Select a CompactLogix System
DeviceNet Communication Options The DeviceNet network is an open, low-level network that provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers). Cat. No.
Description
Communication Rate
Number of Nodes
1769-SDN
Compact I/O DeviceNet scanner
64
1769-ADN
Compact I/O DeviceNet adapter
125 Kbps (500 m, max) 250 Kbps (250 m, max) 500 Kbps (100 m, max)
Serial Communication Options These CompactLogix controllers support serial communication. Cat. No.
Serial Options
1769-L16ER-BB1B, 1769-L18ER-BB1B, 1769-L18ERM-BB1B, 1769-L19ERM-BB1B
1734-232ASC module for an RS-232 serial interface 1734-485 ASC module for an RS-422 and RS-485 serial device
1769-L24ER-BB1B, 1769-L24ER-QBFC1B
1769-ASCII module for an ASCII interface to RS-232, RS-422, and RS-485 devices 1769-SM2 module for a Modbus RTU interface
1769-L27ERM-QBFC1B 1769-L30ER, 1769-L30ERM, 1769-L30ERMS 1769-L33ER, 1769-L33ERM, 1769-L33ERMO, 1769-L33ERMOS, 1769-L33ERMS 1769-L36ERM, 1769-L36ERMO, 1769-L36ERMOS, 1769-L36ERMS, 1769-L37ERMO, 1769-L37ERMOS
Modbus Support To access a Modbus TCP network, connect through the embedded Ethernet port of the CompactLogix 5370 or CompactLogix 5380 controllers and execute a ladder-logic routine. For more information, see Knowledgebase document 470365 at http://www.rockwellautomation.com/knowledgebase/. To access a Modbus RTU network, connect through a 1769-SM2 module, or Encompass partner, Prosoft ModuBus module, or Gateway and execute a ladder-logic routine. For more information, see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution, publication CIG-AP129.
Rockwell Automation Publication 1769-SG001S-EN-P - December 2016
21
Page 22
Select a CompactLogix System
CompactLogix Integrated Motion The Logix architecture supports motion control components that work in a wide variety of machine architectures. • Integrated motion on EtherNet/IP supports a connection to Ethernet drives. • The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis, synchronized motion. • Logix integrated motion supports the analog family of servo modules for controlling drives/actuators. • Networked motion lets you connect via the DeviceNet network to one axis drive to perform point-to-point indexing. • Not all CompactLogix 5370 and CompactLogix 5380 controllers support Integration motion on EtherNet/IP. • All CompactLogix 5380 controllers support single-axis motor control with PowerFlex variable frequency drives over an EtherNet/IP network. This functionality is available on CompactLogix 5380 controllers that do not support other aspects of Integrated Motion over an EtherNet/IP network. Motion Feature
1769-L18ERM-BB1B
EtherNet/IP sequence of events for software registration
Yes
Kinematics
Yes
Integrated motion on an EtherNet/IP network
Yes
Indexing
Yes with one of these pulsetrain output modules: • AMCI 1734-3401 • AMCI 1734-3401L
Load observer (with only Kinetix 6500 drives)
Yes
Total axis count
100
Virtual axis, max
100
Position-loop axis, max
2
Axis/ms, max
2
EtherNet/IP feedback, VHz, torque, or velocity axis, max
8
1769-L27ERM-QBFC1B
1769-L30ERM, 1769-L30ERMS, 1769-L33ERM, 1769-L33ERMO, 1769-L33ERMOS, 1769-L33ERMS, 1769-L36ERM, 1769-L36ERMO, 1769-L36ERMOS, 1769-L36ERMS, 1769-L37ERMO, 1769-L37ERMOS
5069-L306ERM, 5069-L310ERM, 5069-L320ERM, 5069-L330ERM, 5069-L340ERM 5069-L350ERM 5069-L380ERM 5069-L3100ERM
Yes with AMCI 1769-3602 pulse-train output module
Yes
4
• • • • • • • •
16
5069-L306ERM: 2 5069-L310ERM: 4 5069-L320ERM: 8 5069-L330ERM: 16 5069-L340ERM: 20 5069-L350ERM: 24 5069-L380ERM: 28 5069-L3100ERM: 32
32 16
48
80
For more information, see the: • CompactLogix 5380 Controllers User Manual, publication 5069-UM001. • Integrated Motion on the EtherNet/IP network Configuration and Startup User Manual, publication MOTION-UM003. • Integrated Motion on the EtherNet/IP network Reference Manual, Publication MOTION-RM003. • Motion Analyzer CD to size your motion application and to make final component selection. Download the software from http://www.ab.com/motion/software/analyzer.html. • Kinetix Motion Control Selection Guide, publication GMC-SG001, to verify drive, motor, and accessory specifications.
