For the Allen-Bradley 1756-ENET

Page 105

Appendix

C

Configuring the RSLinx Ethernet Communication Driver

What This Appendix Contains

In order to communicate with your 1756-ENET/B modules over your network you must configure the RSLinx Ethernet communication driver (AB_ETH). You can configure the AB_ETH driver with the IP addresses of all the Ethernet modules on your system. You will need this driver to download the example application programs in this manual. The following table lists the contents of this appendix and where to find specific information: For information about

Installing the RSLinx Software

See page

Installing the RSLinx Software

C-1

Configuring the AB_ETH Driver

C-2

Use the following procedure to install RSLinx software on your computer. 1. Insert the CD in the CD-ROM drive. Note: The CD-ROM supports Windows Autorun. Once inserted into the CD-ROM drive, if you have Autorun configured, the installation will automatically start at the first setup screen. If Autorun is not configured for your CD-ROM drive, go to step 2. 2. From the Start menu, choose Run. You will see the Run pop-up window. 3. Type d:/setup (if it doesn’t appear automatically), where d: is your CD-ROM driver letter. 4. Click on OK. You will see the progress bar, followed by the welcome screen.

1

Publication 1756-UM051B-EN-P - November 2000

Page 106

C-2

Configuring the RSLinx Ethernet Communication Driver

Configuring the AB_ETH Driver

To configure the AB-ETH Ethernet communication driver perform the following steps: 1. Start RSLinx.

2. From the Communications menu, select Configure Drivers. The following window will open.

3. Click on the arrow to the right of the Available Driver Types box. The Available Driver Types list will appear.

Publication 1756-UM051B-EN-P - November 2000

Page 107

Configuring the RSLinx Ethernet Communication Driver

C-3

4. Select Ethernet Devices and click on Add/New. You will be prompted to name the driver.

5. Select the default driver name (e.g., AB_ETH-1) or type in your own name and click on OK. The Configure driver window will appear with the Station Mapping page open.

6. Click on Add New and enter the IP address of your 1756-ENET/B module (e.g., 130.130.130.2).

Publication 1756-UM051B-EN-P - November 2000

Page 108

C-4

Configuring the RSLinx Ethernet Communication Driver

7. Repeat step 6 for each additional Ethernet module you need to access.

8. When you are done entering the IP addresses, click on Apply. 9. Click on OK to close the Configure driver window. The new driver will appear in the list of configured drivers. (Your list will display the drivers you have configured on your workstation.)

10.Close RSLinx