Page 83
Index Symbols
±10V DC control 2-19 clearing faults 5-12, 6-1 compensation 5-15 compliance CE A-2, C-1 CSA A-2 CUL A-2 EEC C-5 conditioning input power 2-6 control wiring 2-9–2-17 precautions 2-9 preset speed 2-20 requirements 2-9 CSA A-2 CUL A-2 current limiting 5-8
Numerics
12V internal power supply 2-9 24V DC interface module B-5 4 – 20 mA control 2-19
A
B
C
AC input wiring 2-3 Accel/Decel control 5-5, 5-13 accessories (see optional accessories) B-1 ambient temperature 2-1, A-2 analog input frequency sources 2-18 analog inversion inverting input 5-15 analog scaling analog input min/max 5-15 analog select 5-14 zero offset 5-12 analog signal 2-18 approvals CE A-2, C-1 CSA A-2 CUL A-2 arrow keys 3-2 auto restart 5-10
D block diagram 6-4 braking DC injection 5-8 enabling dynamic braking 5-11 stop mode 5-6 branch circuit disconnect 2-3 branch circuit protection 2-5 capacitive current cable length recommendations 2-8 capacitor module B-1, B-4 connection 1-5 carrier frequency A-3 PWM 5-10 catalog number explanation 1-2 location 1-3 CE 2-1, A-2, C-1 change direction (see also analog inversion) 3-2 circuit breaker ratings 2-5
E
F
DeviceNet module 1-5, B-5 diagnostics display group parameters 5-3–5-5 fault descriptions 6-2 dimensions 24V DC interface module B-5 capacitor module B-4 DeviceNet module B-5 drive B-6, B-7 dynamic brake module B-2 line filter module B-3 line reactor B-2 mounting B-8 direction indicators 3-2 display mode 3-1 dynamic brake module B-1, B-2 connection 1-5 dynamic braking 5-11 electrostatic discharge 1-1, 3-3 enter key 3-2 escape key 3-2 fan replacement B-1 faults clearing 5-12, 6-1 descriptions 6-2 problems and corrective actions 6-3 status LEDs 1-4
Page 84
Index-2 features optional 1-5 standard 1-4 frequency control min/max frequency 5-6 skip frequency 5-7 frequency source 2-18 fuse ratings 2-5
G I
K
L
M
N
O grounding 2-3, 2-9 input mode selection 2-11, 5-9 input power conditioning 2-6 protection 2-5 installation clearances 2-1 EMC compliance C-1–C-4 templates B-9, B-10 internal 12V power supply 2-9 keypad display mode 3-1 installation 3-4 key descriptions 3-2 program mode 3-1 removal 3-3 LEDs 1-4, 3-2 line filter module 1-5, B-1, B-3 line reactor B-1, B-2 line side protection 2-5 lock protection 5-12 motor cable length recommendations 2-7–2-8 long cable effects 2-7 recommended cable 2-6 reflective wave 2-7 motor starter 2-5 mounting requirements clearances 2-1 mounting templates B-9, B-10 nameplate information 1-3
P optional accessories 24V DC interface module 1-5, B-5 capacitor module 1-5, B-4 DeviceNet module 1-5, B-5 dynamic brake module 1-5, B-2 line filters 1-5, B-1, B-3 line reactors B-1, B-2 program keypad module 1-5 output contacts 2-9, 5-10 overload protection 2-5, 5-8 parameters 5-1–5-16 commonly changed 5-1 display group 5-3–5-5 01 - [Output Frequency] 5-3 02 - [Output Voltage] 5-3 03 - [Output Current] 5-3 04 - [Output Power] 5-3 05 - [Bus Voltage] 5-3 06 - [Frequency Command] 5-3 07 - [Last Fault] 5-3 08 - [Heatsink