Page 122

Appendix

B

The 1771-Remote I/O Network This appendix provides a brief introduction about the 1771–Remote I/O Network. For information on the 1771–Remote I/O Network, see the Direct Communication Module User Manual, Catalog Number 1747–NM007 and the Remote I/O Scanner User Manual, Catalog Number 1747–NM005.

1771-Remote I/O Network

The Allen–Bradley 1771–Remote I/O Network enables chassis of I/O, operator interface terminals, push–button panels, blocks of I/O, message displays, drives and much more to be great distances from the host PLC processor. The SLC 500 controller (fixed, 5/01, 5/02, or 5/03) can interface to this network through the 1747–DCM module for distributed processing. The DCM allows the SLC 500 to look like another device on the network. Below is an example of the 1771–Remote I/O Network. PLC-5/15 or PLC-5/25

1747-DCM

Fixed

1747-DCM

1747-DCM SLC 5/02

SLC 5/01

1771-Remote I/O Network PanelView Operator Terminal

With the SLC 5/02 or 5/03 processor, a 1747–SN Remote I/O Scanner can be used as the host of the remote I/O network. With a SLC 5/02 or 5/03 and SN, a PLC is not required on the network.

1747-SN SLC 5/02

PanelView Operator Terminal

1771-Remote I/O Network SLC 5/02 Block I/O

1747-DCM

B–1

Page 123

This page is a scan with no text; see it in the PDF.

Page 124

Appendix

C

RS-232 Communication Interface This appendix provides an overview of the RS–232 communication interface. This appendix also provides information on the following: • RS–232 and SCADA applications • RS–232 communication interface overview • SLC 500 devices that support RS–232 communication • wiring connectors for RS–232 communication

RS-232 and SCADA Applications

RS-232 Communication Interface Overview

RS–232 is a communication interface included under SCADA (Supervisory Control and Data Acquisition) applications. SCADA is a term that refers to control applications that require communication over long distances. For more information about the use of Allen–Bradley equipment in SCADA applications, refer to the Allen–Bradley SCADA Applications Guide, Publication Number ICCG–11.6.

RS–232 is an Electronics Industries Association (EIA) standard that specifies the electrical, mechanical, and functional characteristics for serial binary communication. It provides you with a variety of system configuration possibilities that differ from those offered by DH–485. One of the biggest benefits of RS–232 communication is that it lets you integrate telephone and radio modems into your control system. The distance over which you are able to communicate with certain system devices is virtually limitless. The SLC and PLC products detailed in this appendix that communicate over the RS–232 communication interface also use the DF1 serial communication protocol. DF1 protocol delimits messages, controls message flow, detects and signals errors, and retries after errors are detected.

C–1

Page 125

Appendix C RS-232 Communication Interface

SLC 500 Devices that Support RS-232 Communication

The SLC 500 product line has three other modules, aside from the SLC 5/03 processor, that support the RS–232 communication interface. They are the DH–485 Communication Interface (1770–KF3), the BASIC module (1746–BAS), and the DH–485/RS–232C Interface (1747–KE). All three of these modules can be used with SLC 500 Fixed Controller.

1770-KF3 Module The 1770–KF3 module links host computers with the Allen–Bradley DH–485 Data Highway. The host computer communicates with the 1770–KF3 over an RS232 link using DF1 protocol. Through the 1770–KF3, the host computer can communicate with the nodes on the DH–485 network. For more information on the 1770–KF3 module, see the DH–485 Communication Interface User Manual, Catalog Number 1770–6.5.18.

1747-KE Module The 1747–KE is a communication interface module that acts as a bridge between DH–485 networks and devices requiring DF1 protocol. You can configure the DF1 port on the 1747–KE for RS–232/423, RS–422, or RS–485 devices. Residing in an SLC 500 chassis, the 1747–KE is ideally used as an interface module, linking remote DH–485 networks via a modem to a central host. For more information on the 1747–KE module, see the DH–485/RS–232 Interface Module User Manual, Catalog Number 1747–NU001.

1746-BAS Module The 1746–BAS module, which is programmed using the BASIC language, has two configurable serial ports for interfacing to computers, modems, printers, and other RS–232 compatible devices. You can also use it for off–loading complex math routines from an SLC 500 processor; this conserves valuable ladder logic memory. For more information on the 1746–BAS module, see the SLC 500 BASIC Module Design and Integration Manual, Catalog Number 1746–ND005.

C–2

Page 126

Appendix C RS-232 Communication Interface

Wiring Connectors for RS-232 Communication

To connect Allen–Bradley devices with other devices over RS–232, you must wire the cable connectors so that communication can occur through the cabling, which provide the interface between devices.

Types of RS-232 Connectors The figure below shows male connectors, and their pinout locations, for Allen–Bradley modules.

