The text of a manual · part 30 of 30
SLC 500 Modular Hardware Style User Manual, pages 291 to 296
Pages 291 to 296 of 296
The original document is the PDF (3.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 1747-L524
Page 291
Index
J1 103 J4 159 power supply 105
K keyswitch clearing faults for the SLC 5/03, SLC 5/04, and SLC 5/05 processors 149 keyswitch location SLC 5/03 processors 87 SLC 5/04 processors 90 SLC 5/05 processors 93 keyswitch positions for the SLC 5/03, SLC 5/04, and SLC 5/05 processors PROG 95 REM 96 RUN 95
L ladder logic 277 least significant bit (LSB) 277 LIFO (Last-In-First-Out) 277 line voltage variations, excessive 47 link coupler mounting dimensions 78 lithium batteries Code of Federal Regulations, 49 CFR 173.22a 134 disposal 135 DOT-E7052 provision 134 installing on SLC 5/01 or SLC 5/02 processors 136 installing on SLC 5/03, SLC 5/04, and SLC 5/05 processors 137 shipping when depleted 134 storing and handling 133 transportation 134 local I/O capacity, processor specification 176 logic 278 low byte 278
M machine motion, preventing 122 maintenance, preventive 73 master control relay (MCR) definition 278 using 66
291 master devices, DF1 half-duplex protocol 205 memory backup options, processor specification 176 memory modules for SLC 5/01 and 5/02 processors 42 for SLC 5/03, SLC 5/04, and SLC 5/05 processors 43 installation 103 mnemonic 278 modem definition 278 modems for RS232 210 modes 278 modules, installation 102 motor starters (bulletin 509) surge suppressors 49 motor starters (bulletin 709) surge suppressors 49 mounting chassis 98 mounting dimensions 10-slot chassis 76 13-slot chassis 77 4-slot chassis 75 7-slot chassis 76 AIC+ Advanced Interface Converter 80 Data Table Access Module 79 DeviceNet interface 80 DTAM Micro 79 DTAM Plus 79 Ethernet interface 80 link coupler 78 MSG instruction 204
N National Fire Protection Association (NFPA) 55 negative logic 279 noise generators 47 noise immunity, processor specification 176 noise, excessive 47 normally closed 279 normally open 279
O offline 280 offset 280 Publication 1747-UM011G-EN-P - June 2008
Page 292
292
Index off-state leakage current 280 one shot 280 online 280 operator interface selecting DTAM 41 DTAM Plus 41 PanelView 550 41 personal computer 40 output contact protection, selecting 50 output modules installing 102 maximum current 228 troubleshooting 165 watts 264 wiring 116 output scan 281 overview of the modular control system 29
P PanelView 550 Operator Terminal monitoring with 41 PC connector pin assignment 213 PCCC definition 281 performance Ethernet processor 238 personal computer, programming with 40 pinout, channel 0 202 planning considerations for a network 189 power considerations common power source 68 input states on power down 70 line conditions, other types of 70 loss of power source 70 undervoltage operation 70 power source, loss of 69 power supplies installing 18, 104 setting jumpers 105 power supply fuse replacing 139 power supply loading worksheet 38, 230 power, removing 142 preparing your wiring layout 114 preventing excessive heat 60 preventive maintenance 73 processor
Publication 1747-UM011G-EN-P - June 2008 installation 21, 101 processor files 281 processor hardware features SLC 5/01 81 SLC 5/02 83 SLC 5/03 86 SLC 5/04 89 SLC 5/05 92, 93 processor specifications ambient temperature rating 176 humidity 176 LED indicators 176 local I/O capacity 176 maximum chassis/slots 176 memory back-up options 176 noise immunity 176 program memory 176 program scan holdup time after loss of power 176 remote I/O capacity 176 standard RAM 176 PROG, keyswitch position for the SLC 5/03 and SLC 5/04 processors 95, 173 program alteration 143 program file definition 281 program memory, processor specification 176 program mode 281 program scan definition 281 program scan hold-up time after loss of power 176 programmable controller grounding and wiring guidelines 63 programming device 282 pulses transient 51
Q quick start for experienced users 15
R RAM, power back-up SLC 5/01 or SLC 5/02 processors 136 SLC 5/03, SLC 5/04, and SLC 5/05 processors 137 RAM, processor specification 176 RC network 50
Page 293
Index read 282 related documentation 14 relay 282 relay logic 282 relays, surge suppressors for 49 REM, keyswitch position for the SLC 5/03, SLC 5/04, and SLC 5/05 processors 96 remote I/O capacity, processor specification 176 remote I/O network 231 remote I/O passthru 232 removable terminal blocks (RTB) 119 installing 120 removing 119 using 119 removing power from the SLC 500 control system 142 replacement hardware cables and connectors 169 other items 171 terminal blocks 171 replacing a fuse on the power supply 139 required tools and equipment 16 reserved bit 282 restore 282 retainer clips replacement kit 172 replacing on modules 138 retentive data 282 RS-232 communication connectors 211 DCE pinout 212 DF1 protocol 204 DTE pinout 211 SLC 500 devices that support 203 RS-232 connector pin assignments 1746-BAS module to a modem 217 to DTE 217 1747-KE module to a modem 216 to DTE 216 2760-RB module to a modem 218 to DTE 218 IBM AT to an SLC 5/03 processor 214 PC to a modem 213 PLC-5 processor to a modem 219 to DTE 219 SLC 5/03 processor
