Page 161

Axis properties

Appendix A

•

Configure Position Error Tolerance and Position Lock Tolerance.

Edit the parameters on this tab: •

Type parameter changes. Select OK to save the edits.

•

Select Manual Adjust to open the Manual Adjust dialog box associated with this tab. Use the spin controls to edit parameter settings. The changes are saved the moment a spin control changes any parameter value.

When the controller is online and set to Hard Run mode, or a Feedback On condition exists, the parameters on this tab are read-only When Logix Designer application is offline, edit these parameters and save the program. Use the Save command or select Apply. Re-download the edited program to the controller before running. Parameter

Description

Hard Travel Limit

Enables a periodic test that monitors the current state of the positive and negative overtravel limit switch inputs, when Positioning Mode is set to Linear (in the Conversion tab of this dialog box). If an axis is configured for hardware overtravel checking and if that axis passes beyond a positive or negative overtravel limit switch, a Positive Hard Overtravel Fault or Negative Hard Overtravel Fault is issued. The response to this fault is specified by the Hard Overtravel setting (in the Fault Actions tab of this dialog box).

Soft Travel Limit

Enables software overtravel checking for an axis when Positioning Mode is set to Linear (in the Conversion tab of this dialog box). If an axis is configured for software overtravel limits and if that axis passes beyond these maximum travel limits (positive or negative), a software overtravel fault is issued. The response to this fault is specified by the Soft Overtravel setting (in the Fault Actions tab of this dialog box). Software overtravel limits are disabled during the tuning process.

Maximum Positive

Type the maximum positive position used for software overtravel checking, in position units. The Maximum Positive limit must be greater than the Maximum Negative limit.

Maximum Negative

Type the maximum negative position to be used for software overtravel checking, in position units. The Maximum Negative limit must be less than the Maximum Positive limit.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

161

Page 162

Appendix A

Axis properties

Parameter

Description

Position Error Tolerance

Specifies how much position error the servo tolerates before issuing a position error fault. This value is interpreted as a +/quantity. For example, setting Position Error Tolerance to 0.75 position units means that a position error fault is generated whenever the position error of the axis is greater than 0.75 or less than -0.75 position units. This value is set to twice the following error at maximum speed based on the measured response of the axis, during the autotuning process. In most applications, this value provides reasonable protection in case of an axis fault or stall condition without nuisance faults during normal operation. If it is necessary to change the calculated position error tolerance value, the recommended setting is 150% to 200% of the position error while the axis is running at its maximum speed.

Position Lock Tolerance

Specifies the maximum position error the servo module accepts to indicate the Position Lock status bit is set. Useful to determe when the desired end position is reached for position moves. This value is interpreted as a +/- quantity. For example, specifying a lock tolerance of 0.01 provides a minimum positioning accuracy of +/- 0.01 position units.

Peak Torque/Force Limit

Specifies the maximum percentage of the motors rated current that the drive can command as positive or negative torque/force. For example, a torque limit of 150% limits the current delivered to the motor to 1.5 times the continuous current rating of the motor.

Continuous Torque/Force Limit

Specifies the maximum percentage of the motors rated current that the drive can command on a continuous or RMS basis. For example, a Continuous Torque/Force Limit of 150% limits the continuous current delivered to the motor to 1.5 times the continuous current rating of the motor.

Manual Adjust

Opens the Manual Adjust dialog box to edit parameter settings.

Set Custom Limits

Opens the Custom Limit Attributes dialog box.

Manual Adjust for Limits tab

Use the Limits tab of the Manual Adjust dialog box for online editing of the Position Error Tolerance, Position Lock Tolerance, Peak Torque/Force Limit, and Continuous Torque/Force Limit parameters.

Manual Adjust is unavailable when Logix Designer application is in Wizard mode, and when offline edits to the parameters were not saved or applied.

162

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 163

Axis properties

Set custom limits

Appendix A

Use the Custom Limit Attributes dialog box to monitor and edit the limitrelated attributes.

