Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of ControlLogix Ethernet Communication Interface Module 1756-ENET/B User Manual

Manual · Allen-Bradley

ControlLogix Ethernet Communication Interface Module 1756-ENET/B User Manual

Manual122 pagesPDF 1.5 MB

User manual for the Allen-Bradley 1756-ENET/B ControlLogix Ethernet communication interface module: install, configure, examples.

Download the PDF1.5 MB

Covers · 1 model

The models it covers

Summary

What is in it

The Allen-Bradley user manual for the 1756-ENET/B ControlLogix Ethernet Communication Interface Module. It describes the module and the Ethernet protocols it uses, how to install it in a ControlLogix chassis and set its IP address with BootP, RSLinx or DHCP, and works through three example applications: rack optimized I/O, analog I/O with a direct connection, and produced and consumed tags between controllers. Appendices cover the LED status indicators, the module's diagnostic web pages, the RSLinx driver, gateway use and electronic keying.

Its parts

  1. About the 1756-ENET/B Module
  2. Installing the Ethernet Module
  3. Before You Configure Your Module
  4. Configuring the Ethernet Module
  5. Rack Optimized I/O
  6. Analog I/O with Direct Connection
  7. Produced and Consumed Tags

From the manual

Key facts from this manual

Each line names its page in the PDF.

User manual (publication 1756-UM051B-EN-P, November 2000) for the Allen-Bradley ControlLogix 1756-ENET/B Ethernet communication interface module. It covers installing and wiring the module, setting its IP address, rack optimized and direct I/O connections, produced and consumed tags, and diagnosis by the status lights and the module's built-in web pages.

Read for this summary: pages 1 to 4, 9 to 10, 19 to 23, 25 to 37, 97, 99 to 103, 109 and 119 of 122.

What it is
ControlLogix Ethernet module that serves as an I/O adapter or as a scanner, and carries explicit messages p. 20
Ethernet connectors
AUI and 10Base-T (RJ45) p. 19, 30
Protocols
Ethernet/IP (CIP); TCP for explicit messages, UDP for real-time I/O p. 33, 34
Compatibility
Module firmware 2.01 or higher; Logix 5550 controller 6.10 or higher; RSLogix 5000 7.0 or higher; RSLinx 2.2 or higher p. 20
I/O connections
Rack optimized (discrete digital I/O only) and direct connections; analog I/O needs direct p. 20, 21
Chassis slot
Any ControlLogix slot; modules per chassis limited only by chassis size p. 19, 27
Removal under power
Designed to be inserted or removed with chassis power applied p. 26
IP setup
IP address, gateway and subnet mask set with the Rockwell BootP utility, RSLinx, generic BootP software or DHCP (with limits) p. 35
AUI cables
1756-TC02 (2 meters) and 1756-TC15 (15 meters), for use with the module door closed p. 30
Status lights
OK, TXD and RXD indicators on the faceplate p. 97
Web diagnostics
Built-in web pages: module information, TCP/IP configuration, diagnostics, Chassis Who p. 99
Network management
SNMP agent at the MIB II level p. 34
Gateway use
Bridges Ethernet to ControlNet, DeviceNet and Data Highway Plus in a ControlLogix gateway p. 109

What this manual walks you through

  • Installing the module in a ControlLogix chassis p. 26, 27, 28
  • Wiring the AUI or RJ45 Ethernet connector p. 30
  • Setting the IP address, gateway and subnet mask p. 35, 36, 37
  • Choosing rack optimized or direct I/O connections p. 20, 21
  • Setting the requested packet interval (RPI) p. 23
  • Example applications: rack optimized I/O, analog I/O by direct connection, produced and consumed tags p. 9
  • Reading the OK, TXD and RXD status lights p. 97
  • Using the module's web pages for diagnostics p. 99
  • Using the module in a ControlLogix gateway p. 109

Good to know

  • Inserting or removing the module under power, or plugging the Ethernet cable under power, can cause an arc; remove power or make sure the area is nonhazardous first. p. 26, 30
  • A replacement module must go in the same slot to resume identical operation. p. 29
  • Rack optimized connections carry I/O data and status only, not diagnostics. p. 21
  • An Ethernet switch instead of a hub reduces collisions and lost packets. p. 31

Questions this manual answers

What does a flashing red OK light on a 1756-ENET/B mean?

The module is not configured. Configure the module. p. 97

How do I set the IP address on a 1756-ENET/B?

Use the Rockwell BootP utility that ships with the module, RSLinx, generic BootP software, or within some limits a DHCP server. p. 35

Can analog I/O use a rack optimized connection through a 1756-ENET/B?

No. Rack optimized connections are only for discrete digital I/O; analog I/O requires direct connections. p. 21

What firmware and software does the 1756-ENET/B need?

