Page 11

Table of Contents viii

Publication 1746-6.1.2 - July 2000

Page 12

Preface Read this preface to familiarize yourself with the rest of the manual. This preface covers the following topics: • who should use this manual • purpose of this manual • safety precautions • contents of this manual • related documentation • conventions used in this manual • receiving and storage information • Allen-Bradley support

Who Should Use this Manual

Use this manual if you are responsible for designing, installing, programming, or troubleshooting the SLC™ Servo Module (catalog number 1746-HSRV). If you do not have a basic understanding of SLC 500™ products, understand programmable controllers or cannot interpret the ladder logic instructions required to control your application, contact your local Allen-Bradley representative for information on available training courses before using this product. We recommend that you review one of the following before using the software: Publication

Publication Number

Getting Results with RSLogix 500

9399-RL50GR

AI Series Installation Guide

9399-AIIG

Purpose of this Manual

This manual is a user guide for the SLC Servo Module (catalog number 1746-HSRV). It gives you an overview of the SLC Servo Module and describes the procedures you use to install, set up, use, and troubleshoot the SLC Servo Module.

Safety Precautions

The following general precautions apply to the SLC Servo Control Module.

1

Publication 1746-6.1.2 - July 2000

Page 13

Preface

P-2

ATTENTION

!

Only those familiar with the SLC Servo Control Module and associated machinery should plan or implement the installation, start-up, and subsequent maintenance of the system. Failure to comply can result in personal injury and/or equipment damage. This product contains stored energy devices. To avoid hazard of electrical shock, verify that all voltage on the capacitors has been discharged before attempting to service, repair, or remove this unit. You should only attempt the procedures in this manual if you are qualified to do so and familiar with solid-state control equipment and the safety procedures in publication NFPA 70E. The system integrator is responsible for local safety and electrical codes.

ATTENTION

!

An incorrectly applied or installed controller can result in component damage or a reduction in product life. Wiring or application errors, such as undersizing the motor, incorrect or inadequate AC supply, or excessive ambient temperatures can result in malfunction of the drive. This product contains ESD (Electrostatic Discharge) sensitive parts and assemblies. Static control precautions are required when installing, testing, servicing, or repairing this assembly. Component damage can result if ESD control procedures are not followed. If you are not familiar with static control procedures, refer to Allen-Bradley publication 8000-4.5.2, Guarding Against Electrostatic Damage or any other applicable ESD Protection Handbook.

Contents of this Manual

Publication 1746-6.1.2 - July 2000

This manual provides specific information relevant to the SLC Servo Module. The following table identifies the chapters, titles, and contents.

Page 14

Preface

P- 3

Chapter

Title

Contents

1

Overview of the SLC Servo Module

Overview information about the product, its operation and hardware features. Describes interface selection, the module’s use of inputs and outputs, and operating modes.

2

Selecting Power Supplies, Encoders and Drives

Information about selecting the hardware to support an SLC Servo Module.

3

Planning Hardware Installation

Interconnection diagrams for various hardware interfaces for communication with the SLC Servo Module.

4

Installing Your SLC Servo Module

Installation information.

5

Wiring the SLC Servo Module

Information about wiring fast inputs, outputs, Estop connections, power supplies, encoders and drive connections.

6

Testing Your SLC Servo Module Hardware

Information about powering up the SLC Servo Module, testing the Estop and the fast I/O, integrating the axis and testing the homing function.

7

Setting Up and Configuring Your SLC Servo Module

Information about applying power and configuring the SLC Servo Module using command parameters.

8

Programming the SLC Processor to Run the SLC Servo Module

Information about blend move profiles, module communication interface, command, and status information. Describes discrete bit and block commands from the SLC Servo Module.

9

Programming System Variables

Describes discrete block commands for programming position and online system variables from the SLC processor. Information to understand servo module and processor status information.

Publication 1746-6.1.2 - July 2000

Page 15

Preface

P-4

Related Documentation

Chapter

Title

Contents

10

Troubleshooting

Information about troubleshooting and error handling.

Appendix A

Input/Output Quick Reference

A quick reference of parameters, commands, status specifications, and move profiles.

Appendix B

Cable Specifications

Specifications and wiring diagram for 1746-HCA cable.

Appendix C

Application Examples

Applications examples for constructing programs using the SLC processor.

Appendix D

Wiring Without the Termination Panel

Information you need to wire the SLC Servo Module without a termination panel.