When Logix Designer application is online, the parameters on this tab transition to a read-only state. When a parameter transitions to a read-only state, any pending changes to parameter values are lost, and the parameter reverts to the most recently saved parameter value. When multiple workstations connect to the same controller using Logix Designer application and invoke the Axis Wizard or Axis Properties dialog box, the firmware allows only the first workstation to make any changes to axis attributes. The second workstation switches to a Read Only mode, which is indicated in the title bar. View the changes from that workstation. Attribute

Description

VelocityLimitBipolar

This attribute sets the velocity limit symmetrically in both directions. If the command velocity exceeds this value, VelocityLimitStatusBit of the DriveStatus attribute is set. This attribute has a value range of 0 to 2.14748x1012.

AccelerationLimitBipolar

This attribute sets the acceleration and deceleration limits for the drive. If the command acceleration exceeds this value, AccelLimitStatusBit of the DriveStatus attribute is set. This attribute has a value range of 0 to 2.14748x1015.

TorqueLimitBipolar

This attribute sets the torque limit symmetrically in both directions. When actual torque exceeds this value, TorqueLimitStatus of the DriveStatus attribute is set. This attribute has a value range of 0 to 1000.

VelocityLimitPositive

This attribute displays the maximum allowable velocity in the positive direction. If the velocity limit is exceeded, bit 5 (‘Velocity Command Above Velocity Limit’) VelocityLimitStatusBit of the DriveStatus attribute is set. This attribute has a value range of 0 to 2.14748x1012.

VelocityLimitNegative

This attribute displays the maximum allowable velocity in the negative direction. If the velocity limit is exceeded, bit 5 (‘Velocity Command Above Velocity Limit’) VelocityLimitStatusBit of the DriveStatus attribute is set. This attribute has a value range of 2.14748x1012 to 0.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

163

Page 164

Appendix A

Axis properties

Offset tab - AXIS_SERVO

164

Attribute

Description

VelocityThreshold

This attribute displays the velocity threshold limit. If the motor velocity is less than this limit, VelocityThresholdStatus of the DriveStatus attribute is set. This attribute has a value range of 0 to 2.14748x1012.

VelocityWindow

This attribute displays the limits of the velocity window. If the motor’s actual velocity differs from the command velocity by an amount less that this limit, VelocityLockStatus of the DriveStatus attribute is set. This attribute has a value range of 0 to 2.14748x1012.

VelocityStandstillWindow

This attribute displays the velocity limit for the standstill window. If the motor velocity is less than this limit VelocityStandStillStatus of the DriveStatus bit is set. This attribute has a value range of 0 to 2.14748x1012.

AccelerationLimitPositive

This attribute limits the maximum acceleration ability of the drive to the programmed value. If the command acceleration exceeds this value, AccelLimitStatusBit of the DriveStatus attribute is set. This attribute has a value range of 0 to 2.14748x1015.

AccelerationLimitNegative

This attribute limits the maximum acceleration ability of the drive to the programmed value. If the command acceleration exceeds this value, the AccelLimitStatus bit of the DriveStatus attribute is set. This attribute has a value range of -2.14748x1015 to 0.

TorqueLimitPositive

This attribute displays the maximum torque in the positive direction. If the torque limit is exceeded, the TorqueLimitStatus bit of the DriveStatus attribute is set. This attribute has a value range of 0 to 1000.

TorqueLimitNegative

This attribute displays the maximum torque in the negative direction. If the torque limit is exceeded, the TorqueLimitStatus bit of the DriveStatus attribute is set. This attribute has a value range of -1000 to 0.

TorqueThreshold

This attribute displays the torque threshold. If this limit is exceeded, the TorqueThreshold bit of the DriveStatus attribute is set. This attribute has a value range of 0 to 1000.

Use the Offset tab to make offline adjustments to these Servo Output values for an axis of the type AXIS_SERVO, configured as a Servo drive in the General tab of this dialog box. •

Backlash Compensation

•

Velocity Offset

•

Torque Offset

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 165

Axis properties

Appendix A

•

Output Offset

Edit the parameters on this tab: •

Type the parameter changes. Select OK to save the edits.

