The text of a spec sheet · part 2 of 23
SLC Servo Control Module (Catalog No. 1746-HSRV) User Manual, pages 11 to 20
Pages 11 to 20 of 224
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 1746-HS
Page 11
Table of Contents viii
Publication 1746-6.1.2 - July 2000
Page 12
Preface Read this preface to familiarize yourself with the rest of the manual. This preface covers the following topics: • who should use this manual • purpose of this manual • safety precautions • contents of this manual • related documentation • conventions used in this manual • receiving and storage information • Allen-Bradley support
Who Should Use this Manual
Use this manual if you are responsible for designing, installing, programming, or troubleshooting the SLC™ Servo Module (catalog number 1746-HSRV). If you do not have a basic understanding of SLC 500™ products, understand programmable controllers or cannot interpret the ladder logic instructions required to control your application, contact your local Allen-Bradley representative for information on available training courses before using this product. We recommend that you review one of the following before using the software: Publication
Publication Number
Getting Results with RSLogix 500
9399-RL50GR
AI Series Installation Guide
9399-AIIG
Purpose of this Manual
This manual is a user guide for the SLC Servo Module (catalog number 1746-HSRV). It gives you an overview of the SLC Servo Module and describes the procedures you use to install, set up, use, and troubleshoot the SLC Servo Module.
Safety Precautions
The following general precautions apply to the SLC Servo Control Module.
1
Publication 1746-6.1.2 - July 2000
Page 13
Preface
P-2
ATTENTION
!
Only those familiar with the SLC Servo Control Module and associated machinery should plan or implement the installation, start-up, and subsequent maintenance of the system. Failure to comply can result in personal injury and/or equipment damage. This product contains stored energy devices. To avoid hazard of electrical shock, verify that all voltage on the capacitors has been discharged before attempting to service, repair, or remove this unit. You should only attempt the procedures in this manual if you are qualified to do so and familiar with solid-state control equipment and the safety procedures in publication NFPA 70E. The system integrator is responsible for local safety and electrical codes.
ATTENTION
!
An incorrectly applied or installed controller can result in component damage or a reduction in product life. Wiring or application errors, such as undersizing the motor, incorrect or inadequate AC supply, or excessive ambient temperatures can result in malfunction of the drive. This product contains ESD (Electrostatic Discharge) sensitive parts and assemblies. Static control precautions are required when installing, testing, servicing, or repairing this assembly. Component damage can result if ESD control procedures are not followed. If you are not familiar with static control procedures, refer to Allen-Bradley publication 8000-4.5.2, Guarding Against Electrostatic Damage or any other applicable ESD Protection Handbook.
Contents of this Manual
Publication 1746-6.1.2 - July 2000
This manual provides specific information relevant to the SLC Servo Module. The following table identifies the chapters, titles, and contents.
Page 14
Preface
P- 3
Chapter
Title
Contents
1
Overview of the SLC Servo Module
Overview information about the product, its operation and hardware features. Describes interface selection, the module’s use of inputs and outputs, and operating modes.
2
Selecting Power Supplies, Encoders and Drives
Information about selecting the hardware to support an SLC Servo Module.
3
Planning Hardware Installation
Interconnection diagrams for various hardware interfaces for communication with the SLC Servo Module.
4
Installing Your SLC Servo Module
Installation information.
5
Wiring the SLC Servo Module
Information about wiring fast inputs, outputs, Estop connections, power supplies, encoders and drive connections.
6
Testing Your SLC Servo Module Hardware
Information about powering up the SLC Servo Module, testing the Estop and the fast I/O, integrating the axis and testing the homing function.
7
Setting Up and Configuring Your SLC Servo Module
Information about applying power and configuring the SLC Servo Module using command parameters.
8
Programming the SLC Processor to Run the SLC Servo Module
Information about blend move profiles, module communication interface, command, and status information. Describes discrete bit and block commands from the SLC Servo Module.
9
Programming System Variables
Describes discrete block commands for programming position and online system variables from the SLC processor. Information to understand servo module and processor status information.
Publication 1746-6.1.2 - July 2000
Page 15
Preface
P-4
Related Documentation
Chapter
Title
Contents
10
Troubleshooting
Information about troubleshooting and error handling.
Appendix A
Input/Output Quick Reference
A quick reference of parameters, commands, status specifications, and move profiles.
Appendix B
Cable Specifications
Specifications and wiring diagram for 1746-HCA cable.
Appendix C
Application Examples
Applications examples for constructing programs using the SLC processor.
