Motion axis attributes

Servo Feedback Type

Appendix B

AXIS_SERVO

SINT

GSV

This attribute provides a selection for the Feedback Type. 0 = A Quadrature B (AQB) 1 = Synchronous Serial Interface (SSI) 2 = Linear Displacement Transducer (LDT) A Quadrature B Encoder Interface (AQB) Servo modules, such as the 1756-M02AE, provide interface hardware to support incremental quadrature encoders equipped with standard 5-Volt differential encoder interface signals. This interface hardware provides a robust differential encoder input interface to condition each of the encoder signals before being applied to an Encoder-toDigital Converter (EDC) FPGA. The EDC decodes the encoder signals and uses a 16-bit bidirectional counter to accumulate feedback counts. A regular Timer Event signal, applied to the EDC, latches the encoder counters for all axes simultaneously. This same Timer Event signal also triggers the servo interrupt service routine that performs the servo loop computations. One of the first things done by the interrupt service routine is to read the latched encoder counter values from the EDC. The change in the encoder counter value from the last timer event is computed and this delta value is added to a 32-bit signed integer position accumulator, which represents the Actual Position of the axis. The Actual Position value is used as feedback to the position servo loop and as input to the Watch Event Handler. The delta position value represents velocity feedback, which when configured to do so, may be filtered and applied to the inner velocity servo loop. Synchronous Serial Interface (SSI) Some servo modules, like the 1756-M02AS, provide an interface to transducers with Synchronous Serial Interface (SSI) outputs. SSI outputs use standard 5V differential signals (RS422) to transmit information from the transducer to the controller. The signals consist of a Clock generated by the controller and Data generated by the transducer. Each transducer with an SSI output provides output data of a specified number of bits of Binary or Gray code data. The controller must generate a stream of clock pulses with the correct number of bits and a frequency within the range supported by the transducer. The servo module can be configured via the Servo Axis Object to generate any number of clock pulses between 8 and 32, and the frequency can be set to 208kHz or 650kHz. The clock signal is maintained in the High state between pulse strings. The transducer shifts data out on the Data line MSB first on each rising edge of the clock signal. The transducer also maintains the data signal in specified states before and after the data is shifted out. These states are checked by the controller to detect missing transducers or broken wires. A Field Programmable Gate Array (FPGA) is used to implement a multi-channel SSI Interface on the controller. Each channel is functionally equivalent. Linear Displacement Transducer (LDT) Servo modules like the 1756-HYD02 use the Linear Magnetostrictive Displacement Transducer, or LDT. A Field Programmable Gate Array (FPGA) is used to implement a multichannel LDT Interface. Each channel is functionally equivalent and is capable of interfacing to an LDT device with a maximum count of 240,000. The LDT interface includes transducer failure detection and digital filtering to reduce electrical noise. The FPGA can interface to two types of LDTs: Start/Stop and PWM. Start/Stop transducers accept an input (interrogate) signal to start the measurement cycle and respond with two pulses on the Return line. The time between the pulses is proportional to the position. PWM transducers respond to the interrogate signal with a long pulse on the Return line. The pulse width is proportional to the position. The FPGA generates the Interrogate signal every Servo Update time and measures the time between the Start/Stop pulses or the PWM pulse width. The resolution of the position measurement is determined by the frequency of the clock used for the time measurement. In the 1756-HYD02 design, a 60 MHz clock is used, and both edges of the clock signal are used for an effective time resolution of 8.3 nanoseconds. This translates into a position resolution better than 0.001 inch.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

251

Page 252

Appendix B

Motion axis attributes

Attribute

Axis Type

Data Type

Access

Description Note: It is possible to achieve higher resolutions with PWM transducers that are configured to perform multiple internal measurements (recirculations) and report the sum of those measurements in the pulse width.