5 4 3 2 1

9 8 7 6

9-point Connector (Male)

8 7 6 5 4 3 2 1

15 14 13 12 11 10 9

15-point Connector (Male)

13 12 11 10 9 8 7 6 5 4 3 2 1

25 24 23 22 21 20 19 18 17 16 15 14

25-point Connector (Male)

C–3

Page 127

Appendix C RS-232 Communication Interface

DTE Pinout Channel 0, which the 5/03 processor has, is configured as DTE. The pinouts are the same as the 9–pin AT port. DTE 9 pinout

Signal is

Equivalent DTE 15 pinout

Equivalent DTE 25 pinout

1 -DCD Data Carrier Detect

Input

8

8

2 -RXD Received Data

Input

3

3

3 -TXD Transmitted Data

Output

2

2

4 -DTR Data Terminal Ready

Output

11

20

5 -COM Common Return (Signal Ground)

Shared

7

7

6 -DSR Data Set Ready

Input

6

6

7 -RTS Request to Send

Output

4

4

8 -CTS Clear to Send

Input

5

5

9 -NC

Input

No Connection

22 RI Ring Indicator

DCE Pinout Devices such as a modem are DCE. The pinouts on these terminals are wired to interface with DTE. DCE 9 pinout

Signal is

Equivalent DCE 25 pinout

1 -DCD Data Carrier Detect

Output

8

2 -RXD Received Data

Output

3

3 -TXD Transmitted Data

Input

2

4 -DTR Data Terminal Ready

Input

20

5 -COM Common Return (Signal Ground)

Shared

7

6 -DSR Data Set Ready

Output

6

7 -RTS Request to Send

Input

4

8 -CTS Clear to Send

Output

5

9 -RI

Output

22

Ring Indicator

Important: DCE signal names are viewed from a DTE perspective. For example, TXD is a DTE output and also a DCE input.

C–4

Page 128

Appendix C RS-232 Communication Interface

Pin Assignments for Wiring Connectors Use the following pin assignments to wire the connectors of Allen–Bradley control devices with modems and peripheral devices that support RS–232 communication. See the table below to find the wiring diagram that you need. To Connect this Device IBM AT

1747-KE

1746-BAS 1770-KF3 2760-RB

1771-KGM (PLC-2)

1775-KA (PLC-3)

PLC-5 (channel 0)

5130-RM (PLC-5/250)

To this Device

Remarks

See this Page

Modem

Hardware Handshaking Enabled

C-6

Peripheral DTE

Hardware Handshaking Disabled

C-6

Modem

Hardware Handshaking Enabled

C-7

Peripheral DTE

Hardware Handshaking Disabled

C-7

Modem

Hardware Handshaking Enabled

C-8

Peripheral DTE

Hardware Handshaking Disabled

C-8

Modem

Hardware Handshaking Enabled

C-8

Modem

Hardware Handshaking Enabled

C-9

Peripheral DTE

Hardware Handshaking Disabled

C-9

Modem

Hardware Handshaking Enabled

C-10

Peripheral DTE

Hardware Handshaking Disabled

C-10

Modem

Hardware Handshaking Enabled

C-11

Peripheral DTE

Hardware Handshaking Disabled

C-11

Modem

Hardware Handshaking Enabled

C-12

Peripheral DTE

Hardware Handshaking Disabled

C-12

Modem

Hardware Handshaking Enabled

C-13

Peripheral DTE

Hardware Handshaking Disabled

C-13

C–5

Page 129

Appendix C RS-232 Communication Interface

IBM AT to a Modem (Hardware Handshaking Enabled) Modem

9 Pin

25 Pin

25 Pin

9 Pin

IBM AT

GND ➀

8

1

DCD

DCD

1

8

3

2

RXD

RXD

2

3

2

3

TXD

TXD

3

2

20

4

DTR

DTR

4

20

7

5

COM

COM

5

7

6

6

DSR

DSR

6

6

4

7

RTS

RTS

7

4

5

8

CTS

CTS

8

5

22

9

RI

RI

9

22

(DTE)

1

(DCE)

➀ Connect to the shield of the cable.

IBM AT to a 5/03 Processor, 1770–KF3, 1775–KA, 1773–KA, 5130–RM, or PLC–5 (Hardware Handshaking Disabled) ➀ Peripheral Device

➁

➁

9 Pin

25 Pin

DCD

1

8

RXD

TXD

3

2

TXD

RXD

2

3

DTR

DTR

4

20

COM

COM

5

7

DSR

DSR

6

6

4

7

RTS

RTS

7

4

5

8

CTS

CTS

8

5

22

9

RI

25 Pin

9 Pin

IBM AT

GND➂

8

1

DCD

3

2

2

3

20

4

7

5

6

6

(DTE)

1

(DTE)

➀ You can also use cable 1747-CP3. ➁ Jumpers are only needed if you cannot disable the hardware handshaking on the port. ➂ Connect to the shield of the cable.

C–6

➁

➁