Page 281
Glossary
281 operating voltage For inputs, the voltage range needed for the input to be in the On-state. For outputs, the allowable range of user-supplied voltage. output device A device, such as a pilot light or a motor starter coil, that is energized by the programmable controller. output scan The controller turns on, off, or modifies the devices connected to the output terminals. PCCC (programmable controller communication commands) points per common The number of input or output points connected to a single return (common) or supply (vcc). poll message A poll message is a point-to-point transfer of data sent by the scanner that solicits a response from a single device. The device responds with its data bit and status bit. processor A Central Processing Unit. (See CPU.) processor files The set of program and data files resident in the controller. program file Areas within a processor that contain the logic programs. SLC controllers support multiple program files. program mode When the controller is not scanning the control program. program scan A part of the controller’s operating cycle. During the program scan, the logic program is processed and the Output Image is updated.
Publication 1747-UM011G-EN-P - June 2008
Page 282
282
Glossary programming device Programming package used to develop ladder logic diagrams. protocol The language or packaging of information that is transmitted across a network. (I/O) rack An I/O addressing unit that corresponds to 8 input image-table words and 8 output image-table words. A rack can contain a maximum of 8 I/O groups for up to 128 discrete I/O. read To acquire data. For example, the processor reads information from other devices via a read message. relay An electrically operated device that mechanically switches electrical circuits. relay logic A representation of binary or discrete logic. remote I/O network A network where the communication between the processor and the I/O is across a serial link. restore To transfer a program from a device to a controller. reserved bit A location reserved for internal use. retentive data Information (data) that is preserved through power cycles. RS-232 An EIA standard that specifies electrical, mechanical, and functional characteristics for serial binary communication circuits. Publication 1747-UM011G-EN-P - June 2008
Page 283
Glossary
283
RTB Removable Terminal Block. run mode An executing mode during which the controller scans or executes the logic program. rung A rung contains input and output instructions. During Run mode, the inputs on a rung are evaluated to be true or false. If a path of true logic exists, the outputs are made true (energized). If all paths are false, the outputs are made false (de-energized). save To save a program to a computer hard disk. scan The scan is made up of four elements: input scan, program scan, output scan, and housekeeping. scan time The time required for the controller to complete one scan. signal delay For inputs, the response time required to transmit the circuit status from the field wiring to the digital logic. For outputs, the time required to transmit the circuit status from digital logic to the output wiring. sinking A term used to describe current flow between two devices. A sinking device provides a direct path to ground. sinking/sourcing Describes a current signal flow relationship between field input and output devices in a control system and their power supply. Sourcing I/O modules supply (or source) current to sinking field devices. Sinking I/O modules receive (or sink) current from sourcing field devices.
Publication 1747-UM011G-EN-P - June 2008
Page 284
284
Glossary sourcing A term used to describe current flow between two devices. A sourcing device or circuit provides power. status The condition of a circuit or system. strobe message A strobe message is a multicast transfer of data sent by the scanner that solicits a response from each slave device. The devices respond with their data. surge current per point The maximum amplitude and duration (pulse) of current allowed for a given period of time and temperature. surge suppressor A device used to absorb voltage transients created by energizing an inductive load to reduce electrical noise or to protect the output circuit. For example, an R-C network, MOV (metal oxide varistor) or diode. terminal A point on an I/O module that external devices, such as a push button or pilot light, are wired to. throughput The time between when an input turns on and a corresponding output turns on or off. Throughput consists of input delays, program scan, output delays, and overhead. token The logical right to initiate communication. In a multi-master network a single token is passed between initiators to make sure two nodes do not transmit at the same time. true The status of an instruction that provides a continuous logical path on a ladder rung.
Publication 1747-UM011G-EN-P - June 2008
Page 285
Glossary
285 upload Data is transferred from the controller to a programming or storage device. UVPROM An Ultra-Violet light erasable Programmable Read Only Memory module used to back-up, store, or transfer SLC 500 programs. The SLC 5/01 and SLC 5/02 processor can only read from a UVPROM. An external PROM programmer is used to program (write to) the device. voltage category The nominal voltage used to describe the module. watchdog timer A timer that monitors a cyclical process and is cleared at the conclusion of each cycle. If the watchdog runs past its programmed time period, it causes a fault. watts per point The maximum heat dissipation that can occur in each field wiring point when energized. write To send data to another device. For example, the processor writes data to another device with a message write instruction.
