The text of a manual · part 60 of 70
SLC 500 Instruction Set Reference Manual, pages 591 to 600
Pages 591 to 600 of 694
The original document is the PDF (7.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 1747-L514
Page 591
Memory Usage
C-11
SLC 5/02 Memory Usage Example
1747-L524 series C processor, 30-slot configuration, (15) 1746-IA16, (10) 1746-OA8, (1) 1747-DCM full configuration, (1) 1746-NI4, (1) 1746-NIO4I 50
XIC and XIO
50 x 1.00
=
50.00
15
OTE instructions
15 x 0.75
=
11.25
5
TON instructions
5 x 1.00
=
5.00
3
GRT instructions
3 x 1.50
=
4.50
1
SCL instruction
1 x 1.75
=
1.75
1
TOD instruction
1 x 1.00
=
1.00
3
MOV instructions
3 x 1.50
=
4.50
10
CTU instructions
10 x 1.00
=
10.00
10
RES instructions
10 x 1.00
=
10.00
Instruction Usage
98.00
30 rungs
30 x 0.375
=
11.25
100 data words
100 x 0.250
=
25.00
10 is highest data table file number
10 x 1.00
=
10.00
4 is highest program file number
4 x 2.00
=
8.00
User Program Total
163.50
49
I/O data words
49 x 0.75
=
36.75
30 slot
30 x 0.75
=
22.50
Overhead
204.00
I/O Configuration Total
263.25
Estimated total memory usage:
426.75 (round to 427)
4096 - 290 = 3806 instruction words remaining in the processor
Publication 1747-RM001G-EN-P - November 2008
Page 592
C-12
Memory Usage
User Word Comparison Between SLC 5/03 (and higher) Processors and the SLC 5/02 Processor
The SLC 5/03 (and higher) processors and the SLC 5/02 processor accumulate user words differently during the creation of a user program. The SLC 5/02 processor is generally more efficient in its word usage than the SLC 5/03 (and higher) processors. However, the SLC 5/02 processor word usage is difficult to estimate since it is tied to the architecture of the microprocessor. The SLC 5/03 (and higher) processors accumulates words in a way that is easier to understand and estimate than the SLC 5/02 processor. The SLC 5/03 (and higher) processors accumulate words similar to a PLC-5. See page C-1 for user memory capacities for the various SLC processors. It is important to realize that this does not mean that a 16k, SLC 5/03 processor can hold a user program that is three times larger than an equivalent SLC 5/02 program. Use the information below to determine the SLC 5/03 user program size based on existing SLC 5/02 programs.
Instruction Words Some instructions use the same amount of memory, while other instructions do not use the same amount of memory. For example, a CTU instruction always uses 1 word. However, an ADD instruction in an SLC 5/02 processor uses 1.5 words; in a SLC 5/03 (or higher) processor an ADD instruction uses 3 words. Also note additional differences below:
Table C.4 Memory Usage Condition
SLC 5/02 Words
SLC 5/03 Words
SLC 5/04 and SLC 5/05 Words
Each rung
0.375
1
1
Each additional Program File 1
5
5
Each additional Data File
1
5
5
Each I/O Slot
0.75
3
3
Overhead
216
236
250
Exact program content determines the program size difference. An SLC 5/03 program consumes 20% to 150% more instruction words than its SLC 5/02 equivalent.
Publication 1747-RM001G-EN-P - November 2008
Page 593
Memory Usage
C-13
Data Words Files 0 and 1 In the SLC 5/02 processor, each I/O data word consumes 0.75 words of memory. In the SLC 5/03 processor, each I/O data word consumes 3 words of data.
File 2 The status file word usage is contained in the overhead values for both the SLC 5/02 and SLC 5/03 processors.
File 3 to 255 In the SLC 5/02 processor, 4 data words consume the same amount of memory as 1 instruction word. This is why the SLC 5/02 processor is said to offer 4K of Instruction words or 16K of Data words. This dynamic amount of Data word storage is due to the architecture of the SLC 5/02’s microprocessor.
The following table shows memory usage times for the SLC 5/03, SLC 5/04, and SLC 5/05 processors. Instructions that support floating point are included within this table. When using a SLC 5/03 processor, it is important to remember that 1 instruction word equals 1 data word.