Appendix D
Wiring Without the Termination Panel
Information you need to wire the SLC Servo Module without a termination panel.
The following documents contain additional information concerning Allen-Bradley SLC Servo and SLC products. To obtain a copy, contact your local Allen-Bradley office or distributor.
For:
Read this Document:
Document Number:
An overview of the SLC 500 family of products
SLC 500 Controller System Overview
1747-2.30
A description of how to install and use your Modular SLC 500 programmable controller
SLC 500 Modular Hardware Style Installation & Operation Manual
1747-6.2
A description of how to install and use your Fixed SLC 500 programmable controller
SLC 500 Fixed Hardware Style Programmable Controllers Installation & Operation Manual
1747-621
A training and quick reference guide for APS
SLC 500 Software Programmer’s Quick Reference Guide
ABT-1747-TSG001
In-depth information on grounding and wiring Allen-Bradley programmable controllers
Industrial Automation Wiring and Grounding Guidelines
1770-4.1
An article on wire sizes and types for grounding electrical equipment
National Electrical Code
Published by the National Fire Protection Association of Boston, MA
A complete listing of current Allen-Bradley documentation, including ordering instructions. Also indicates whether the documents are available on CD-ROM or in multiple languages
Allen-Bradley Publication Index
SD499
A glossary of industrial automation terms and abbreviations
Allen-Bradley Industrial Automation Glossary
AG-7.1
Publication 1746-6.1.2 - July 2000
Page 16
Preface
Conventions Used in this Manual
P- 5
The following conventions are used throughout this manual: • Bulleted lists provide information, not procedural steps. • Numbered lists provide sequential steps or hierarchical information. • Words that you type or select appear in bold. • Key names match the names shown and appear in capital letters. • We use this symbol to represent a twisted pair: Figure 0.1 Twisted Pair Symbol Twisted Pair
• We use this symbol to represent a shielded twisted pair: Figure 0.2 Shielded Twisted Pair Symbol Shielded Twisted Pair
Product Receiving and Storage Responsibility
You are responsible for thoroughly inspecting the equipment before accepting the shipment from the freight company. Check the item(s) you receive against your purchase order. If any items are obviously damaged, it is your responsibility to refuse delivery until the freight agent has noted the damage on the freight bill. Should you discover any concealed damage during unpacking, you are responsible for notifying the freight agent. Leave the shipping container intact and request that the freight agent make a visual inspection of the equipment.
Publication 1746-6.1.2 - July 2000
Page 17
Preface
P-6
Leave the product in its shipping container prior to installation. If you are not going to use the equipment for a period of time, store it: • in a clean, dry location • within an ambient temperature range of 0° to 65°C (32° to 149°F) • within a relative humidity range of 5% to 95%, non-condensing • in an area where it cannot be exposed to a corrosive atmosphere • in a non-construction area
Rockwell Automation Support
Rockwell Automation offers support services worldwide, with over 75 sales/support offices, 512 authorized distributors, and 260 authorized systems integrators located throughout the United States. In addition, Rockwell Automation representatives are located in every major country in the world.
Local Product Support Contact your local Rockwell Automation representative for: • sales and order support • product technical training • warranty support • support service agreements
Technical Product Assistance If you need to contact Rockwell Automation for technical assistance, please review the information in the Troubleshooting chapter first. Then call your local Rockwell Automation representative. For the quickest possible response, we recommend that you have the catalog number of your products available when you call. The Rockwell Automation Technical Support number is: 1-603-443-5419
Publication 1746-6.1.2 - July 2000
Page 18
Preface
On the Web
P- 7
For information about Allen-Bradley, visit the following World Wide Web site: http://www.ab.com/
Publication 1746-6.1.2 - July 2000
Page 19
Preface
P-8
Publication 1746-6.1.2 - July 2000
Page 20
Chapter
1
Overview of the SLC Servo Module
This chapter explains the basic functions of the SLC Servo Module, and its hardware requirements. This chapter includes the following SLC Servo Module topics: • Overview • Operation • Specifications and compatibility
SLC Servo Module Overview
The SLC Servo Module (catalog number 1746-HSRV) is compatible with the SLC 500 family and only used with SLC 5/03™ FRN 5.0, SLC 5/04™, or SLC 5/05™ SLC Servo Modules. The SLC Servo Module is programmed for incremental, absolute or speed moves, depending on the application. IMPORTANT
1
Place the SLC Servo Module as close to the SLC processor as possible
Publication 1746-6.1.2 - July 2000