Servo Loop Configuration

AXIS_SERVO AXIS_SERVO_DRIVE

INT

GSV SSV

The Servo Loop Configuration attribute determines the configuration of the servo loop topology when the axis is set to ‘servo’. 0 = custom 1 = feedback only 2 = aux. feedback only 3 = position servo 4 = aux. position servo 5 = dual position servo 6 = dual command servo 7 = aux. dual command servo 8 = velocity servo 9 = torque servo 10 = dual command/feedback servo

Servo Output Level

AXIS_SERVO

REAL

GSV Tag

Important: To use this attribute, choose it as one of the attributes for Real Time Axis Information for the axis. Otherwise, the right value is not seen as the axis runs. See Axis Info Select 1. Servo Output Level in Volts Servo Output Level is the current voltage level of the servo output of the specified axis. The Servo Output Level can be used in drilling applications, for example, where the servo module is interfaced to an external Torque Loop Servo Drive, to detect when the drill bit engages the surface of the work piece.

Servo Polarity Bits

AXIS_SERVO

DINT

GSV

0 = Feedback Polarity Negative 1 = Servo Polarity Negative Feedback Polarity Negative This Feedback Polarity Negative bit attribute controls the polarity of the encoder feedback and, when properly configured, insures that when the axis is moved in the user defined positive direction, and that the axis Actual Position value increases. This bit can be configured automatically using the MRHD and MAHD motion instructions. Servo Polarity Negative This Servo Polarity Negative bit attribute controls the polarity of the servo output to the drive. When properly configured along with the Feedback Polarity Negative bit, it insures that when the axis servo loop is closed, that it is closed as a negative feedback system and not an unstable positive feedback system. This bit can be configured automatically using the MRHD and MAHD motion instructions.

252

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 253

Motion axis attributes

Appendix B

Attribute

Axis Type

Data Type

Access

Description

Servo Status

AXIS_SERVO

DINT

Tag

Allows access to the status bits for the servo loop in one 32-bit word. This tag is the same as the Servo Status Bits attribute.

Servo Status Bits

AXIS_SERVO

DINT

GSV*

Allows access to the status bits for the servo loop in one 32-bit word. This attribute is the same as the Servo Status tag.

Shutdown Status

AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL

BOOL

Tag

If this bit is: • ON, The axis is in the Shutdown state. • OFF, The axis is not in the Shutdown state.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

253

Page 254

Appendix B

Motion axis attributes

Attribute

Axis Type

Data Type

Access

Soft Overtravel Fault Action

AXIS_SERVO AXIS_SERVO_DRIVE

SINT

GSV SSV

Description

This controller attribute is replicated in the motion module. SSI Clock Frequency

AXIS_SERVO

SINT

GSV

0 = 208 kHz 1 = 650 kHz This attribute provides for setting the Clock Frequency in kHz of the SSI device. This attribute is only active if the Transducer Type is set to SSI.

SSI Code Type

AXIS_SERVO

SINT

GSV

0 = Binary 1 = Gray This attribute provides for setting whether the SSI device is using Binary or Gray code. This attribute is only active if the Transducer Type is set to SSI.

SSI Data Length

AXIS_SERVO

SINT

GSV

This attribute provides for setting the data length of the SSI device. This attribute is only active if the Transducer Type is set to SSI.

Start Actual Position

AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL

REAL

GSV Tag

Start Actual Position in Position Units Whenever a new motion planner instruction starts for an axis (for example, using an MAM instruction), the value of the axis command position and actual position is stored at the precise instant the motion begins. These values are stored as the Start Command Position and Start Actual Position respectively in the configured Position Units of the axis. Start Positions are useful to correct for any motion occurring between the detection of an event and the action initiated by the event. For instance, in coil winding applications, Start Command Positions can be used in an expression to compensate for overshooting the end of the bobbin before the gearing direction is reversed. If the position of the coil when the gearing direction was supposed to change, and the position at which it actually changed (the Start Command Position) are known, calculate the amount of overshoot, and use it to correct the position of the wire guide relative to the bobbin.

Start Command Position

AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL

REAL

GSV Tag

Start Command Position in Position Units Whenever a new motion planner instruction starts for an axis (for example, using an MAM instruction), the value of the axis command position and actual position is stored at the precise instant the motion begins. These values are stored as the Start Command Position and Start Actual Position respectively in the configured Position Units of the axis. Start Positions are useful to correct for any motion occurring between the detection of an event and the action initiated by the event. For instance, in coil winding applications, Start Command Positions can be used in an expression to compensate for overshooting the end of the bobbin before the gearing direction is reversed. If the position of the coil when the gearing direction was supposed to change, and the position at which it actually changed (the Start Command Position) are known, calculate the amount of overshoot, and use it to correct the position of the wire guide relative to the bobbin.