22
Rockwell Automation Publication 1769-SG001S-EN-P - December 2016
Page 23
Select a CompactLogix System
Compact GuardLogix Integrated Safety The Compact GuardLogix controller provides safety control to achieve SIL 3/PLe according to ISO 13849. A major benefit of this system is that it is still one project, safety and standard together. Application
Description
SIL 1, 2, 3
The Compact GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508, and applications up to and including PLe/Cat.4 according to ISO 13849-1. For more information, see: • GuardLogix Controllers User Manual, publication 1769-UM022. • GuardLogix 5570 and Compact GuardLogix 5370 Controller Safety Systems Safety Reference Manual, publication 1756-RM099. • Compact GuardLogix Controllers User Manual, publication 1768-UM002. • GuardLogix Safety Application Instruction Set Reference Manual, publication 1756-RM095.
During development, safety and standard have the same rules, multiple programmers, online editing, and forcing are all possible. Once the project is tested and ready for final validation, you apply the safety application signature and safety-lock the application to set the safety task to a SIL 3 integrity level. The GuardLogix controller enforces the SIL 3 integrity level. When safety memory is locked and protected, the safety logic cannot be modified and all safety functions operate with SIL 3 integrity. On the standard side of the GuardLogix controller, all functions operate like a regular Logix controller. Thus online editing, forcing, and other activities are all possible. With this level of integration, standard logic and external devices, like HMIs or other controllers, can read safety memory, avoiding the need to condition safety memory for use elsewhere. The result is easy system-wide integration and the ability to display safety status on displays or marquees. Use Guard I/O™ modules for field device connectivity. For safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks. Multiple GuardLogix controllers can share safety data for zone to zone interlocking, or one GuardLogix controller can use remote distributed safety I/O between cells/areas. The Compact GuardLogix controller has these safety-related features and the standard features of a CompactLogix controller. Characteristic
1769-L30ERMS
1769-L33ERMS
1769-L36ERMS
1768-L43S
1768-L45S
Available user memory
1 MB standard 0.5 MB safety
2 MB standard 1 MB safety
3 MB standard 1.5 MB safety
2 MB standard 0.5 MB safety
3 MB standard 1 MB safety
Communication options
• Dual-port EtherNet/IP (standard and safety) • DeviceNet (standard)
• EtherNet/IP (standard and safety) • ControlNet (standard and safety) • DeviceNet (standard)
• EtherNet/IP (standard and safety) • ControlNet (standard and safety) • DeviceNet (standard)
Programming languages
• Standard task: all languages • Safety task: relay ladder, safety application instructions
Rockwell Automation Publication 1769-SG001S-EN-P - December 2016
23
Page 24
Select a CompactLogix System
Armor CompactLogix and Armor Compact GuardLogix Integrated Safety The Armor CompactLogix and Armor Compact GuardLogix controllers extend the features of the CompactLogix 5370 and Compact GuardLogix 5370 controllers to On-Machine space. The Armor Compact GuardLogix controllers deliver integrated safety control up to and including SIL 3, according to IEC 61508 and Ple/CAT. 4, according to ISO 13849-1. Application
Description
SIL 1, 2, 3
The Compact GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508, and applications up to and including PLe/Cat.4 according to ISO 13849-1. For more information, see: • GuardLogix Controllers User Manual, publication 1769-UM022. • GuardLogix 5570 and Compact GuardLogix 5370 Controller Safety Systems Safety Reference Manual, publication 1756-RM099. • Compact GuardLogix Controllers User Manual, publication 1768-UM002. • GuardLogix Safety Application Instruction Set Reference Manual, publication 1756-RM095.
