Manual · Allen-Bradley
SLC 500 Fixed Hardware Style (Cat. No. 1747-L20, 1747-L30, and 1747-L40 Processors) Installation and Operation Manual
Manual223 pagesPDF 1.7 MB
Installation and operation manual for the Allen-Bradley SLC 500 fixed controllers (1747-L20, -L30, -L40) and the 1747-AIC DH-485 link coupler.
Covers · 7 models
The models it covers
Allen-Bradley 1747-L20BProgrammable controller from$625.006 in stock Allen-Bradley 1747-L20CProgrammable controller from$895.005 in stock Allen-Bradley 1747-L20LProgrammable controller from$325.001 in stock Allen-Bradley 1747-L30DProgrammable controller from$495.001 in stock Summary
What is in it
Allen-Bradley installation and operation manual for the SLC 500 fixed hardware style controllers, catalog numbers 1747-L20, 1747-L30 and 1747-L40. It helps you select hardware, plan the installation, mount and wire the controller and 2-slot expansion chassis, use the high-speed counter, start up, maintain and troubleshoot the system. Appendices cover setting up a DH-485 network with the 1747-AIC isolated link coupler, RS-232 communication, heat dissipation and wiring diagrams with voltage ranges for each fixed controller.
Its parts
- Preface
- Selecting Your Hardware Components
- System Installation Recommendations
- Mounting Your SLC 500 Control System
- Installing Your Hardware Components
- Wiring Your Control System
- Starting Up Your Control System
- Maintaining Your Control System
- Troubleshooting
- Replacement Parts
From the manual
Key facts from this manual
Each line names its page in the PDF.
Allen-Bradley installation and operation manual for the SLC 500 fixed hardware style controllers, catalog numbers 1747-L20, 1747-L30 and 1747-L40. It covers choosing, mounting, wiring, starting up, maintaining and troubleshooting the controllers, and an appendix describes the 1747-AIC isolated link coupler used to join devices to a DH-485 network.
- Link coupler
- 1747-AIC: isolated link coupler joining SLC 500 devices to DH-485, with a 6-position removable terminal block p. 109
- 1747-AIC isolation, reach
- 1747-AIC: 1500 VDC isolation; links devices up to 1219 m (4000 ft); 1747-C11 12 in. processor cable supplied p. 109
- 1747-AIC power
- 1747-AIC: +24 VDC, for example from an NP1 or NP2 desktop model p. 109
- Fixed controller
- 1747-L20, -L30, -L40: processor with 1K instruction capacity, power supply and fixed I/O in one package p. 1, 21
- 20-point I/O
- 1747-L20A: 12 120 V AC in, 8 AC/DC relay out; 1747-L20B: 12 120 V AC in, 8 AC triac out; 1747-L20C: 12 24 V DC sink in with high-speed counter, 8 AC/DC relay out; 1747-L20L: 12 24 V DC source in with high-speed counter, 8 DC transistor sink out p. 24
- 30 and 40-point I/O
- 1747-L30D: 18 24 V DC sink in with high-speed counter, 12 AC triac out; 1747-L40C: 24 24 V DC sink in with high-speed counter, 16 AC/DC relay out p. 24
- Controller power
- Fixed controllers: AC units 85-265 VAC, 47-63 Hz; DC units 21.6-26.4 VDC p. 22
- Sensor power
- 24 VDC, 200mA user power, only on fixed controllers with AC line power and DC inputs p. 22
- Memory backup
- Fixed controllers: capacitor-backed RAM; optional 1747-BA lithium battery, 5-year life; EEPROM or UVPROM module p. 22, 23
- Memory modules
- 1747-M1 1K EEPROM, 1747-M3 1K UVPROM, 1747-M5 adapter socket; 1747-M4 not compatible with the fixed controller p. 30, 104
- Cables
- 1747-C10 processor to peripheral; 1747-C11 processor to link coupler; 1747-C13 specialty module to link coupler p. 104
- Replacement fuses