Start Master Offset

AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL

REAL

GSV Tag

Start Master Offset in Master Position Units The Start Master Offset is the position offset that was applied to the master side of the position cam when the last Motion Axis Move (MAM) instruction with the move type set to ‘Absolute Master Offset’ or ‘Incremental Master Offset’ was executed. The Start Master Offset is returned in master position units. The Start Master Offset shows the same unwind characteristic as the position of a linear axis.

254

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 255

Motion axis attributes

Appendix B

Attribute

Axis Type

Data Type

Access

Description

Stopping Status

AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL

BOOL

Tag

Set if there is a stopping process currently in progress. Cleared when the stopping process is complete. The stopping process is used to stop an axis (initiated by an MAS, MGS, Stop Motion fault action, or mode change).

Stopping Time Limit

AXIS_SERVO_DRIVE

REAL

GSV SSV

Sec This attribute maps directly to a SERCOS IDN. See the SERCOS Interface standard for a description. This attribute is automatically set. Usually it does not need to be changed.

Stopping Torque

AXIS_SERVO_DRIVE

REAL

GSV SSV

% Rated This attribute maps directly to a SERCOS IDN. See the SERCOS Interface standard for a description. This attribute is automatically set. Usually it does not need to be changed.

Strobe Actual Position

AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL

REAL

GSV Tag

Strobe Actual Position in Position Units Strobe Actual Position and Strobe Command Position are used to simultaneously store a snap-shot of the actual, command position and master offset position of an axis when the MGSP (Motion Group Strobe Position) instruction is executed. The values are stored in the configured Position Units of the axis. Since the MGSP instruction simultaneously stores the actual and command positions for all axes in the specified group of axes, the resultant Strobe Actual Position and Strobe Command Position values can be used to perform real time calculations. For example, the Strobe Actual Positions can be compared between two axis to provide a form of ‘slip compensation’ in web handling applications.

Strobe Command Position

AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL

REAL

GSV Tag

Strobe Command Position in Position Units Strobe Actual Position and Strobe Command Position are used to simultaneously store a snap-shot of the actual, command position and master offset position of an axis when the MGSP (Motion Group Strobe Position) instruction is executed. The values are stored in the configured Position Units of the axis. Since the MGSP instruction simultaneously stores the actual and command positions for all axes in the specified group of axes, the resultant Strobe Actual Position and Strobe Command Position values can be used to perform real time calculations. For example, the Strobe Actual Positions can be compared between two axis to provide a form of ‘slip compensation’ in web handling applications.

Strobe Master Offset

AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL

REAL

GSV Tag

Strobe Master Offset in Master Position Units The Strobe Master Offset is the position offset that was applied to the master side of the position cam when the last Motion Group Strobe Position (MGSP) instruction was executed. The Strobe Master Offset is returned in master position units. The Strobe Master Offset shows the same unwind characteristic as the position of a linear axis.

Telegram Type

AXIS_SERVO_DRIVE

INT

GSV

Set to a value of 7, which means Application Telegram. See IDN 15 in IEC 1491.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

255

Page 256

Appendix B

Motion axis attributes

Attribute

Axis Type

Data Type

Access

Description

Test Direction Forward

AXIS_SERVO AXIS_SERVO_DRIVE

SINT

GSV

The direction of axis travel during the last hookup test initiated by a MRHD (Motion Run Hookup Test) instruction. 0 = reverse 1 = forward (positive)

Test Increment

AXIS_SERVO AXIS_SERVO_DRIVE

REAL

GSV SSV

Position Units The Motor Feedback Test Increment attribute is used in conjunction with the MRHD (Motion Run Hookup Diagnostic) instruction to determine the amount of motion that is necessary to satisfy the MRHD initiated test process. This value is typically set to approximately a quarter of a revolution of the motor.