Module firmware 2.01 or higher, a Logix 5550 controller at 6.10 or higher, RSLogix 5000 7.0 or higher and RSLinx 2.2 or higher. p. 20

How do I see network diagnostics on a 1756-ENET/B?

Enter the module's IP address in a web browser to open its diagnostic web pages. p. 99

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1756-UM051B-EN-P, ControlLogix Ethernet Communication Interface Module User Manual1
  2. Important User Information2
  3. European Communities (EC) Directive Compliance4
  4. Rockwell Automation Support5
  5. Preface - About This User Manual7
    1. What this Preface Contains7
    2. Who Should Use This Manual7
    3. Common Techniques Used in This Manual8
    4. How To Use This Manual8
    5. Where to Find More Information11
    6. Terminology12
  6. 1 - About the 1756-ENET/B Module19
    1. What This Chapter Contains19
    2. Module Features19
    3. Hardware/Software Compatibility20
    4. What the Module Does20
    5. Support of Rack Optimized and Direct Connections20
    6. Use of the Control and Information Protocol (CIP)22
    7. Understanding the Producer/Consumer Model22
    8. Specifying the Requested Packet Interval (RPI)23
    9. What’s Next?23
  7. 2 - Installing the Ethernet Module25
    1. What This Chapter Contains25
    2. Identifying Module Features25
    3. Insertion and Removal Under Power26
    4. Installing the Ethernet Module26
    5. What’s Next?32
  8. 3 - Before You Configure Your Module33
    1. What This Chapter Contains33
    2. Ethernet Protocols33
    3. Configuration Requirements35
    4. For More Information38
    5. What’s Next?38
  9. 4 - Configuring the Ethernet Module39
    1. What This Chapter Contains39
    2. Using the Rockwell BootP Utility39
    3. Using RSLinx Software40
    4. Using a BootP Server43
    5. Using DHCP Software to Configure Your Module45
40 more lines, from page 45 on
  1. What’s Next?45
  2. 5 - Rack Optimized I/O47
    1. About the Example Application47
    2. Set Up the Hardware48
    3. Create the Example Application49
    4. Test the Example Application62
    5. What’s Next?63
  3. 6 - Analog I/O with Direct Connection65
    1. About the Example Application65
    2. Set Up the Hardware66
    3. Create the Example Application67
    4. Test the Example Application76
    5. What’s Next?76
  4. 7 - Produced and Consumed Tags77
    1. About the Example Application77
    2. Set Up the Hardware78
    3. Create the Producer Application79
    4. Create the Consumer Application84
    5. Test the Messaging95
    6. What’s Next?95
  5. A - LED Status Indicators97
    1. Interpreting the Status Indicators97
  6. B - 1756-ENET/B Module Web Pages99
    1. Web Page Diagnostics99
  7. C - Configuring the RSLinx Ethernet Communication Driver105
    1. What This Appendix Contains105
    2. Installing the RSLinx Software105
    3. Configuring the AB_ETH Driver106
  8. D - 1756-ENET/B Support of ControlLogix Gateway Communication109
    1. Using the 1756-ENET/B Module in a ControlLogix Gateway109
  9. E - Example Network Configurations111
    1. What This Appendix Contains111
    2. Small System Example112
    3. Expanded System with FLEX I/O113
    4. Larger Control Networks114
  10. F - Electronic Keying115
    1. Specifying Electronic Keying115
  11. Index117
  12. Publication Problem Report119
  13. Back Cover122

From the PDF’s own bookmarks.

The whole text · 18 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 31-3
  2. Pages 4 to 64-6
  3. Preface - About This User Manual7-14
  4. Table of Contents15-18
  5. 1 - About the 1756-ENET/B Module19-24
  6. 2 - Installing the Ethernet Module25-32
  7. 3 - Before You Configure Your Module33-38
  8. 4 - Configuring the Ethernet Module39-46
  9. 5 - Rack Optimized I/O, pages 47 to 5547-55
  10. 5 - Rack Optimized I/O, pages 56 to 6456-64
  11. 6 - Analog I/O with Direct Connection65-76
  12. 7 - Produced and Consumed Tags, pages 77 to 8677-86
  13. 7 - Produced and Consumed Tags, pages 87 to 9687-96
  14. Pages 97 to 10497-104
  15. C - Configuring the RSLinx Ethernet Communication Driver105-108
  16. Pages 109 to 114109-114
  17. Pages 115 to 118115-118
  18. Pages 119 to 122119-122

The file

Revision and size

Part no.1756-UM051B-EN-P
RevisionNovember 2000
PublisherRockwell Automation
Pages122
PDF1.5 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.
1756-UM051B-EN-P

The first pages · 3 of 122

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 122
Page 2
Page 2of 122
Page 3
Page 3of 122

More documents · 1

For the same models