- 1746-F4 (1.25 A) for AC units, 1746-F5 (1.6 A) for DC units, five per package p. 104
- Scan time
- 8 milliseconds per 1K typical; bit execution 4 microseconds p. 22
- Operating environment
- 0 to 60 C; 5 to 95% humidity without condensation p. 22
What this manual walks you through
- Connecting SLC 500 devices to DH-485 with 1747-AIC couplers p. 109, 110, 111
- Routing the DH-485 cable away from interference p. 111
- Troubleshooting the controller from its status LEDs p. 94, 95, 96, 97, 98
- Clearing a CPU major fault p. 97
- Handling, storing and shipping 1747-BA lithium batteries p. 86, 87
- Choosing EEPROM and UVPROM memory modules p. 30
- Wiring the inputs and outputs of each fixed controller p. 147, 149, 151, 166, 183, 195
- Ordering replacement parts p. 104
Good to know
- Never charge the 1747-BA lithium batteries; an explosion or burns could result. p. 86
- Lithium batteries may not travel on passenger aircraft. p. 87
- The 1747-M4 4K UVPROM does not work in the fixed controller. p. 30
- Keep the DH-485 cable at least five feet from motors, transformers, welders and similar sources. p. 111
- Replace the battery whenever BATTERY LOW is lit if RAM battery backup is wanted. p. 98
Questions this manual answers
How long can a 1747-AIC DH-485 network be?
The communication cable can run at most 1219 m (4000 ft), counted from the first node to the last. p. 111
What cable connects an SLC 500 processor to a 1747-AIC?
The 1747-C11 cable, 304.8 mm (12 in.) long, which comes with the link coupler. p. 109
What replacement fuse fits an SLC 500 fixed AC unit?
The 1746-F4, rated 1.25 A, sold five per package; DC units take the 1746-F5 (1.6 A). p. 104
What battery backs up memory on a 1747-L20 or 1747-L40?
The capacitor holds RAM for a limited time; for longer backup the manual calls for lithium battery 1747-BA. p. 23
Why is CPU FAULT flashing on a new SLC 500 fixed controller?
A flashing CPU FAULT can be the initial factory power-up condition; follow the start-up steps and clear processor memory. p. 97
Contents
Chapters and sections
Each line opens the PDF at its page.
- 1747-6.21, SLC 500 Fixed Hardware Style Installation and Operation Manual2
- Important User Information3
- Summary of Changes4
- Preface16
- 1 - Selecting Your Hardware Components20
- What Your SLC 500 Controller Can Do for You20
- Overview of Your Fixed Control System21
- Fixed Controller Specifications22
- Selecting the 2-Slot Chassis27
- Selecting Discrete I/O Modules27
- Selecting Speciality I/O Modules27
- Selecting Enclosures28
- Selecting Operator Interfaces28
- EEPROM and UVPROM Memory Modules30
- Selecting Isolation Transformers31
- Special Considerations32
- 2 - System Installation Recommendations40
- 3 - Mounting Your SLC 500 Control System50
- 4 - Installing Your Hardware Components56
- 5 - Wiring Your Control System64
83 more lines, from page 64 on
- Defining Sinking and Sourcing64
- 6 - Starting Up Your Control System74
- 7 - Maintaining Your Control System86
- 8 - Troubleshooting92
- 9 - Replacement Parts104
- A - Setting Up the DH-485 Network106
- B - The 1771-Remote I/O Network122
- C - RS-232 Communication Interface124
- D - Calculating Heat Dissipation for the SLC 500 Control System138
- E - Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller144
- Wiring Symbols144
- Wiring and Circuit Diagrams and Voltage Range Locations145
- Catalog Number 1747-L20A (12) 120 VAC Inputs & (8) Relay Outputs147
- Catalog Number 1747-L20B (12) 120 VAC Inputs & (8) Triac Outputs149