•

Select Manual Adjust to open the Manual Adjust dialog box associated with this tab. Use the spin controls to edit parameter settings. Changes are saved the moment a spin control changes any parameter value.

When the controller is online and set to Hard Run mode, or a Feedback On condition exists, the parameters on this tab become read-only When Logix Designer application is offline, edit these parameters and save the program. Use the Save command or select Apply. Re-download the edited program to the controller before running. Parameter

Description

Friction/Deadband Compensation and Backlash Compensation

The percentage of output level added to a positive current Servo Output value, or subtracted from a negative current Servo Output value, to move an axis that is stuck in place due to static friction. It is not unusual for an axis to have enough static friction (called ‘sticktion’) that, even with a significant position error, the axis refuses to budge. Backlash Compensation is used to break ‘sticktion’ in the presence of a nonzero position error. This is done by adding, or subtracting, a percentage output level), called Backlash Compensation to the Servo Output value. The Backlash Compensation value should be just less than the value that breaks the ‘sticktion’. A larger value can cause the axis to ‘dither’, that is, move rapidly back and forth about the commanded position. This controller attribute is replicated in the motion module.

Backlash Compensation Window

To address the issue of dither when applying Backlash Compensation and hunting from the integral gain, a Backlash Compensation Window is applied around the current command position when the axis is not being commanded to move. If the actual position is within the Backlash Compensation Window, the Backlash Compensation value is applied to the Servo Output, but scaled by the ratio of the position error to the Backlash Compensation Window. Within the window, the servo integrators are also disabled. Thus, once the position error reaches or exceeds the value of the Backlash Compensation Window attribute, the full Backlash Compensation value is applied. If the Backlash Compensation Window is set to zero, this feature is effectively disabled. A nonzero Backlash Compensation Window has the effect of softening the Backlash Compensation because it is applied to the Servo Output and reduces the dithering effect it creates. This generally allows applying higher values of Backlash Compensation. Hunting is also eliminated at the cost of a small steady-state error. Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

165

Page 166

Appendix A

Axis properties

Parameter

Description

Backlash Compensation and Backlash Reversal Offset

Backlash Reversal Offset provides the capability to compensate for positional inaccuracy introduced by mechanical backlash. For example, power-train type applications require a high level of accuracy and repeatability during machining operations. Axis motion is often generated by a number of mechanical components, a motor, a gearbox, and a ball-screw that may introduce inaccuracies and that are subject to wear over their lifetime. Therefore, when an axis is commanded to reverse direction, mechanical play in the machine (through the gearing, ball-screw, and so on) may result in a small amount of motor motion without axis motion. As a result, the feedback device may indicate movement even though the axis has not physically moved. If a value of zero is applied to the Backlash Reversal Offset, the feature is effectively disabled. When it is enabled by a nonzero value, and the load is engaged by a reversal of the commanded motion, changing the Backlash Reversal Offset can cause the axis to shift as the offset correction is applied to the command position.

Stabilization Window

The Backlash Stabilization Window controls the Backlash Stabilization feature in the servo control loop. Configuring a suitable value for the Backlash Stabilization Window eliminates gearbox buzz without sacrificing any servo performance. In general, this value should be set to the measured backlash distance. A Backlash Stabilization Window value of zero effectively disables the feature.

Velocity Offset

Provides a dynamic velocity correction to the output of the position servo loop, in position units per second.

Torque Offset

Provides a dynamic torque command correction to the output of the velocity servo loop, as a percentage of velocity servo loop output.

Output Offset

Corrects the problem of axis ‘drift’ by adding a fixed voltage value (not to exceed ±10 Volts) to the Servo Output value. Enter a value to achieve near zero drive velocity when the uncompensated Servo Output value is zero. When interfacing an external drive, compensate for the effect of drive offset. This is especially true for a velocity drive. Cumulative offsets of the servo module’s DAC output and the Servo Drive Input result in a situation where a zero commanded Servo Output value causes the axis to ‘drift’. If the drift is excessive, problems with the Hookup Diagnostic and Tuning procedures may occur, and can result in a steady-state nonzero position error when the servo loop is closed.

