Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 18 of 26

SLC 500 Fixed Hardware Style (Cat. No. 1747-L20, 1747-L30, and 1747-L40 Processors) Installation and Operation Manual: E - Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller, pages 144 to 153

Pages 144 to 153 of 223, from SLC 500 Fixed Hardware Style (Cat. No. 1747-L20, 1747-L30, and 1747-L40 Processors) Installation and Operation Manual

The original document is the PDF (1.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 1747-L20A, Allen-Bradley 1747-L20B, Allen-Bradley 1747-L20C, Allen-Bradley 1747-L20L, Allen-Bradley 1747-L30D, Allen-Bradley 1747-AIC and Allen-Bradley 1747-L40C

Page 144

Appendix

E

Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller This appendix covers the following for your fixed controller. • wiring diagrams • circuit diagrams • voltage ranges

Wiring Symbols

The following table provides an explanation of the symbols used in the wiring diagrams. The symbols do not indicate the only type of I/O devices that can be connected, but rather a “typical” device. As long as your I/O device meets the I/O circuit specifications, it should be compatible. This Symbol

Represents Typical Input Device Mechanical switch Solid-state switch

This Symbol

Represents Typical Output Device Solenoid

CR

Control relay

The connections illustrated in the wiring diagrams are shown for example purposes only. • You can connect I/O devices in any order to the I/O circuits. If you are not going to load all of your circuits, space the connections evenly apart to help in heat dissipation. • All the input circuits on any one fixed controller are the same with one exception: input 0 is unique for all fixed controllers which have 24 VDC input circuits. In this case, input 0 can be used as a high–speed counter. The diagrams in this appendix show the differences in operating characteristics. • All the output circuits on any one fixed controller are the same. In the wiring diagrams for the fixed controller with 24 VDC input circuits and 120/240 VAC line power, the User Power Source (terminals next to Power Supply terminals, “PWR OUT 24 VDC” and “PWR OUT COM”) is shown to power some input devices. This is optional. The User Power Source can provide up to 200mA at 24 VDC for input devices. E–1

Page 145

Appendix E Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller

Wiring and Circuit Diagrams and Voltage Range Locations Catalog Numbers 1747-L20A 1747-L20B 1747-L20C

Description➀ (12) 120 VAC Inputs and (8) Relay Outputs (12) 120 VAC Inputs and (8) Triac Outputs (12) 24 VDC Sinking Inputs, High-Speed Counter Input and (8) Relay Outputs

Wiring Diagram

Input Circuit Diagram

On/Off State Voltage

Output Circuit Diagram

Operating Voltage Range

E-4

E-5

E-5

E-5

E-5

E-6

E-7

E-7

E-7

E-7

E-8

E-9

E-9

E-10

E-10

1747-L20D

(12) 24 VDC Sinking Inputs, High-Speed Counter Input and (8) Triac Outputs

E-11

E-12

E-12

E-13

E-13

1747-L20E

(12) 24 VDC Sinking Inputs, High-Speed Counter Input and (8) Transistor Sourcing Outputs

E-14

E-15

E-15

E-16

E-16

1747-L20F

(12) 24 VDC Sinking Inputs, High-Speed Counter Input and (8) Relay Outputs

E-17

E-18

E-18

E-19

E-19

1747-L20G

(12) 24 VDC Sinking Inputs, High-Speed Counter Input and (8) Transistor Sourcing Outputs

E-20

E-21

E-21

E-22

E-22

1747-L20L

(12) 24 VDC Sourcing Inputs, High-Speed Counter Input and (8) Transistor Sinking Outputs

E-23

E-24

E-24

E-25

E-25

1747-L20N

(12) 24 VDC Sourcing Inputs, High-Speed Counter Input and (8) Transistor Sinking Outputs

