Page 181

A-8

Input/Output Quick Reference

Parameter Name (Parameter Group)

Destination M File Location1

Range

Default

Additional Information

Velocity Feed Forward Constant (Servo Loop)

M0:s.32,s.33

0.0 to 1.0

0.0

This parameter is active only when the Loop Closure Method is set to velocity feedforward. Units are in percentage and represent the portion of the velocity command controlled by the pre–calculated final velocity. The percent of following error (incremental to the standard position loop algorithm) is inversely proportional to the value of this variable. For example, setting the feedforward constant to 0.9 (90%) means that the SLC Servo Module applies 90% of the precalculated final velocity to the velocity command. The servo runs at the commanded velocity with only 10% of the following error it would have by using the standard position loop algorithm, providing the system is calibrated properly. A value of 0.0 for this parameter applies 100% velocity feedforward action.

Acceleration Feed Forward Constant (Servo Loop)

M0:s.34,s.35

0.0 to 1.0

0.0

This parameter is active only when the Loop Closure Method is set to feedforward. Units are in percentage and represent the portion of the velocity command to be controlled by the pre–calculated final acceleration. The acceleration feedforward constant is similar to velocity feedforward constant in terms of range checking. In certain applications that require the servo loop to closely follow the command position, use this parameter to reduce the following error that occurs on transitioning from current speed to the new speed (i.e., accelerating or decelerating). If the system is calibrated correctly, zero following error is achieved by using velocity feedforward of 1.0, but the system still generates following errors on transitions. Use the acceleration feedforward parameter to reduce the following error occurring on transitions. A value of 0.0 for this parameter applies 0% acceleration feedforward action.

Home Tolerances – Position Units (Homing)

M0:s.36,s.37

0.0 to axis travel limit

0.1

When the actual position is within the position band of the home position, the At Home bit is set.

Publication 1746-6.1.2 - July 2000

Page 182

Input/Output Quick Reference

Parameter Name (Parameter Group)

Destination M File Location1

Excess Following Error M0:s.38,s.39 Limit –Position Units (Servo Loop)

Range

Default

Additional Information

0.0 to axis travel limit

3.0

Use this formula to calculate the value for the Excess Following Error Parameter =

A-9

(Maximum Axis Speed) x (% max following error) (Maximum Axis Gain Value) (1000)

where: % maximum following error is the percentage of following error when the axis is at the maximum speed you want the fault for Excess Following Error to occur. It is expressed as a decimal value. 1000 is gain scale factor. For example, if Maximum Axis Gain Value is 1, Maximum Axis Speed is 1200 ipm and the excess following error fault occurs at 110% of the following error at axis maximum speed, then Excess Following Error equals: (1200 ipm)(1.1)

= 1.32 in

(1 ipm/mil)(1000 mil/in) In-position Band – Position Units (Motion)

M0:s.40,s.41

0.0 to axis travel limit

0.1

This parameter uses the SLC Application Program to determine the end of move when the application requires accurate positioning to the end point for the move. Typical setting = 4/counts per position unit (as a minimum).

Maximum Axis Gain Value – Position Units per Minute per One Thousandth of the Position Unit (Servo Loop)

M0:s.42,s.43

0.0 to 10.0

1.0

Set this parameter to the maximum gain that the axis can handle without becoming unstable. This parameter is set up at axis integration time. Refer to the Setting Up Your Servo Module chapter in this manual for more information.

1 s = Slot number for the SLC Servo Module.

Commands

Output Commands Use the following tables to locate word 0, word 1, word 2, word 3, word 4, and word 5 output commands.

Publication 1746-6.1.2 - July 2000

Page 183

A-10

Input/Output Quick Reference

Discrete Bit Output Command (Word 0) Location1 O:s.0/0 O:s.0/1 O:s.0/2 O:s.0/3 O:s.0/4 O:s.0/5 O:s.0/6 O:s.0/7 O:s.0/8 O:s.0/9 through O:s.14 O:s.0/15 1

Bit Specifications Estop Request Retract Position Hold/Unhold Move Cancel Move Reserved Execute Synchronized Move Initialize Retract Position Turn On / Off Fast Output Turn On / Off Module Requests for Service Reserved Mode Flag s = Slot number for the SLC Servo Module.