During development, safety and standard have the same rules, multiple programmers, online editing, and forcing are all possible. Once the project is tested and ready for final validation, you apply the safety application signature and safety-lock the application to set the safety task to a SIL 3 integrity level. The Armor Compact GuardLogix controller enforces the SIL 3 integrity level. When safety memory is locked and protected, the safety logic cannot be modified and all safety functions operate with SIL 3 integrity. On the standard side of the Armor Compact GuardLogix controller, all functions operate like a regular Logix controller. Thus online editing, forcing, and other activities are all possible. With this level of integration, standard logic and external devices, like HMIs or other controllers, can read safety memory, avoiding the need to condition safety memory for use elsewhere. The result is easy system-wide integration and the ability to display safety status on displays or marquees. Use Guard I/O modules for field device connectivity. For safety interlocking between Armor Compact GuardLogix controllers use Ethernet or ControlNet networks. Multiple Armor Compact GuardLogix controllers can share safety data for zone to zone interlocking, or one GuardLogix controller can use remote distributed safety I/O between cells/areas. The Armor CompactLogix and Armor Compact GuardLogix controllers have these safety-related features and the standard features of a CompactLogix controller. Characteristic
1769-L33ERMO
1769-L33ERMOS
1769-L36ERMO, 1769-L37ERMO
1769-L36ERMOS, 1769-L37ERMOS
Available user memory
2 MB
• 2 MB standard • 1 MB safety
3 MB
• 3 MB standard • 1.5 MB safety
Communication options
• Dual-port EtherNet/IP (standard and safety) • DLR
Programming languages
• Standard task: all languages • Safety task: relay ladder
24
Rockwell Automation Publication 1769-SG001S-EN-P - December 2016
Page 25
Select a CompactLogix System
Additional Local I/O Modules 1734 POINT I/O Modules Additional 1734 POINT I/O modules can be installed on a CompactLogix 5370 L1 controller. The POINT I/O family is ideal for applications where flexibility and low cost of ownership are key for successful control system design and operation. The base (A) mounts onto the DIN rail and provides the backplane. The POINT I/O module (B) snaps into the base. The removable terminal block (C) also snaps into the base and provides the wiring and terminations for field-side connections, and system power for the backplane.
1734 AC Digital Modules Cat. No.
Inputs/Outputs
Voltage Category
Wiring Base
POINTBus™ Current @ 5V DC
1734-IA2
2 inputs, nonisolated, sink
120V AC
1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS
75 mA
1734-IA4
4 inputs, nonisolated, sink
1734-IM2
2 inputs, nonisolated, sink
220V AC
1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS
75 mA
1734-IM4
4 inputs, nonisolated, sink
1734-OA2
2 outputs, nonisolated, source
120/220V AC
1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS
75 mA
1734-OA4
4 outputs, nonisolated, source
1734 DC Digital Modules Cat. No.
Inputs/Outputs
Voltage Category
Wiring Base
POINTBus Current @ 5V DC
1743-IB2
2 inputs, sink
24V DC
1734-TB, 1734-TBS
75 mA
1734-IB4
4 inputs, sink
1734-IB4D
4 inputs, sink, diagnostic
24V DC
1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS
50 mA
1734-IB8
8 inputs, sink
24V DC
1734-TB, 1734-TBS
75 mA
1734-IB8S
8 inputs, sink, safety
24V DC
1734-TB,1734-TOP
175 mA
1734-IV2
2 inputs, source
24V DC
1734-TB,1734-TBS
75 mA
1734-IV4
4 inputs, source
1734-IV8
8 inputs, source
Rockwell Automation Publication 1769-SG001S-EN-P - December 2016
25
Page 26
Select a CompactLogix System
Cat. No.