Manual Adjust

Opens the Manual Adjust dialog box.

Manual Adjust for Offset tab

Use the Offset tab of the Manual Adjust dialog box for online editing of the Friction/Deadband Compensation, Backlash Compensation, Velocity Offset, Torque Offset, and Output Offset parameters.

Manual Adjust is unavailable when Logix Designer application is in Wizard mode, and when offline edits to the parameters were not saved or applied.

166

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 167

Axis properties

Offset tab AXIS_SERVO_DRIVE

Appendix A

Use the Offset tab to make offline adjustments to these Servo Output values for an axis of the type AXIS_SERVO_DRIVE configured as a Servo drive in the General tab of this dialog box. •

Backlash Compensation

•

Velocity Offset

•

Torque/Force Offset

Edit the parameters on this tab: •

Type the parameter changes and select OK to save the edits

•

Select Manual Adjust to open the Manual Adjust dialog box associated with this tab. Use the spin controls to edit parameter settings. The changes are saved the moment a spin control changes any parameter value.

When the controller is online and set to Hard Run mode, or a Feedback On condition exists, the parameters on this tab are read-only. When Logix Designer application is offline, edit these parameters and save the program. Use the Save command or select Apply. Re-download the edited program to the controller before running. Parameter

Description

Backlash Compensation

The percentage of output level added to a positive current Servo Output value, or subtracted from a negative current Servo Output value, for the purpose of moving an axis that is stuck in place due to static friction. It is not unusual for an axis to have enough static friction – called 'sticktion' – that, even with a significant position error, the axis refuses to budge. Use Backlash Compensation to break 'sticktion' in the presence of a nonzero position error. Add or subtract a percentage output level, called Backlash Compensation, to the Servo Output value. The Backlash Compensation value should be just less than the value that breaks the ‘sticktion’. A larger value can cause the axis to ‘dither’, that is, move rapidly back and forth about the commanded position.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

167

Page 168

Appendix A

Axis properties

Parameter

Description

Backlash Compensation Window

To address the issue of dither when applying Backlash Compensation and hunting from the integral gain, a Backlash Compensation Window is applied around the current command position when the axis is not being commanded to move. If the actual position is within the Backlash Compensation Window, the Backlash Compensation value is applied to the Servo Output, but scaled by the ratio of the position error to the Backlash Compensation Window. Within the window, the servo integrators are also disabled. Thus, once the position error reaches or exceeds the value of the Backlash Compensation Window attribute, the full Backlash Compensation value is applied. If the Backlash Compensation Window is set to zero, this feature is effectively disabled. A nonzero Backlash Compensation Window has the effect of softening the Backlash Compensation as it is applied to the Servo Output and reducing the dithering effect that it creates. This generally allows higher values of Backlash Compensation to be applied. Hunting is also eliminated at the cost of a small steady-state error.

Backlash Compensation Reversal Offset

Backlash Reversal Offset provides the capability to compensate for positional inaccuracy introduced by mechanical backlash. For example, power-train type applications require a high level of accuracy and repeatability during machining operations. Axis motion is often generated by a number of mechanical components, a motor, a gearbox, and a ball-screw that may introduce inaccuracies and that are subject to wear over their lifetime. Therefore, when an axis is commanded to reverse direction, mechanical play in the machine (through the gearing, ball-screw, and so on) may result in a small amount of motor motion without axis motion. As a result, the feedback device may indicate movement even though the axis has not physically moved. If a value of zero is applied to the Backlash Reversal Offset, the feature is unavailable. When enabled by a nonzero value, and the load is engaged by a reversal of the commanded motion, changing the Backlash Reversal Offset can cause the axis to shift as the offset correction is applied to the command position.