Test Status

AXIS_SERVO AXIS_SERVO_DRIVE

INT

GSV

0 = test process successful 1 = test in progress 2 = test process aborted by user 3 = test process time-out fault (~2 seconds) 4 = test failed – servo fault 5 = test failed – insufficient test increment More for AXIS_SERVO_DRIVE data type… 6 = test failed – wrong polarity 7 = test failed – missing signal 8 = test failed – device comm error 9 = test failed – feedback config error 10 = test failed – motor wiring error This attribute returns the status of the last run MRHD (Motion Run Hookup Diagnostic) instruction that initiates a hookup diagnostic process on the axis. Use this attribute to determine when the MRHD initiated operation successfully completed. Conditions may occur, however, that make it impossible to properly perform the operation. When that happens, the test process is automatically aborted and a test fault reported that is stored in the Test Status output parameter.

Time Cam Pending Status

AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL

BOOL

Tag

Set if a Time Cam motion profile is currently pending the completion of a currently executing cam profile. This would be initiated by executing an MATC instruction with Pending execution selected. This bit is cleared when the current time cam profile completes, initiating the start of the pending cam profile. This bit is also cleared if the time cam profile completes, or is superseded by some other motion operation.

Time Cam Status

AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL

BOOL

Tag

Set if a Time Cam motion profile is currently in progress. Cleared when the Time Cam is complete or is superseded by some other motion operation.

256

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 257

Motion axis attributes

Appendix B

Attribute

Axis Type

Data Type

Access

Description

Timer Event Fault

AXIS_SERVO AXIS_SERVO_DRIVE

BOOL

Tag

If this bit is set, there is an issue with the timer event that synchronizes the motion module’s servo loop to the master timebase of the chassis (that is, Coordinated System Time). To clear this bit, reconfigure the motion module.

Torque Command

AXIS_SERVO_DRIVE

REAL

GSV Tag

Important: To use this attribute, choose it as one of the attributes for Real Time Axis Information for the axis. Otherwise, the right value is not seen as the axis runs. See Axis Info Select 1. %Rated The command when operating in Torque Mode in terms of % rated.

Torque Data Scaling

AXIS_SERVO_DRIVE

INT

GSV

This 16-bit attribute displays the scaling method to use on torque values (for example, Torque Command Value, and Bipolar torque limit value) with decimal values ranging from 0 to 127. Bit values are: • Bits 2-0: Scaling method •

000 – percentage scaling

•

001 – linear scaling (force)

•

010 – rotational scaling (torque)

•

0 – preferred scaling

•

1 – parameter scaling

• Bit 3:

• Bit 4: Units •

0 – Newton meter (Nm)

•

1 – inch pound force (lbf)

• Bit 5: (reserved) • Bit 6: Data reference •

0 – at the motor shaft

• 1 – at the load All other bits are reserved Torque Data Scaling Exp

AXIS_SERVO_DRIVE

INT

GSV

This 16-bit unsigned attribute displays the scaling exponent for all torque data in a drive, with decimal values ranging from -2^15 to (2^15)-1. Bit values are: • Bit 14-0: Exponent value • Bit 15: Exponent sign: •

0 - Positive

•

1 - Negative

Torque Data Scaling Factor

AXIS_SERVO_DRIVE

DINT

GSV

This 16-bit unsigned attribute displays the scaling factor for all torque data in a drive, with decimal values ranging from 1 to (2^16)-1.

Torque Feedback

AXIS_SERVO_DRIVE

REAL

GSV Tag

Important: To use this attribute, choose it as one of the attributes for Real Time Axis Information for the axis. Otherwise, the right value is not seen as the axis runs. See Axis Info Select 1. %Rated The torque feedback when operating in Torque Mode in terms of % rated.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

257

Page 258

Appendix B

Motion axis attributes

Attribute

Axis Type

Data Type

Access

Description

Torque Limit Bipolar

AXIS_SERVO_DRIVE

REAL

GSV SSV

%Rated The Torque Limit attribute provides a method of limiting the maximum command current/torque to the motor to a specified level in terms of the motor’s continuous current/torque rating. The output of the servo drive to the motor as a function of position servo error, with and without servo torque limiting, is shown below.

The torque limit specifies the maximum percentage of the motors rated current that the drive can command as positive or negative torque. For example, a torque limit of 150% shall limit the current delivered to the motor to 1.5 times the continuous current rating of the motor. Torque Limit Negative

AXIS_SERVO_DRIVE

REAL

GSV SSV

%Rated This attribute maps directly to a SERCOS IDN. See the SERCOS Interface standard for a description. This attribute is automatically set. Usually it does not need to be changed.