Inputs/Outputs
Voltage Category
Wiring Base
POINTBus Current @ 5V DC
1734-OB2
2 outputs, nonisolated, source
12/24V DC
1734-TB, 1734-TBS
75 mA
1734-OB2E
2 outputs, nonisolated protected, source
1734-OB4
4 outputs, nonisolated, source
1734-OB4E
4 outputs, nonisolated protected, source
1734-OB8
8 outputs, nonisolated, source
1734-OB8E
8 outputs, nonisolated protected, source
1734-OB8S
8 outputs, safety
24V DC
1734-TB,1734-TOP
190 mA
1734-OV2E
2 outputs, nonisolated protected, sink
12/24V DC
1734-TB, 1734-TBS
75 mA
1734-OV4E
4 outputs, nonisolated protected, sink
1734-OV8E
8 outputs, nonisolated protected, sink
1734 Relay Contact Output Modules Cat. No.
Inputs/Outputs
Voltage Range
Wiring Base
POINTBus Current @ 5V DC
1734-OW2
2 Form A (normally open) relays
1734-TB,1734-TBS
80 mA
1734-OW4
4 Form A (normally open) relays
1734-OX2
2 Form C isolated (normally open; normally closed) electromechanical relays
5…28.8V DC @ 2.0 A 48V DC @ 0.5 A 125V DC @ 0.25 A 125V DC @ 2.0 A 240V AC @ 2.0 A
100 mA
1734 Analog and Temperature Modules Cat. No.
Inputs/Outputs
Range
Resolution
Wiring Base
POINTBus Current @ 5V DC
1734-IE2C
2 single-ended, nonisolated, current
4…20 mA 0…20 mA
16 bits over 0…21 mA 0.32 A/cnt
1734-TB, 1734-TBS
75 mA
1734-IE2V
2 single-ended, nonisolated, voltage
15 bits plus sign 0…10V (-0.0V under, +0.5V over) 320 V/cnt in unipolar or ±10V (-0.5V under, +0.5V over) bipolar mode
1734-IE4C
4 single-ended, nonisolated, current
4…20 mA 0…20 mA
16 bits - over 0…21 mA 0.32 A/cnt
1734-IE4S
4 inputs, single-ended, safety rated
0…20 mA, 4…20 mA ±5V, 0…5V, ±10V, 0…10V
12 bits
1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS, 1734-TOP3, 1734-TOP3S
110 mA
1734-IE8C
8 single-ended, nonisolated, current
4…20 mA 0…20 mA
16 bits - over 0…21 mA 0.32 A/cnt
1734-TB, 1734-TBS
75 mA
1734-IR2
2 single-ended, nonisolated
0…600
16 bits 9.5 m/cnt 0.03 °C/cnt (Pt385 @ 25 °C) [0.05 °F/cnt (Pt385 @ 77 °F)]
1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS
220 mA
1734-IR2E
2 single-ended, nonisolated, protected
0…220
16 bits 2.4 m/cnt 0.006 °C/cnt (Pt385 @ 25 °C) [0.0114 °F/cnt (Pt385 @ 77 °F)]
26
Rockwell Automation Publication 1769-SG001S-EN-P - December 2016
Page 27
Select a CompactLogix System
Cat. No.
Inputs/Outputs
Range
Resolution
Wiring Base
POINTBus Current @ 5V DC
1734-IT2I
2 differential, individually isolated
Sensors B, C, E, J, K, N, R, S, T
15 bits plus sign 2.5 V/cnt
1734-TBCJC
175 mA
1734-OE2C
2 single-ended, nonisolated, current
4…20 mA 0…20 mA
13 bits over 0…21mA 2.5 A/cnt (average) 3…2.7 A/cnt (typical range)
1734-TB, 1734-TBS, 1734-TB3, 1734-TB3S
75 mA
1734-OE2V
2 single-ended, nonisolated, voltage
0…10V (-0.0V under, +0.5V 14 bits (13 plus sign) over) 1.28 mV/cnt in unipolar or ±10V (-0.5V under, +0.5V over) bipolar mode
1734-OE4C
4 single-ended, nonisolated, current
4…20 mA 0…20 mA
16 bits over 0…21 mA 0.32 A/cnt)
1734 Counter Modules Cat. No.
Inputs/Outputs
Range
Frequency
Wiring Base
POINTBus Current @ 5V DC
1734-IJ
1 - 1 group of A/Areturn, B/Breturn and Z/Zreturn
5V DC
1734-TB, 1734-TBS, 1734-TB3, 1734-TB3S
160 mA
1734-IK
1 - 1 group of A/Areturn, B/Breturn and Z/Zreturn
15…24V DC
1.0 MHz counter and encoder X1 500 kHz encoder X2 (no filter 250 kHz encoder X4 (no filter)
1734-VHSC24
1 - 1 group of A/Areturn, B/Breturn and Z/Zreturn
15…24V DC
180 mA
1734-VHSC5
1 - 1 group of A/Areturn, B/Breturn and Z/Zreturn
5V DC
180 mA
160 mA
1734 Self-configurable Modules Cat. No.
Inputs/Outputs
Voltage Category
Wiring Base
POINTBus Current @ 5V DC
1734-8CFG
8 self-configurable
24V DC
1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS
100 mA
1734 Communication and Specialty Modules Cat. No.
Description
Wiring Base
1734-AENT
The single port adapter connects POINT I/O modules to the Ethernet network.
