Page 1 of 160 SSC Variable Speed Drive (Series C) User Manual

Manual · Allen-Bradley

160 SSC Variable Speed Drive (Series C) User Manual

Manual88 pagesPDF 2.1 MB

User manual for the Allen-Bradley Bulletin 160 SSC Series C variable speed drive, 0.37 to 4.0 kW, with its option modules and accessories.

Download the PDF2.1 MB

Filed with · 2 models

Also filed with these models on the old site

Summary

What is in it

The user manual for the Bulletin 160 SSC Series C variable speed drive, 0.37 to 4.0 kW (0.5 to 5 HP), firmware FRN 7.03 to 7.06. It covers receiving and identifying the drive, installation, power and control wiring, the Program Keypad Module, start-up, parameters and programming including PI control, and fault troubleshooting. Appendices give specifications, accessories and dimensions (including 160-BMB catalog numbers and the 160-DM-PS1 24V DC interface) and CE conformity.

Its parts

  1. Getting Started
  2. Installation and Wiring
  3. Program Keypad Module
  4. Start-Up
  5. Parameters and Programming
  6. Troubleshooting

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

User manual for the Allen-Bradley Bulletin 160 SSC Variable Speed Drive, Series C, rated 0.37 to 4.0 kW (0.5 to 5 HP) with firmware FRN 7.03 to 7.06, in Analog Signal Follower and Preset Speed models. It walks through mounting, power and control wiring, the Program Keypad Module, start-up, every parameter, PI process control, fault codes, accessories and dimensions. The 160-BMB2 dynamic brake module and the 160-DM-PS1 24V DC interface module appear in it only as accessories in the Appendix B tables.

Drive type
Bulletin 160 SSC variable speed AC drive, Series C, 0.37 to 4.0 kW (0.5 to 5 HP), firmware FRN 7.03 to 7.06 p. 1
Input power
200/240VAC 1-phase or 3-phase (operating range 180-265VAC), or 380/460VAC 3-phase (340-506VAC), 50/60 Hz p. 63
Models
Analog Signal Follower (catalog code SF1) or Preset Speed (PS1) with 8 preset speeds p. 8
Dynamic brake modules
380-460V drives: 160-BMB1 for 0.75 kW, 160-BMB2 for 1.5 and 2.2 kW, two 160-BMB2 in parallel for 4.0 kW; 230V drives use 160-BMA1 or 160-BMA2; none for 0.37 or 0.55 kW p. 11, 67
24V DC interface
160-DM-SF1 (Analog model) or 160-DM-PS1 (Preset model) for 24VDC sinking inputs; Series C drives need a Series B or later module p. 4, 67
Control inputs
Dry contact or open collector inputs on terminal block TB3, powered by an internal 12V supply; two-wire or three-wire control p. 64
Speed reference
0 to 10V or -10 to +10V DC (100k ohm), 4-20 mA (250 ohm), or a 10k ohm 2 W potentiometer (Analog Signal Follower model) p. 31
Relay output
Form C relay on TB3-9/10/11; resistive 0.4A at 125V AC or 2A at 30V DC, set with P47 p. 30
Output
0 to 240 Hz, voltage adjustable up to input voltage; carrier 2 to 8 kHz (default 4 kHz) p. 64, 65
Keypads
Program Keypad Module 160-P1, Remote Keypad Module 160-P2, CopyCat Keypad Module 160-P3, Remote Programming Adapter 160-RPA, Ready/Fault Panel 160-B1; cables 160-C10, 160-C10R, 160-C30, 160-C50 p. 67
Communication modules
DeviceNet 160-DN2 (160-DN1 with FRN 2.0 or earlier does not work with Series C); RS-232 160-RS1 using DF1 p. 3, 4, 67
Dimensions and weight
152 x 80 x 165 mm (H x W x D), 0.94 to 1.10 kg for most ratings; 193 x 92 x 193 mm, 2.37 kg for 160S-AA08, 160-AA18 and 160-BA10 p. 72, 73
Temperature
Operating 0°C to 50°C; storage -40°C to 85°C; 0 to 95% humidity, non-condensing p. 64
Power terminals
TB1 and TB2, M4 screws, 12 to 18 AWG (10 to 12 AWG on 4.0 kW), 0.90 to 1.35 Nm p. 15

