The text of a manual · part 1 of 14
160 SSC Variable Speed Drive (Series C) User Manual, pages 1 to 3
Pages 1 to 3 of 88: Front Cover; Important User Information; Series C Summary of Changes
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 160-BMB2 and Allen-Bradley 160-DM-PS1
Page 1
160 SSC™ Variable Speed Drive (Series C) 0.37–4.0 kW (0.5–5 HP) FRN 7.03 FRN 7.04 FRN 7.05 FRN 7.06
User Manual
Page 2
Important User Information Solid-State equipment has operational characteristics differing from those of electromechanical equipment. “Safety Guidelines for the Application, Installation and Maintenance of Solid-State Controls” (Publication SGI-1.1) describes some important differences between solid-state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid-state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation is prohibited. Throughout this manual we use notes to make you aware of safety considerations: ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage or economic loss. Attention statements help you to: • identify a hazard • avoid a hazard • recognize the consequences Important:
Identifies information that is especially important for successful application and understanding of the product.
Shock Hazard labels located on or inside the drive indicate that dangerous voltage may be present. SSC is a trademark of Rockwell Automation, Inc.
Page 3
S-1
Series C Summary of Changes • New Horsepower Ratings 4 kW (5 HP), 230V and 460V ratings have been added to the Bulletin 160 family. • Increased Transient Protection Standard input voltage transient protection has been increased to 6 kV and contained in the drive itself. The optional MOV module is no longer required. • Improved Ground Fault Protection The Bulletin 160 detects phase-to-phase and phase-to-ground faults both at start-up and while running. • Reduced 2.2 kW (3 HP) Footprint 2.2 kW (3 HP), 230V and 460V width has been reduced by more than 45%. • One Piece, 1.5 kW (2 HP) 230V Single Phase Unit The external capacitor module has been integrated into the 1.5 kW (2 HP), 230V single phase unit. The overall width of the unit is reduced, however, the height, depth, and mounting hole pattern has changed. • Improved Start/Stop Overlap Timing The STOP command can be removed up to 20 msec after a START command and the drive will still recognize the START command. This allows the drive to respond to a START command occurring concurrently with or slightly after a STOP command is removed. • Additional Fault History P17, P18, and P19 - [Fault Buffer 0, 1 and 2] have been added to record the last three faults for diagnostic purposes. • Analog Model with Preset Speed Capability Analog Signal Follower models have an additional input mode. With P46 - [Input Mode] setting 8, four preset speeds are available. • External Frequency Selection P46 - [Input Mode] has an additional setting (setting 7) which allows for the frequency source to be switched from the control terminal block (TB3) to the P58 - [Internal Frequency] setting.
• New Output Configuration Setting P47 - [Output Configure] has a new setting. When setting 10 is selected, the output will be active when the Power Factor Angle is above the P48 - [Output Threshold] setting. • Additional Compensation Mode P78 - [Compensation] has an additional mode that corrects for slow responding systems which can cause current regulator oscillations. • Software Current Trip P79 - [Software Current Trip] provides an adjustable software current trip with a one second time delay. • Adjustable Stall Fault Time The time that the drive must be in a stall condition before causing a stall fault is selectable via P80 - [Stall Fault Time]. • PI Control Process control is now intergrated in the drive through a PI regulator. Users of Firmware Version FRN 7.05 and earlier activate this feature with P46 - [Input Mode] setting 9. Users of Firmware Version FRN 7.06 can activate this feature with P46 [Input Mode] settings 0 through 7 and 9. PI control is adjusted through parameters P81 - [PI Proportional Gain], P82 - [PI Integrated Gain], P83 - [PI Process Reference], and P84 - [PI Dead Band]. • Fault Auto Clear Over voltage, Under voltage, and Over temperature faults are automatically cleared when the fault condition is removed. • RS-232 Serial Communication An RS-232 serial communication module using a DF1 protocol is now available. See 160-RS1 User Manual for additional information. • Ground Screw Location Grounding screws are now located on the power connection terminal blocks for easier wiring.