Torque Limit Positive

AXIS_SERVO_DRIVE

REAL

GSV SSV

%Rated This attribute maps directly to a SERCOS IDN. See the SERCOS Interface standard for a description. This attribute is automatically set. Usually it does not need to be changed.

Torque Limit Source

AXIS_SERVO_DRIVE

DINT

GSV Tag

Important: To use this attribute, choose it as one of the attributes for Real Time Axis Information for the axis. Otherwise, the right value is not seen as the axis runs. See Axis Info Select 1. This parameter displays the present source (if any) of any torque limiting for the axis. 0 = Not Limited 1 = Neg. Torque Limit 2 = Pos. Torque Limit 3 = Amp Peak Limit 4 = Amp I(t) Limit 5 = Bus Regulator Limit 6 = Bipolar Torque Limit 7 = Motor Peak Limit 8 = Motor I(t) Limit 9 = Voltage Limit

Torque Limit Status

AXIS_SERVO_DRIVE

BOOL

Tag

Set when the magnitude of the axis torque command is greater than the configured Torque Limit.

258

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 259

Motion axis attributes

Appendix B

Attribute

Axis Type

Data Type

Access

Description

Torque Offset

AXIS_SERVO AXIS_SERVO_DRIVE

REAL

GSV SSV Tag

Torque Offset from –100% to +100% Torque Offset compensation can be used to provide a dynamic torque command correction to the output of the velocity servo loop. Since this value is updated synchronously every Base Update Period, the Torque Offset can be tied into custom outer control loop algorithms using Function Block programming.

Torque Polarity

AXIS_SERVO_DRIVE

INT

GSV

G10/Configuration It maps directly to the SERCOS IDN. It is automatically set based on the current Drive Polarity Settings. All command bits are set according to the Command polarity bit value and all feedback bits are set according to the Feedback Polarity bit setting.

Torque Scaling

AXIS_SERVO AXIS_SERVO_DRIVE

REAL

GSV SSV

% / Position Units Per Second2 This controller attribute is replicated in the motion module. The Torque Scaling attribute is used to convert the acceleration of the servo loop into equivalent % rated torque to the motor. This ‘normalizes’ the units of the servo loop’s gain parameters so that their values are not affected by variations in feedback resolution, drive scaling, motor and load inertia, and mechanical gear ratios. In fact, the Torque Scaling value, when properly established, represents the inertia of the system and is related to the Tune Inertia attribute value by a factor of the Conversion Constant. • AXIS_SERVO, The Torque Scaling value is typically established by the MAAT instruction as part of the controller’s automatic tuning procedure. • AXIS_SERVO_DRIVE, The Torque Scaling value is typically established by the drive’s automatic tuning procedure. The value can be manually calculated, if necessary, using these guidelines. Torque Scaling = 100% Rated Torque / (Acceleration @ 100% Rated Torque) For example, if this axis is using position units of motor revolutions (revs), and that with 100% rated torque applied to the motor, the motor accelerates at a rate of 3000 Revs/Sec2, the Torque Scaling attribute value would be calculated as shown below. Torque Scaling = 100% Rated / (3000 RPS2) = 0.0333% Rated/ Revs Per Second2 Note that if the Torque Scaling value does not reflect the true torque to acceleration characteristic of the system, the gains also do not reflect the true performance of the system.

Torque Threshold

AXIS_SERVO_DRIVE

REAL

GSV SSV

%Rated This attribute maps directly to a SERCOS IDN. See the SERCOS Interface standard for a description. This attribute is automatically set. Usually it does not need to be changed.

Torque Threshold Status

AXIS_SERVO_DRIVE

BOOL

Tag

Set when the magnitude of the physical axis Torque Feedback is less than the configured Torque Threshold.

Transform State Status

AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL

BOOL

Tag

If the bit is: • ON, The axis is part of an active transform.

AXIS_SERVO AXIS_SERVO_DRIVE

REAL

Tune Acceleration

• OFF, The axis is not part of an active transform.