E-26

E-27

E-27

E-28

E-28

E-29

E-30

E-30

E-30

E-30

E-31

E-32

E-32

E-32

E-32

E-33

E-34

E-34

E-34

E-34

E-35

E-36

E-36

E-36

E-36

E-37

E-38

E-38

E-39

E-39

1747-L20P 1747-L20R 1747-L30A 1747-L30B 1747-L30C

(12) 240 VAC Inputs and (8) Triac Outputs (12) 240 VAC Inputs and (8) Relay Outputs (18) 120 VAC Inputs and (12) Relay Outputs (18) 120 VAC Inputs and (12) Triac Outputs (18) 24 VDC Sinking Inputs, High-Speed Counter Input and (12) Relay Outputs

1747-L30D

(18) 24 VDC Sinking Inputs, High-Speed Counter Input and (12) Triac Outputs

E-40

E-41

E-41

E-42

E-42

1747-L30L

(18) 24 VDC Sourcing Inputs, High-Speed Counter Input and (12) Transistor Sinking Outputs

E-43

E-44

E-44

E-45

E-45

E-46

E-47

E-47

E-47

E-47

E-48

E-49

E-49

E-49

E-49

1747-L30P 1747-L40A E–2

Use the table below to locate the appropriate wiring and circuit diagrams and voltage ranges.

(18) 240 VAC Inputs and (12) Triac Outputs (24) 120 VAC Inputs and (16) Relay Outputs

Page 146

Appendix E Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller

Wiring Diagram

Input Circuit Diagram

On/Off State Voltage

Output Circuit Diagram

Operating Voltage Range

E-50

E-51

E-51

E-51

E-51

E-52

E-53

E-53

E-54

E-54

1747-L40E

(24) 24 VDC Sinking Inputs, High-Speed Counter Input and (16) Transistor Sourcing Outputs

E-55

E-56

E-56

E-57

E-57

1747-L40F

(24) 24 VDC Sinking Inputs, High-Speed Counter Input and (16) Relay Outputs

E-58

E-59

E-59

E-60

E-60

1747-L40L

(24) 24 VDC Sourcing Inputs, High-Speed Counter Input and (16) Transistor Sinking Outputs

E-61

E-62

E-62

E-63

E-63

1747-L40P

(24) 240 VAC Inputs and (16) Triac Outputs

E-64

E-65

E-65

E-65

E-65

Catalog Numbers 1747-L40B 1747-L40C

Description➀ (24) 120 VAC Inputs and (16) Triac Outputs (24) 24 VDC Sinking Inputs, High-Speed Counter Input and (16) Relay Outputs

➀

Refer to page 1-5 for line power specifications.

E–3

Page 147

Appendix E Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller

Catalog Number 1747-L20A (12) 120 VAC Inputs & (8) Relay Outputs

Wiring Diagram (Hi) L1

(Lo) L2

5-265 VAC or 5-125 VDC 1

CR

(Hi) L1

(Lo) L2

5-265 VAC or 5-125 VDC 1

CR

CR

CR

VAC- OUT 0 OUT 1 OUT 2 OUT 3 VAC- OUT 4 OUT 5 OUT 6 OUT 7 VDC 1 VDC 2

(Hi) L1

(Lo) L2

(Lo) L2

(Hi) L1

85-132 VAC

85-265 VAC

120/240 VAC VAC NEUT CHASSIS GND

NOT USED

NOT USED

AC COM

AC COM

IN 0

IN 1

IN 3 IN 2

IN 5 IN 4

IN 7 IN 6

IN 9 IN 8

IN 11 IN 10

Commons Connected Internally

➀ The outputs are isolated in groups as shown. Therefore, different voltages can be applied to each group as the specific application requires.