–
1734-AENTR
The adapter connects POINT I/O modules to a linear or DLR network and uses two copper network ports to connect to the network.
–
1734-232ASC
The 1734-232ASC and 1734-485ASC serial interface modules offer a serial-link communication interface solution for peripheral products with RS-232 (only 1734-232ASC), RS-485, and RS-422 ports (only 1734-485ASC.)
1734-TB, 1734-TBS
75 mA
1734-ARM
The 1734-ARM address reserve module reserves address and slot numbers to maintain a numbering scheme of a system. The 1734-ARM has no module configuration and does not communicate I/O data.
1734-TB, 1734-TBS
75 mA
1734-CTM
The common terminal module (1734-CTM) and voltage terminal module (1734-VTM) expand the termination capabilities of POINT I/O modules. Install the modules to support higher density (8 channel) POINT I/O modules.
1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS
75 mA
The 1734-SSI module collects serial data from absolute-position, encoding sensors that use standard serial synchronous interface (SSI) protocol.
1734-TB, 1734-TBS
110 mA
1734-485ASC
1734-VTM 1734-SSI
Rockwell Automation Publication 1769-SG001S-EN-P - December 2016
POINTBus Current
27
Page 28
Select a CompactLogix System
1769 Compact I/O Modules The 1769 Compact I/O modules can be used with the CompactLogix 5370 L2 and L3 controllers and 1768 CompactLogix controllers as follows:
Local I/O modules with CompactLogix 5370 L3 Controller
Remote I/O modules accessible by using a 1769-AENTR EtherNet/IP Adapter
• Local I/O modules • Remote I/O modules accessible by using a 1769-AENTR EtherNet/IP adapter
The modules mechanically lock together with a tongueand-groove design and have an integrated communication bus that is connected from module to module by a moveable bus connector. Each I/O module includes a built-in removable terminal block with fingersafe cover for connections to I/O sensors and actuators. The terminal block is behind a door at the front of the module. I/O wiring can be routed from beneath the module to the I/O terminals. For detailed specifications, see 1769 Compact I/O Modules Specifications Technical Data, publication 1769-TD006.
Power Supply Distance Ratings Check the specification table of each module for the power supply distance rating. This rating indicates how many slot positions the module can be from the power supply.
1769 AC Digital Modules Cat. No.
Inputs/Outputs
Voltage Category
Operating Voltage Range
Backplane Current
Power Supply Distance Rating
1769-IA8I
8 inputs, individually isolated
100/120V AC
79…132V AC, 47…63 Hz
90 mA @ 5.1V(1)
8
1769-IA16
16 inputs
100/120V AC
79…132V AC, 47…63 Hz
115 mA @ 5.1V
8
1769-IM12
12 inputs
200/240V AC
159…265V AC, 47…63 Hz
100 mA @ 5.1V
8
1769-OA8
8 outputs
100/240V AC
85…265V AC 47…63 Hz
145 mA @ 5.1V
8
1769-OA16
16 outputs
100/240V AC
85…265V AC 47…63 Hz
225 mA @ 5.1V
8
(1) Maximum is 190 mA.
28
Rockwell Automation Publication 1769-SG001S-EN-P - December 2016
Page 29
Select a CompactLogix System
1769 DC Digital Modules Cat. No.
Inputs/Outputs
Voltage Category
Operating Voltage Range
Backplane Current
Power Supply Distance Rating
1769-IG16
16 inputs
5V DC TTL
4.5…5.5V DC
120 mA @ 5.1V
8
1769-IQ16
16 inputs
24V DC sink/source
10…30V DC @ 30 °C (86 °F) 10…26.4V DC @ 60 °C (140 °F)
115 mA @ 5.1V
8
1769-IQ16F
16 inputs, high speed
24V DC sink/source
10…30V DC @ 30 °C (86 °F) 10…26.4V DC @ 60 °C (140 °F)
100 mA @ 5.1V
8
1769-IQ32
32 inputs
24V DC sink/source
10…30V DC @ 30 °C (86 °F) 10…26.4V DC @ 60 °C (140 °F)
170 mA @ 5.1V
8
1769-IQ32T
32 inputs
24V DC sink/source
20.4…26.4V DC @ 60 °C (140 °F)
170 mA @ 5.1V
8
1769-IQ6XOW4
6 inputs 4 outputs
24V DC sink/source input AC/DC normally open relay contact outputs
10…30V DC @ 30 °C (86 °F) 10…26.4V DC @ 60 °C (140 °F)