SLC 5/03, SLC 5/04, and SLC 5/05 Processor
Table C.5 SLC 5/03, SLC 5/04 and SLC 5/05 List of Instructions
OS302, OS401, OS501 Series C, FRN 10+
Page
OS302, OS401, OS501 Series C
ABS
•
Instruction Type
OS302, OS401, OS501
OS300 ABS
Name
•
•
•
•
2.00
Test Buffer for Line
ASCII
10-6
•
•
•
•
2.00
Absolute
Math
4-24
•
•
•
2.00
Absolute
Math
4-24
FP = floating point
ABL
Memory Usage (user words)
OS301, OS400
Applies to SLC
Mnemonic
FP
ACB
•
•
•
•
2.00
Number of Characters in Buffer
ASCII
10-7
ACI
•
•
•
•
2.00
String to Integer
ASCII
10-8
Publication 1747-RM001G-EN-P - November 2008
Page 594
C-14
Memory Usage
Table C.5 SLC 5/03, SLC 5/04 and SLC 5/05 List of Instructions (Continued) Instruction Type
Page
OS302, OS401, OS501 Series C, FRN 10+
Name
OS302, OS401, OS501 Series C
Memory Usage (user words)
OS302, OS401, OS501
Applies to SLC
OS301, OS400
Mnemonic
ACL
•
•
•
•
2.00
ASCII Clear Receive and/or Send Buffer
ASCII
10-9
ACN
•
•
•
•
3.00
String Concatenate
ASCII
10-11
•
•
•
2.00
Arc Cosine
Math
4-29
•
•
•
3.00, 4.00
Add
Math
4-5
•
•
•
4.00
Add
Math
4-5
OS300
FP = floating point
ACS ADD ADD
•
•
FP
AEX
•
•
•
•
4.00
String Extract
ASCII
10-12
AHL
•
•
•
•
4.00
ASCII Handshake Lines
ASCII
10-13
AIC
•
•
•
•
2.00
Integer to String
ASCII
10-14
•
•
•
•
3.00
And
Data Handling
5-20
ARD
•
•
•
•
3.00
ASCII Read Characters
ASCII
10-15
ARL
•
•
•
•
3.00
ASCII Read Line
ASCII
10-17
ASC
•
•
•
•
4.00
String Search
ASCII
10-18
•
•
•
2.00
Arc Sine
Math
4-29
•
•
•
3.00
ASCII String Compare
ASCII
10-19
•
•
•
2.00
Arc Tangent
Math
4-30
AND
ASN
•
FP
ASR ATN
• FP
AWA
•
•
•
•
3.00
ASCII Write with Append
ASCII
10-20
AWT
•
•
•
•
3.00
ASCII Write
ASCII
10-22
BSL
•
•
•
•
•
3.00
Bit Shift Left
Application Specific
7-4
BSR
•
•
•
•
•
3.00
Bit Shift Right
Application Specific
7-4
BTR
•
•
5.00
Block Transfer Read
Block Transfer
8-1
BTW
•
•
5.00
Block Transfer Write
Block Transfer
8-1
•
73.00
ControlNet Explicit Message
Communication
12-45
CEM CLR CLR
• FP
COP COS
•
•
•
FP
CPT
•
•
•
3.00, 1.00
Clear
Math
4-12
•
•
•
1.00
Clear
Math
4-12
•
•
•
3.00
File Copy
Data Handling
5-13
•
•
•
2.00
Cosine
Math
4-30
•
•
•
(1)
Compute
Math
4-25
CTD
•
•
•
•
•
1.00
Count Down
Basic
2-14
CTU
•
•
•
•
•
1.00
Count Up
Basic
2-13
Publication 1747-RM001G-EN-P - November 2008
Page 595
Memory Usage
C-15
Table C.5 SLC 5/03, SLC 5/04 and SLC 5/05 List of Instructions (Continued)
OS302, OS401, OS501
OS302, OS401, OS501 Series C
OS302, OS401, OS501 Series C, FRN 10+
•
•
2.00
Decode 4 to 1 of 16
Data Handling
5-10
•
•
•
•
2.00
Double Divide
Math
4-11
•
•
6.00
Diagnostic Detect
Application Specific
7-18
•
•
2.00
Degree
Data Handling
5-8
•
74.00
DeviceNet Explicit Message
Communication
12-52
FP
•
DEM DIV
•
•
FP
•
•
•
3.00, 4.00
Divide
Math
4-9
•
•
•
4.00
Divide
Math
4-9
•
64.00
Ethernet/IP Explicit Message
Communication
12-58
•
•
2.00
Encode 1 of 16 to 4