Temperature] 5-3 09 - [Controller Status] 5-3 10 - [Controller Type] 5-3 11 - [Control Version] 5-3 12 - [Input Status] 5-4 13 - [Power Factor Angle] 5-4 14 - [Memory Probe Display] 5-4 15 - [Preset Status] 5-4 16 - [Analog Input] 5-4 17 - [Fault Buffer 0] 5-5 18 - [Fault Buffer 1] 5-5 19 - [Fault Buffer 2] 5-5 overview 5-1 program group 5-5–5-16 30 - [Accel Time 1] 5-5 31 - [Decel Time 1] 5-6 32 - [Maximum Frequency] 5-6 32 - [Minimum Frequency] 5-6 34 - [Stop Mode Select] 5-6 35 - [Base Frequency] 5-6 36 - [Base Voltage] 5-6 37 - [Boost Select] 5-7 37 - [Maximum Voltage] 5-6 39 - [Skip Frequency] 5-7
Page 85
Index-3
40 - [Skip Frequency Band] 5-7 41 - [Motor Overload Select] 5-8 42 - [Motor Overload Current] 5-8 43 - [Current Limit] 5-8 44 - [DC Hold Time] 5-8 45 - [DC Hold Voltage] 5-9 46 - [Input Mode] 5-9 47 - [Output Configure] 5-10 48 - [Output Threshold] 5-10 49 - [PWM Frequency] 5-10 50 - [Restart Tries] 5-10 51 - [Restart Time] 5-11 52 - [DB Enable] 5-11 53 - [S-Curve] 5-11 54 - [Clear Fault] 5-12 55 - [Memory Probe Address] 5-12 56 - [Reset Functions] 5-12 57 - [Program Lock] 5-12 58 - [Internal Frequency] 5-12 59 - [Frequency Select] 5-12 60 - [Zero Offset] 5-12 61 – 68 - [Preset Frequency 0-7] 5-13 69 - [Accel Time 2] 5-13 70 - [Decel Time 2] 5-13 71 - [IR Compensation] 5-14 72 - [Slip Compensation] 5-14 73 - [Reverse Disable] 5-14 74 - [Analog Select] 5-14 75 - [Analog Input Minimum] 5-15 76 - [Analog Input Maximum] 5-15 78 - [Compensation] 5-15 79 - [Software Current Trip] 5-15 80 - [Stall Fault Time] 5-15 81 - [PI Proportional Gain] 5-16 82 - [PI Integral Gain] 5-16 83 - [PI Process Reference] 5-16 resetting to factory defaults 5-12 potentiometer wiring 2-19 power wiring 2-2 precautions 2-2 terminal block specifications 2-3 precautions 1-1 preset frequencies 5-12
Program Keypad Module 1-5 display mode 3-1 installation 3-4 key descriptions 3-2 program mode 3-1 removal 3-3 program lock 5-12 program mode 3-1 programming 5-1 example 5-2 reset to defaults 5-2
R
S
T
V reflected wave protection 2-7 reflective wave cable length 2-7 RWR (reflective wave reducer) 2-7 resetting default values 5-12 reverse key 3-2 RS-232 module B-5 S-Curve 5-11 select key 3-2 specifications A-1–A-3 380-460V AC input ratings A-1 control 2-9 electrical 2-2 environment 2-1 input power protection 2-5 installation 2-1 wiring 2-3 start key 3-2 start-up 4-1 stop key 3-2 storage temperature 2-1, A-2 terminal block control wiring 2-9 specifications 2-9 TB1 2-2 TB2 2-2 TB3 2-2 troubleshooting 6-1 fault descriptions 6-2 problems and corrective actions 6-3 vibration A-2
Page 86
Index-4
W wiring analog input 2-18 cable length 2-7 control/signal 2-9–2-17 motor cable specifications 2-6 symbol key 2-10 terminal block specifications 2-3
Page 87
Page 88
Publication 0160-5.17ML-EN, May 2000 Supersedes 0160-5.15 – January 1999, 0160-5.15DU3 – June 1999, 0160-5.15DU4 – November 1999
P/N 194456 (02) Copyright 2000 Rockwell International Corporation. All rights reserved. Printed in USA.