Publication 1747-UM011G-EN-P - June 2008
Page 286
286
Glossary
Notes:
Publication 1747-UM011G-EN-P - June 2008
Page 287
Index Numerics 1746-BAS module 183, 203 1746-C7 cable 108 1746-C9 cable 108 1746-P1 power supply installing 104 replacing fuse 139 1746-P2 power supply installing 104 replacing fuse 139 1746-P3 power supply installing 104 replacing fuse 139 special considerations for grounding 64 1746-P4 power supply installing 104 1747-AIC link coupler connecting the communication cable 194 1747-BA, lithium battery 43, 133, 173 1747-KE module as an RS-232 communication device 203 on the DH-485 network 183 1747-KFC15 module 236 1747-L511 processor 81, 176, 227, 263 1747-L514 processor 81, 176, 227, 263 1747-L524 processor 83, 176, 227, 263 1747-L531 processor 86, 176, 227, 263 1747-L532 processor 86, 176, 227, 263 1747-L533 processor 86, 176, 227, 263 1747-L541 processor 89, 176, 227, 263 1747-L542 processor 89, 176, 227, 263 1747-L543 processor 89, 176, 227, 263 1747-L551 processor 92, 176, 227, 263 1747-L552 processor 92, 176, 227, 263 1747-L553 processor 92, 176, 227, 263 1747-M1 EEPROM 42 1747-M13 44 1747-M2 EEPROM 42 1747-M5 adapter socket 42 1747-NET-DNI interface 265 1747-PIC interface 16, 40, 229, 265 1747-SCNR module 229, 236, 265 1747-SDN module 229, 233, 265 1747-UIC interface 16, 229 description 41, 185 example network 185 function on DH-485 183 Installation Instructions publication 183 1761-NET-AIC interface 40, 229, 265 1761-NET-DNI interface 234, 265
1770-KF3 module 183 1784-KTXD card 226 1784-PCMK card 16 1784-PKTX(D) module 16, 226 1785-KA5 module on the data highway plus network 226 5/01 processors general specifications 176 hardware features 81, 101 status indicators 82 troubleshooting 143 5/02 processor general specifications 176 hardware features 83 installing 101 status indicators 84 troubleshooting 143 5/03 processors active modem-control lines CTS (Clear to Send) 210 DCD (Data Carrier Detect) 211 DSR (Data Set Ready) 210 DTR (Data Terminal Ready) 210 RTS (Request to Send) 210 general specifications 176 hardware features 86 installing 101 keyswitch 95 returning processor to initial factory conditions 161 status indicators 87 troubleshooting 149 5/04 processors active modem-control lines CTS (Clear to Send) 210 DCD (Data Carrier Detect) 211 DSR (Data Set Ready) 210 DTR (Data Terminal Ready) 210 RTS (Request to Send) 210 general specifications 176 hardware features 89 installing 101 keyswitch 95 returning processor to initial factory conditions 161 status indicators 90 troubleshooting 149 5/05 processors Ethernet communication 237 general specifications 176 hardware features 92, 93 installing 101 keyswitch 95 Publication 1747-UM011G-EN-P - June 2008
Page 288
288
Index returning processor to initial factory conditions 161 status indicators 93 troubleshooting 149
A address 271 AIC+ Advanced Interface Converter 271 mounting dimensions 80 ambient temperature rating, processor specification 176 application 271 Article 70B of the NFPA 73 Article 70E of the NFPA 55 ASCII communication 210
B BASIC programming language 203 batteries, lithium Code of Federal Regulations, 49 CFR 173.22a 134 DOT-E7052 provision 134 shipping when depleted 134 storing and handling 133 transportation 134 battery catalog number 173 installation SLC 5/01 or SLC 5/02 processors 136 SLC 5/03 and later processors 137 Belden #9463 cable 224 Belden #9842 cable on the DH-485 network 193 wire/terminal connections 195 bit 271 block diagrams 271 Boolean operators 272 BOOTP configuring SLC 5/05 242-245 using the Rockwell Utility 244 branch 272
C cable routes, planning 190 cables 1746-C7 108 1746-C9 108 Belden #9463 224 Belden #9842 194
Publication 1747-UM011G-EN-P - June 2008 replacement 169 certification power supplies 177 channel 0 pinout 202 chassis 13-slot modular mounting dimensions 76 date shown on 66 installation 17, 75, 98 chassis interconnect cables, installation of 108 clock, real-time SLC 5/03 processor 86 SLC 5/04 processors 89 SLC 5/05 processors 92 Common Power Source 68 communication protocols ASCII 210 data highway plus 221 DF1 full-duplex 204 DF1 half-duplex 205 DF1 radio modem 207 DH-485 202, 221 Ethernet 237 communication scan 272 contact protection diodes 50 RC network 50 surge suppressor 50 varistor 50 contacting Rockwell Automation for assistance 141 control networks Allen-Bradley Remote I/O 231 ControlNet 236 DeviceNet 233 overview 231 remote I/O network 231 control profile 273 control program 272 controller definition 273 features 81 installation 58 overhead 273 selecting 31 spacing 58 specifications 176 troubleshooting 141 ControlNet Messaging module 236 ControlNet network 236 1747-KFC15 module 236