Data Handling
5-11
EEM ENC EQU EQU
Page
•
DDT
DIV
Instruction Type
•
DDV DEG
Name
•
FP = floating point
DCD
Memory Usage (user words)
OS301, OS400
Applies to SLC
OS300
Mnemonic
• FP
•
•
•
•
3.00
Equal
Comparison
3-2
•
•
•
•
3.00
Equal
Comparison
3-2
•
•
6.00
File Bit Comparison
Application Specific
7-18
FBC FFL
•
•
•
•
•
3.00
FIFO Load
Data Handling
5-26
FFU
•
•
•
•
•
4.00
FIFO Unload
Data Handling
5-26
FLL
•
•
•
•
•
3.00
Fill File
Data Handling
5-13
FRD
•
•
•
•
•
2.00
Convert from BCD
Data Handling
5-5
GEQ
•
•
•
•
•
3.00
Greater Than or Equal
Comparison
3-4
•
•
•
•
3.00
Greater Than or Equal
Comparison
3-4
•
•
•
•
3.00
Greater Than
Comparison
3-3
•
•
•
•
3.00
Greater Than
Comparison
3-3
GEQ
FP
GRT GRT
• FP
IID
•
•
•
•
•
2.00
I/O Interrupt Disable
Interrupt
11-32
IIE
•
•
•
•
•
2.00
I/O Interrupt Enable
Interrupt
11-32
IIM
•
•
•
•
•
6.00
Immediate Input with Mask
Program Flow Control 6-8
INT
•
•
•
•
•
1.00
Interrupt Subroutine
Interrupt
IOM
•
•
•
•
•
6.00
Immediate Output with Mask
Program Flow Control 6-9
JMP
•
•
•
•
•
1.00
Jump to Label
Program Flow Control 6-2
JSR
•
•
•
•
•
1.00
Jump to Subroutine
Program Flow Control 6-3
LBL
•
•
•
•
•
2.00
Label
Program Flow Control 6-2
LEQ
•
•
•
•
•
3.00
Less Than or Equal
Comparison
11-34
3-3
Publication 1747-RM001G-EN-P - November 2008
Page 596
C-16
Memory Usage
Table C.5 SLC 5/03, SLC 5/04 and SLC 5/05 List of Instructions (Continued)
LES
• FP
Page
OS302, OS401, OS501 Series C, FRN 10+
LES
Instruction Type
OS302, OS401, OS501 Series C
OS300 FP
Name
•
•
•
•
3.00
Less Than or Equal
Comparison
3-3
•
•
•
•
3.00
Less Than
Comparison
3-3
•
•
•
•
3.00
Less Than
Comparison
3-3
FP = floating point
LEQ
Memory Usage (user words)
OS302, OS401, OS501
Applies to SLC
OS301, OS400
Mnemonic
LFL
•
•
•
•
•
3.00
LIFO Load
Data Handling
5-28
LFU
•
•
•
•
•
3.00
LIFO Unload
Data Handling
5-28
LIM
•
•
•
•
•
1.00
Limit Test
Comparison
3-5
•
•
•
•
1.00
Limit Test
Comparison
3-5
LIM
FP
LN
FP
•
•
•
2.00
Natural Log
Math
4-31
LOG
FP
•
•
•
2.00
Log to the Base 10
Math
4-31
MCR
•
•
•
•
•
1.00
Master Control Reset
Program Flow Control 6-6
MEQ
•
•
•
•
•
4.00
Masked Comparison for Equal
Comparison
3-4
MOV
•
•
•
•
•
2.00
Move
Data Handling
5-17
•
•
•
•
2.00
Move
Data Handling
5-17
MOV
FP
MSG
•
•
•
•
•
20.00
Message
Communication
12-5
MUL
•
•
•
•
•
3.00
Multiply
Math
4-8
•
•
•
3.00
Multiply
Math
4-8
MUL
FP
MVM
•
•
•
•
•
3.00, 4.00
Masked Move
Data Handling
5-18
NEG
•
•
•
•
•
3.00
Negate
Data Handling
5-24
•
•
•
3.00
Negate
Data Handling
5-24
•
•
•
•
3.00
Not Equal
Comparison
3-2
•
•
•
•
3.00
Not Equal
Comparison
3-2
NEG
FP
NEQ NEQ
• FP
NOT
•
•
•
•
•
3.00
Not
Data Handling
5-23
OR
•
•
•
•
•
3.00
Or
Data Handling
5-21
OTE
•
•
•
•
•
1.00
Output Energize
Basic
2-4
OTL
•
•
•
•
•
1.00
Output Latch
Basic
2-4
OTU
•
•
•
•
•
1.00
Output Unlatch
Basic
2-4
PID
•
•
•
•
•
