Page 210

Glossary

Glossary Auto Answer, The type of modem that has self-contained timeouts and tests. They can answer and hang the phone up automatically. Backplane Current Draw, The amount of current the module requires from the backplane. The sum of the backplane current draw for all modules in a chassis is used to select the appropriate chassis power supply. Baud Rate, The speed of communication between devices on a network. All devices must communicate at the same baud rate. For example, the DH–485 network devices default to 19,200 baud. Calculated Watts, The amount of heat generated by those points energized on an I/O module. Channel, Communication port on a module. Chassis, A hardware assembly that houses devices such as I/O modules, adapter modules, processor modules, and power supplies. Continuous Current Per Module, The maximum current for each module. The sum of the output current for each point should not exceed this value. Continuous Current Per Point, The maximum current each output is designed to continuously supply to a load. CPU, Central Processing Unit or processor. DF1 protocol, A peer–to–peer link–layer protocol that combines features of ANSI X3.28–1976 specification subcategories D1 (data transparency) and F1 (two–way simultaneous transmission with embedded responses). Direct Connect, A type of modem that is connected to a dedicated, leased phone line and is active at all times. DH–485 Network, The DH–485 network is a collection of devices connected to the communication cable allowing information exchange. A communication network based on the EIA Standard for RS–485 using an Allen–Bradley proprietary protocol. DTE Controlled Answer, type of modem that is unattended and is attached directly to the phone lines. The interface module or the 5/03 processor acts as the Data Terminal Equipment (DTE), which controls the modem via the DTR, DSR, and DCD signals. The module incorporates timeouts and tests to properly operate these types of modems.

G–1

Page 211

Glossary

DTR Dialing (5/03 only), type of modem that lets you dial a number or end a call based on the status of the RS–232 DTR (Data Terminal Ready) signal. To program the modem initialization string and phone number into the internal memory of the modem, use a dumb terminal (or PC running terminal emulation software like Procomm, Window’s Terminal, or PBASE). Once you have programmed the modem, activate the DTR signal to dial the number, or deactivate the DTR signal to end the call. EEPROM, Electrically Erasable Programmable Read Only Memory module used to store, back up, or transfer SLC 500 programs. The SLC 500 can read and write to an EEPROM. Flash EPROM, Flash Erasable Programmable Read Only Memory module. It combines the programming versatility of EEPROMs with the security precautions of UVPROMs. This means that you have the option of leaving your EPROM programs write protected or unprotected. Full–duplex, A high performance protocol that allows simultaneous two–way data transmission. For point–to–point applications only. Half–duplex, A high performance protocol that can be used in point–to–point and multi–point applications. Initiator, A node on the DH–485 network capable of acting as a master. When an initiator has the token it can send messages and request replies from any node on the DH–485 network. A personal computer running the SLC 500 Advanced Programming Software is an initiator on the data link. The SLC 5/02 can also be an initiator. Input Device, A device, such as a push button or a switch, that supplies signals through input circuits to a programmable controller. Inrush Current, The temporary surge current produced when a device or circuit is initially energized. I/O, Inputs and Outputs Isolated Link Coupler, The link coupler provides an electrically isolated network connection for an SLC 500 controller (processor or programming station). The link couplers connect the daisy–chained DH–485 communication cable. LED, Light Emitting Diode. Used as status indicator for processor functions and inputs and outputs. Manual, typically an acoustically coupled type of modem. The connection is established by a person on each end of the phone line. They then insert the handsets into an acoustic coupler to complete the connection. Maximum Watts, The maximum amount of heat that the module generates with field power present. Minimum Load Current, The lowest amount of current the output is designed to operate at. Operating at or below this value is not reliable. G–2

Page 212

Glossary

Minimum Watts, The amount of heat dissipation that can occur when there is no field power present. Multi–master network, A network in which more than one node has the ability to initiate communications and initialize the link. Network, A series of stations (nodes) connected by some type of communication medium. A network may be made up of a single link or multiple links. Node, Also called a station. An address or software location on the network. Nominal Input Current, The current at nominal input voltage. Off–State Current, For input circuits, the maximum amount of leakage current allowed from an input device in its Off–state. Off–State Leakage, For output circuits, the maximum amount of (leakage) current that may flow when the output circuit is in its Off–state. Off–State Voltage (max), The maximum input voltage level detected as an Off condition by the input module. On–State Voltage Drop, The voltage developed across the output driver circuit during the On state at maximum load current. Operating Voltage, For inputs, the voltage range needed for the input to be in the On state. For outputs, the allowable range of user–supplied voltage. Output Device, A device, such as a pilot light or a motor starter coil, that is energized by the programmable controller. Points per Common, The number of input or output points connected to a single return (common) or supply (vcc). Protocol, The “language” or packaging of information that is transmitted across a network. (I/O) Rack, An I/O addressing unit that corresponds to 8 input image–table words and 8 output image–table words. A rack can contain a maximum of 8 I/O groups for up to 128 discrete I/O. Remote I/O Network, A network where the communication between the processor and the I/O is across a serial link. Responder, A node on the DH–485 network that acts as a slave device. A responder is not capable of initiating communications. It can only send messages in response to a request from an initiator. The SLC 5/01 and 5/02 can also be responders. RS–232, An EIA standard that specifies electrical, mechanical, and functional characteristics for serial binary communication circuits. A single–ended serial communication interface. G–3

Page 213

Glossary

RTB, Removable Terminal Block. Signal Delay, For inputs, the response time required to transmit the circuit status from the field wiring to the digital logic. For outputs, the time required to transmit the circuit status from digital logic to the output wiring. Sinking, A term used to describe current flow between an I/O device and SLC I/O circuit, typically, a sinking device or circuit provides a path to ground, low, or negative side of power supply. Sinking/Sourcing, Describes a current signal flow relationship between field input and output devices in a control system and their power supply. Sourcing I/O modules supply (or source) current to sinking field devices. Sinking I/O modules receive (or sink) current from sourcing field devices. Sourcing, A term used to describe current flow between an I/O device and SLC I/O circuit, typically, a sourcing device or circuit provides a path to the source, high, or positive side of power supply. Surge Current Per Point, The maximum amplitude and duration (pulse) of current allowed for a given period of time and temperature. Surge Suppressor, A device used to absorb voltage transients created by energizing an inductive load to reduce electrical noise or to protect the output circuit. For example, an R–C network, MOV (metal oxide varistor) or diode. Token, The logical right to initiate communications. In a multi–master network a single token is passed between initiators to make sure two nodes do not transmit at the same time. UVPROM, An Ultra–Violet light erasable Programmable Read Only Memory module used to back up, store, or transfer SLC 500 programs. The SLC 5/01 and 5/02 can only read from a UVPROM. An external PROM programmer is used to program (write to) the device. Voltage Category, The nominal voltage used to describe the module. Watts Per Point, The maximum heat dissipation that can occur in each field wiring point when energized.

G–4