The following documents contain additional information concerning Allen-Bradley SLC Servo and SLC products. To obtain a copy, contact your local Allen-Bradley office or distributor.

For:

Read this Document:

Document Number:

An overview of the SLC 500 family of products

SLC 500 Controller System Overview

1747-2.30

A description of how to install and use your Modular SLC 500 programmable controller

SLC 500 Modular Hardware Style Installation & Operation Manual

1747-6.2

A description of how to install and use your Fixed SLC 500 programmable controller

SLC 500 Fixed Hardware Style Programmable Controllers Installation & Operation Manual

1747-621

A training and quick reference guide for APS

SLC 500 Software Programmer’s Quick Reference Guide

ABT-1747-TSG001

In-depth information on grounding and wiring Allen-Bradley programmable controllers

Industrial Automation Wiring and Grounding Guidelines

1770-4.1

An article on wire sizes and types for grounding electrical equipment

National Electrical Code

Published by the National Fire Protection Association of Boston, MA

A complete listing of current Allen-Bradley documentation, including ordering instructions. Also indicates whether the documents are available on CD-ROM or in multiple languages

Allen-Bradley Publication Index

SD499

A glossary of industrial automation terms and abbreviations

Allen-Bradley Industrial Automation Glossary

AG-7.1

Publication 1746-6.1.2 - July 2000

Page 16

Preface

Conventions Used in this Manual

P- 5

The following conventions are used throughout this manual: • Bulleted lists provide information, not procedural steps. • Numbered lists provide sequential steps or hierarchical information. • Words that you type or select appear in bold. • Key names match the names shown and appear in capital letters. • We use this symbol to represent a twisted pair: Figure 0.1 Twisted Pair Symbol Twisted Pair

• We use this symbol to represent a shielded twisted pair: Figure 0.2 Shielded Twisted Pair Symbol Shielded Twisted Pair

Product Receiving and Storage Responsibility

You are responsible for thoroughly inspecting the equipment before accepting the shipment from the freight company. Check the item(s) you receive against your purchase order. If any items are obviously damaged, it is your responsibility to refuse delivery until the freight agent has noted the damage on the freight bill. Should you discover any concealed damage during unpacking, you are responsible for notifying the freight agent. Leave the shipping container intact and request that the freight agent make a visual inspection of the equipment.

Publication 1746-6.1.2 - July 2000

Page 17

Preface

P-6

Leave the product in its shipping container prior to installation. If you are not going to use the equipment for a period of time, store it: • in a clean, dry location • within an ambient temperature range of 0° to 65°C (32° to 149°F) • within a relative humidity range of 5% to 95%, non-condensing • in an area where it cannot be exposed to a corrosive atmosphere • in a non-construction area

Rockwell Automation Support

Rockwell Automation offers support services worldwide, with over 75 sales/support offices, 512 authorized distributors, and 260 authorized systems integrators located throughout the United States. In addition, Rockwell Automation representatives are located in every major country in the world.

Local Product Support Contact your local Rockwell Automation representative for: • sales and order support • product technical training • warranty support • support service agreements

Technical Product Assistance If you need to contact Rockwell Automation for technical assistance, please review the information in the Troubleshooting chapter first. Then call your local Rockwell Automation representative. For the quickest possible response, we recommend that you have the catalog number of your products available when you call. The Rockwell Automation Technical Support number is: 1-603-443-5419

Publication 1746-6.1.2 - July 2000

Page 18

Preface

On the Web

P- 7

For information about Allen-Bradley, visit the following World Wide Web site: http://www.ab.com/

Publication 1746-6.1.2 - July 2000

Page 19

Preface

P-8

Publication 1746-6.1.2 - July 2000

Page 20

Chapter

1

Overview of the SLC Servo Module

This chapter explains the basic functions of the SLC Servo Module, and its hardware requirements. This chapter includes the following SLC Servo Module topics: • Overview • Operation • Specifications and compatibility

SLC Servo Module Overview

The SLC Servo Module (catalog number 1746-HSRV) is compatible with the SLC 500 family and only used with SLC 5/03™ FRN 5.0, SLC 5/04™, or SLC 5/05™ SLC Servo Modules. The SLC Servo Module is programmed for incremental, absolute or speed moves, depending on the application. IMPORTANT

1

Place the SLC Servo Module as close to the SLC processor as possible

Publication 1746-6.1.2 - July 2000