26.00
Proportional Integral Derivative
PID
9-1
•
•
•
2.00
Radian
Data Handling
5-9
•
•
•
1.00
I/O Refresh
Program Flow Control 6-10
RAD REF
FP •
•
Publication 1747-RM001G-EN-P - November 2008
Page 597
Memory Usage
C-17
Table C.5 SLC 5/03, SLC 5/04 and SLC 5/05 List of Instructions (Continued) Page
2-20
OS302, OS401, OS501 Series C, FRN 10+
Instruction Type
OS302, OS401, OS501 Series C
Name
OS302, OS401, OS501
Memory Usage (user words)
OS301, OS400
Applies to SLC
OS300
Mnemonic
RES
•
•
•
•
•
1.00
Reset
Basic
RET
•
•
•
•
•
1.00
Return from Subroutine
Program Flow Control 6-3
RHC
•
•
2.00
Read High Speed Clock
Application Specific
7-17
RMP
•
•
2.00
Ramp
Math
4-20
•
3.00
Read Program Checksum
Application Specific
7-23
FP = floating point
RPC RPI
•
•
•
•
•
2.00
Reset Pending Interrupt
Interrupt
11-34
RTO
•
•
•
•
•
1.00
Retentive Timer
Basic
2-11
SBR
•
•
•
•
•
1.00
Subroutine
Program Flow Control 6-3
•
•
•
4.00
Scale Data
Math
4-15
•
•
•
6.00
Scale with Parameters
Math
4-13
SCL
FP
SCP SCP
FP
•
•
•
6.00
Scale with Parameters
Math
4-13
SIN
FP
•
•
•
2.00
Sine
Math
4-32
SQC
•
•
•
•
•
5.00
Sequencer Compare
Application Specific
7-6
SQL
•
•
•
•
•
4.00
Sequencer Load
Application Specific
7-12
SQO
•
•
•
•
•
5.00
Sequencer Output
Application Specific
7-6
SQR
•
•
•
•
•
2.00, 3.00
Square Root
Math
4-12
•
•
•
3.00
Square Root
Math
4-12
SQR
FP
STD
•
•
•
•
•
1.00
Selectable Timer Interrupt Disable
Interrupt
11-16
STE
•
•
•
•
•
1.00
Selectable Timer Interrupt Enable
Interrupt
11-16
STS
•
•
•
•
•
3.00
Selectable Timer Interrupt Start
Interrupt
11-17
SUB
•
•
•
•
•
3.00
Subtract
Math
4-5
•
•
•
4.00
Subtract
Math
4-5
SUB
FP
SUS
•
•
•
•
•
2.00
Suspend
Program Flow Control 6-8
SVC
•
•
•
•
•
1.00
Service Communication
Communication
12-3
•
•
•
2.00
SWAP
Math
4-28
•
•
•
2.00
Tangent
Math
4-32
•
•
3.00
Compute Time Difference
Application Specific
7-17
SWP TAN
FP
TDF TND
•
•
•
•
•
1.00
Temporary End
Program Flow Control 6-7
TOD
•
•
•
•
•
2.00
Convert to BCD
Data Handling
5-2
Publication 1747-RM001G-EN-P - November 2008
Page 598
C-18
Memory Usage
Table C.5 SLC 5/03, SLC 5/04 and SLC 5/05 List of Instructions (Continued) Page
OS302, OS401, OS501 Series C, FRN 10+
Instruction Type
OS302, OS401, OS501 Series C
Name
OS302, OS401, OS501
Memory Usage (user words)
OS301, OS400
Applies to SLC
OS300
Mnemonic
TOF
•
•
•
•
•
1.00
Timer Off-delay
Basic
2-10
TON
•
•
•
•
•
1.00
Timer On-delay
Basic
2-9
XIC
•
•
•
•
•
1.00
Examine If Closed
Basic
2-3
XIO
•
•
•
•
•
1.00
Examine If Open
Basic
2-3
XOR
•
•
•
•
•
3.00
Exclusive Or
Data Handling
5-22
•
•
•
3.00
X to the Power of Y
Math
4-33
FP = floating point
XPY (1)
FP
To calculate the memory usage, do the following: Take 2 plus the number of instruction words for each operation performed plus the number of operations performed in the compute. For example, 2 + ADD + SUB + 2 =10.