Discrete Bit Output Command (Word 1) Location1 O:s.1/0 O:s.1/1 O:s.1/2 O:s.1/3 through O:s.13 O:s.1/8 O:s.1/9 O:s.1/10 through O:s.15 1

Bit Specifications Reserved Reserved On Home Limit Reserved Clear Faults Clear All Faults Reserved s = Slot number for the SLC Servo Module.

Incremental Position Output Command (Words 2 and 3) Name

Location1

Format

Incremental Position Command

O:s.2, O:s.3

STDFLOAT

Possible Values2

Default 0

1 s = Slot number for the SLC Servo Module. 2 The maximum value allowed is the incremental position in position units equal to ±32767 encoder edges.

Publication 1746-6.1.2 - July 2000

Page 184

Input/Output Quick Reference

A-11

Block Output Command (Word 4) Location1 O:s.4/0 O:s.4/1 O:s.4/2 O:s.4/3 O:s.4/4 O:s.4/5 through O:s.4/ 14 O:s.4/15 1

Bit Specifications Absolute Move Incremental Move Speed Move Monitor Move Run Blend Move Profile Reserved Plan Synchronized Move s = Slot number for the SLC Servo Module.

Block Output Command (Word 5) Location1 O:s.5/0 O:s.5/1 O:s.5/2 O:s.5/3 O:s.5/4 O:s.5/5 though O:s.5/7 O:s.5/8 O:s.5/9 O:s.5/10 O:s.5/11 O:s.5/12 O:s.5/13 through O:s.5/15

Bit Specifications Home Axis Set Home Set Retract Position Preset Position Set Offset Reserved Set In-position Band Set Excess Following Error Limit Set Axis Gain Set VFF Reserved Reserved

1 s = Slot number for the SLC Servo Module.

Discrete Bit Input Status Specifications Use the following tables to locate word 0, word 1, word 2, and word 3, discrete bit input status specifications.

Word 0 Bit Specifications Location1 I:s.0/0 through I:s.0/10 Series / Major Rev / Minor Rev; Blend Move Profile Segment I:s.0/11 through I:s.0/ Reserved 15

Publication 1746-6.1.2 - July 2000

Page 185

A-12

Input/Output Quick Reference

1 s = Slot number for the SLC Servo Module.

Word 1 Location1 I:s.1/0 I:s.1/1 I:s.1/2 I:s.1/3 I:s.1/4 I:s.1/5 I:s.1/6 through I:s.1/7 I:s.1/8 I:s.1/9 I:s.1/10 I:s.1/11 I:s.1/12 I:s.1/13 I:s.1/14 I:s.1/15 1

Bit Specifications Axis Ready Estop State Information Message Minor Fault Major Fault Fault FIFO Full Reserved Axis Needs Homed Homing Retract Position At Home Overtravel – Overtravel + Configuration Failed Configuration Successful s = Slot number for the SLC Servo Module.

Word 2 Location1 I:s.2/0 I:s.2/1 I:s.2/2 I:s.2/3 I:s.2/4 I:s.2/5 I:s.2/6 through I:s.2/7 I:s.2/8 I:s.2/9 I:s.2/10 I:s.2/11 I:s.2/12 through I:s.2/ 15 1

Publication 1746-6.1.2 - July 2000

Bit Specifications In-position Move Complete Axis Stopped Axis Held Accelerating Decelerating Reserved FIN[1] State FIN[2] State FIN[3] State FOUT State Reserved s = Slot number for the SLC Servo Module.

Page 186

Input/Output Quick Reference

A-13

Word 3 Location1 I:s.3/0 I:s.3/1 I:s.3/2 I:s.3/3 I:s.3/4 I:s.3/5 through I:s.3/12 I:s.3/13 I:s.3/14 I:s.3/15

Bit Specifications Absolute Move in Progress Incremental Move in Progress Speed Move in Progress Monitor Move in Progress Blend Move in Progress Reserved Blend Move Profile Configuration in Progress Servo Configuration in Progress Synchronized Move Ready

1 s = Slot number for the SLC Servo Module.

SLC Servo Module to SLC Processor Discrete Control Status Block Command Parameters Informational Message or Fault Code Reserved Actual Position Following Error Current Speed

Use the table below to locate SLC Servo Module to SLC processor discrete control status bits.