What this manual walks you through

  • Replacing a Series A or B drive with a Series C drive p. 4
  • Mounting the drive and leaving clearances p. 13
  • Power wiring, fuses and breakers, and motor cable lengths p. 14, 15, 17, 18, 19, 20
  • Wiring the control terminals for each input mode (P46 settings 0 to 9) p. 21, 22, 23, 24, 25, 26, 27, 28
  • Wiring the speed reference: analog signal, potentiometer or preset speeds p. 30, 31, 32
  • Using, removing and installing the Program Keypad Module p. 33, 34, 35, 36
  • First start-up and checking motor direction p. 37, 38
  • Setting parameters, including PI process control setup and tuning p. 39, 40, 43, 55, 56, 57
  • Fault codes, clearing faults and common problems p. 59, 60, 61
  • Installing for CE and EMC conformity p. 77, 78, 79, 80

Good to know

  • After removing power, wait three minutes for the capacitors to discharge before working on the drive. p. 7
  • Keep control wiring to 15 meters (50 feet) or less; for longer runs the manual recommends the 24V DC interface module. p. 21, 22
  • Control inputs use the internal 12V supply; applying an external voltage can damage the drive. p. 21
  • If input power is switched to start and stop the motor, do it no more than once a minute. p. 14
  • The 160 Dynamic Brake Module is rated for a 5% duty cycle. p. 49

Questions this manual answers

Which dynamic brake module fits a 460V 160 SSC drive?

160-BMB1 for 0.75 kW, 160-BMB2 for 1.5 and 2.2 kW, and two 160-BMB2 modules in parallel for 4.0 kW. The 0.37 and 0.55 kW units have no brake option. p. 11, 67

Why does the motor run backwards after replacing a 160 Series A or B drive with Series C?

Series C output phasing differs, so the same U, V, W wiring reverses rotation. Swap any two of the three motor leads. p. 4

How do I clear a fault on a Bulletin 160 drive?

After fixing the cause, press the keypad Stop button, remove power for one minute, cycle the TB3-8 input, or set P54 to 1. p. 59

What does fault F48 mean on a 160 SSC?

F48 is the Reprogram Fault, which occurs when parameters are reset to factory defaults; clear it with the Stop button or by cycling TB3-8. p. 40, 60

How do I reset a 160 SSC drive to factory defaults?

Set P56 [Reset Functions] to 1. An F48 fault follows and is cleared by cycling the Stop input; the input mode returns to 3-wire control. p. 50

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Front Cover1
  2. Important User Information2
  3. Series C Summary of Changes3
  4. Series C Application/Installation Considerations4
    1. Mounting Dimensions4
    2. External Braking4
    3. DeviceNet4
    4. 24V DC Interface4
    5. Terminal Block Wiring4
    6. Incorrect Motor Rotation4
  5. Chapter 17
    1. Important Precautions7
    2. Receiving Your New Drive8
    3. Identifying Your Drive8
    4. Standard Drive Features10
    5. Optional Drive Features11
  6. Chapter 213
    1. Storage and Operation Conditions13
    2. CE Compliance13
    3. Installation13
    4. Power Wiring14
    5. Control Wiring21
    6. Configurable Relay Output Contacts (P47 Settings)30
    7. Frequency Source Wiring30
    8. What To Do Next32
  7. Chapter 333
    1. Features33
    2. Key Functions34
    3. Module Removal and Installation35
  8. Chapter 437
    1. Start-Up Procedures37
  9. Chapter 539
    1. Overview of Parameters39
    2. Important Reset Actions40
    3. Programming Example40
    4. Display Group Parameters (Read Only)41
    5. Program Group Parameters43
    6. PI Control Setup and Activation55
  10. Chapter 659
13 more lines, from page 59 on
  1. Fault Information59
    1. How to Clear a Fault59
  2. Appendix A63
  3. Appendix B67
    1. Accessory Dimensions68
    2. Drive Dimensions72
  4. Appendix C77
    1. CE Compliance77
    2. Essential Requirements for a Conforming EMC Installation77
    3. General Instructions for an EMC Compliant Installation78
    4. Low Voltage Directive 73/23/EEC Compliance81
  5. Index83
  6. Back Cover88

From the PDF’s own bookmarks.

The whole text · 14 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 31-3
  2. Pages 4 to 64-6
  3. Chapter 17-12
  4. Chapter 2, pages 13 to 2213-22
  5. Chapter 2, pages 23 to 3223-32
  6. Chapter 333-36
  7. Pages 37 to 4437-44
  8. Pages 45 to 5245-52
  9. Pages 53 to 5853-58
  10. Chapter 659-62
  11. Appendix A63-66
  12. Appendix B67-76
  13. Appendix C77-82
  14. Pages 83 to 8883-88

The file

Revision and size

RevisionPublication 0160-5.17ML-EN, May 2000