Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 7 of 26

SLC 500 Fixed Hardware Style (Cat. No. 1747-L20, 1747-L30, and 1747-L40 Processors) Installation and Operation Manual: 3 - Mounting Your SLC 500 Control System

Pages 50 to 55 of 223, from SLC 500 Fixed Hardware Style (Cat. No. 1747-L20, 1747-L30, and 1747-L40 Processors) Installation and Operation Manual

The original document is the PDF (1.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 1747-L20A, Allen-Bradley 1747-L20B, Allen-Bradley 1747-L20C, Allen-Bradley 1747-L20L, Allen-Bradley 1747-L30D, Allen-Bradley 1747-AIC and Allen-Bradley 1747-L40C

Page 50

Chapter

3

Mounting Your SLC 500 Control System This chapter provides you with mounting dimensions for the following SLC 500 components:

• • • • •

Mounting Fixed Hardware Style Units

20 I/O fixed controller 30 & 40 I/O fixed controller 2–slot expansion chassis link coupler (AIC) Data Table Access Module (DTAM)

You can mount the fixed hardware style units directly to the back panel of your enclosure using the mounting tabs and #10 and #12 screws. The torque requirement is 3.4 N–m (30 in–lbs) maximum. Dimensions are in millimeters. (Dimensions in parentheses are in inches.)

3–1

Page 51

Chapter 3 Mounting Your SLC 500 Control System

20 I/O Fixed Controller➀ 11 Dia. (0.433)

105 (4.13)

5.5 Dia. (0.217) 20 (0.79)

158 (6.22)

140 (5.51)

14 (0.55) 5.5 (0.217)

105 (4.13)

30 (1.18)

165 (6.50)

5.5 Dia. (0.217)

Front View 1.0 (0.04)

SERIAL NO.

12.5 (0.49)

CAT

171 (6.73)

145 (5.71)

Left Side View

➀

3–2

Dimensions are in millimeters. (Dimensions in parentheses are in inches.)

Page 52

Chapter 3 Mounting Your SLC 500 Control System

30 and 40 I/O Fixed Controller➀ 11 Dia. (0.433)

158 (6.22)

175 (6.89)

5.5 Dia. (0.217) 20 (0.79)

140 (5.51)

14 (0.55) 6.35 (0.25)

175 (6.89)

55.0 (0.217)

260 (10.24)

30.0 (1.18)

5.5 Dia (0.217)

Front View 1.0 (0.04)

SERIAL NO.

CAT

171 (6.73)

145 (5.71)

Left Side View

➀

Dimensions are in millimeters. (Dimensions in parentheses are in inches.)

3–3

Page 53

Chapter 3 Mounting Your SLC 500 Control System

2-Slot Expansion Chassis➀ 80 (3.15) 40 (1.57)

40 (1.57)

5.5 Dia. (0.217) 11 Dia. (0.433)

158 (6.22)

14 (0.55)

5.5 Dia. (0.217)

Front View 1.0 (0.04) 18.5 (0.728)

171 (6.73)

SERIAL NO.

CAT

140 (5.51)

4.83 (0.190)

14 (0.55) 145 (5.71)

Right Side View

➀

3–4

Dimensions are in millimeters. (Dimensions in parentheses are in inches.)

Page 54

Chapter 3 Mounting Your SLC 500 Control System

Link Coupler (AIC)➀ R 2.74 (0.11)

146 (5.75)

R 5.5 (0.22)

172 (6.75) 159 (6.24)

137 (5.41)

14 (0.55) 7.1 (0.28)

38 (1.50)

Front View

4.3 (0.17)

5.5 Dia. (0.216)

Right Side View

Data Table Access Module (DTAM)➀ 69 (2.76)

Comm

127 (5.0)

152 (6.0)

140 (5.5)

Front View

➀

64 (2.5)

Right Side View

Dimensions are in millimeters. (Dimensions in parentheses are in inches.)

3–5

Page 55

This page is a scan with no text; see it in the PDF.