Publication 1747-RM001G-EN-P - November 2008
Page 599
Memory Usage
C-19
Estimating Total Memory Usage of Your System Using an SLC 5/03, SLC 5/04, or SLC 5/05 Processor
__________
1. Add the total number of data file words used (excluding the status file and I/O data words) and enter the result.
__________
2. Multiply the total number of I/O data words by 3 and enter the result.
__________
3. Multiply the total number of I/O slots, used or unused, by 3 and enter the result.
__________
4. To account for processor overhead, enter 236.
__________
5. Multiply the highest numbered program file used by 5 and enter the result.
__________
6. Multiply the highest numbered program file used by 5 and enter the result.
Subtotal: __________
7. Add steps 1 through 6. Enter this as the subtotal (additional 4K word usage).
4096 - (step 7 value)
8. Subtract the value in step 7 from 4096; if the result is positive, enter 12,288 in step 14. If the result is negative, subtract the absolute value from 12,288 and enter the result in step 14. (This decreases the value.)
__________ __________
9. Calculate the total number of words used by the instructions in your program and enter the result. Refer to Table C.5 on page C-13.
__________
10. Add the total number of rungs (1 word per rung) and enter the result.
__________
11. Add 1 word for each indexed address reference and enter the result.
__________
12. Add 2 words per rung for each rung that contains an indexed address reference and enter the result
Subtotal: __________
13. Add steps 9 through 12 and enter the result.
__________
14. Enter the result from step 8. This is the available memory.
__________
15. Enter the result from step 13. This is the total number of words used.
Total: __________
16. Subtract step 15 from step 14. This number is the amount of memory available to your system.
Publication 1747-RM001G-EN-P - November 2008
Page 600
C-20
Memory Usage
SLC 5/03, SLC 5/04, or SLC 5/05 Memory Usage Example
1747-L532 processor, 30-slot configuration, (15) 1746-IA16, (10) 1746-OA8, (1) 1747-DCM full configuration, (1) 1746-NI4, (1) 1746-NIO4I 100 data words
100 x 1.00
= 100.00
49
I/O data words
49 x 3.00
= 147.00
30 slot
30 x 3.00
= 90.00
Overhead
236.00
10 is the highest data table file number
10 x 5.00
= 50.00
4 is the highest program file number
4 x 5.00
= 20.00
Subtotal
643.00
Account for additional 4K data space 4096 - 643 = 3453 (result is positive; therefore 12,288 words are available) 50
XIC and XIO
50 x 1.00
= 50.00
15
OTE instructions
15 x 1.00
= 15.00
5
TON instructions
5 x 1.00
= 5.00
3
GRT instructions
3 x 3.00
= 9.00
1
SCL instruction
1 x 4.00
= 4.00 t
TOD instruction
1 x 2.00
= 2.00
3
MOV instructions
3 x 2.00
= 6.00
10
CTU instructions
10 x 1.00
= 10.00
10
RES instructions
10 x 1.00
= 10.00
Instruction USage 30 rungs
0 indexed address
0 indexed address reference
30 x 1.00
= 30.00 = 0.00 0.00
Subtotal
141.00
Available memory
12,288.00
Words used Estimated total memory available:
Publication 1747-RM001G-EN-P - November 2008
111.00
- 141.00 12,147.00