Page 171
Axis properties
Appendix A
•
Phase Loss
When a parameter transitions to a read-only state, any pending changes to parameter values are lost, and the parameter reverts to the most recently saved parameter value. When multiple workstations connect to the same controller using the Logix Designer application and invoke the Axis Wizard or Axis Properties dialog box, the firmware allows only the first workstation to make any changes to axis attributes. The second workstation switches to a Read Only mode, indicated in the title bar, so the changes can only be viewed from that workstation, but not edited. Select one fault action for each fault type. •
Shutdown - If a fault action is set to Shutdown, when the associated fault occurs, axis servo action is immediately disabled, the servo amplifier output is zeroed, and the drive enable output is deactivated. Shutdown is the most severe action to a fault and usually reserved for faults that could endanger the machine or the operator if power is not removed as quickly and completely as possible.
•
Disable Drive - If a fault action is set to Disable Drive, when the associated fault occurs, it brings the axis to a stop by applying the Stopping Torque for up to the Stopping Time Limit. During this period, the servo is active but no longer tracking the command reference from Logix Designer. Once the axis is stopped (or the stopping limit is exceeded), the servo and power structure are disabled.
•
Stop Motion - If a fault action is set to Stop Motion, when the associated fault occurs, the axis immediately starts decelerating the axis command position to a stop at the configured Maximum Deceleration Rate without disabling servo action or the servo modules Drive Enable output. The gentlest stopping mechanism in response to a fault. Used for less severe
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
171
Page 172
Appendix A
Axis properties faults. After the stop command fault action has stopped the axis, no further motion can be generated until the fault is first cleared. •
Status Only - If a fault action is set to Status Only, when the associated fault occurs, no action is taken. The application program must handle any motion faults. In general, this setting should only be used in applications where the standard fault actions are not appropriate. ATTENTION: Selecting the wrong fault action for the application can cause a dangerous condition. Keep clear of moving machinery.
Parameter
Description
Drive Enable Input
Specifies the fault action to be taken when a Drive Enable Input Fault is detected, for an axis configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.
Drive Thermal
Specifies the fault action to be taken when a Drive Thermal Fault is detected, for an axis configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.
Motor Thermal
Specifies the fault action to be taken when a Motor Thermal Fault is detected, for an axis configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.
Feedback Noise
Specifies the fault action to be taken when excessive feedback noise is detected. The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.
Feedback
Specifies the fault action to be taken when Feedback Fault is detected. The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.
Position Error
Specifies the fault action to be taken when position error exceeds the position tolerance set for the axis, for an axis configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.
Hard Overtravel
Specifies the fault action to be taken when an axis encounters a travel limit switch, for an axis configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.
Soft Overtravel
Specifies the fault action to be taken when a software overtravel error occurs, for an axis with Soft Travel Limits enabled and configured (in the Limits tab of this dialog box) that is configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.
Phase Loss
Specifies the fault action to be taken when a phase loss situation occurs for an axis configured as Servo (on the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion and Status Only. The default is Shutdown. When Status Only is chosen, Logix Designer motion commands continue and the drive uses available stored DC bus energy to operate the axes.
Set custom stop
Opens the Custom Stop Action dialog box.
172
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
Page 173
Axis properties
Set custom stop action
Appendix A
Use the Custom Stop Action Attributes dialog box to monitor and edit the Stop Action-related attributes.
When a parameter transitions to a read-only state, any pending changes to parameter values are lost, and the parameter reverts to the most recently saved parameter value. When multiple workstations connect to the same controller using Logix Designer application and invoke the Axis Wizard or Axis Properties dialog box, the firmware allows only the first workstation to make any changes to axis attributes. The second workstation switches to view only. Attribute
Description
StoppingTorque
Displays the amount of torque available to stop the motor. The value range of this attribute is 0...1000.
StoppingTimeLimit
Displays the maximum amount of time that the drive amplifier remains enabled while trying to stop. Useful for very slow velocity rate change settings. The value range of this attribute is 0...6553.5 units.
BrakeEngageDelayTime
When servo axis is disabled and the drive decelerates to a minimum speed, the drive maintains torque until this time has elapsed. This time allows the motor’s brake to be set. The value range of this attribute is 0...6.5535.
BrakeReleaseDelayTime
When the servo axis is enabled, the drive activates the torque to the motor but ignores the command values from the Logix controller until this time has elapsed. This time allows the motor’s brake to release. The value range of this attribute is 0...6.5535.