- Catalog Number 1747-L20C (12) 24 VDC Sinking Inputs, High-Speed Counter Input & (8) Relay Outputs151
- Catalog Number 1747-L20D (12) 24 VDC Sinking Inputs, High-Speed Counter Input & (8) Triac Outputs154
- Catalog Number 1747-L20E (12) 24 VDC Sinking Inputs, High-Speed Counter Input & (8) Transistor Sourcing Outputs157
- Catalog Number 1747-L20F (12) 24 VDC Sinking Inputs, High-Speed Counter Input & (8) Relay Outputs160
- Catalog Number 1747-L20G + DC - DC (12) 24 VDC Sinking Inputs, High-Speed Counter Input & (8) Transistor Sourcing Outputs163
- Catalog Number 1747-L20L (12) 24 VDC Sourcing Inputs, High-Speed Counter Input & (8) Transistor Sinking Outputs166
- Catalog Number 1747-L20N (12) 24 VDC Sourcing Inputs, High-Speed Counter Input & (8) Transistor Sinking Outputs169
- Catalog Number 1747-L20P (12) 240 VAC Inputs & (8) Triac Outputs172
- Catalog Number 1747-L20R (12) 240 VAC Inputs & (8) Relay Outputs174
- Catalog Number 1747-L30A (18) 120 VAC Inputs & (12) Relay Outputs176
- Catalog Number 1747-L30B (18) 120 Vac Inputs & (12) Triac Outputs178
- Catalog Number 1747-L30C (18) 24 VDC Sinking Inputs, High-Speed Counter Input & (12) Relay Outputs180
- Catalog Number 1747-L30D (18) 24 VDC Sinking Inputs, High-Speed Counter Input & (12) Triac Outputs183
- Catalog Number 1747-L30L (18) 24 VDC Sourcing Inputs, High-Speed Counter Input & (12) Transistor Sinking Outputs186
- Catalog Number 1747-L30P (18) 240 VAC Inputs & (12) Triac Outputs189
- Catalog Number 1747-L40A (24) 120 VAC Inputs & (16) Relay Outputs191
- Catalog Number 1747-L40B (24) 120 VAC Inputs & (16) Triac Outputs193
- Catalog Number 1747-L40C (24) 24 VDC Sinking Inputs, High-Speed Counter Input & (16) Relay Outputs195
- Catalog Number 1747-L40E (24) 24 VDC Sinking Inputs, High-Speed Counter Input & (16) Transistor Sourcing Outputs198
- Catalog Number 1747-L40F (24) 24 VDC Sinking Inputs, High-Speed Counter Input & (16) Relay Outputs201
- Catalog Number 1747-L40L (24) 24 VDC Sourcing Inputs, High-Speed Counter Input & (16) Transistor Sinking Outputs204
- Catalog Number 1747-L40P (24) 240 VAC Inputs & (16) Triac Outputs207
- Glossary210
- Index214
- Back Cover223
The whole text · 26 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 31-3
- Pages 4 to 154-15
- Preface16-19
- 1 - Selecting Your Hardware Components, pages 20 to 2920-29
- 1 - Selecting Your Hardware Components, pages 30 to 3930-39
- 2 - System Installation Recommendations40-49
- 3 - Mounting Your SLC 500 Control System50-55
- 4 - Installing Your Hardware Components56-63
- 5 - Wiring Your Control System64-73
- 6 - Starting Up Your Control System74-85
- 7 - Maintaining Your Control System86-91
- 8 - Troubleshooting92-103
- Pages 104 to 112104-112
- Pages 113 to 121113-121
- Pages 122 to 129122-129
- Pages 130 to 137130-137
- D - Calculating Heat Dissipation for the SLC 500 Control System138-143
- E - Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller, pages 144 to 153144-153
- E - Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller, pages 154 to 163154-163
- E - Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller, pages 164 to 173164-173
- E - Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller, pages 174 to 183174-183
- E - Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller, pages 184 to 193184-193
- E - Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller, pages 194 to 203194-203
- E - Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller, pages 204 to 209204-209
- Glossary210-213
- Pages 214 to 223214-223
The file