293 to a modem 214 to a PC (with cable 1747-CP3) 215 to DTE 215 RS-232 devices 1746-BAS module 203 1747-KE module 203 RS-232, definition 282 RTB 119 RTS (Request to Send) 210 run mode 283 RUN, keyswitch position for SLC 5/03, SLC 5/04, and SLC 5/05 processors 95 rung 283
S safety considerations disconnecting main power 72 master control relay circuits, periodic tests of 72 power distribution 72 safety circuits 72 save 283 SCADA applications 201 scan 283 scan time 283 selecting contact protection 50 discrete I/O modules 36 enclosures 40 isolation transformers 46 memory modules for SLC 5/03, SLC 5/04, and SLC 5/05 processors 43 power supply 36 processors 31 SLC 5/01 and SLC 5/02 memory modules 42 speciality I/O modules 36 surge suppressors 48 sinking 111, 283 sinking and sourcing 111 contact output circuits 112 sinking device with sourcing input module circuit 113 sinking device with sourcing output module circuit 113 solidstate DC I/O circuits 112 sourcing device with sinking input module 112 sourcing device with sinking output module circuit 113 Publication 1747-UM011G-EN-P - June 2008
Page 294
294
Index slave devices, DF1 half-duplex protocol 205 SLC 500 programmable controllers general specifications 176 installing 101 selecting a memory module 42, 43 selecting a processor 31 selecting discrete I/O modules 36 selecting enclosures 40 selecting isloation transformers 46 selecting speciality I/O modules 36 special considerations 47 troubleshooting 141 SLC processor compatible cables 16 SLC processor compatible interfaces 16 sourcing 284 spacing your controllers 58 specialty I/O modules 36 specifications processors ambient temperature rating 176 clock/calendar accuracy 176 humidity 176 LED indicators 176 local I/O capacity 176 maximum chassis/slots 176 memory back-up options 176 noise immunity 176 program memory 176 program scan hold-up time after loss of power 176 remote I/O capacity 176 standard RAM 176 starting up your control system 121 disconnect motion-causing devices 122 enter and test your program 129 inspect your installation 122 test your inputs 125 test your outputs 126 start-up instructions 15 status 284 surge suppression circuits 50 surge suppressors for motor starters 49 for relays 49 system configuration, example 187 system test general specifications 175
Publication 1747-UM011G-EN-P - June 2008
T terminal 284 testing inputs 125 outputs 126 program 129 throughput 284 tools needed for installation 16 transistor output transient pulses 51 troubleshooting input modules 163 output modules 165 SLC 5/01 processor 143 SLC 5/02 processors 143 SLC 5/03 processor 149 SLC 5/03 processors errors while downloading an operating system 159 SLC 5/04 processors 149 SLC 5/05 processors 149 troubleshooting, tips for program alteration 143 removing power 142 replacing fuses 143 true 284
U Universal Serial Bus see 1747-UIC interface upload 285 USB see 1747-UIC interface using memory modules (EEPROM and UVPROM) EEPROM burning options 44
V varistor 50
W wire types Belden #9463 224 wire/terminal connections, for Belden #9842 cable 170, 195 wiring I/O modules 116 wiring layout, preparing your 114
Page 295
Page 296
Rockwell Automation Support
Rockwell Automation provides technical information on the Web to assist you in using its products. At http://support.rockwellautomation.com, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnect Support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://support.rockwellautomation.com.
Installation Assistance If you experience a problem with a hardware module within the first 24 hours of installation, please review the information that's contained in this manual. You can also contact a special Customer Support number for initial help in getting your module up and running. United States
1.440.646.3434 Monday – Friday, 8am – 5pm EST
Outside United States
Please contact your local Rockwell Automation representative for any technical support issues.
New Product Satisfaction Return Rockwell tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning, it may need to be returned. United States
Contact your distributor. You must provide a Customer Support case number (see phone number above to obtain one) to your distributor in order to complete the return process.
Outside United States
Please contact your local Rockwell Automation representative for return procedure.
SLC 5/03, SLC, SLC 500, MicroLogix, PanelBuilder, Data Highway Plus, PanelView 300, PanelView 550, PanelView 1000, PanelView 300 Micro, PanelView 1400, DH+, MicroLogix, CompactLogix, FlexLogix, ControlLogix, DTAM, PLC-5, PLC-2, PLC-3, RSLogix 500, RSLogix 5000, RSLinx, WINtelligent, Allen-Bradley, TechConnect, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.
Publication 1747-UM011G-EN-P - June 2008 296 Supersedes Publication 1747-UM011F-EN-P - May 2007
Copyright © 2008 Rockwell Automation, Inc. All rights reserved.