ResistiveBrakeContactDelay
The Resistive Brake Contact Delay attribute is used to control an optional external Resistive Brake Module (RBM). The RBM sits between the drive and the motor and uses an internal contactor to switch the motor between the drive and a resisted load.
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
173
Page 174
Appendix A
Axis properties
Tag tab
Use this tab to modify the name and description of the axis. When online, all parameters on this tab transition to a read-only state. If changes are not saved before going online, all pending changes revert to their previously-saved state.
Parameter
Description
Name
Displays the name of the current tag. Cn rename this tag.
Description
Displays the description of the current tag, if any is available. Can edit this description.
Tag Type
Indicates the type of the current tag. This type may be: • Base • Alias • Consumed Displays the data type associated with the current tag.
Data Type
Displays the axis data type of the current tag.
Scope
Displays the scope of the current tag. The scope is controller scope, or program scope, based on one of the programs in the controller.
Style
Displays the default style in which to display the value of the tag. Note that style is only applicable to an atomic tag; a structure tag does not have a display style.
Monitoring axis tags
In Data Monitor or Tag Monitor, sort the tags alphabetically. Right-click on the Name column and select Sort Column.
174
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
Page 175
Axis properties
Appendix A
Optionally, select Include Tag Members in Sorting.
Create reports
Print a variety of reports in Logix Designer application. To create a report: 1. In the Controller Organizer, right-click Controller Tags, MainTask, MainProgram, axis, Add-On Instructions, or Data Types and select Print. 2. On the Print dialog box, select Adobe PDF and select Print Options.
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
175
Page 176
Appendix A
Axis properties
3. When printing a Tag Listing, select Include Special Properties and Advanced List to see the information.
Axis Properties Example
Right-click a controller, communication module, and any motion module to print the configured Module Properties.
176
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
Page 177
Axis properties
Appendix A
Module Properties Example
See also Axis properties on page 119
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
177
Page 178
Page 179
Appendix B
Motion axis attributes
Introduction for Motion Axis Attributes
The Access column shows how to access the attribute. Attribute
Axis Type
Acceleration Feedforward Gain
Accessing an MSG instruction
Data Type
Access
Description
GSV
Use a Get System Value (GSV) instruction to get the value.
SSV
Use a Set System Value (SSV) instruction to set or change the value. Modify the attribute only when the axis is not enabled.
Accel Status
Tag
Actual Acceleration
GSV
Use the tag for the axis to get the value.
Tag
Use the tag for the axis or a GSV instruction to get the value. Using the tag is easier.
For complete information about accessing data using an MSG instruction, see Logix 5000 Controllers Messages Programming Manual, publication 1756PM012. For more information on Attribute and Class IDs, see the drive documentation.
Interpreting the Attribute Tables
This table provides an explanation of the information, nomenclature, and abbreviations used in the attribute tables. Column Heading
Description
Attribute
Each attribute table begins with the attribute name. The tag, GSV/SSV, and MSG names for each of these attributes are the same as the attribute name listed, but with the spaces removed. For example, Absolute Feedback Enable would be AbsoluteFeedbackEnable.
Axis Type
For each attribute, the related axis is listed.
Data Type
The data type, such as DINT, UINT, SINT, REAL, and BOOL.
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
179
Page 180
Appendix B
Motion axis attributes
Replicated Attributes
180
Column Heading
Description
Access
GSV SSV Tag MSG
Description
Attribute value meanings, such as Position Units / Seconds. Supports tag access , but value is valid only when Auto Tag Update of the Motion Group Object is enabled.
Read via the GSV instruction. Write via the SSV instruction. Create to allocate and reference data. Message is only used to access drive attributes that have no GSV/SSV access. Using an MSG instruction to access information from a drive requires the Attribute and Class IDs. See the drive documentation for ID information.
Controller attributes replicated in the motion module: •
AccelerationFeedForwardGain
•
AxisType
•
DriveFaultAction
•
FeedbackFaultAction
•
FeedbackNoiseFaultAction
•
FrictionCompensation
•
MaximumNegativeTravel
•
MaximumPositiveTravel
•
OutputLPFilterBandwidth
•
OutputLimit
•
OutputOffset
•
PositionErrorFaultAction
•
PositionErrorTolerance
•
PositionIntegralGain
•
PositionProportionalGain
•
PositionUnwind
•
SoftOvertravelFaultAction
•
TorqueScaling
•
VelocityFeedforwardGain
•
VelocityIntegralGain
•
VelocityProportionalGain
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018