E–4

Page 148

Appendix E Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller

Input Circuit Diagram 270

1870

AC COM 1 µF

261

0.3 µ F IN

270

1870

1 µF

261

0.3 µ F IN

On/Off State Voltage Ranges

ÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉ

85 VAC

30 VAC

0 VAC Off-state

Input State Not Guaranteed

132 VAC On-state

Output Circuit Diagram VAC/VDC

OUT

OUT

Operating Voltage Range 0 V 5 VAC 0 V 5 VDC

ÉÉ ÉÉ

265 VAC 125 VDC Recommended Operating Range

Operation Not Guaranteed

E–5

Page 149

Appendix E Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller

Catalog Number 1747-L20B Wiring Diagram (12) 120 VAC Inputs & (8) Triac (Hi) Outputs L1 85-265 VAC

(Lo) L2

1

(Hi) L1 85-265 VAC

CR

(Lo) L2

1

CR

CR

CR

VAC 1 OUT 0 OUT 1 OUT 2 OUT 3 VAC 2 OUT 4 OUT 5 OUT 6 OUT 7

(Hi) L1

(Lo) L2

(Lo) L2

(Hi) L1

85-132 VAC

85-265 VAC

120/240 VAC VAC NEUT CHASSIS GND

NOT USED

NOT USED

AC COM

AC COM

IN 0

IN 1

IN 3 IN 2

IN 5 IN 4

IN 7 IN 6

IN 9 IN 8

IN 11 IN 10

Commons Connected Internally

➀ The outputs are isolated in groups as shown. Therefore, different voltages can be applied to each group as the specific application requires.

E–6

Page 150

Appendix E Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller

Input Circuit Diagram 270

1870

AC COM 1 µF

261

0.3 µ F IN

270

1870

1 µF

261

0.3 µ F IN

On/Off State Voltage Ranges

ÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉ

85 VAC

30 VAC

0 VAC Off-state

Input State Not Guaranteed

132 VAC On-state

Output Circuit Diagram L1

OUT

OUT

Operating Voltage Range

ÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉ 0 VAC

85 VAC

Operation Not Guaranteed

265 VAC Recommended Operating Range

Important: If you measure the voltage at an output terminal that is not connected to a load or is connected to a high-impedance load, you may measure as much as 100 VAC even though the output is off.

E–7

Page 151

Appendix E Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller

Catalog Number 1747-L20C (12) 24 VDC Sinking Inputs, High-Speed Counter Input & (8) Relay Outputs

Wiring Diagram (Hi) L1

5-265 VAC 5-125 VDC

(Lo) L2

(Hi) L1

5-265 VAC 5-125 VDC

1

CR

(Lo) L2 1

CR

CR

CR

VAC- OUT 0 OUT 1 OUT 2 OUT 3 VAC- OUT 4 OUT 5 OUT 6 OUT 7 VDC 1 VDC 2

(Hi) L1

(Lo) L2

85-265 VAC Sourcing Device 120/240 VAC VAC NEUT CHASSIS GND

PWR OUT DC +24VDC 2 COM

PWR OUT DC COM 2 COM

IN 1

IN 0 HSC

IN 3 IN 2

IN 5 IN 4

IN 7 IN 6

IN 9 IN 8

IN 11 IN 10

Commons Connected Internally - DC

10-30 VDC

+ DC

➀ The outputs are isolated in groups as shown. Therefore, different voltages can be applied to each group as the specific application requires.

➁ 24 VDC, 200mA user power is available for sensors.

E–8

Page 152

Appendix E Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller

Input Circuit Diagram 560

560

INPUT 0 (HSC) 0.01 µ F

1. 5K

OTHER INPUTS

390

1. 5K 0.1 µ F

560

COM

On/Off State Voltage Ranges – Input 0 (HSC) 0 VDC

ÉÉÉÉÉ ÉÉÉÉÉ

10 VDC

4 VDC

Off-state

30 VDC On-state

Input State Not Guaranteed

On/Off State Voltage Ranges – All Other Inputs 0 VDC

ÉÉÉÉÉ ÉÉÉÉÉ 5 VDC

Off-state

10 VDC

30 VDC On-state

Input State Not Guaranteed

E–9

Page 153

Appendix E Wiring and Circuit Diagrams and Voltage Ranges for Your Fixed Controller

Output Circuit Diagram VAC/VDC

OUT

OUT

Operating Voltage Range 0 V 5 VAC 0 V 5 VDC

ÉÉ ÉÉ

Operation Not Guaranteed

E–10

265 VAC 125 VDC Recommended Operating Range