Page 7

Chapter 1

Getting Started Important Precautions In addition to the precautions listed throughout this manual, you must read and understand the following statements which identify hazards associated with AC drives. ATTENTION: The drive contains high voltage capacitors which take time to discharge after removal of mains supply. Before working on drive, ensure isolation of mains supply from line inputs [R, S, T (L1, L2, L3)]. Wait three minutes for capacitors to discharge to safe voltage levels. Failure to do so may result in personal injury or death. Darkened display LEDs is not an indication that capacitors have discharged to safe voltage levels. ATTENTION: Only personnel familiar with the drive and associated machinery should plan or implement the installation, start-up, and subsequent maintenance of the system. Failure to comply may result in personal injury and/or equipment damage. ATTENTION: The surface temperatures of the drive may become hot, which may cause injury.

ATTENTION: This drive contains ESD (Electrostatic Discharge) sensitive parts and assemblies. Static control precautions are required when installing, testing, servicing or repairing this assembly. Component damage may result if ESD control procedures are not followed. If you are not familiar with static control procedures, reference Publication 8000-4.5.2, “Guarding Against Electrostatic Damage” or any other applicable ESD protection handbook. ATTENTION: An incorrectly applied or installed drive can result in component damage or reduction in product life. Wiring or application errors such as undersizing the motor, supplying an incorrect or an inadequate AC supply, or excessive ambient temperatures may result in system malfunction.

Page 8

1-2

Getting Started

Receiving Your New Drive It is your responsibility to thoroughly inspect the equipment before accepting the shipment from the freight company. Check the item(s) received against your purchase order. If any items are obviously damaged, do not accept delivery until the freight agent notes the damage on the freight bill.

Unpacking Remove all packing material, wedges, or braces from within and around the drive. Remove all packing material from the heat sink. Leave the debris label in place. If you find any concealed damage during unpacking notify the freight agent. Also, leave the shipping container intact and have the freight agent make a visual inspection of the equipment to verify damage.

Inspecting After unpacking, check the item(s) nameplate catalog number against your purchase order. An explanation of the catalog numbering system for the Bulletin 160 drive follows as an aid for nameplate interpretation. Refer to Figure 1.1 and Figure 1.2. Important:

Before you install and start up the drive, inspect for mechanical integrity. Look for loose parts, wires, and connections.

Identifying Your Drive Catalog Number The figure below describes the 160 SSC catalog numbering scheme. Catalog Number Explanation

Figure 1.1

160 - A A02

N SF1

First Position

Second Position

Third Position

Bulletin Number

Voltage Rating

Current Rating➊ Enclosure Type

An “S” in the Bulletin A 200-240V, 1-Phase 200-240V, 3-Phase Number denotes a single-phase input B 380-460V, 3-Phase voltage.

A01 A02 A03 A04 A06 A08 A10 A12 A18

Fourth Position

P1

Fifth Position

Sixth Position

Model

Programmer (Optional)

SF1 Analog Signal N Open (IP20) Follower L Low Profile PS1 Preset Speed P Chassis Mount (external heatsink) R Chassis Mount Replacement

B1 Ready/Fault Indicating Panel P1 Program Keypad Module

➊ Amperage ratings vary based on voltage. Note: Rockwell Automation offers a configured drive program which allows for NEMA rated 4, 4x, or 12 enclosures.

Page 9

Getting Started

1-3

Nameplate The nameplate is located on the side of the drive. Nameplate Information

Figure 1.2 Catalog Number

160-AA02NSF1P1 ANALOG S.F.

Motor Rating:

I N P U T

SERIES C FRN: 7.XX

Series Letter Firmware Version Drive Model

0.37KW / 0.5 HP

V: 200-240 A: 2.8 Hz: 50/60 VA: 1100

3 Ø O V: 200-230 U T A: 2.3 P Hz: 0-240 U T

3Ø

S/N: XXXXXXXX XXXXX

Serial Number Date Code

OPERATING AMBIENT TEMP: 0 - 50° C SHORT CIRCUIT CURRENT: 100 KA POWER TERMINAL WIRE : Use 75° C Cu Wire: 4 mm2 - .75 mm2 (12-18 AWG.) Torque 1.35 Nm (12 in.- lbs.)

IP20 Allen-Bradley

C

UL US

LISTED IND. CONT. EQ. 966X

Enclosure Rating

MADE IN U.S.A.

Conventions Used In This Manual Parameter numbers and names are shown in this format: P01 - [Output Frequency]. P01 denotes the parameter number and the parameter name is enclosed in square brackets.

Page 10

1-4

Getting Started

Standard Drive Features The drive features identified in the figure below apply to all models. Standard Drive Features and Mounting Orientation

Figure 1.3

Hinged Finger Guard R/L1 S/L2 T/L3 BR– BR+

FAULT

Ready/Fault Indicating Panel

READY

Status LEDs

1 2 3 4 5 6 7 8 9 10 11

DC Bus Test Points U/T1 V/T2 W/T3 DC– DC+

Hinged Finger Guard Cooling Fan Cooling Air Flow

DIN Latch

• Hinged Finger Guard allows easy access to line/load power terminals. • Ready/Fault Indicating Panel is standard on the Bulletin 160 drive. The drive is fully functional with this panel installed. All control functions can be performed from TB3 (Control Terminal Block). Factory default settings cannot be changed with this panel. • Fault Indicator LED illuminates when a drive fault condition exists. Refer to Chapter 6 for details on how to clear a fault and general troubleshooting procedures. • Ready Indicator LED illuminates when the DC bus is charged and the drive is ready to run. • DC Bus Test Points provide easy access for test probes when measuring DC Bus voltage. • Cooling Fan provides air flow across heatsink fins to prevent overheating. Not required on .37 or .55 kW (.5 or .75 HP) ratings. • DIN Latch provides an easy means for mounting the drive on standard 35 mm DIN Rail. This feature is not available with 4.0 kW (5 HP) or 1.5 kW (2 HP) single phase units.

Page 11

Getting Started

1-5

Optional Drive Features The drive features identified in the figure below are optional. See Appendix B for catalog numbers. (Finger guards omitted for clarity.) Optional Drive Features

Figure 1.4 Dynamic Brake Module

R/L1 S/L2 T/L3 BR– BR+

1 2 3 4 5 6 7 8 9 10 11

Line Filter Module Program Keypad Module or DeviceNet Communication Module or RS-232 Communication Module or Remote Programming Adapter to: Remote Keypad Module or CopyCat Keypad Module

U/T1 V/T2 W/T3 DC– DC+

24V DC Interface Module Capacitor Module • Dynamic Brake Module option allows you to connect dynamic brake resistors. Not available on .37 or .55 kW (.5 or .75 HP) ratings. Important: P52 - [DB Enable] must be enabled for proper operation. • Line Filter Module option is available to reduce conductive emissions. • Program Keypad Module option can be ordered separately and field installed, or as a factory installed option by adding “P1” to the end of the catalog number. Refer to Chapter 3, Program Keypad Module for a detailed explanation of functionality. • DeviceNet Communication Module option allows control and monitoring of parameters via a DeviceNet network. • RS-232 Communication Module option allows control and monitoring of parameters via a RS-232 network. • Remote Programming Adapter option allows connection to Remote Keypad Module or Copycat Keypad Module via cable (1 to 3 meters). • 24V DC Interface Module option allows you to command the drive with 24V logic (sinking inputs). • Capacitor Module option allows you to connect an external capacitor module. Provides extended ride through capability and improved inherent braking performance.

Page 12

1-6

Getting Started