Location1 I:s.4

Format

Possible Values

Default

USHORT

0 to 65,535

0

I:s.5 I:s.6-I:s.7 I:s.8-I:s.9 I:s.10-I:s.11

STDSHORT FLOAT FLOAT FLOAT

–32,767 to +32,767 –axis travel limit to +axis travel limit –axis travel limit to +axis travel limit –physical limit to +physical limit

0 0.0 0.0 0.0

1 s = Slot number for the SLC Servo Module.

Publication 1746-6.1.2 - July 2000

Page 187

A-14

Input/Output Quick Reference

Blended Configuration

Use the table below with the Blend Move Output Profile (word 0, bit 14) .

Block Command Parameters Destination M File Location1 Blend Move Profile M0:s.0 Number of Blend Points M0:s.1 % Acceleration Ramp 1 M0:s.2-s.3 Speed 1 M0:s.4-s.5 Absolute Position 1 M0:s.6-s.7 % Acceleration Ramp 2 M0:s.8-s.9 Speed 2 M0:s.10-s.11 Absolute Position 2 M0:s.12-s.13 Reserved % Acceleration Ramp 32 M0:s.188-s.189 Speed 32 M0:s.190-s.191 Absolute Position 32 M0:s.192-s.192

Format

Possible Values

Default

BITS USHORT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT

11XX XXXX XXXX PPPP 1 to 32 0.0 to 1.0 0.0 to +physical limit –axis travel limit to +axis travel limit 0.0 to 1.0 0.0 to +physical limit –axis travel limit to +axis travel limit

0 0 1.0 0.0 0.0 1.0 0.0 0.0

FLOAT FLOAT FLOAT

0.0 to 1.0 0.0 to +physical limit –axis travel limit to +axis travel limit

1.0 0.0 0.0

1 s = Slot number for the SLC Servo Module.

Publication 1746-6.1.2 - July 2000

Page 188

Appendix

B

Cable Dimensions and Wiring Diagram

1746-HCA Cable

1

This appendix contains the dimensions and wiring diagram for the 1746-HCA cable (Figure B.1).

Publication 1746-6.1.2 - July 2000

Page 189

B-2

Cable Dimensions and Wiring Diagram

Figure B.1 1746-HCA Cable Dimensions and Wiring Diagram

Pin 1 25-pin D- sub connector (AMP 205208-3 male or equivalent)

2.1m (84in.) 37-pin D -sub connector (AMP 205210-3 male or equivalent)

25 P O S

37 P O S

13

19

C hannel A

25

18

C hannel A

Pin 1

37

A Shield

23

14

C ha nn el Z

11

15

C hannel Z

33

Z Shield

24

16

C hannel B

17

C hannel B

12 10 22 9

35

B Shield

13 32

D rive Drive R eturn Estop Status

21

11 30

8

10

Estop Reset Request

20

+5V

29

+5V R eturn

7

9

Reset PB

19

28

+15V String Out

6

8

18

27

+15V R eturn

5

6

FIN 1

17

25

15V R eturn

4

5

FIN 2

16

24

15V

3

4

FIN 3

15

23

Spare

2

3

FOUT 1

14

22

Spare

1

1

Spare

NC

20

Spare

Publication 1746-6.1.2 - July 2000

Page 190

Appendix

C

Programming Examples

This appendix provides ladder rung diagrams and any associated data tables that can help you to construct actual programs for the SLC Servo Module using the SLC processor. The ladder rung diagrams provide examples for triggering a configuration, downloading a configuration, setting a timer delay, checking for download errors, and clearing fault errors. The rung diagrams also show how to initiate the following commands: ABSOLUTE move, INCREMENTAL move, SPEED move, MONITOR move, BLEND move, and HOME AXIS move. The command file N31:0 has the following command values: Value

Command

1

Absolute

2

Incremental

4

Speed

8

Monitor

16

Blend

The command file B3:0 has the following command bit:

SLC Servo Module

Value

Command b3:0/10 = 1

Home

The following diagram shows an example of a rack with the SLC Servo Module positioned in slot 1. Figure C.1 SLC Rack with Servo Module in Slot 1

1

SLC 5/04

1746 HSRV

1746 IW16

0

1

2

Publication 1746-6.1.2 - July 2000