105 mA @ 5.1V 50 mA @ 24V
8
1769-OB8
8 outputs
24V DC source
20.4…26.4V DC
145 mA @ 5.1V
8
1769-OB16
16 outputs
24V DC source
20.4…26.4V DC
200 mA @ 5.1V
8
1769-OB16P
16 outputs, protected
24V DC source
20.4…26.4V DC
160 mA @ 5.1V
8
1769-OB32
32 outputs
24V DC source
20.4…26.4V DC
300 mA @ 5.1V
6
1769-OB32T
32 outputs
24V DC source
10.2…26.4V DC
220 mA @ 5.1V
8
1769-OG16
16 outputs
5V DC TTL
4.5…5.5V DC
200 mA @ 5.1V
8
1769-OV16
16 outputs
24V DC sink
20.4…26.4V DC
200 mA @ 5.1V
8
1769-OV32T
32 outputs
24V DC sink
10.2…26.4V DC
300 mA @ 5.1V
8
1769 Contact Output Modules Cat. No.
Inputs/Outputs
Operating Voltage Range
Backplane Current
Power Supply Distance Rating
1769-OW8
8 outputs
5…265V AC 5…125V DC
125 mA @ 5.1V 100 mA @ 24V
8
1769-OW8I
8 outputs, individually isolated
5…265V AC 5…125V DC
125 mA @ 5.1V 100 mA @ 24V
8
1769-OW16
16 outputs
5…265V AC 5…125V DC
205 mA @ 5.1V 180 mA @ 24V
8
Rockwell Automation Publication 1769-SG001S-EN-P - December 2016
29
Page 30
Select a CompactLogix System
1769 Analog Modules Cat. No.
Inputs/Outputs
Range
Resolution
Backplane Current
Power Supply Distance Rating
1769-IF4
4 inputs, differential or single-ended
±10V 0…10V 0…5V 1…5V 0…20 mA 4…20 mA
14 bits (unipolar) 14 bits plus sign (bipolar)
120 mA @ 5.1V 60 mA @ 24V
8
1769-IF4I
4 inputs, differential or single-ended, individually isolated
±10V 0…10V 0…5V 1…5V 0…20 mA 4…20 mA
16 bits (unipolar) 15 bits plus sign (bipolar)
145 mA @ 5.1V 125 mA @ 24V
8
1769-IF8
8 inputs, differential or single-ended
±10V 0…10V 0…5V 1…5V 0…20 mA 4…20 mA
16 bits (unipolar) 15 bits plus sign (bipolar)
120 mA @ 5.1V 70 mA @ 24V
8
1769-IF16C
16 inputs, single-ended
0…20 mA 4…20 mA
16 bits (unipolar) 15 bits plus sign (bipolar)
190 mA @ 5.1V 70 mA @ 24V
8
1769-IF16V
16 inputs, single-ended
±10V 0…10V 0…5V 1…5V
16 bits (unipolar) 15 bits plus sign (bipolar)
190 mA @ 5.1V 70 mA @ 24V
8
1769-IF4XOF2
4 inputs, differential or single-ended 2 outputs, single-ended
0…10V 0…20 mA
Input: 8 bits plus sign Output: 8 bits plus sign
120 mA @ 5.1V 160 mA @ 24V
8
1769-IF4FXOF2F
4 inputs, fast differential or single-ended 2 outputs, fast single-ended
±10V 0…10V 0…5V 1…5V 0…20 mA 4…20 mA
Input: 14 bits (unipolar) 14 bits plus sign (bipolar) Output: 13 bits (unipolar) 13 bits plus sign (bipolar)
220 mA @ 5.1V 120 mA @ 24V
8
1769-OF2
2 outputs, single-ended
±10V 0…10V 0…5V 1…5V 0…20 mA 4…20 mA
14 bits (unipolar) 14 bits plus sign (bipolar)
120 mA @ 5.1V 120 mA @ 24V
8
1769-OF4
4 outputs, single-ended
±10V 0…10V 0…5V 1…5V 0…20 mA 4…20 mA
15 bits plus sign unipolar and bipolar
120 mA @ 5.1V 170 mA @ 24V
8
1769-OF4CI
4 outputs, differential, individually isolated
0…20 mA 4…20 mA
16 bits (unipolar)
165 mA @ 5V 110 mA @ 24V
8
30