Backlash Stabilization Window

The Backlash Stabilization Window controls the Backlash Stabilization feature in the servo control loop. Configuring a suitable value for the Backlash Stabilization Window eliminates gearbox buzz without sacrificing any servo performance. In general, this value should be set to the measured backlash distance. This feature is unavailable when a Backlash Stabilization Window value is zero.

Velocity Offset

Provides a dynamic velocity correction to the output of the position servo loop, in position units per second.

Torque/Force Offset

Provides a dynamic torque command correction to the output of the velocity servo loop, as a percentage of velocity servo loop output.

Manual Adjust

Opens the Manual Adjust dialog box to edit parameter settings.

Manual adjust for Offset tab

Use the Offset tab of the Manual Adjust dialog box for online editing of the Friction/Deadband Compensation, Backlash Compensation, Velocity Offset, Torque Offset, and Output Offset parameters.

Manual Adjust is unavailable when Logix Designer application is in Wizard mode, and when offline edits to the parameters were not saved or applied.

Fault Actions tab AXIS_SERVO 168

Use the Fault Actions tab to specify the actions that are taken in response to these faults:

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 169

Axis properties

Appendix A

•

Drive Fault

•

Feedback Noise Fault

•

Feedback Loss Fault

•

Position Error Fault

•

Soft Overtravel Fault

When a parameter transitions to a read-only state, any pending changes to parameter values are lost, and the parameter reverts to the most recently saved parameter value. When multiple workstations connect to the same controller using Logix Designer application and invoke the Axis Wizard or Axis Properties dialog box, the firmware allows only the first workstation to make any changes to axis attributes. The second workstation switches to a Read Only mode, indicated in the title bar. Changes can only be viewed from that workstation, not edited. Select one fault action for each fault type: •

Shutdown - If a fault action is set to Shutdown, when the associated fault occurs, axis servo action is unavailable, the servo amplifier output is zeroed, and the drive enable output is deactivated. Shutdown is the most severe action to a fault and usually reserved for faults that could endanger the machine or the operator if power is not removed as quickly and completely as possible.

•

Disable Drive - If a fault action is set to Disable Drive, when the associated fault occurs, axis servo action is unavailable, the servo amplifier output is zeroed, and the drive enable output is deactivated.

•

Stop Motion - If a fault action is set to Stop Motion, when the associated fault occurs, the axis immediately starts decelerating the axis command position to a stop at the configured Maximum Deceleration Rate without disabling servo action or the servo modules Drive Enable output. This is the gentlest stopping mechanism in response to a fault.Use this setting for less

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

169

Page 170

Appendix A

Axis properties severe faults. After the stop command fault action has stopped the axis, no further motion can be generated until the fault is first cleared. •

Status Only - If a fault action is set to Status Only, when the associated fault occurs, no action is taken. The application program must handle any motion faults. In general, only use this setting in applications where the standard fault actions are not appropriate. ATTENTION: Selecting the wrong fault action for the application can cause a dangerous condition resulting in unexpected motion, damage to the equipment, and physical injury or death. Keep clear of moving machinery.

Parameter

Description

Drive Fault

Specifies the fault action to take when a drive fault condition is detected, for an axis with the Drive Fault Input enabled (in the Servo tab of this dialog box) that is configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.

Feedback Noise

Specifies the fault action to take when excessive feedback noise is detected. The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.

Feedback Loss

Specifies the fault action to take when feedback loss condition is detected. The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.

Position Error

Specifies the fault action to take when position error exceeds the position tolerance set for the axis, for an axis configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.

Soft Overtravel

Specifies the fault action to take when a software overtravel error occurs, for an axis with Soft Travel Limits enabled and configured (in the Limits tab of this dialog box) that is configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.

Fault Actions tab AXIS_SERVO_DRIVE

170

Use the Fault Actions tab to specify the actions to take in response to these faults for an axis of the type AXIS_SERVO_DRIVE: •

Drive Enable Input

•

Drive Thermal Fault

•

Motor Thermal Fault

•

Feedback Noise Fault

•

Feedback Fault

•

Position Error Fault

•

Hard Overtravel Fault

•

Soft Overtravel Fault

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018