 2 3 0.5 0.75 1 2 3 5
Catalog Number Output Current Rating 2.3A 3A 4.5A 8A 12A 1.2A 1.7A 2.3A 4A 5.2A 8.1A without Motor➁ 160Z-AA02FSNNN 160Z-AA03FSNNN 160Z-AA04FSNNN 160Z-AA08FSNNN 160Z-AA12FSNNN 160Z-BA01FSNNN 160Z-BA02FSNNN 160Z-BA03FSNNN 160Z-BA04FSNNN 160Z-BA06FSNNN 160Z-BA10FSNNN with Integral CE Filter, - - - - 160Z-BA01FSFNN 160Z-BA02FSFNN 160Z-BA03FSFNN 160Z-BA04FSFNN 160Z-BA06FSFNN 160Z-BA10FSFNN
➀ When using 160Z as wall mount, communication modules should be ordered as separate options. See page 20. ➁ For 160Z drives mounted on motors, consult factory.
19
Page 20
Standard Drives Program – 160Z Operator Interface➀ & Communication Devices Accessory Remote Keypad Module 160-P2
CopyCat Keypad Module Hand held module with upload/download capability to program, monitor and control drive.
CopyCat Keypad Module 160-P3
DeviceNet FAULT
READY
COMM
RS232 Serial Comm FAULT
READY
COMM
FAULT
DeviceNet Communication Module 160-DN2
RS-232 Serial Communication Module 160-RS1
Profibus Communication Module 160-PD1
READY
COMM
Profibus-DP
Interbus Communication Module 160-IB1
TR
FLT RD
InterBus
➅
20
160-P3
Cables ➁ Connects the 160Z to either the Remote or CopyCat Keypad Module. - 1 meter cable, locking each end - 3 meter cable, locking each end - 5 meter cable, locking each end
160Z-C10 160Z-C30 160Z-C50
Communication Modules and Accessories Allow control and monitoring of parameters via the networks listed below. These modules can be mounted inside the 160Z. - DeviceNet™ - RS-232 Serial Communication - Profibus - Interbus - RS232 Communication Terminal Block - Profibus Communication Terminal Block - Interbus In/Out Communication Terminal Block - Interbus Side Metal plate (5 holes)
160-DN2 ➂ 160-RS1 160-PD1 160-IB1 160Z-RTB 160Z-PTB 160Z-ITB 160Z-ISM
Motor Adapters - NEMA motor, 0.5 - 2 HP ➃ - NEMA motor, 3 - 5 HP ➃ - SEW, IEC Motor, 0.37-1.5 kW ➄ - SEW, IEC Motor, 2.2 kW ➄ - SEW, IEC Motor, 3.7 kW ➄➅
160Z-ABN1 160Z-ABN2 160Z-SEW1 160Z-SEW2 160Z-SEW3
Hardware - Power cable glands - Motor cable glands, wall mounting only - Communication and I/O cable glands
160Z-G25 160Z-G20 160Z-G16
Accessories - Debris cover, motor mount - Debris cover, wall mount - Fan replacement kit - Spare gasket kit (includes all gaskets) - Wall mounting kit (includes one 160Z-G20) - Wall mount adapter
160Z-DC 160Z-DCW 160Z-FRK 160Z-GSK 160Z-WMK 160Z-WMA
DriveExplorer™ Software Windows based software package that provides an intuitive means for monitoring or configuring Allen-Bradley drives and communication adapters. CC BA
Catalog No.
Remote Keypad Module 160-P2 Module for remote mounting. Has program, monitor and operator interface capability.
➀ ➁ ➂ ➃ ➄
See Publication 9306PL001A-EN-P.
160-P1 is not compatible with 160Z drives. 160-RPA is not required with 160Z drives. 160-RPA circuitry is included as standard. Includes 10 pin DeviceNet Connector. For mounting with Allen-Bradley 1329RS motors, cast iron, severe duty. For mounting with SEW, D-Type IEC motors. Maximum continuous output is 3.0 kW at 40°C and 4 kHz, 3.7 kW at 35°C and 2 kHz.