GSV

Position Units / Sec2 The Tune Acceleration and Tune Deceleration attributes return the measured acceleration and deceleration values for the last run tuning procedure. These values are used, in the case of an external torque servo drive configuration, to calculate the Tune Inertia value of the axis, and are also typically used by a subsequent MAAT (Motion Apply Axis Tune) to determine the tuned values for the Maximum Acceleration and Maximum Deceleration attributes.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

259

Page 260

Appendix B

Motion axis attributes

Attribute

Axis Type

Data Type

Access

Description

Tune Acceleration Time AXIS_SERVO AXIS_SERVO_DRIVE

REAL

GSV

Sec The Tune Acceleration Time and Tune Deceleration Time attributes return acceleration and deceleration time in seconds for the last run tuning procedure. These values are used to calculate the Tune Acceleration and Tune Deceleration attributes.

Tune Deceleration

AXIS_SERVO AXIS_SERVO_DRIVE

REAL

GSV

Position Units / Sec2 The Tune Acceleration and Tune Deceleration attributes return the measured acceleration and deceleration values for the last run tuning procedure. These values are used, in the case of an external torque servo drive configuration, to calculate the Tune Inertia value of the axis, and are also typically used by a subsequent MAAT (Motion Apply Axis Tune) to determine the tuned values for the Maximum Acceleration and Maximum Deceleration attributes.

Tune Deceleration Time AXIS_SERVO AXIS_SERVO_DRIVE

REAL

GSV

Sec The Tune Acceleration Time and Tune Deceleration Time attributes return acceleration and deceleration time in seconds for the last run tuning procedure. These values are used to calculate the Tune Acceleration and Tune Deceleration attributes.

Tune Inertia

REAL

GSV

% / MegaCounts Per Sec2 The Tune Inertia value represents the total inertia for the axis as calculated from the measurements made during the tuning procedure. In actuality, the units of Tune Inertia are not industry standard inertia units but rather in terms of percent (%) of rated drive output per MegaCounts/Sec2 of feedback input. In this sense, it represents the input gain of torque servo drive. These units represent a more useful description of the inertia of the system as seen by the servo controller. The Tune Inertia value is used by the MAAT (Motion Apply Axis Tune) instruction to calculate the Torque Scaling. If the Tune Inertia value exceeds 100%Rated/MegaCounts Per Second2, performance of the digital servo loop may be compromised due to excessive digitization noise associated with the velocity estimator. This noise is amplified by the Torque Scaling gain, which is related to the Tune Inertia factor and passed on to the torque output of the drive. A high Tune Inertia value can, thus, result in excitation of mechanical resonances and also result in excessive heating of the motor due to high torque ripple. The only solution to this problem is to lower the loop bandwidths and optionally apply some output filtering. Since the Tune Inertia value represents a measure of the true system inertia, this situation can occur when driving a high inertia load relative to the motor, that is, a high inertia mismatch. But it can also occur when working with a drive that is undersized for the motor or with a system having low feedback resolution. In general, the lower the Tune Inertia the better the performance of the digital servo loops approximates that of an analog servo system. The product of the Tune Inertia (% Rated/MCPS) and the Velocity Servo BW (Hertz) can be calculated to directly determine quantization noise levels. Based on this product, the tuning algorithm can take action to limit high frequency noise injection to the motor. For motors with a Tune Inertia BW product of 1000 or more, the LP Filter is applied with a Filter BW of 5x the Velocity Servo Bandwidth in Hertz. This limits the amount of phase lag introduced by the LP filter to ~12 degrees, which is relatively small compared to the 30 to 60 degrees of phase margin that exists for a typical tuned servo system. With a typical tuned LP filter BW value of 200 Hz, we can expect the high frequency quantization noise in the 1 KHz range to be attenuated roughly by a factor of 5. When the Tune Inertia BW product reaches 4000 or more, the LP filter alone is not going to be enough to manage the quantization noise level. So the tune algorithm begins to taper the system bandwidth by the ratio of 4000/(Tune Inertia * Vel Servo BW). This holds the quantization noise level at a fixed value, independent of the Tune Inertia BW product. For example, a motor with a Tune Inertia value of 213 and a Vel Servo BW of 41 Hz (8733 Inertia BW product) tunes with a Pos P Gain of 46 and a Vel P Gain of 117 and LP Filter BW of 93. This is a good noise-free gain set.

260

AXIS_SERVO AXIS_SERVO_DRIVE

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018