Manual · Allen-Bradley
160 SSC Variable Speed Drive (Series C) User Manual
Manual88 pagesPDF 2.1 MB
User manual for the Allen-Bradley Bulletin 160 SSC Series C variable speed drive, 0.37 to 4.0 kW, with its option modules and accessories.
Filed with · 2 models
Also filed with these models on the old site
Summary
What is in it
The user manual for the Bulletin 160 SSC Series C variable speed drive, 0.37 to 4.0 kW (0.5 to 5 HP), firmware FRN 7.03 to 7.06. It covers receiving and identifying the drive, installation, power and control wiring, the Program Keypad Module, start-up, parameters and programming including PI control, and fault troubleshooting. Appendices give specifications, accessories and dimensions (including 160-BMB catalog numbers and the 160-DM-PS1 24V DC interface) and CE conformity.
Its parts
- Getting Started
- Installation and Wiring
- Program Keypad Module
- Start-Up
- Parameters and Programming
- Troubleshooting
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
User manual for the Allen-Bradley Bulletin 160 SSC Variable Speed Drive, Series C, rated 0.37 to 4.0 kW (0.5 to 5 HP) with firmware FRN 7.03 to 7.06, in Analog Signal Follower and Preset Speed models. It walks through mounting, power and control wiring, the Program Keypad Module, start-up, every parameter, PI process control, fault codes, accessories and dimensions. The 160-BMB2 dynamic brake module and the 160-DM-PS1 24V DC interface module appear in it only as accessories in the Appendix B tables.
- Drive type
- Bulletin 160 SSC variable speed AC drive, Series C, 0.37 to 4.0 kW (0.5 to 5 HP), firmware FRN 7.03 to 7.06 p. 1
- Input power
- 200/240VAC 1-phase or 3-phase (operating range 180-265VAC), or 380/460VAC 3-phase (340-506VAC), 50/60 Hz p. 63
- Models
- Analog Signal Follower (catalog code SF1) or Preset Speed (PS1) with 8 preset speeds p. 8
- Dynamic brake modules
- 380-460V drives: 160-BMB1 for 0.75 kW, 160-BMB2 for 1.5 and 2.2 kW, two 160-BMB2 in parallel for 4.0 kW; 230V drives use 160-BMA1 or 160-BMA2; none for 0.37 or 0.55 kW p. 11, 67
- 24V DC interface
- 160-DM-SF1 (Analog model) or 160-DM-PS1 (Preset model) for 24VDC sinking inputs; Series C drives need a Series B or later module p. 4, 67
- Control inputs
- Dry contact or open collector inputs on terminal block TB3, powered by an internal 12V supply; two-wire or three-wire control p. 64
- Speed reference
- 0 to 10V or -10 to +10V DC (100k ohm), 4-20 mA (250 ohm), or a 10k ohm 2 W potentiometer (Analog Signal Follower model) p. 31
- Relay output
- Form C relay on TB3-9/10/11; resistive 0.4A at 125V AC or 2A at 30V DC, set with P47 p. 30
- Output
- 0 to 240 Hz, voltage adjustable up to input voltage; carrier 2 to 8 kHz (default 4 kHz) p. 64, 65
- Keypads
- Program Keypad Module 160-P1, Remote Keypad Module 160-P2, CopyCat Keypad Module 160-P3, Remote Programming Adapter 160-RPA, Ready/Fault Panel 160-B1; cables 160-C10, 160-C10R, 160-C30, 160-C50 p. 67
- Communication modules
- DeviceNet 160-DN2 (160-DN1 with FRN 2.0 or earlier does not work with Series C); RS-232 160-RS1 using DF1 p. 3, 4, 67
- Dimensions and weight
- 152 x 80 x 165 mm (H x W x D), 0.94 to 1.10 kg for most ratings; 193 x 92 x 193 mm, 2.37 kg for 160S-AA08, 160-AA18 and 160-BA10 p. 72, 73
- Temperature
- Operating 0°C to 50°C; storage -40°C to 85°C; 0 to 95% humidity, non-condensing p. 64
- Power terminals
- TB1 and TB2, M4 screws, 12 to 18 AWG (10 to 12 AWG on 4.0 kW), 0.90 to 1.35 Nm p. 15
What this manual walks you through
- Replacing a Series A or B drive with a Series C drive p. 4
- Mounting the drive and leaving clearances p. 13
- Power wiring, fuses and breakers, and motor cable lengths p. 14, 15, 17, 18, 19, 20
- Wiring the control terminals for each input mode (P46 settings 0 to 9) p. 21, 22, 23, 24, 25, 26, 27, 28
- Wiring the speed reference: analog signal, potentiometer or preset speeds p. 30, 31, 32
- Using, removing and installing the Program Keypad Module p. 33, 34, 35, 36
- First start-up and checking motor direction p. 37, 38
- Setting parameters, including PI process control setup and tuning p. 39, 40, 43, 55, 56, 57
- Fault codes, clearing faults and common problems p. 59, 60, 61
- Installing for CE and EMC conformity p. 77, 78, 79, 80
Good to know
- After removing power, wait three minutes for the capacitors to discharge before working on the drive. p. 7
- Keep control wiring to 15 meters (50 feet) or less; for longer runs the manual recommends the 24V DC interface module. p. 21, 22
- Control inputs use the internal 12V supply; applying an external voltage can damage the drive. p. 21
- If input power is switched to start and stop the motor, do it no more than once a minute. p. 14
- The 160 Dynamic Brake Module is rated for a 5% duty cycle. p. 49
Questions this manual answers
Which dynamic brake module fits a 460V 160 SSC drive?
160-BMB1 for 0.75 kW, 160-BMB2 for 1.5 and 2.2 kW, and two 160-BMB2 modules in parallel for 4.0 kW. The 0.37 and 0.55 kW units have no brake option. p. 11, 67
Why does the motor run backwards after replacing a 160 Series A or B drive with Series C?
Series C output phasing differs, so the same U, V, W wiring reverses rotation. Swap any two of the three motor leads. p. 4
How do I clear a fault on a Bulletin 160 drive?
After fixing the cause, press the keypad Stop button, remove power for one minute, cycle the TB3-8 input, or set P54 to 1. p. 59
What does fault F48 mean on a 160 SSC?
F48 is the Reprogram Fault, which occurs when parameters are reset to factory defaults; clear it with the Stop button or by cycling TB3-8. p. 40, 60
How do I reset a 160 SSC drive to factory defaults?
Set P56 [Reset Functions] to 1. An F48 fault follows and is cleared by cycling the Stop input; the input mode returns to 3-wire control. p. 50
Contents
Chapters and sections
Each line opens the PDF at its page.
- Front Cover1
- Important User Information2
- Series C Summary of Changes3
- Series C Application/Installation Considerations4
- Chapter 17
- Chapter 213
- Chapter 333
- Chapter 437
- Chapter 539
- Chapter 659
13 more lines, from page 59 on