Page 289
Index
1747-SCNR module 236 ControlNet scanner 236 counters definition 273 CPU (central processing unit), definition 273 CTS (Clear to Send) 210
D Data Highway Plus communication protocol overview 221 typical configuration 226 using the SLC 5/04 processors 221 wiring the SLC 5/04 processors 224 data packets 204 data table 273 Data Table Access Module (DTAM) monitoring with 41 mounting dimensions 79 DCD (Data Carrier Detect) 211 DCE (Data Communication Equipment) 210 DeviceNet interface 234, 265 DeviceNet network 233 1747-SDN module 233 1761-NET-DNI interface 234, 265 length 235 DeviceNet Scanner 233 DF1 full-duplex protocol 204 DF1 half-duplex protocol 205 DF1 protocol full-duplex 204 half-duplex 205 modem overview 210 overview 204 DF1 Radio Modem protocol channel 0 driver 207 SLC 5/03 processor feature 86 SLC 5/04 processor feature 89 SLC 5/05 processor feature 92 DH+ network devices that use the 1784-KTXD card 226 DH-485 Interface Converters 1747-PIC interface 40 1747-UIC interface 41 DH-485 network description 181 devices that use the 1746-BAS module 183
289
1747-KE module 183 1747-UIC interface 183 1770-KF3 module 183 example system configuration 187 grounding and terminating 196 initialization 182 installation 193 planning considerations 189 protocol 182 DH-485/RS-232 Interface Module user’s manual 203 DHCP configuring SLC 5/05 245 definition 272 DIN rail 273 discrete I/O modules 36 download 274 DSR (Data Set Ready) 210 DTAM Micro operator interface mounting dimensions 79 DTAM Plus operator interface monitoring with 41 mounting dimensions 79 DTE (Data Terminal Equipment) 210 DTE controlled answer 274 DTE, definition 274 DTR (Data Terminal Ready) 210 DTR dialing 274
E EEPROM 1 K User Words 42 4 K User Words 42 64 K User Words 44 EEPROM burning options 44 embedded responses 204 EMC Directive 97 emergency controller shutdown 66 Emergency-Stop Switches 67 EMI 275 enclosures environment 56 selecting 39 encoder definition 275 end device 204 Environmental Protection Agency (EPA) 135 equipment needed for installation 16 errors
Publication 1747-UM011G-EN-P - June 2008
Page 290
290
Index
SLC 5/01 and SLC 5/02 processors 144 SLC 5/03, SLC 5/04, SLC 5/05 processors 150 while downloading an operating system 159 Ethernet advanced functions 246 messaging 238 processor performance 238 using the SLC 5/05 processors 237 European Union Directives 28, 97 executing mode 275
F false 275 features SLC 5/01 processors 81 SLC 5/02 processor 83 SLC 5/03 processor 86 SLC 5/04 processors 89 SLC 5/05 processors 92 FIFO (First-In-First-Out) 275 file 275 full-duplex (point-to-point) 205 fuses, for power supply installation 139 troubleshooting tips 143
G getting started quickly overview 15 procedures 16 Required Tools and Equipment 16 ground bus 63 grounding guidelines ground bus 61 overview 61 special considerations for DC applications using 1746-P3 64
H half-duplex master protocol, A-B products that support 205 hard disk 276 hazardous environment component installation 57 selecting hardware components 47 heat dissipation, calculating for SLC 500 control system 261 Publication 1747-UM011G-EN-P - June 2008 heat, preventing excessive 60 high byte 276 housekeeping 276 humidity, processor specification 176
I I/O devices, recommendations for wiring wires, bundle 115 I/O modules discrete 36 specialty 36 wiring 116 IBM AT connector pin assignment 214 input modules installing 102 maximum current 227 troubleshooting 163 watts 263 wiring 116 input scan 276 input states on power down 70 installation chassis 17, 98 chassis interconnect cables 108 getting started quickly 15 inspecting 122 lithium battery on SLC 5/01 or SLC 5/02 processors 136 lithium battery on SLC 5/03, SLC 5/04, and SLC 5/05 processors 137 memory modules 103 modules 102 power supplies 104 processors 101 typical SLC system 55 instruction 277 instruction set definition 277 interconnect cable installation 108 interface converter, 1747-PIC 40 isolated link coupler, 1747-AIC dimensions 78 installing 193 isolation transformers example calculation 46 power considerations 68 selecting 46
J jumpers